[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978179":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},978179,706,1,"单选题","一锚杆挡土墙肋柱如图6-29所示，其宽、高、厚分别为a=0.5m，H= 5.0m，b = 0.2m。打三层锚杆，锚杆支点处反力Rn均为150kN,锚杆对水平方向的倾角β均为10°，肋柱竖直倾角α为5°,重度y为25kN\u002Fm3。不考虑肋柱所受到的摩擦力和其他阻力的情况下，肋柱基底压应力σ估算结果为（ ）kPa。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","104",false,{"key":16,"text":17,"correct":14},"B","259",{"key":19,"text":20,"correct":14},"C","364",{"key":22,"text":23,"correct":24},"D","519",true,"肋柱基底总压力为： ∑N =3Rntan(β-α) +yabH = 3×150×tan( 10°-5°) +25×0.5×0.2×5 =51.9kN； 肋柱基底压应力为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]