[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":446},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,8,50,2486,[13,34,46,61,74,87,100,112,124,136,148,160,172,184,197,210,222,234,245,255,261,267,273,279,285,291,297,303,309,315,321,327,333,339,345,351,357,363,369,375,381,387,393,399,405,411,417,423,429,435],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},973286,1,"单选题","为减少系统恢复时间，干式报警阀组报警功能建议利用（）进行测试。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","泄水试验阀",false,{"key":24,"text":25,"correct":22},"B","末端试水装置",{"key":27,"text":28,"correct":29},"C","警铃试验阀",true,{"key":31,"text":32,"correct":22},"D","信号阀","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},973287,"干式系统气压维持装置主要由（）组成，",[38,40,42,44],{"key":20,"text":39,"correct":22},"快充球阀、慢充球阀、安全阀",{"key":24,"text":41,"correct":29},"快充球阀、慢充球阀、过滤减压阀",{"key":27,"text":43,"correct":22},"快充球阀、慢充球阀",{"key":31,"text":45,"correct":22},"快充球阀、慢充球阀、止回阀",{"id":47,"libraryId":5,"type":48,"typeLabel":49,"stem":50,"options":51,"answer":60,"analysis":33},973288,2,"多选题","下列选项哪些是属于火灾自动报警系统的组成（）。",[52,54,56,58],{"key":20,"text":53,"correct":29},"火灾探测报警系统",{"key":24,"text":55,"correct":29},"消防联动控制系统",{"key":27,"text":57,"correct":29},"可燃气体探测",{"key":31,"text":59,"correct":22},"消防电话总机","ABC",{"id":62,"libraryId":5,"type":48,"typeLabel":49,"stem":63,"options":64,"answer":73,"analysis":33},973289,"常用的接地电阻测量仪器主要有（）种",[65,67,69,71],{"key":20,"text":66,"correct":22},"环形接地电阻测试仪",{"key":24,"text":68,"correct":29},"手摇式接地电阻测试仪",{"key":27,"text":70,"correct":29},"钳形接地电阻测试仪",{"key":31,"text":72,"correct":22},"电动式接地电阻测试仪","BC",{"id":75,"libraryId":5,"type":48,"typeLabel":49,"stem":76,"options":77,"answer":86,"analysis":33},973290,"测量火灾自动报警系统专用接地装置的接地电阻值时有哪些注意事项（）。",[78,80,82,84],{"key":20,"text":79,"correct":29},"禁止在有雷击或被测接地体带电时进行测量。",{"key":24,"text":81,"correct":22},"可将指针用手拨动到“0”平衡点时",{"key":27,"text":83,"correct":29},"当检流计指针缓慢移到“0”平衡点时，才能加快摇表手柄转速",{"key":31,"text":85,"correct":29},"严禁在检流计指针仍有较大偏转时加快手柄的转速。","ACD",{"id":88,"libraryId":5,"type":48,"typeLabel":49,"stem":89,"options":90,"answer":99,"analysis":33},973291,"使用钳形接地电阻测试仪测试火灾自动报警系统接地电阻值时有哪些注意事项（）。",[91,93,95,97],{"key":20,"text":92,"correct":29},"在校准过程中，不能张开钳头或钳住被测体。",{"key":24,"text":94,"correct":29},"当显示屏上出现杂讯符号“N。ISE”时，表示回路有干扰电流，此时的电阻测量值不准确。",{"key":27,"text":96,"correct":29},"保持钳口接触平面清洁。",{"key":31,"text":98,"correct":29},"应按照制造商提供的方法进行测试。","ABCD",{"id":101,"libraryId":5,"type":48,"typeLabel":49,"stem":102,"options":103,"answer":60,"analysis":33},973292,"末端试水装置由（）组成",[104,106,108,110],{"key":20,"text":105,"correct":29},"试水阀",{"key":24,"text":107,"correct":29},"压力表",{"key":27,"text":109,"correct":29},"试水接头",{"key":31,"text":111,"correct":22},"压力开关",{"id":113,"libraryId":5,"type":48,"typeLabel":49,"stem":114,"options":115,"answer":60,"analysis":33},973293,"消防应急广播扬声器的安装和设置有（）要求",[116,118,120,122],{"key":20,"text":117,"correct":29},"每个扬声器的额定功率不应小于3W。",{"key":24,"text":119,"correct":29},"客房设置专用扬声器时，其功率不宜小于1W。",{"key":27,"text":121,"correct":29},"在环境噪声大于60dB的场所设置的扬声器，在其播放范围内最远点的播放声压级应高于背景噪声15dB。",{"key":31,"text":123,"correct":22},"公共建筑内扬声器应设置在走道和大厅等公共场所",{"id":125,"libraryId":5,"type":48,"typeLabel":49,"stem":126,"options":127,"answer":99,"analysis":33},973294,"测试消防应急广播系统广播功能应测试（）。",[128,130,132,134],{"key":20,"text":129,"correct":29},"总线自动控制功能测试",{"key":24,"text":131,"correct":29},"紧急手动控制功能测试",{"key":27,"text":133,"correct":29},"分配盘的选层广播功能测试",{"key":31,"text":135,"correct":29},"合用广播系统应急强制切换功能测试",{"id":137,"libraryId":5,"type":48,"typeLabel":49,"stem":138,"options":139,"answer":60,"analysis":33},973295,"消防电话系统的检测内容（）。",[140,142,144,146],{"key":20,"text":141,"correct":29},"消防电话主机与电话分机、插孔电话之间的通话质量",{"key":24,"text":143,"correct":29},"电话主机的录音功能",{"key":27,"text":145,"correct":29},"拨打“119”功能",{"key":31,"text":147,"correct":22},"保存通话记录功能",{"id":149,"libraryId":5,"type":48,"typeLabel":49,"stem":150,"options":151,"answer":60,"analysis":33},973296,"消防电话系统的检测方法（）。",[152,154,156,158],{"key":20,"text":153,"correct":29},"用消防电话通话，检查通话效果",{"key":24,"text":155,"correct":29},"用插孔电话呼叫消防控室，检查通话效果",{"key":27,"text":157,"correct":29},"查看消防控制室、消防值班室、企业消防站等处的外线电话。",{"key":31,"text":159,"correct":22},"拨打“119”测试",{"id":161,"libraryId":5,"type":48,"typeLabel":49,"stem":162,"options":163,"answer":99,"analysis":33},973297,"消防电梯的安全设施包含（）。",[164,166,168,170],{"key":20,"text":165,"correct":29},"消防电梯前室应设置室内消火栓",{"key":24,"text":167,"correct":29},"消防电梯间前室或合用前室应设置防烟设施",{"key":27,"text":169,"correct":29},"消防电梯前室或合用前室应划分为单独探测区域，设火灾探测器和光警报器。",{"key":31,"text":171,"correct":29},"消防电梯应在轿顶设置一个轿厢安全窗",{"id":173,"libraryId":5,"type":48,"typeLabel":49,"stem":174,"options":175,"answer":99,"analysis":33},973298,"以下哪些符合水力警铃的设置要求（）。",[176,178,180,182],{"key":20,"text":177,"correct":29},"安装后的水力警铃启动时，警铃声压级应不小于70dB。",{"key":24,"text":179,"correct":29},"工作压力不应小于0．05MPa",{"key":27,"text":181,"correct":29},"应设在有人值班的地点附近或公共通道的外墙上，且应安装检修、测试用的阀门。",{"key":31,"text":183,"correct":29},"与报警阀连接的管道，其管径应为20mm，总长不宜大于20m。",{"id":185,"libraryId":5,"type":48,"typeLabel":49,"stem":186,"options":187,"answer":196,"analysis":33},973299,"以下哪些（）应采用压力开关控制稳压泵",[188,190,192,194],{"key":20,"text":189,"correct":29},"湿式系统",{"key":24,"text":191,"correct":29},"干式系统",{"key":27,"text":193,"correct":22},"雨淋系统",{"key":31,"text":195,"correct":22},"水幕系统","AB",{"id":198,"libraryId":5,"type":48,"typeLabel":49,"stem":199,"options":200,"answer":209,"analysis":33},973300,"湿式报警阀组报警功能的测试途径（）。",[201,203,205,207],{"key":20,"text":202,"correct":22},"电磁阀",{"key":24,"text":204,"correct":29},"末端试水装置测试",{"key":27,"text":206,"correct":29},"报警阀泄水阀测试",{"key":31,"text":208,"correct":29},"利用警铃试验阀测试","BCD",{"id":211,"libraryId":5,"type":48,"typeLabel":49,"stem":212,"options":213,"answer":73,"analysis":33},973301,"使用照度计测试应急照明灯具的照度要用到以下哪些按键（）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"HOME键",{"key":24,"text":217,"correct":29},"POWER键",{"key":27,"text":219,"correct":29},"HOLD键",{"key":31,"text":221,"correct":22},"STop键",{"id":223,"libraryId":5,"type":48,"typeLabel":49,"stem":224,"options":225,"answer":99,"analysis":33},973302,"下列哪几项属于探测器的设置和安装要求（）。",[226,228,230,232],{"key":20,"text":227,"correct":29},"型火灾探测器在探测区域内每区域至少应设置一只，保护面积与半径应符合要求。",{"key":24,"text":229,"correct":29},"点型火灾探测器的确认灯应面向便于人员核查的主要入口方向。",{"key":27,"text":231,"correct":29},"当梁突出顶棚的高度超过0．6m时，被梁隔断的每个梁间区域应至少设置一只探测器。",{"key":31,"text":233,"correct":29},"火灾探测器宜水平安装，当确需倾斜安装时，倾斜角不应大于45°",{"id":235,"libraryId":5,"type":48,"typeLabel":49,"stem":236,"options":237,"answer":60,"analysis":33},973303,"水力警铃的工作压力不应小于0．05MPa，并应符合下列规定：（）。",[238,240,242,243],{"key":20,"text":239,"correct":29},"应设在有人值班的地点附近或公共通道的外墙上，且应安装检修、测试用的阀门",{"key":24,"text":241,"correct":29},"与报警阀连接的管道，其管径应为20mm，总长不宜大于20m",{"key":27,"text":177,"correct":29},{"key":31,"text":244,"correct":22},"水力警铃应安装在不发生冰冻的场所。",{"id":246,"libraryId":5,"type":247,"typeLabel":248,"stem":249,"options":250,"answer":252,"analysis":33},973304,3,"判断题","专用测试管路设置在报警阀组系统侧，由控制阀、检测供水压力和流量的仪表、排水管道组成，其过水能力与系统启动后的过水能力一致。",[251,253],{"key":20,"text":252,"correct":29},"正确",{"key":24,"text":254,"correct":22},"错误",{"id":256,"libraryId":5,"type":247,"typeLabel":248,"stem":257,"options":258,"answer":252,"analysis":33},973305,"根据国家有关现行标准和规范要求，一组消防水泵的岀水管上应设置压力和流量检测装置或预留可供连接压力和流量检测装置的接口，每台消防水泵的出水管应设置试水管路。",[259,260],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":262,"libraryId":5,"type":247,"typeLabel":248,"stem":263,"options":264,"answer":254,"analysis":33},973306,"末端试水装置开启后，水流指示器、报警阀、水力警铃应动作，消防水泵应能启动。",[265,266],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":268,"libraryId":5,"type":247,"typeLabel":248,"stem":269,"options":270,"answer":252,"analysis":33},973309,"通过开启末端试水装置、报警阀泄水阀或专用测试管路等方式模拟喷头动作，使报警阀在压差作用下开启，压力水流入报警管路，压力开关动作后直接启动消防水泵。",[271,272],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":274,"libraryId":5,"type":247,"typeLabel":248,"stem":275,"options":276,"answer":254,"analysis":33},973310,"开启警铃试验阀，无法直接驱动压力开关动作并连锁启动消防水泵。",[277,278],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":280,"libraryId":5,"type":247,"typeLabel":248,"stem":281,"options":282,"answer":252,"analysis":33},973311,"火灾发生时应能在消防控制室将火灾疏散层的扬声器和公共广播扩音机强制转入消防应急广播状态。",[283,284],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":286,"libraryId":5,"type":247,"typeLabel":248,"stem":287,"options":288,"answer":254,"analysis":33},973312,"客房床头控制柜内设有服务性的音乐广播扬声器，但不具有消防应急广播功能",[289,290],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":292,"libraryId":5,"type":247,"typeLabel":248,"stem":293,"options":294,"answer":252,"analysis":33},973313,"消防应急广播民用建筑内扬声器应设置在走道和大厅等公共场所。每个扬声器的额定功率不应小于3W。",[295,296],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":298,"libraryId":5,"type":247,"typeLabel":248,"stem":299,"options":300,"answer":254,"analysis":33},973314,"消防应急广播在环境噪声大于60dB的场所设置的扬声器，在其播放范围内最远点的播放声压级应高于背景噪声10dB。",[301,302],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":304,"libraryId":5,"type":247,"typeLabel":248,"stem":305,"options":306,"answer":252,"analysis":33},973315,"消防应急广播客房设置专用扬声器时，其功率不宜小于1W。",[307,308],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":310,"libraryId":5,"type":247,"typeLabel":248,"stem":311,"options":312,"answer":254,"analysis":33},973316,"消防电话和电话插孔不需设置明显的永久性标识。",[313,314],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":316,"libraryId":5,"type":247,"typeLabel":248,"stem":317,"options":318,"answer":252,"analysis":33},973317,"消防水泵房、发电机房、配变电室、计算机网络机房、主要通风和空调机房、防排烟机房、灭火控制系统操作装置处或控制室、企业消防站、消防值班室、总调度室、消防电梯轿厢、消防电梯机房及其他与消防联动控制有关的且经常有人值班的机房应设置消防电话分机。",[319,320],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":322,"libraryId":5,"type":247,"typeLabel":248,"stem":323,"options":324,"answer":252,"analysis":33},973318,"设有手动火灾报警按钮或消火栓按钮等处宜设置电话插孔，并宜选择带有电话插孔的手动火灾报警按钮。",[325,326],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":328,"libraryId":5,"type":247,"typeLabel":248,"stem":329,"options":330,"answer":254,"analysis":33},973319,"除设置在仓库连廊、冷库穿堂或谷物筒仓工作塔内的消防电梯外，普通电梯应设置前室。",[331,332],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":334,"libraryId":5,"type":247,"typeLabel":248,"stem":335,"options":336,"answer":254,"analysis":33},973320,"消防电梯井、机房与相邻电梯井、机房之间应设置耐火极限不低于2h的防火隔墙，隔墙上的门应采用乙级防火门。",[337,338],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":340,"libraryId":5,"type":247,"typeLabel":248,"stem":341,"options":342,"answer":254,"analysis":33},973321,"消防电梯的井底应设置排水设施，排水井的容量不应小于2m3，排水泵的排水量不应小于5L\u002Fs，消防电梯间前室的门口宜设置挡水设施。",[343,344],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":346,"libraryId":5,"type":247,"typeLabel":248,"stem":347,"options":348,"answer":254,"analysis":33},973322,"消防电梯应能每层停靠，电梯的载重量不应小于800kg，电梯从首层至顶层的运行时间不宜大于50s（运行时间从消防电梯轿门关闭时开始算起）。",[349,350],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":352,"libraryId":5,"type":247,"typeLabel":248,"stem":353,"options":354,"answer":252,"analysis":33},973323,"消防电梯间前室或合用前室应设置防烟设施。",[355,356],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":358,"libraryId":5,"type":247,"typeLabel":248,"stem":359,"options":360,"answer":252,"analysis":33},973324,"消防电梯应在轿顶设置一个轿厢安全窗，通过轿厢安全窗进入轿厢内不应被永久性的设备或照明灯具阻碍，并应提供从消防电梯轿厢内能完全打开轿厢安全窗的方式。",[361,362],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":364,"libraryId":5,"type":247,"typeLabel":248,"stem":365,"options":366,"answer":252,"analysis":33},973326,"安全出口标志灯应安装在安全出口或疏散门内侧上方居中的位置。",[367,368],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":370,"libraryId":5,"type":247,"typeLabel":248,"stem":371,"options":372,"answer":252,"analysis":33},973327,"安全岀口标志灯受安装条件限制标志灯无法安装在门框上侧时，可安装在门的两侧，但门完全开启时标志灯不能被遮挡。",[373,374],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":376,"libraryId":5,"type":247,"typeLabel":248,"stem":377,"options":378,"answer":254,"analysis":33},973328,"安全岀口标志灯采用吸顶或吊装式安装时，标志灯距安全出口或疏散门所在墙面的距离不宜大于30mm。",[379,380],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":382,"libraryId":5,"type":247,"typeLabel":248,"stem":383,"options":384,"answer":254,"analysis":33},973329,"安全岀口标志灯距安全出口或疏散门所在墙面的距离不宜大于30mm。",[385,386],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":388,"libraryId":5,"type":247,"typeLabel":248,"stem":389,"options":390,"answer":252,"analysis":33},973330,"方向标志灯安装在疏散走道、通道上方时，室内高度不大于3．5m的场所，标志灯底边距地面的高度宜为2．2～2．5m。",[391,392],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":394,"libraryId":5,"type":247,"typeLabel":248,"stem":395,"options":396,"answer":252,"analysis":33},973331,"方向标志灯与转角处边墙的距离不应大于2m。",[397,398],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":400,"libraryId":5,"type":247,"typeLabel":248,"stem":401,"options":402,"answer":252,"analysis":33},973332,"当楼层标志灯安装在疏散走道、通道的地面上时，应安装在疏散走道、通道的中心位置。",[403,404],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":406,"libraryId":5,"type":247,"typeLabel":248,"stem":407,"options":408,"answer":252,"analysis":33},973333,"消防应急照明和疏散指示系统的检测内容主要是：切断正常供电，测量消防应急灯具照度，测试电源切换、充电、放电功能，测试应急电源的供电时间；通过报警联动，检查消防应急灯具自动投入功能。",[409,410],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":412,"libraryId":5,"type":247,"typeLabel":248,"stem":413,"options":414,"answer":254,"analysis":33},973334,"钢质防火卷帘帘板两端挡板或防窜机构应装配牢固，卷帘运行时，相邻帘板窜动量不应大于3mm。",[415,416],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":418,"libraryId":5,"type":247,"typeLabel":248,"stem":419,"options":420,"answer":254,"analysis":33},973335,"防火卷帘控制器及手动按钮盒的安装应牢固可靠，其底边距地面高度宜为1．2～1．5m。",[421,422],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":424,"libraryId":5,"type":247,"typeLabel":248,"stem":425,"options":426,"answer":252,"analysis":33},973336,"除特殊情况外，防火门应向疏散方向开启，防火门在关闭后应能从任何一侧手动开启。",[427,428],{"key":20,"text":252,"correct":29},{"key":24,"text":254,"correct":22},{"id":430,"libraryId":5,"type":247,"typeLabel":248,"stem":431,"options":432,"answer":254,"analysis":33},973337,"高位消防水池设置在建筑物内时，应采用耐火极限不低于2．00h的隔墙和1．50h的楼板与其他部位隔开，并应设乙级防火门，且消防水池及其支承框架与建筑构件应连接牢固。",[433,434],{"key":20,"text":252,"correct":22},{"key":24,"text":254,"correct":29},{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":20,"analysis":33},973338,"火灾自动报警系统一般由火灾探测报警系统、消防联动控制系统、（）和电气火灾监控系统等全部或部分构成。",[439,441,443,445],{"key":20,"text":440,"correct":29},"可燃气体探测报警系统",{"key":24,"text":442,"correct":22},"控制模块",{"key":27,"text":444,"correct":22},"集中型应急照明系统",{"key":31,"text":195,"correct":22},[447,450,453,456,459,462],{"id":15,"name":448,"category":7,"favorite":449},"领导干部任职前廉政法规知识测试题",92,{"id":451,"name":452,"category":7,"favorite":15},595,"建筑结构与设备",{"id":454,"name":455,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":457,"name":458,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":460,"name":461,"category":7,"favorite":8},534,"BIM工程师",{"id":463,"name":461,"category":7,"favorite":8},535]