[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-977981":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},977981,706,1,"单选题","某端承灌注桩桩径1.0m，桩长22m,桩周土性参数如图4- 17所示，地面大面积堆载P=60kPa，桩周沉降变形土层下限深度20m，试按《建筑粧基技术规范》（JGJ 94—2008） 计算下拉荷载标准值，其值最接近（ ）kN。（已知黏土负摩阻力系数ζn=0.3，粉质黏土负摩阻力系数ζn=0.4,负摩阻力群桩效应系数ηn= 1.0）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","1880",false,{"key":16,"text":17,"correct":18},"B","2200",true,{"key":20,"text":21,"correct":14},"C","2510",{"key":23,"text":24,"correct":14},"D","3140","根据《建筑桩基技术规范》（JGJ94一2008）第5. 4. 4条，基桩的下拉荷载标准值计算如下： 查表5. 4. 4 -2可知中性点深度比为0. 9，则中性点深度为：ln=0. 9l0 =20×0. 9 = 18m； 平均竖向有效力为： 第一层土：σ′1=p+y1z1=60 + (18-10)×10\u002F2 = 100kPa； 第二层土： σ′2=p + y2z2 =60 + 8×10 + 10×8\u002F2 = 180kPa； 桩侧负摩阻力标准值为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]