[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978011":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},978011,706,1,"单选题","某工程采用边长400mm预制混凝土方桩，有效桩长l=11.5m，承台埋深2. 5m,此场区单桥静力触探结果如图4-25所示。计算单桩竖向极限承载力标准值为（）kN。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","707",false,{"key":16,"text":17,"correct":14},"B","717",{"key":19,"text":20,"correct":14},"C","727",{"key":22,"text":23,"correct":24},"D","816",true,"根据《建筑桩基技术规范》（JGJ 94—2008）第5. 3. 3条，混凝土预制桩单桩竖向极限承载力标准值的计算公式为： Quk = Qsk +Qpk =u∑qsikli +αpskAp 式中，li为桩周第i层土的厚度。 计算过程如下： ①按规范图5.3. 3各层土极限侧阻力标准值qsik分别为： 地表下6m范围内，顶部3.5m；按图中（A）线，qsik=15kPa。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]