[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978080":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},978080,706,1,"单选题","某一级建筑土质边坡采用永久性锚杆挡土墙支护，其平均水平土压力标准值为ehk= 20kPa,锚杆钢筋抗拉强度设计值fy=300N\u002Fmm2，锚杆间、排距分别为2.0m、2.5m, 倾角20°，锚杆钢筋与砂浆之间的黏结强度设计值fb= 2.1MPa,锚固体与土体间黏结强度特征值为30kPa。根据《建筑边坡工程技术规范》（GB 50330—2002）计算锚杆钢筋所需的最小直径为（ ）mm。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","22.9",false,{"key":16,"text":17,"correct":14},"B","29.6",{"key":19,"text":20,"correct":21},"C","30.6",true,{"key":23,"text":24,"correct":14},"D","31. 8","根据《建筑边坡工程技术规范》(GB 50330—2002)第7. 2. 1条、第7. 2. 2条、第8.2.5条及第9. 2. 1条， 锚杆水平拉力标准值：Htk=ehksxjsyj=20×2.0×2.5 = 100kN； 锚杆轴向拉力标准值：Nak=Htk\u002Fcosα= 100\u002Fcos20°= 106.4kN ； 锚杆轴向拉力设计值:Na=yQNak=1.3×106.4 = 138.32kN；",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]