[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-978005":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},978005,706,1,"单选题","某承台下设三根钻孔灌注桩（干作业），桩径为600mm，桩长11m，各层土的厚度、侧阻、端阻如图4-24所示，则计算得基桩承载力特征值为（ ）kN。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","650",true,{"key":16,"text":17,"correct":18},"B","760",false,{"key":20,"text":21,"correct":18},"C","770",{"key":23,"text":24,"correct":18},"D","780","根据《建筑桩基技术规范》（JGJ94—2008)第5. 3. 3条，土的总极限侧阻力的计算公式为：Qsk= u∑qsikli。式中，u为桩身周长；qsik为桩侧第i层土的极限侧阻力标准值；li为桩穿越第i层土的厚度。则土的总极限侧阻力为：Qsk =3. 14×0.6×(5×40+5×55 +1×70) =1026. 78kN，土的总极限端阻力的计算公式为：Qpk=qpkAp。式中，qpk为极限端阻力标准值；Ap为桩端面积。则土的极限端阻力为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]