[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-977977":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},977977,706,1,"单选题","某桩基工程的桩型平面布置、剖面及地层分布如图4-16所示，作用于桩端平面处的有效附加应力为400kPa，其中心点的附加压力曲线如图4 - 16 ( b)所示（假定为直线分布），沉降经验系数ψ= 1.0，地基沉降计算深度至基岩面，请按《建筑桩基技术规范》 (JGJ 94—2008)验算桩基最终沉降量，其计算结果最接近（ ）cm。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","3.6",false,{"key":16,"text":17,"correct":18},"B","6. 1",true,{"key":20,"text":21,"correct":14},"C","7.9",{"key":23,"text":24,"correct":14},"D","8.6","根据《建筑桩基技术规范》(JGJ 94-2008)第5. 5. 6 ~ 5. 5. 9条及附录E，对于桩中心距小于或等于6倍桩径的桩基，其最终沉降量计算可采用等效作用分层总和法，则按分层总和法计算出的桩基沉降量为：",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]