[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978063":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},978063,706,1,"单选题","某建筑物的地质剖面及土性指标如图4 -37和表4-8所示。柱基顶面承受的最大荷载特征值为：轴力P= 2040kN，弯矩M = 320kN·m，剪力T = 56kN。根据方案比较择优选择了钢筋混凝土打入桩基础。采用平面尺寸为300mm×300mm的预制钢筋混凝土方桩。基础顶面高程为地表下0.8m，根据地质条件，确定第四层硬塑黏土为桩尖持力层。桩尖进入持力层1.55m，桩长8.0m，承台底面埋深1. 8m。桩数n=5根，边桩中心至承台边缘距离是d=0.3m,布置见图4-38所示。承台底面尺寸1. 6m×2. 6m。桩顶伸入承台50mm，钢筋保护层取35mm。建筑场地地层条件如下： ①粉质黏土层IL=0.6，取qsk=60kPa； qck =430kPa； ②饱和软黏土层：因e= 1. 10,属于淤泥质土，取qsk=26kPa； ③硬塑黏土层：IL=0.25，取qsk=80kPa,端土极限承载力标准值qpk=2500kPa。 (3)桩基中单桩的最大力Nmax为（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","532",true,{"key":16,"text":17,"correct":18},"B","555",false,{"key":20,"text":21,"correct":18},"C","583",{"key":23,"text":24,"correct":18},"D","612","根据《建筑桩基技术规范》（JGJ 94—2008）第5. 1. 1条，单桩所受的平均竖向作用力为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]