[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-977931":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},977931,706,1,"单选题","某灌注桩直径800mm,桩身露出地面的长度为10m，桩入土长度为20m，桩端嵌入较完整的坚硬岩石，桩的水平变形系数α为0.520( 1\u002Fm)，桩顶铰接，桩顶以下5m范围内箍筋间距为200mm，该桩轴心受压，桩顶轴向压力设计值为6800kN,成桩工艺系数ψc取 0.8，按《建筑桩基技术规范》（JGJ 94—2008），试问桩身混凝土轴心抗压强度设计值应不小于下列何项数值？（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","15MPa",false,{"key":16,"text":17,"correct":14},"B","17MPa",{"key":19,"text":20,"correct":21},"C","19MPa",true,{"key":23,"text":24,"correct":14},"D","21 MPa","根据《建筑桩基技术规范》(JGJ 94一2008)第5. 8. 2条第2款计算： N≤ψGfcAps 根据第5. 8. 4条，此为高承台基桩，应考虑压屈影响。 查表5. 8.4-1,桩底嵌于岩石之中，桩顶铰接，α=0.520。 h=20＞4\u002Fα=4\u002F0.520 =7.69，故lc =0. 7×(l0+4\u002Fα) =0. 7×(10 +4\u002F0. 520) =12.4m, lc\u002Fd= 12.4\u002F0. 8 = 15. 5，查表 5. 8. 4-2 得，φ=0.81； 代入得，fc≥6800×103\u002F(0. 81×0.8×π×0.42) =21×106Pa =21MPa。",{"id":6,"name":27,"category":28,"favorite":29},"岩土专业案例","建筑工程",0]