[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-980475":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},980475,709,1,"单选题","计算单支点排桩地下连续墙的嵌固深度时应采用的计算方法是（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","连续梁法",false,{"key":16,"text":17,"correct":14},"B","静力平衡法",{"key":19,"text":20,"correct":21},"C","等值梁法",true,{"key":23,"text":24,"correct":14},"D","弹性支点法","根据《建筑基坑支护技术规程》（JGJ 120—1999）条文说明第4. 1. 1条，对于单支点支护结构，由于结构的平衡是依靠支点及嵌固深度两者共同支持，必须具有足够的嵌固深度以形成一定的反力，保证结构稳定，因此，采用传统的等值梁法来确定嵌固深度。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业知识","建筑工程",0]