[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-977983":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},977983,706,1,"单选题","某框架柱采用桩基础，承台下5根Φ=600mm的钻孔灌注桩，桩长l=15m，如图4-18 所示，承台顶处柱竖向轴力F = 3840kN，My=161kN·m，承台及其上覆土自重设计值 G=447kN,基桩最大竖向力Nmax为（ ）kN。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","831",false,{"key":16,"text":17,"correct":14},"B","858",{"key":19,"text":20,"correct":14},"C","886",{"key":22,"text":23,"correct":24},"D","902",true,"根据《建筑桩基技术规范》（JGJ 94—2008）第5. 1. 1条，偏心竖向力作用下，基桩竖向力按下式计算： 式中，Fk表示作用于桩基承台顶面的竖向力；Gk表示桩基承台的自重标准值；Mxk、 Myk表示承台底面的弯矩；Nik表示单桩桩顶竖向力；xi、yi表示第i复合基桩或基桩至x、y轴的距离；n表示桩基中的桩数。则竖向力最大值为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]