[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978434":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},978434,706,1,"单选题","某建筑场地地层如图5-3所示，拟采用水泥粉煤灰碎石桩（CFG柱）进行加固。已知基础埋深为2.0m, CFG桩长14.0m,桩径500mm,桩身强度fcu =20MPa，桩间土承载力折减系数取0. 8。按《建筑地基处理技术规范》（JGJ 79—2002）计算，如果复合地基承载力特征值要求达到180kPa,则CFG桩面积置换率m，应取下列哪个选项的数值？ ( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","10%",false,{"key":16,"text":17,"correct":18},"B","12%",true,{"key":20,"text":21,"correct":14},"C","1%",{"key":23,"text":24,"correct":14},"D","18%","根据《建筑地基处理技术规范》（JGJ 79—2002）第9. 2. 5条、第9.2.6条，",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]