[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978364":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},978364,706,1,"单选题","某独立柱基尺寸为4m×4m，基础底面处的附加压力为130kPa，地基承载力特征值fak=180kPa,根据表3-8所提供的数据，采用分层总和法计算独立柱基的地基最终变形量，变形计算深度为基础底面下6.0m，沉降计算经验系数取ψs=0.4，根据以上条件计算得出的地基最终变形量最接近（ ）mm。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","17",false,{"key":16,"text":17,"correct":14},"B","15",{"key":19,"text":20,"correct":14},"C","13",{"key":22,"text":23,"correct":24},"D","11",true,"根据《建筑地基基础设计规范》（GB 50007—2002）第5. 3.5条计算，结果如表3-9所示。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]