[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978031":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},978031,706,1,"单选题","某建筑物采用柱下桩基础，有6根钢筋混凝土预制桩，边长为400mm，桩长为22m，平面布置如图4-28所示。桩顶入土深度为2m，桩端入土深度24m，建筑桩基设计等级为乙级。假定由经验法估算得到单桩的总极限侧阻力标准值及极限端阻力标准值分别为1700kN和500kN，承台底部为厚层粉土，其极限承载力标准值为160kPa。考虑桩群、 土、承台相互作用效应，根据《建筑桩基技术规范》（JGJ 94—2008）计算非端承桩复合基桩竖向承载力特征值R，其值最接近（）kN。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","1.2×103",false,{"key":16,"text":17,"correct":14},"B","1.5×103",{"key":19,"text":20,"correct":14},"C","1.6×103",{"key":22,"text":23,"correct":24},"D","1.7×103",true,"",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]