[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-977989":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},977989,706,1,"单选题","某工程双桥静探资料见表4-3，拟采用③层粉砂做持力层，采用混凝土方桩，桩断面尺寸为400×400mm，桩长l= 13m，承台埋深为2.0m， 桩端进入粉砂层2. 0m，按《建筑桩基技术规范》（JGJ 94 — 2008）计算单桩竖向极限承载标准值最接近（ ）kN。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","1220",false,{"key":16,"text":17,"correct":14},"B","1580",{"key":19,"text":20,"correct":21},"C","1715",true,{"key":23,"text":24,"correct":14},"D","1900","根据《建筑桩基技术规范》(JGJ 94-2008)第5. 3. 4条计算，4d=4×0.4 = 1.6＜2.0m,所以qc=12000kPa，取α= 1\u002F2；则单桩竖向极限承载标准值为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]