[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978362":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},978362,706,1,"单选题","某办公楼基础尺寸42m×30m，采用箱形基础，基础埋深在室外地面以下8m，基底平均压力425kN\u002Fm2,场区土层的重度为20kN\u002Fm3，地下水水位埋深在室外地面以下5. 0m,地下水的重度为10kN\u002Fm3，计算得出的基础底面中心点以下深度18m处的附加应力与土的有效自重应力的比值最接近（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","0.55",false,{"key":16,"text":17,"correct":14},"B","0.60",{"key":19,"text":20,"correct":21},"C","0.65",true,{"key":23,"text":24,"correct":14},"D","0.70","根据题意计算如下： ①基础底面处自重应力为：pc1=∑yihi=5×20+3×10 = 130kPa; ②基础底面中心点以下深度18m处的自重应力为： pcz =∑yihi=5×20 +3×10 + 18×10 =310kPa； ③基础底面附加应力为：Po=pk-pc1=425-130=295kPa； ④m =l\u002F6 = （42\u002F2）\u002F（30\u002F2） =1.4，n =z\u002F6 = 18\u002F(30\u002F2) =1.2； 查《建筑地基基础设计规范》(GB 50007 — 2002)表K. 0.1-1得，附加应力系数α= 0. 171，则计算点处的附加应力为：px =4αPo =4 ×0.171×295 =201. 8kPa。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]