[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-706-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":614},{"id":5,"name":6,"category":7,"favorite":8},706,"岩土专业案例","建筑工程",0,1,50,505,[13,33,45,57,69,81,93,104,116,128,140,152,164,175,187,199,211,223,235,246,258,270,281,293,305,317,329,341,353,365,376,388,400,412,424,436,448,459,471,483,495,507,518,530,542,554,566,578,590,602],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},977931,"单选题","某灌注桩直径800mm,桩身露出地面的长度为10m，桩入土长度为20m，桩端嵌入较完整的坚硬岩石，桩的水平变形系数α为0.520( 1\u002Fm)，桩顶铰接，桩顶以下5m范围内箍筋间距为200mm，该桩轴心受压，桩顶轴向压力设计值为6800kN,成桩工艺系数ψc取 0.8，按《建筑桩基技术规范》（JGJ 94—2008），试问桩身混凝土轴心抗压强度设计值应不小于下列何项数值？（ ）",[18,22,25,29],{"key":19,"text":20,"correct":21},"A","15MPa",false,{"key":23,"text":24,"correct":21},"B","17MPa",{"key":26,"text":27,"correct":28},"C","19MPa",true,{"key":30,"text":31,"correct":21},"D","21 MPa","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":19,"analysis":32},977933,"群桩基础中的某灌注基桩，桩身直径700mm，入土深度25m，配筋率为0.60%,桩身抗弯刚度EI为2. 83×105kN·m2，桩侧土水平抗力系数的比例系数m为2. 5MN\u002Fm4，桩顶为铰接，按《建筑桩基技术规范》（JGJ 94—2008）,试问当桩顶水平荷载为50kN时，其水平位移值最接近下列何项数值？（ ）",[37,39,41,43],{"key":19,"text":38,"correct":28},"6mm",{"key":23,"text":40,"correct":21},"9mm",{"key":26,"text":42,"correct":21},"12mm",{"key":30,"text":44,"correct":21},"15mm",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":30,"analysis":32},977935,"某软土地基上多层建筑，采用减沉复合疏桩基础，筏板平面尺寸为35m×10m,承台底设置钢筋混凝土预制方桩共计102根，桩截面尺寸为200mm×200mm，间距2m，桩长15m，正三角形布置，地层分布及土层参数如图4所示，试问按《建筑粧基技术规范》（JGJ 94—2008）计算的基础中心点由桩土相互作用产生的沉降ssp，其值与下列何项数值最为接近？（ ）",[49,51,53,55],{"key":19,"text":50,"correct":21},"6.4mm",{"key":23,"text":52,"correct":21},"8.4mm",{"key":26,"text":54,"correct":21},"11. 9mm",{"key":30,"text":56,"correct":28},"15.8mm",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":19,"analysis":32},977938,"柱下桩基承台，如图4-2所示，承台混凝土轴心抗拉强度设计值f1 = 1.71MPa，试按 《建筑桩基技术规范》（JGJ 94-2008），计算承台柱边A1—A1斜截面的受剪承载力，其值与下列何项数值最为接近？（图中尺寸单位为mm）( )",[61,63,65,67],{"key":19,"text":62,"correct":28},"1.00MN",{"key":23,"text":64,"correct":21},"1.21MN",{"key":26,"text":66,"correct":21},"1.53MN",{"key":30,"text":68,"correct":21},"2.04MN",{"id":70,"libraryId":5,"type":9,"typeLabel":15,"stem":71,"options":72,"answer":23,"analysis":32},977940,"某泥浆护壁灌注桩桩径800mm,桩长24m，采用桩端桩侧联合后注浆，桩侧注浆断面位于桩顶下12m,桩周土性及后注浆桩侧阻力与桩端阻力增强系数如图4-3所示。按《建筑桩基技术规范》（JGJ 94-2008）,估算的单桩极限承载力最接近于下列何项数值？ ( )",[73,75,77,79],{"key":19,"text":74,"correct":21},"5620kN",{"key":23,"text":76,"correct":28},"6460kN",{"key":26,"text":78,"correct":21},"7420kN",{"key":30,"text":80,"correct":21},"7700kN",{"id":82,"libraryId":5,"type":9,"typeLabel":15,"stem":83,"options":84,"answer":23,"analysis":32},977942,"铁路桥梁采用钢筋混凝土沉井基础，如图4-4所示，沉井壁厚0.4m，高度12m，排水挖土下沉施工完成后，沉井顶和河床面平齐，假定井壁四周摩擦力分布为倒三角，施工中沉井井壁截面的最大拉应力与下列何项数值最为接近？（注: 井壁容重为25kN\u002Fm3）( )",[85,87,89,91],{"key":19,"text":86,"correct":21},"0",{"key":23,"text":88,"correct":28},"75kPa",{"key":26,"text":90,"correct":21},"150kPa",{"key":30,"text":92,"correct":21},"300kPa",{"id":94,"libraryId":5,"type":9,"typeLabel":15,"stem":95,"options":96,"answer":30,"analysis":32},977944,"某公路桥梁钻孔灌注桩为摩擦桩，桩径1.0m，桩长35m。土层分布及桩侧摩阻力标准值qik、桩端处土的承载力基本容许值[fa0]如图4-5所示。桩端以上各土层的加权平均重度y2=20kN\u002Fm3,桩端处土的容许承载力随深度的修正系数k2=5.0。根据《公路桥涵地基与基础设计规范》(JGT D63-2007)计算，试问单桩轴向受压承载力容许值最接近下列哪个选项的数值？（取修正系数λ=0.8，清底系数m0=0.8)( )",[97,98,100,102],{"key":19,"text":74,"correct":21},{"key":23,"text":99,"correct":21},"5780kN",{"key":26,"text":101,"correct":21},"5940kN",{"key":30,"text":103,"correct":28},"6280kN",{"id":105,"libraryId":5,"type":9,"typeLabel":15,"stem":106,"options":107,"answer":26,"analysis":32},977946,"某柱下单桩独立基础采用混凝土灌注桩，如图4-6 所示桩径800mm，桩长30m。在荷载效应准永久组合作用下，作用在桩顶的附加荷载Q=6000kN。桩身混凝土弹性模量Ec =3. 15×104N\u002Fmm2。在该桩桩端以下的附加应力（假定按分段线性分布）及土层压缩模量如图所示，不考虑承台分担荷载作用。根据《建筑桩基技术规范》 (JGJ 94—2008）计算，该单桩基础最终沉降量最接近于下列哪个选项的数值？（取沉降计算经验系数ψ= 1.0，桩身压缩系数ξe=0.6）( )",[108,110,112,114],{"key":19,"text":109,"correct":21},"55mm",{"key":23,"text":111,"correct":21},"60mm",{"key":26,"text":113,"correct":28},"67mm",{"key":30,"text":115,"correct":21},"72mm",{"id":117,"libraryId":5,"type":9,"typeLabel":15,"stem":118,"options":119,"answer":23,"analysis":32},977948,"某柱下六桩独立桩基，承台埋深3.0m，承台面积取2.4m×4.0m，采用直径0.4m的灌注桩，桩长12m，距径比sa\u002Fd=4,桩顶以下土层参数如表4-1所示。根据《建筑桩基技术规范》（JG J94-2008）,考虑承台效应（取承台效应系数ηc=0. 14）,试确定考虑地震作用时的复合基桩竖向承载力特征值与单桩承载力特征值之比最接近于下列哪个选项的数值？（取地基抗震承载力调整系数ξa=1.5)( )",[120,122,124,126],{"key":19,"text":121,"correct":21},"1.05",{"key":23,"text":123,"correct":28},"1.11",{"key":26,"text":125,"correct":21},"1. 16",{"key":30,"text":127,"correct":21},"1.20",{"id":129,"libraryId":5,"type":9,"typeLabel":15,"stem":130,"options":131,"answer":30,"analysis":32},977950,"某工程采用泥浆护壁钻孔灌注桩，桩径1200mm,桩端进入中等风化岩1.0m，中等风化岩岩体较完整，饱和单轴抗压强度标准值为41. 5MPa，桩顶以下土层参数如表4 -2所示。按《建筑桩基技术规范》（JGJ 94—2008），估算单桩极限承载力最接近下列哪个选项的数值？（取桩嵌岩段侧阻和端阻综合系数ξr=0. 76) ( )",[132,134,136,138],{"key":19,"text":133,"correct":21},"32200kN",{"key":23,"text":135,"correct":21},"36800kN",{"key":26,"text":137,"correct":21},"40800kN",{"key":30,"text":139,"correct":28},"44200kN",{"id":141,"libraryId":5,"type":9,"typeLabel":15,"stem":142,"options":143,"answer":30,"analysis":32},977952,"某地下车库作用有141MN浮力，基础及上部结构和土重为108MN。拟设置直径 600mm、长10m的抗拔桩，桩身重度为25kN\u002Fm3。水的重度取10kN\u002Fm3。基础底面以下10m内为粉质黏土，其桩侧极限摩阻力为36kPa，车库结构侧面与土的摩擦力忽略不计。按《建筑桩基技术规范》（JGJ 94—2008），按群桩呈非整体破坏，估算需设置抗拔桩的数量至少应大于下列哪个选项？（取粉质黏土抗拔系数λ= 0. 70) ( )",[144,146,148,150],{"key":19,"text":145,"correct":21},"83 根",{"key":23,"text":147,"correct":21},"89 根",{"key":26,"text":149,"correct":21},"108 根",{"key":30,"text":151,"correct":28},"118 根",{"id":153,"libraryId":5,"type":9,"typeLabel":15,"stem":154,"options":155,"answer":26,"analysis":32},977954,"某柱下桩基采用等边三柱独立承台，承台等厚三向均匀配筋，如图4-7所示。在荷载效应基本组合下，作用于承台顶面的轴心竖向力为2100kN，承台及其上土重标准值为300kN。按《建筑桩基技术规范》（JGJ 94—2008）计算，该承台正截面最大弯矩最接近下列哪个选项的数值？（ ）",[156,158,160,162],{"key":19,"text":157,"correct":21},"531 kN·m",{"key":23,"text":159,"correct":21},"670kN·m",{"key":26,"text":161,"correct":28},"247kN·m",{"key":30,"text":163,"correct":21},"814kN·m",{"id":165,"libraryId":5,"type":9,"typeLabel":15,"stem":166,"options":167,"answer":19,"analysis":32},977956,"如图4-8所示，竖向荷载设计值F=24000kN，承台混凝 土为C40(ft = 1.71MPa),按《建筑桩基技术规范》验算柱边A—A至桩边连线形成的斜截面的抗剪承载力与剪切力之比（抗力\u002FV）最接近下列哪个选项？（ ）",[168,169,171,173],{"key":19,"text":121,"correct":28},{"key":23,"text":170,"correct":21},"1.2",{"key":26,"text":172,"correct":21},"1.3",{"key":30,"text":174,"correct":21},"1.4",{"id":176,"libraryId":5,"type":9,"typeLabel":15,"stem":177,"options":178,"answer":23,"analysis":32},977958,"某一柱一桩（端承灌注桩）基础，桩径1.0m,桩长20m,承受轴向竖向荷载设计值N= 5000kN,地表大面积堆载，P=60kPa,桩周土层分布如图4-9所示。根据《建筑桩基技术规范》(JGJ 94-2008)桩身 混凝土强度等级选用下列哪一数值最经济合理？考虑地震作用，灌注桩施工工艺系数ψc=0.7，负摩阻力系数ξn=0. 20) ( ) 提示：",[179,181,183,185],{"key":19,"text":180,"correct":21},"C20",{"key":23,"text":182,"correct":28},"C25",{"key":26,"text":184,"correct":21},"C30",{"key":30,"text":186,"correct":21},"C35",{"id":188,"libraryId":5,"type":9,"typeLabel":15,"stem":189,"options":190,"answer":23,"analysis":32},977960,"作用于桩基承台顶面的竖向力设计值为5000kN，x方向的偏心距为0.1m，不计承台及承台上土自重，承台下布置4根桩，如图4-10所示。根据《建筑桩基技术规范》（JGJ 94一2008）计算，承台承受的正截面最大弯矩与下列哪个选项的数值最为接近？（ ）",[191,193,195,197],{"key":19,"text":192,"correct":21},"1999. 8kN·m",{"key":23,"text":194,"correct":28},"2166.4kN·m",{"key":26,"text":196,"correct":21},"2999. 8kN·m",{"key":30,"text":198,"correct":21},"3179. 8kN·m",{"id":200,"libraryId":5,"type":9,"typeLabel":15,"stem":201,"options":202,"answer":19,"analysis":32},977962,"一圆形等截面沉井，排水挖土下沉过程中处于如图 4-11所示状态，刃脚完全掏空，井体仍然悬在土中。假设井壁外侧摩阻力呈倒三角形分布，沉井自重G0=1800kN，问地表下5m处井壁所受拉力最接近下列何值（假定沉井自重沿深度均匀分布）？ ( )",[203,205,207,209],{"key":19,"text":204,"correct":28},"300kN",{"key":23,"text":206,"correct":21},"450kN",{"key":26,"text":208,"correct":21},"600kN",{"key":30,"text":210,"correct":21},"800kN",{"id":212,"libraryId":5,"type":9,"typeLabel":15,"stem":213,"options":214,"answer":30,"analysis":32},977964,"刚性桩穿过厚20m的未充分固结新近填土层，并以填土层的下卧层为桩端持力层，在其他条件相同情况下，下列哪个选项作为桩端持力层时，基桩承受的下拉荷载最大？（）",[215,217,219,221],{"key":19,"text":216,"correct":21},"可塑状黏土",{"key":23,"text":218,"correct":21},"红黏土",{"key":26,"text":220,"correct":21},"残积土",{"key":30,"text":222,"correct":28},"微风化砂岩",{"id":224,"libraryId":5,"type":9,"typeLabel":15,"stem":225,"options":226,"answer":19,"analysis":32},977967,"某桩基的多跨条形连续承台梁净跨距均为7.0m，承台梁受均布荷载q= 100kN\u002Fm作用。问承台梁中跨支座处弯距M最接近（ ）kN·m。",[227,229,231,233],{"key":19,"text":228,"correct":28},"450",{"key":23,"text":230,"correct":21},"498",{"key":26,"text":232,"correct":21},"530",{"key":30,"text":234,"correct":21},"568",{"id":236,"libraryId":5,"type":9,"typeLabel":15,"stem":237,"options":238,"answer":23,"analysis":32},977969,"沉井靠自重下沉，若不考虑浮力及刃脚反力作用，则下沉系数K=Q\u002FT，式中Q为沉井自重，T为沉井与土间的摩阻力，（假设T=π D)(H-2.5)f)，某工程地质剖面及设计沉井尺寸如图4 - 12所示，沉井外径D =20m，下沉深度为16.5m，井身混凝土体积为977m3，混凝土重度为24kN\u002Fm3，请验算沉井在下沉到图4-12所示位置时的下沉系数K最接近（ ）。",[239,241,242,244],{"key":19,"text":240,"correct":21},"1. 10",{"key":23,"text":127,"correct":28},{"key":26,"text":243,"correct":21},"1.28",{"key":30,"text":245,"correct":21},"1.35",{"id":247,"libraryId":5,"type":9,"typeLabel":15,"stem":248,"options":249,"answer":23,"analysis":32},977971,"某桩基工程设计等级为乙级，其桩型平面布置、剖面和地层分布如图4-13所示，已知轴力F = 12000kN，力矩M = 1030kN·m，水平力H=600kN,承台和填土的平均重度为20kN\u002Fm3，自重荷载分项系数取1. 2，桩顶轴向压力最大设计值的计算结果最接近 ( )kN。",[250,252,254,256],{"key":19,"text":251,"correct":21},"1020",{"key":23,"text":253,"correct":28},"1232",{"key":26,"text":255,"correct":21},"1380",{"key":30,"text":257,"correct":21},"1520",{"id":259,"libraryId":5,"type":9,"typeLabel":15,"stem":260,"options":261,"answer":30,"analysis":32},977973,"某桩基三角形承台如图4-14所示，承台厚度1.1m,钢筋保护层厚度0.1m，承台混凝 土抗拉强度设计值ft= 1·7N\u002Fmm2，试按《建筑桩基技术规范》(JGJ 94—2008)计算承台受底部角桩冲切的承载力，其值最接近（ ）kN。",[262,264,266,268],{"key":19,"text":263,"correct":21},"1500",{"key":23,"text":265,"correct":21},"2010",{"key":26,"text":267,"correct":21},"2430",{"key":30,"text":269,"correct":28},"2790",{"id":271,"libraryId":5,"type":9,"typeLabel":15,"stem":272,"options":273,"answer":26,"analysis":32},977975,"某丙级建筑物扩底抗拔灌注桩桩径d = 1.0m，桩长12m,扩底直径D =1.8m 扩底段高度hc=1.2m，桩周土性参数如图4 - 15所示，试按《建筑桩基技术规范》（JGJ 94-2008），按非整体破坏，计算基桩的抗拔极限承载力标准值，其值最接近（ ）kN。 (抗拔系数：粉质黏土为λ=0.7；砂土为λ =0.5)",[274,275,277,279],{"key":19,"text":255,"correct":21},{"key":23,"text":276,"correct":21},"1780",{"key":26,"text":278,"correct":28},"2000",{"key":30,"text":280,"correct":21},"2580",{"id":282,"libraryId":5,"type":9,"typeLabel":15,"stem":283,"options":284,"answer":23,"analysis":32},977977,"某桩基工程的桩型平面布置、剖面及地层分布如图4-16所示，作用于桩端平面处的有效附加应力为400kPa，其中心点的附加压力曲线如图4 - 16 ( b)所示（假定为直线分布），沉降经验系数ψ= 1.0，地基沉降计算深度至基岩面，请按《建筑桩基技术规范》 (JGJ 94—2008)验算桩基最终沉降量，其计算结果最接近（ ）cm。",[285,287,289,291],{"key":19,"text":286,"correct":21},"3.6",{"key":23,"text":288,"correct":28},"6. 1",{"key":26,"text":290,"correct":21},"7.9",{"key":30,"text":292,"correct":21},"8.6",{"id":294,"libraryId":5,"type":9,"typeLabel":15,"stem":295,"options":296,"answer":19,"analysis":32},977979,"某受压灌注桩桩径为1.2m，桩端入土深度20m,桩身配筋率0.6%，桩顶铰接，桩顶竖向压力设计值N= 5000kN，桩的水平变形系数α=0.301-1桩身换算截面积An= 1.2m2，换算截面受拉边缘的截面模量W0=0.2m2，桩身混凝土抗拉强度设计值ft=1. 5N\u002Fmm2,试按《建筑桩基技术规范》(JGJ 94-2008)计算单桩水平承载力设计值，其值最接近（ ）kN。",[297,299,301,303],{"key":19,"text":298,"correct":28},"410",{"key":23,"text":300,"correct":21},"600",{"key":26,"text":302,"correct":21},"650",{"key":30,"text":304,"correct":21},"700",{"id":306,"libraryId":5,"type":9,"typeLabel":15,"stem":307,"options":308,"answer":23,"analysis":32},977981,"某端承灌注桩桩径1.0m，桩长22m,桩周土性参数如图4- 17所示，地面大面积堆载P=60kPa，桩周沉降变形土层下限深度20m，试按《建筑粧基技术规范》（JGJ 94—2008） 计算下拉荷载标准值，其值最接近（ ）kN。（已知黏土负摩阻力系数ζn=0.3，粉质黏土负摩阻力系数ζn=0.4,负摩阻力群桩效应系数ηn= 1.0）",[309,311,313,315],{"key":19,"text":310,"correct":21},"1880",{"key":23,"text":312,"correct":28},"2200",{"key":26,"text":314,"correct":21},"2510",{"key":30,"text":316,"correct":21},"3140",{"id":318,"libraryId":5,"type":9,"typeLabel":15,"stem":319,"options":320,"answer":30,"analysis":32},977983,"某框架柱采用桩基础，承台下5根Φ=600mm的钻孔灌注桩，桩长l=15m，如图4-18 所示，承台顶处柱竖向轴力F = 3840kN，My=161kN·m，承台及其上覆土自重设计值 G=447kN,基桩最大竖向力Nmax为（ ）kN。",[321,323,325,327],{"key":19,"text":322,"correct":21},"831",{"key":23,"text":324,"correct":21},"858",{"key":26,"text":326,"correct":21},"886",{"key":30,"text":328,"correct":28},"902",{"id":330,"libraryId":5,"type":9,"typeLabel":15,"stem":331,"options":332,"answer":30,"analysis":32},977985,"群桩基础，桩径d=0.6m,桩的换算埋深αh≥4.0，单桩水平承载力特征值Rh= 50kN (位移控制）沿水平荷载方向布桩排数n1= 3排，每排桩数n2= 4根，距径比sa\u002Fd = 3， 承台底位于地面上50mm，按《建筑桩基技术规范》(JGJ 94—2008)计算群桩中复合基桩水平承载力特征值最接近（ ）kN。",[333,335,337,339],{"key":19,"text":334,"correct":21},"45",{"key":23,"text":336,"correct":21},"50",{"key":26,"text":338,"correct":21},"55",{"key":30,"text":340,"correct":28},"65",{"id":342,"libraryId":5,"type":9,"typeLabel":15,"stem":343,"options":344,"answer":23,"analysis":32},977987,"柱下桩基如图4-19所示，承台混凝土抗压强度f1=1.71MPa；按《建筑粧基技术规范》（JGJ 94—2008）计算承台长边受剪承载力，其值最接近（ ）MN。",[345,347,349,351],{"key":19,"text":346,"correct":21},"6.5",{"key":23,"text":348,"correct":28},"8.5 3",{"key":26,"text":350,"correct":21},"10.5",{"key":30,"text":352,"correct":21},"12.5",{"id":354,"libraryId":5,"type":9,"typeLabel":15,"stem":355,"options":356,"answer":26,"analysis":32},977989,"某工程双桥静探资料见表4-3，拟采用③层粉砂做持力层，采用混凝土方桩，桩断面尺寸为400×400mm，桩长l= 13m，承台埋深为2.0m， 桩端进入粉砂层2. 0m，按《建筑桩基技术规范》（JGJ 94 — 2008）计算单桩竖向极限承载标准值最接近（ ）kN。",[357,359,361,363],{"key":19,"text":358,"correct":21},"1220",{"key":23,"text":360,"correct":21},"1580",{"key":26,"text":362,"correct":28},"1715",{"key":30,"text":364,"correct":21},"1900",{"id":366,"libraryId":5,"type":9,"typeLabel":15,"stem":367,"options":368,"answer":26,"analysis":32},977991,"某端承型单桩基础，桩入土深度12m，桩径d=0.8m，桩顶荷载Q0=500kN，由于地表进行大面积堆载而产生了负摩阻力，负摩阻力平均值为qns=20kPa,中性点位于桩顶下6m,桩身最大轴力最接近于下列（ ）kN。",[369,371,372,374],{"key":19,"text":370,"correct":21},"500",{"key":23,"text":302,"correct":21},{"key":26,"text":373,"correct":28},"800",{"key":30,"text":375,"correct":21},"900",{"id":377,"libraryId":5,"type":9,"typeLabel":15,"stem":378,"options":379,"answer":26,"analysis":32},977993,"图4-20为一穿过自重湿陷性黄土端承于含卵石的极密砂层的高承台基桩，有关土性系数及深度值如图表。当地基严重浸水时，按《建筑桩基技术规范》(JGJ 94-2008)计算，负摩阻力Q最接近于（ ）kN。（计算时取ζn=0.3，ηn=1.0，饱和度为80%时的平均重度为18kN\u002Fm3，桩周长u = 1. 884m,下拉荷载累计至砂层顶面）",[380,382,384,386],{"key":19,"text":381,"correct":21},"178",{"key":23,"text":383,"correct":21},"366",{"key":26,"text":385,"correct":28},"509",{"key":30,"text":387,"correct":21},"610",{"id":389,"libraryId":5,"type":9,"typeLabel":15,"stem":390,"options":391,"answer":30,"analysis":32},977995,"某柱下桩基(y0= 1)如图4—21所示，柱宽hc=0.6m，承台有效高度h0= 1. 0m,冲跨比λ= 0. 7，承台混凝土抗拉强度设计值ft= 1. 71 MPa，作用于承台顶面的竖向力设计值 F = 7500kN，按《建筑桩基技术规范》（JGJ 94—2008）验算柱冲切承载力时，下述结论正确的是（ ） 。",[392,394,396,398],{"key":19,"text":393,"correct":21},"受冲切承载力比冲切力小800kN",{"key":23,"text":395,"correct":21},"受冲切承载力与冲切力相等",{"key":26,"text":397,"correct":21},"受冲切承载力比冲切力大810kN",{"key":30,"text":399,"correct":28},"受冲切承载力比冲切力大2129kN",{"id":401,"libraryId":5,"type":9,"typeLabel":15,"stem":402,"options":403,"answer":23,"analysis":32},977997,"桩顶为自由端的钢管桩，桩径d=0.6m，桩入土深度h=10m，地基土水平抗力系数的比例系数m =10MN\u002Fm4，桩身抗弯刚度EI= 1. 7×105 kN·m2,桩水平变形系数α= 0. 59m-1,桩顶容许水平位移χ0a= 10mm,按《建筑桩基技术规范》(JGJ 94—2008)计算， 单桩水平承载力特征值最接近（ ）kN。",[404,406,408,410],{"key":19,"text":405,"correct":21},"75",{"key":23,"text":407,"correct":28},"107",{"key":26,"text":409,"correct":21},"143",{"key":30,"text":411,"correct":21},"175",{"id":413,"libraryId":5,"type":9,"typeLabel":15,"stem":414,"options":415,"answer":23,"analysis":32},977999,"如图4 -22所示，某泵房按丙级桩基考虑，为抗浮设置抗拔桩，上拔力设计值为 600kN,桩型采用钻孔灌注桩，桩径d=550mm,桩长l= 16m，桩群边缘尺寸为20m×10m，桩数为50根，按《建筑桩基技术规范》(JGJ 94-2008)计算群桩基础及基桩的抗拔承载力，下列哪一组与结果最接近？（ ）（抗拔系数λi:对黏性土取0.7，对砂土取0.6,桩身材料重度y=25kN\u002Fm3；群桩基础平均重度y =20kN\u002Fm3)",[416,418,420,422],{"key":19,"text":417,"correct":21},"群桩和基桩都满足要求",{"key":23,"text":419,"correct":28},"群桩满足要求，基桩不满足要求",{"key":26,"text":421,"correct":21},"群桩不满足要求，基桩满足要求",{"key":30,"text":423,"correct":21},"群桩和基桩都不满足要求",{"id":425,"libraryId":5,"type":9,"typeLabel":15,"stem":426,"options":427,"answer":23,"analysis":32},978001,"某群桩基础的平面剖面如图4-23所示，已知作用于桩端平面处长期效应组合的附加压力为300kPa，沉降计算经验系数ψ= 0.7，其他系数见表4-4,按《建筑桩基技术规范》 (JGJ 94—2008)估算群桩基础的沉降量，其值最接近（ ）cm。",[428,430,432,434],{"key":19,"text":429,"correct":21},"2.5",{"key":23,"text":431,"correct":28},"3.0",{"key":26,"text":433,"correct":21},"3.5",{"key":30,"text":435,"correct":21},"4.0",{"id":437,"libraryId":5,"type":9,"typeLabel":15,"stem":438,"options":439,"answer":30,"analysis":32},978003,"某柱下单桩为钻孔灌注桩，桩径为800mm，桩长为15m，桩顶入土深度为2.0m，桩顶竖向力设计值为2200kN，桩端极限阻力标准值为1200kN，桩侧极限阻力标准值为2000kN，由于承载力验算不满足要求，故改为扩底桩，扩底段高度为2.0m，桩端土为砂土，则扩底桩端直径宜为（ ）mm。",[440,442,444,446],{"key":19,"text":441,"correct":21},"896",{"key":23,"text":443,"correct":21},"978",{"key":26,"text":445,"correct":21},"1000",{"key":30,"text":447,"correct":28},"1292",{"id":449,"libraryId":5,"type":9,"typeLabel":15,"stem":450,"options":451,"answer":19,"analysis":32},978005,"某承台下设三根钻孔灌注桩（干作业），桩径为600mm，桩长11m，各层土的厚度、侧阻、端阻如图4-24所示，则计算得基桩承载力特征值为（ ）kN。",[452,453,455,457],{"key":19,"text":302,"correct":28},{"key":23,"text":454,"correct":21},"760",{"key":26,"text":456,"correct":21},"770",{"key":30,"text":458,"correct":21},"780",{"id":460,"libraryId":5,"type":9,"typeLabel":15,"stem":461,"options":462,"answer":30,"analysis":32},978007,"某工程承台埋深1.5m,下设钢管桩直径700mm,壁厚10mm,桩长26.5m，桩端带隔板开口桩，n=2。土层分布情况为：0~3.0m填土，桩侧极限侧阻力标准值qsk=25kPa； 3.0~8.5m 黏土层，qsk =50kPa； 8. 5 ~25.0m 粉土层，qsk =65kPa； 25. 0 ~ 30.0m 中砂， qsk =75kPa； qpk =7000kPa,计算此钢管桩的竖向极限承载力为（ ）kN。",[463,465,467,469],{"key":19,"text":464,"correct":21},"3582",{"key":23,"text":466,"correct":21},"4618",{"key":26,"text":468,"correct":21},"5448",{"key":30,"text":470,"correct":28},"5693",{"id":472,"libraryId":5,"type":9,"typeLabel":15,"stem":473,"options":474,"answer":19,"analysis":32},978009,"某工程用桩为灌注桩，桩径0.8m，入土深度L=28m，桩身配筋12Φ16，采用C30混凝土，桩侧土水平抗力系数的比例系数m = 14MN\u002Fm4,已知条件：C30混凝土弹性模量为3.0×104N\u002Fmm2，抗拉强度设计值ft= 1430kN\u002Fm2，钢筋弹性模量为2. 0×105 N\u002Fmm2。 设桩顶竖向力N= 2584kN，则其单桩水平承载力特征值接近（ ）kN。",[475,477,479,481],{"key":19,"text":476,"correct":28},"199",{"key":23,"text":478,"correct":21},"232",{"key":26,"text":480,"correct":21},"246",{"key":30,"text":482,"correct":21},"259",{"id":484,"libraryId":5,"type":9,"typeLabel":15,"stem":485,"options":486,"answer":30,"analysis":32},978011,"某工程采用边长400mm预制混凝土方桩，有效桩长l=11.5m，承台埋深2. 5m,此场区单桥静力触探结果如图4-25所示。计算单桩竖向极限承载力标准值为（）kN。",[487,489,491,493],{"key":19,"text":488,"correct":21},"707",{"key":23,"text":490,"correct":21},"717",{"key":26,"text":492,"correct":21},"727",{"key":30,"text":494,"correct":28},"816",{"id":496,"libraryId":5,"type":9,"typeLabel":15,"stem":497,"options":498,"answer":23,"analysis":32},978013,"某建筑场地土层的各项数据指标如表4-5所示，桩基承台埋深1.5m，.采用钢筋混凝土预制桩，桩长22m、截面尺寸为450mm×450mm,.试依据《建筑桩基技术规范》（JGJ 94-2008）推荐的经验公式计算单桩承载力。根据双桥探头静力触探试验结果计算单桩承载力，其值接近于（）kN。",[499,501,503,505],{"key":19,"text":500,"correct":21},"1107",{"key":23,"text":502,"correct":28},"1218",{"key":26,"text":504,"correct":21},"1800",{"key":30,"text":506,"correct":21},"2107",{"id":508,"libraryId":5,"type":9,"typeLabel":15,"stem":509,"options":510,"answer":19,"analysis":32},978015,"某工程，在单桩竖向静载荷试验中得到三根试桩的单桩竖向承载力分别为860kN、 880kN、890kN。根据《建筑桩基技术规范》（JGJ 94—2008）的规定，所采用的单桩竖向承载力特征值R最接近于（ ）kN。",[511,513,514,516],{"key":19,"text":512,"correct":28},"438",{"key":23,"text":230,"correct":21},{"key":26,"text":515,"correct":21},"588",{"key":30,"text":517,"correct":21},"638",{"id":519,"libraryId":5,"type":9,"typeLabel":15,"stem":520,"options":521,"answer":19,"analysis":32},978017,"有一桩基础，建筑场地土层分布见表4-6，第五层为持力层，桩尖进入持力层约1m，基桩的有效长度为20m，承台埋深2m，桩的截面尺寸为600mm×600mm。用静力触探法估算单桩承载力特征值，其大小最接近于（ ）kN。",[522,524,526,528],{"key":19,"text":523,"correct":28},"1657",{"key":23,"text":525,"correct":21},"2023",{"key":26,"text":527,"correct":21},"2600",{"key":30,"text":529,"correct":21},"2765",{"id":531,"libraryId":5,"type":9,"typeLabel":15,"stem":532,"options":533,"answer":19,"analysis":32},978019,"某场地地表以下2 ~ 10m为粉土层，桩的极限侧阻力标准值qs1k =60kPa；10 ~ 20m为黏性土，qs2k=50kPa； 20~40m 为中砂，qs3k =70kPa,极限端阻力qpk =6000kPa。承台底在地表下2m，采用直径900mm的沉管灌注桩，桩端入土23m,根据《建筑桩基技术规范》（JGJ 94一2008）计算单桩竖向极限承载力标准值Quk，其结果最接近下列哪一个数值？( )",[534,536,538,540],{"key":19,"text":535,"correct":28},"6942. 4kN",{"key":23,"text":537,"correct":21},"7029. 4kN",{"key":26,"text":539,"correct":21},"7154. 9kN",{"key":30,"text":541,"correct":21},"7239. 5kN",{"id":543,"libraryId":5,"type":9,"typeLabel":15,"stem":544,"options":545,"answer":19,"analysis":32},978021,"某建筑场地条件为：地表以下0~12m为可塑状态黏性土，单桥静力触探比贯入阻力Ps为1200kPa；12m以下为密实粗砂，比贯入阻力为5800kPa，场地中拟采用灌注桩基础，桩长为12m，桩径为0.5m，桩顶入土深度为2.0m,根据《建筑桩基技术规范》（JGJ 94一2008）计算得单桩极限承载力标准值为（ ）kN。",[546,548,550,552],{"key":19,"text":547,"correct":28},"1610",{"key":23,"text":549,"correct":21},"1660",{"key":26,"text":551,"correct":21},"1710",{"key":30,"text":553,"correct":21},"1760",{"id":555,"libraryId":5,"type":9,"typeLabel":15,"stem":556,"options":557,"answer":19,"analysis":32},978023,"一钢筋混凝土预制方桩，边长为30cm，桩的入土深度为13m。地层第一层为杂填土， 厚为lm；第二层为淤泥质土，液性指数为0.9，厚为5m；第三层为黏土，液性指数为0.50，厚为2m；第四层为粗砂，标准贯入击数为8，该层厚度较大，未贯穿，则该单桩竖向承载力标准值最接近（ ）kN。",[558,560,562,564],{"key":19,"text":559,"correct":28},"1520.4",{"key":23,"text":561,"correct":21},"1303.5",{"key":26,"text":563,"correct":21},"1275. 8",{"key":30,"text":565,"correct":21},"1128.6",{"id":567,"libraryId":5,"type":9,"typeLabel":15,"stem":568,"options":569,"answer":26,"analysis":32},978025,"某工程采用直径800mm，l=21m的钢管桩，桩顶入土 2m，桩端入土 23m,场地条件为地表以下深度2 ~ 12m为黏性土，桩的极限侧阻力标准值qs1k=50kPa； 12 ~20m为粉土层，qs2k=60kPa；20~30m为中砂，9s3k =80kPa，极限端阻力qpk =7000kPa。根据《建筑桩基技术规范》（JGJ 94-2008）计算敞口钢管桩桩端加设十字形隔板的单桩竖向极限承载力标准值Quk其结果最接近（ ）kN。",[570,572,574,576],{"key":19,"text":571,"correct":21},"5.3×103",{"key":23,"text":573,"correct":21},"5. 6×103",{"key":26,"text":575,"correct":28},"5. 9×103",{"key":30,"text":577,"correct":21},"6. 1× 103",{"id":579,"libraryId":5,"type":9,"typeLabel":15,"stem":580,"options":581,"answer":26,"analysis":32},978027,"如图4-26所示，进行软弱下卧层强度验算，桩为直径400mm灌注桩，桩长l=9m，各层土的y均为20kN\u002Fm3，重要性系数y0=1。计算得软弱下卧层顶面处自重应力、附加应力及承载力特征值分别为（ ）。",[582,584,586,588],{"key":19,"text":583,"correct":21},"210kPa； 30kPa； 317kPa",{"key":23,"text":585,"correct":21},"210kPa； 30kPa； 327kPa",{"key":26,"text":587,"correct":28},"260kPa； 62kPa； 310kPa",{"key":30,"text":589,"correct":21},"220kPa； 41kPa； 317kPa",{"id":591,"libraryId":5,"type":9,"typeLabel":15,"stem":592,"options":593,"answer":23,"analysis":32},978029,"如图4-27所示，某六桩基础承受上部结构荷载和承台及上覆土（已考虑了自重荷载分项系数）重8000kN，=250kN·m，My =600kN·m,试计算1号桩和2号桩桩顶所承受的荷载大小，其值最接近于（ ）。",[594,596,598,600],{"key":19,"text":595,"correct":21},"N1=1489kN； N2 = 1505kN",{"key":23,"text":597,"correct":28},"N1=1287kN； N2 = 1505kN",{"key":26,"text":599,"correct":21},"N1=1287kN； N2 = 1689kN",{"key":30,"text":601,"correct":21},"N1=1489kN；N2 =1689kN",{"id":603,"libraryId":5,"type":9,"typeLabel":15,"stem":604,"options":605,"answer":30,"analysis":32},978031,"某建筑物采用柱下桩基础，有6根钢筋混凝土预制桩，边长为400mm，桩长为22m，平面布置如图4-28所示。桩顶入土深度为2m，桩端入土深度24m，建筑桩基设计等级为乙级。假定由经验法估算得到单桩的总极限侧阻力标准值及极限端阻力标准值分别为1700kN和500kN，承台底部为厚层粉土，其极限承载力标准值为160kPa。考虑桩群、 土、承台相互作用效应，根据《建筑桩基技术规范》（JGJ 94—2008）计算非端承桩复合基桩竖向承载力特征值R，其值最接近（）kN。",[606,608,610,612],{"key":19,"text":607,"correct":21},"1.2×103",{"key":23,"text":609,"correct":21},"1.5×103",{"key":26,"text":611,"correct":21},"1.6×103",{"key":30,"text":613,"correct":28},"1.7×103",[615,618,621,624,627,630],{"id":9,"name":616,"category":7,"favorite":617},"领导干部任职前廉政法规知识测试题",92,{"id":619,"name":620,"category":7,"favorite":9},595,"建筑结构与设备",{"id":622,"name":623,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":625,"name":626,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":628,"name":629,"category":7,"favorite":8},534,"BIM工程师",{"id":631,"name":629,"category":7,"favorite":8},535]