[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978424":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},978424,706,1,"单选题","拟对厚度为10.0m的淤泥层进行预压法加固。已知淤泥面上铺设1.0m厚中粗砂垫层，再上覆厚的2.0m压实填土，地下水位与砂层顶面齐平，淤泥三轴固结不排水试验得到的黏聚力ccu=10.0kPa,内摩擦角φcu =9.5°，淤泥面处的天然抗剪强度τ0=12.3kPa， 中粗砂重度为20kN\u002Fm3，填土重度为18kN\u002Fm3，按《建筑地基处理技术规范》（JGJ79— 2002）计算，如果要使淤泥面处抗剪强度值提高50%，则要求该处的固结度至少达到以下哪个选项？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","60%",false,{"key":16,"text":17,"correct":14},"B","70%",{"key":19,"text":20,"correct":21},"C","80%",true,{"key":23,"text":24,"correct":14},"D","90%","根据《建筑地基处理技术规范》(JGJ79—2002)式(5. 2.11)， τft=τf0+Δσz·Uttanφcu 代入，1.5×12. 3 =12. 3 +[2×18+1×(20-10)]×Ut×tan9. 5°,解得Ut=80%。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]