[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978486":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},978486,706,1,"单选题","已知软塑黏性土场地采用高压喷射注浆法处理，正方形布桩，桩径为0.6m，桩长为 12m,桩间距为2.0m,由桩周土的强度确定向单桩承载力为800kN，桩间去承载力特征值为110kPa,折减系数为0.5，要求复合地基承载力不小于240kPa，桩身强度fcu不宜小于（ ）MPa。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","5.2",false,{"key":16,"text":17,"correct":14},"B","6.2",{"key":19,"text":20,"correct":14},"C","7.2",{"key":22,"text":23,"correct":24},"D","8.2",true,"根据《建筑地基处理技术规范》(JGJ 79—2002)第7. 2. 8条、第11. 2. 3 ~ 11. 2. 4 条及第9. 2. 5条，等效圆直径为：de=1. 13s = 1. 13×2. 0=2. 26m;置换率为：m=d2\u002Fd2e=0. 62\u002F2. 262 =0. 07。 则单桩竖向承载力特征值为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]