[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978420":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},978420,706,1,"单选题","某多层厂房柱子柱脚尺寸800mm×1000mm，采用无筋扩展基础按荷载效应的标准组合计算，传至±0.0处的竖向力为Fk =600kN，力矩Mk =160kN·m，水平力Hk=35kN。 基底面积为2m×2. 6m,设计基础埋深1. 5m。基础材料采用C15混凝土。 (2)基础弯矩最大截面的弯矩设计值最接近（ ）kN ? m。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","100",false,{"key":16,"text":17,"correct":14},"B","140",{"key":19,"text":20,"correct":21},"C","170",true,{"key":23,"text":24,"correct":14},"D","190","根据题意计算如下：基底应力分布：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]