[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978521":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},978521,706,1,"单选题","某淤泥质土场地，淤泥质土层厚度为10m，10m以下为基岩，场地中拟建建筑物采用筏形基础，基础埋深为2.0m，基础底面附加压力为300kPa，地表下10m处的附加应力为100kPa,地基采用粉体喷搅法处理，搅拌桩桩径为0.5m，桩间距为1.5m，三角形布桩，桩体材料压缩模量为300MPa，桩间土压缩模量为4MPa，该筏形基础的沉降量为（ ）mm。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","18",false,{"key":16,"text":17,"correct":14},"B","24",{"key":19,"text":20,"correct":14},"C","30",{"key":22,"text":23,"correct":24},"D","47",true,"根据《建筑地基处理技术规范》（JGJ 79—2002）第11. 2. 9条计算如下： de=1.05s = 1.05×1.5 = 1.575m； m=d2\u002Fd2e =0.52\u002F1.5752 =0. 101 ； Esp=mEp + (1-m)Es=0. 101×300 + (1-0. 101)×4 = 33. 9MPa，Ep、Es为分别为搅拌桩的压缩模量和桩间土的压缩模量。 式中，pz为搅拌桩复合土层顶面的附加 压力值；pz1搅拌桩复合土层底面的附加压力值。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]