[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978017":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},978017,706,1,"单选题","有一桩基础，建筑场地土层分布见表4-6，第五层为持力层，桩尖进入持力层约1m，基桩的有效长度为20m，承台埋深2m，桩的截面尺寸为600mm×600mm。用静力触探法估算单桩承载力特征值，其大小最接近于（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","1657",true,{"key":16,"text":17,"correct":18},"B","2023",false,{"key":20,"text":21,"correct":18},"C","2600",{"key":23,"text":24,"correct":18},"D","2765","根据《建筑桩基技术规范》（JGJ 94—2008）第5. 3. 3条规定计算如下： ①各层土极限侧阻力标准值qsik为： 地表下6m范围内，极限侧阻力取qsik = 15kPa。 当深度大于 6m 时，若ps＜1000kPa，qsik=0.05Ps；若1000kPa＜ps＜4000kPa，qsik=0. 025ps +25；若ps＞4000kPa，qsik= 125kPa。 ②单桩总极限侧阻力计算公式为：Qpk=αPskAp。 式中，α为桩端阻力修正系数，根据桩入土深度取α=0.8；",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]