[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978519":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},978519,706,1,"单选题","某建筑采用筏形基础底面尺寸为10m×20m，底面压力为220kPa，基础底面下设300mm褥垫层，基础埋深2.0m，勘察资料如下： I.0~10m,淤泥质土，y = 19.5kN\u002Fm3, qsk =7kPa, fak =80kPa, Es =8. 8MPa； II.10~20m，砂土，y= 18.5kN\u002Fin3, qsk=25kPa,fak =200kPa； III.地下水埋深2.0m。 采用深层搅拌法处理，桩按等边三角形布置，桩径为500mm,桩长9m,水泥掺入比为15% ,桩体平均强度fcu=2.8MPa，桩间土承载力折减系数为0.4,桩端天然地基土承载力折减系数0.5，桩身强度折减系数为0.33，按《建筑地基处理技术规范》（JGJ 79— 2002）计算。 (6)如水灰比为0.5，泵量为60L\u002Fmin,水泥密度为3t\u002Fm3，搅拌头提升速度不宜大于 ( )m\u002Fmin。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","1.06",false,{"key":16,"text":17,"correct":14},"B","1. 16",{"key":19,"text":20,"correct":21},"C","1.26",true,{"key":23,"text":24,"correct":14},"D","1.36","计算步骤如下：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]