[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978027":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},978027,706,1,"单选题","如图4-26所示，进行软弱下卧层强度验算，桩为直径400mm灌注桩，桩长l=9m，各层土的y均为20kN\u002Fm3，重要性系数y0=1。计算得软弱下卧层顶面处自重应力、附加应力及承载力特征值分别为（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","210kPa； 30kPa； 317kPa",false,{"key":16,"text":17,"correct":14},"B","210kPa； 30kPa； 327kPa",{"key":19,"text":20,"correct":21},"C","260kPa； 62kPa； 310kPa",true,{"key":23,"text":24,"correct":14},"D","220kPa； 41kPa； 317kPa","根据《建筑桩基技术规范》(JGJ 94—2008)第5. 4. 1条计算， ①已知桩距sa=1.2m，d=0.4m,因为sa\u002Fd=3＜6，故根据《建筑桩基技术规范》（JGJ 94一2008）式(5. 4. 1 -2)计算，软弱下卧层顶面处附加应力公式为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]