[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978676":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},978676,706,1,"单选题","某建筑场地抗震设防烈度为7度，地基设计基本地震加速度为0.15g，设计地震分组为第二组，地下水位埋深2.0m，未打桩前的液化判别等级如表9-7所示，采用打入式混凝土预制桩，桩截面为400mm×400mm，桩长l=15m，桩间距s=1.6m，桩数20×20根，置换率ρ=0.063,打桩后液化指数由原来的12.9降为（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","2.7",true,{"key":16,"text":17,"correct":18},"B","4. 5",false,{"key":20,"text":21,"correct":18},"C","6.8",{"key":23,"text":24,"correct":18},"D","8.0","根据《建筑抗震设计规范》(GB 50011 —2010)第4. 4. 3条和第4. 3. 5条， 已知打桩后桩间土的标准贯入锤击数计算公式为：N1=NP+100ρ（1-e-0.3NP），则可得： 深度4m处，N1=5+100×0.063×(1-2.718-0.3×5)=9.89； 深度5m处，N1=9+100×0.063×(1-2.718-0.3×9)=14.88； 深度7m处，N1=6+100×0.063×(1-2.718-0.3×6)=11.26； 打桩后5m处实际系数大于临界系数，则液化点只有4m及7m两个，液化指数为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]