[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978007":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},978007,706,1,"单选题","某工程承台埋深1.5m,下设钢管桩直径700mm,壁厚10mm,桩长26.5m，桩端带隔板开口桩，n=2。土层分布情况为：0~3.0m填土，桩侧极限侧阻力标准值qsk=25kPa； 3.0~8.5m 黏土层，qsk =50kPa； 8. 5 ~25.0m 粉土层，qsk =65kPa； 25. 0 ~ 30.0m 中砂， qsk =75kPa； qpk =7000kPa,计算此钢管桩的竖向极限承载力为（ ）kN。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","3582",false,{"key":16,"text":17,"correct":14},"B","4618",{"key":19,"text":20,"correct":14},"C","5448",{"key":22,"text":23,"correct":24},"D","5693",true,"根据《建筑桩基技术规范》（JGJ 94—2008）第5. 3. 7条计算，开口管桩的单桩极限承载力的计算公式为： Quk =Qsk+QPk = u∑qsikli + λpqpkAp 式中，u为桩身周长；Ap为桩端面积。 对于带隔板的钢管桩，以等效直径dc代替d以确定λp。 由题计算可得等效直径为： 由于是带隔板的开口桩，应以等效直径代替d确定λp,则hb\u002Fd= 3. 0\u002F0. 495 =6.061＞5，所以取λp =0.8。将已知的数据代入上式得此钢管桩的竖向极限承载力为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]