[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978705":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},978705,706,1,"单选题","某建筑工程场地地质资料为：0?-5m为黏土，qsik=30kPa，-5~-15m为粉土，黏粒含量2.5%，qsik=20kPa，-15~-30m为密砂，qsik=50kPa，qpk =3510kPa。建筑物采用预制方桩，桩截面尺寸为350mm×350mm，桩长16.5m，桩顶离地面-1.5m，桩承台底面离地面-2.0m，桩顶0.5m嵌入桩承台，地下水位位于地表下-3.0m,场地位于8度地震区。试求： (2)地表下-10.0m处实际标贯锤击数为7击，临界标贯锤击数10击时，按桩承受全部地震作用，单桩竖向抗震承载力特征值是（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","452",false,{"key":16,"text":17,"correct":18},"B","565",true,{"key":20,"text":21,"correct":14},"C","653",{"key":23,"text":24,"correct":14},"D","950","地表下-10.0m处实际标贯锤击数为7击，临界标贯锤击数10击时，该场地为液化土层。桩承台底面上、下分别有厚度不小于1.5m、1.0m的非液化土层或非软弱土层。 桩承受全部地震作用，地表下5~10m为粉土，λ=7\u002F10=0.7，液化土的桩周摩阻力应乘以折减系数ψ1=1\u002F3，地表下10?15m为粉土，液化土的粧周摩阻力应乘以折减系数ψ2=2\u002F3。 故根据《建筑桩基技术规范》（JGJ 94—2008）第5. 3. 3条，单桩极限承载力标准值为：Quk=Qsk+Qpk=u∑qsikli+αpskAp=4×0.35×(3×30+1\u002F3×5×20 + 2\u002F3×5×20 + 3×50) +0.352×3500= 904.75kN； 则单桩承载力特征值是：Ra=Quk\u002F2=904.75\u002F2=452.375kN。 桩的竖向抗震承载力特征值，可均比非抗震设计时提高25%,则： RaE=1.25×452.37=565.47 kN",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]