[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-980608":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},980608,709,1,"单选题","截面为600mm× 600mm的方形预制桩，混凝土强度等级为C30，相应于荷载效应基本组合时的单桩竖向力设计值为3000kN，则桩身混凝土强度是否满足桩的承载力设计要求？（ ）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","满足要求",true,{"key":16,"text":17,"correct":18},"B","不满足要求",false,{"key":20,"text":21,"correct":18},"C","难以判断",{"key":23,"text":24,"correct":18},"D","若混凝土强度提高到C35则满足要求","根据《建筑地基基础设计规范》(GB 5007-2002)第8. 5. 9条规定，桩轴心受压时，应符合：Q≤Apfcψc。式中，为相应于荷载效应基本组合时的单桩竖向力设计值；fc为混凝土轴心抗压强度设计值；Ap为桩身横截面积；ψc为工作条件系数，预制桩取 0.75，灌注桩取0.6?0.7(水下灌注桩或长桩时用低值）。代入数据得：14.3×600×600×0. 75 =3861kN＞Q= 3000kN,即满足要求。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业知识","建筑工程",0]