[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":480},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,7,50,2486,[13,34,46,60,73,83,89,95,101,107,113,119,125,131,137,143,149,155,161,167,173,179,185,191,197,203,217,225,236,248,260,272,281,293,301,313,322,331,343,355,367,379,388,400,412,422,434,446,457,468],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},973236,2,"多选题","对于可能造成消火栓出水口平时有水渗出的原因，可采取的维修方法有（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","关严消火栓",true,{"key":24,"text":25,"correct":22},"B","更换阀瓣胶垫",{"key":27,"text":28,"correct":22},"C","疏通排水阀",{"key":30,"text":31,"correct":22},"D","拆开并清除阀瓣处异物","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":32,"analysis":33},973237,"洒水喷头按安装位置和水的分布分（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"下垂型喷头",{"key":24,"text":41,"correct":22},"直立型喷头",{"key":27,"text":43,"correct":22},"边墙型喷头",{"key":30,"text":45,"correct":22},"通用型喷头",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":59,"analysis":33},973238,"对于可能造成报警管路误报警的原因，维修方法有（）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"按照安装图纸核对报警阀组组件安装情况，重新对报警阀组准工作状态进行调试。",{"key":24,"text":53,"correct":22},"按照故障1查找渗漏原因，进行相应处理",{"key":27,"text":55,"correct":22},"卸下延迟器筒体，拆下孔板进行清洗",{"key":30,"text":57,"correct":58},"维修或更换复位弹簧",false,"ABC",{"id":61,"libraryId":5,"type":15,"typeLabel":16,"stem":62,"options":63,"answer":72,"analysis":33},973239,"灭火器在再充装时必须要更换的零部件有（）。",[64,66,68,70],{"key":20,"text":65,"correct":58},"喷射软管",{"key":24,"text":67,"correct":22},"密封片",{"key":27,"text":69,"correct":22},"密封圈",{"key":30,"text":71,"correct":22},"密封垫","BCD",{"id":74,"libraryId":5,"type":75,"typeLabel":76,"stem":77,"options":78,"answer":82,"analysis":33},973240,3,"判断题","用软布沾水直接擦拭探测器积尘。（）",[79,81],{"key":20,"text":80,"correct":58},"正确",{"key":24,"text":82,"correct":22},"错误",{"id":84,"libraryId":5,"type":75,"typeLabel":76,"stem":85,"options":86,"answer":82,"analysis":33},973241,"报警按钮检测后使用专用复位钥匙将报警按钮复位即可。（）",[87,88],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":90,"libraryId":5,"type":75,"typeLabel":76,"stem":91,"options":92,"answer":80,"analysis":33},973242,"报警管路警铃试验阀处渗漏会造成湿式报警阀组漏水。（）",[93,94],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":96,"libraryId":5,"type":75,"typeLabel":76,"stem":97,"options":98,"answer":80,"analysis":33},973243,"充气管路连接处松动可导致干式系统空压机启动频繁。（）",[99,100],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":102,"libraryId":5,"type":75,"typeLabel":76,"stem":103,"options":104,"answer":80,"analysis":33},973244,"若因报警管路控制阀被关闭从而导致水力警铃工作不正常，把报警管路控制阀保持常开即可。（）",[105,106],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":108,"libraryId":5,"type":75,"typeLabel":76,"stem":109,"options":110,"answer":80,"analysis":33},973245,"止回阀的损坏造成消防水泵接合器漏水，维修或更换止回阀可使接合器不漏水。（）",[111,112],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":114,"libraryId":5,"type":75,"typeLabel":76,"stem":115,"options":116,"answer":80,"analysis":33},973246,"更换湿式报警阀组压力开关时要关闭报警阀报警管路控制阀，确认警铃试验阀处于关闭状态。（）",[117,118],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":120,"libraryId":5,"type":75,"typeLabel":76,"stem":121,"options":122,"answer":80,"analysis":33},973247,"防火门门扇无法开启可能因为闭门器损坏。（）",[123,124],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":126,"libraryId":5,"type":75,"typeLabel":76,"stem":127,"options":128,"answer":80,"analysis":33},973248,"压力开关损坏或设定不正确会导致稳压装置不能稳压。（）",[129,130],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":132,"libraryId":5,"type":75,"typeLabel":76,"stem":133,"options":134,"answer":82,"analysis":33},973249,"连接消防水鹤的市政给水管管径不宜小于DN100。（）",[135,136],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":138,"libraryId":5,"type":75,"typeLabel":76,"stem":139,"options":140,"answer":80,"analysis":33},973250,"干粉型灭火器超过出厂期满5年或首次维修以后每满2年进行维修。（）",[141,142],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":144,"libraryId":5,"type":75,"typeLabel":76,"stem":145,"options":146,"answer":82,"analysis":33},973251,"无论灭火器是否被使用过，拆卸瓶头阀门前一定要先卸压，瓶头阀门顶部朝向不做要求。（）",[147,148],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":150,"libraryId":5,"type":75,"typeLabel":76,"stem":151,"options":152,"answer":82,"analysis":33},973252,"在灭火器再充装时可以把钢瓶中原先没用完的灭火剂再次使用。（）",[153,154],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":156,"libraryId":5,"type":75,"typeLabel":76,"stem":157,"options":158,"answer":82,"analysis":33},973253,"在灭火器再充装操作时必须更换的零部件有喷射软管、虹吸管和密封片。（）",[159,160],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":162,"libraryId":5,"type":75,"typeLabel":76,"stem":163,"options":164,"answer":80,"analysis":33},973254,"水基型灭火器和干粉型灭火器在维修充装过程中，相应受压零部件应逐个进行水压试验。（）",[165,166],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":168,"libraryId":5,"type":75,"typeLabel":76,"stem":169,"options":170,"answer":82,"analysis":33},973255,"防火阀和排烟防火阀结构原理相同，所以动作温度也相同。（）",[171,172],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":174,"libraryId":5,"type":75,"typeLabel":76,"stem":175,"options":176,"answer":80,"analysis":33},973256,"挡烟垂壁不能自动启动可能因为配用探测器发生了故障。（）",[177,178],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":180,"libraryId":5,"type":75,"typeLabel":76,"stem":181,"options":182,"answer":80,"analysis":33},973257,"灭火器的压力计量仪器精度等级不小于1．6级的压力．（）",[183,184],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":186,"libraryId":5,"type":75,"typeLabel":76,"stem":187,"options":188,"answer":82,"analysis":33},973258,"用于干粉灭火器的驱动气体的露点不应高于-50℃。（）",[189,190],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":192,"libraryId":5,"type":75,"typeLabel":76,"stem":193,"options":194,"answer":80,"analysis":33},973259,"灌装不同型号的水基型灭火剂时，应用清水将灌装设备的容器和管道清洗干净。（）",[195,196],{"key":20,"text":80,"correct":22},{"key":24,"text":82,"correct":58},{"id":198,"libraryId":5,"type":75,"typeLabel":76,"stem":199,"options":200,"answer":82,"analysis":33},973260,"用于ABC干粉灭火剂和BC干粉灭火剂的灌装设备可以共同使用，充装场地可不用分开。（）",[201,202],{"key":20,"text":80,"correct":58},{"key":24,"text":82,"correct":22},{"id":204,"libraryId":5,"type":205,"typeLabel":206,"stem":207,"options":208,"answer":30,"analysis":33},973261,1,"单选题","感温火灾探测器的安装间距不应超过（）m。",[209,211,213,215],{"key":20,"text":210,"correct":58},"15",{"key":24,"text":212,"correct":58},"20",{"key":27,"text":214,"correct":58},"5",{"key":30,"text":216,"correct":22},"10",{"id":218,"libraryId":5,"type":205,"typeLabel":206,"stem":219,"options":220,"answer":20,"analysis":33},973262,"感烟火灾探测器的安装间距不应超过（）m。",[221,222,223,224],{"key":20,"text":210,"correct":22},{"key":24,"text":212,"correct":58},{"key":27,"text":214,"correct":58},{"key":30,"text":216,"correct":58},{"id":226,"libraryId":5,"type":205,"typeLabel":206,"stem":227,"options":228,"answer":27,"analysis":33},973263,"线型红外光束感烟火灾探测器的安装，相邻两组探测器光束轴线的水平距离不应大于（）m。",[229,231,232,234],{"key":20,"text":230,"correct":58},"16",{"key":24,"text":210,"correct":58},{"key":27,"text":233,"correct":22},"14",{"key":30,"text":235,"correct":58},"13",{"id":237,"libraryId":5,"type":205,"typeLabel":206,"stem":238,"options":239,"answer":20,"analysis":33},973264,"手动报警按钮每个防火分区应至少设置（）只",[240,242,244,246],{"key":20,"text":241,"correct":22},"一",{"key":24,"text":243,"correct":58},"二",{"key":27,"text":245,"correct":58},"三",{"key":30,"text":247,"correct":58},"四",{"id":249,"libraryId":5,"type":205,"typeLabel":206,"stem":250,"options":251,"answer":20,"analysis":33},973265,"每个报警区域内应均匀设置火灾警报器，其声压级不应小于（）dB。",[252,254,256,258],{"key":20,"text":253,"correct":22},"60",{"key":24,"text":255,"correct":58},"55",{"key":27,"text":257,"correct":58},"50",{"key":30,"text":259,"correct":58},"45",{"id":261,"libraryId":5,"type":205,"typeLabel":206,"stem":262,"options":263,"answer":20,"analysis":33},973266,"切断（），查看备用直流电源自动投入和主、备电源的状态显示情况",[264,266,268,270],{"key":20,"text":265,"correct":22},"主电源",{"key":24,"text":267,"correct":58},"备电源",{"key":27,"text":269,"correct":58},"应急电源",{"key":30,"text":271,"correct":58},"消防用电",{"id":273,"libraryId":5,"type":205,"typeLabel":206,"stem":274,"options":275,"answer":24,"analysis":33},973267,"断路故障报警期间，采用发烟装置或温度不低于（）℃的热源，先后向同一回路中两个火灾探测器施放烟气或加热，查看火灾报警控制器的火警信号、报警部位显示及记录。",[276,277,279,280],{"key":20,"text":253,"correct":58},{"key":24,"text":278,"correct":22},"54",{"key":27,"text":257,"correct":58},{"key":30,"text":259,"correct":58},{"id":282,"libraryId":5,"type":205,"typeLabel":206,"stem":283,"options":284,"answer":30,"analysis":33},973268,"火灾报警控制器和（），应设置在消防控制室内或有人值班的房间和场所。",[285,287,289,291],{"key":20,"text":286,"correct":58},"电气检测系统",{"key":24,"text":288,"correct":58},"可燃气体探测系统",{"key":27,"text":290,"correct":58},"防火门监控",{"key":30,"text":292,"correct":22},"消防联动控制器",{"id":294,"libraryId":5,"type":205,"typeLabel":206,"stem":295,"options":296,"answer":30,"analysis":33},973269,"（）应能按设定的控制逻辑向各相关受控设备发出联动控制信号，并接收相关设备的联动反馈信号。",[297,298,299,300],{"key":20,"text":286,"correct":58},{"key":24,"text":288,"correct":58},{"key":27,"text":290,"correct":58},{"key":30,"text":292,"correct":22},{"id":302,"libraryId":5,"type":205,"typeLabel":206,"stem":303,"options":304,"answer":27,"analysis":33},973270,"排烟风机入口处的总管上设置的（）排烟防火阀在关闭后应直接联动控制风机停止。",[305,307,309,311],{"key":20,"text":306,"correct":58},"70℃",{"key":24,"text":308,"correct":58},"80℃",{"key":27,"text":310,"correct":22},"280℃",{"key":30,"text":312,"correct":58},"150℃",{"id":314,"libraryId":5,"type":205,"typeLabel":206,"stem":315,"options":316,"answer":20,"analysis":33},973271,"消防应急广播系统的联动控制信号应由（）发出，当确认火灾后，应同时向全楼进行广播。",[317,318,319,320],{"key":20,"text":292,"correct":22},{"key":24,"text":288,"correct":58},{"key":27,"text":290,"correct":58},{"key":30,"text":321,"correct":58},"火灾报警控制器",{"id":323,"libraryId":5,"type":205,"typeLabel":206,"stem":324,"options":325,"answer":30,"analysis":33},973272,"集中控制型消防应急照明和疏散指示系统，应由（）或消防联动控制器启动应急照明控制器实现。",[326,327,328,330],{"key":20,"text":292,"correct":58},{"key":24,"text":288,"correct":58},{"key":27,"text":329,"correct":58},"防火门监控系统",{"key":30,"text":321,"correct":22},{"id":332,"libraryId":5,"type":205,"typeLabel":206,"stem":333,"options":334,"answer":27,"analysis":33},973273,"手摇式接地电阻测试仪测试时，缓慢转动手柄，若检流计指针从中间的“0”平衡点迅速向右偏转，说明原量程挡位选择过大，可将挡位选择至（）挡位。",[335,337,339,341],{"key":20,"text":336,"correct":58},"X1．5",{"key":24,"text":338,"correct":58},"X2",{"key":27,"text":340,"correct":22},"X1",{"key":30,"text":342,"correct":58},"X4",{"id":344,"libraryId":5,"type":205,"typeLabel":206,"stem":345,"options":346,"answer":24,"analysis":33},973274,"管道的安装位置应符合设计要求。公称直径大于或等于100mm的管道其距离顶板、墙面的安装距离不宜小于（）mm。",[347,349,351,353],{"key":20,"text":348,"correct":58},"100",{"key":24,"text":350,"correct":22},"200",{"key":27,"text":352,"correct":58},"150",{"key":30,"text":354,"correct":58},"220",{"id":356,"libraryId":5,"type":205,"typeLabel":206,"stem":357,"options":358,"answer":24,"analysis":33},973275,"管道支架、吊架、防晃支架的型式、材质、加工尺寸及焊接质量、固定方式及设置间距等符合消防技术标准规定，安装位置不应妨碍（）的喷水效果。",[359,361,363,365],{"key":20,"text":360,"correct":58},"湿式系统",{"key":24,"text":362,"correct":22},"喷头",{"key":27,"text":364,"correct":58},"雨淋系统",{"key":30,"text":366,"correct":58},"水幕系统",{"id":368,"libraryId":5,"type":205,"typeLabel":206,"stem":369,"options":370,"answer":24,"analysis":33},973276,"配水干管、配水管应做红色或红色环圈标识。红色环圈标识宽度不应小于20mm，间隔不宜大于4m，在一个独立的单元内环圈标识不宜少于（）处。",[371,373,375,377],{"key":20,"text":372,"correct":58},"1",{"key":24,"text":374,"correct":22},"2",{"key":27,"text":376,"correct":58},"3",{"key":30,"text":378,"correct":58},"4",{"id":380,"libraryId":5,"type":205,"typeLabel":206,"stem":381,"options":382,"answer":24,"analysis":33},973277,"湿式系统一个报警阀组控制的洒水喷头数不宜超过800只，（）不宜超过500只。",[383,384,386,387],{"key":20,"text":360,"correct":58},{"key":24,"text":385,"correct":22},"干式系统",{"key":27,"text":364,"correct":58},{"key":30,"text":366,"correct":58},{"id":389,"libraryId":5,"type":205,"typeLabel":206,"stem":390,"options":391,"answer":20,"analysis":33},973278,"湿式系统一个报警阀组控制的洒水喷头数不宜超过800只，干式系统不宜超过（）只。",[392,394,396,398],{"key":20,"text":393,"correct":22},"500",{"key":24,"text":395,"correct":58},"1000",{"key":27,"text":397,"correct":58},"800",{"key":30,"text":399,"correct":58},"6",{"id":401,"libraryId":5,"type":205,"typeLabel":206,"stem":402,"options":403,"answer":20,"analysis":33},973279,"水力警铃的工作压力不应小于（）MPa",[404,406,408,410],{"key":20,"text":405,"correct":22},"0．05",{"key":24,"text":407,"correct":58},"0．03",{"key":27,"text":409,"correct":58},"0．06",{"key":30,"text":411,"correct":58},"0．07",{"id":413,"libraryId":5,"type":205,"typeLabel":206,"stem":414,"options":415,"answer":20,"analysis":33},973280,"水力警铃与报警阀连接的管道，其管径应为20mm，总长不宜大于（）m。",[416,417,419,421],{"key":20,"text":212,"correct":22},{"key":24,"text":418,"correct":58},"30",{"key":27,"text":420,"correct":58},"40",{"key":30,"text":257,"correct":58},{"id":423,"libraryId":5,"type":205,"typeLabel":206,"stem":424,"options":425,"answer":24,"analysis":33},973281,"（）应安装在不发生冰冻的场所。",[426,428,430,432],{"key":20,"text":427,"correct":58},"湿式报警阀组",{"key":24,"text":429,"correct":22},"干式报警阀组",{"key":27,"text":431,"correct":58},"雨淋报警阀组",{"key":30,"text":433,"correct":58},"预作用报警阀组",{"id":435,"libraryId":5,"type":205,"typeLabel":206,"stem":436,"options":437,"answer":30,"analysis":33},973282,"仓库内顶板下洒水喷头与货架内置洒水喷头应分别设置（）。",[438,440,442,444],{"key":20,"text":439,"correct":58},"压力开关",{"key":24,"text":441,"correct":58},"信号阀",{"key":27,"text":443,"correct":58},"止回阀",{"key":30,"text":445,"correct":22},"水流指示器",{"id":447,"libraryId":5,"type":205,"typeLabel":206,"stem":448,"options":449,"answer":27,"analysis":33},973283,"末端试水装置应由（）、压力表以及试水接头组成。",[450,452,453,455],{"key":20,"text":451,"correct":58},"安全阀",{"key":24,"text":443,"correct":58},{"key":27,"text":454,"correct":22},"试水阀",{"key":30,"text":456,"correct":58},"控制阀",{"id":458,"libraryId":5,"type":205,"typeLabel":206,"stem":459,"options":460,"answer":27,"analysis":33},973284,"末端试水装置的出水，应采取孔口出流的方式排入排水管道，排水立管宜设伸顶通气管，且管径不应小于（）mm。",[461,462,464,466],{"key":20,"text":348,"correct":58},{"key":24,"text":463,"correct":58},"85",{"key":27,"text":465,"correct":22},"75",{"key":30,"text":467,"correct":58},"65",{"id":469,"libraryId":5,"type":205,"typeLabel":206,"stem":470,"options":471,"answer":20,"analysis":33},973285,"湿式报警阀组报警功能可通过（）等途径进行测试。",[472,474,476,478],{"key":20,"text":473,"correct":22},"末端试水装置、专用测试管路、报警阀泄水阀、警铃试验阀",{"key":24,"text":475,"correct":58},"专用测试管路、报警阀泄水阀、警铃试验阀",{"key":27,"text":477,"correct":58},"末端试水装置、专用测试管路、报警阀泄水阀、",{"key":30,"text":479,"correct":58},"末端试水装置、专用测试管路、报警阀泄水阀、复位阀",[481,484,487,490,493,496],{"id":205,"name":482,"category":7,"favorite":483},"领导干部任职前廉政法规知识测试题",92,{"id":485,"name":486,"category":7,"favorite":205},595,"建筑结构与设备",{"id":488,"name":489,"category":7,"favorite":205},715,"招标采购专业知识与法律法规",{"id":491,"name":492,"category":7,"favorite":205},848,"市政方向-通用基础",{"id":494,"name":495,"category":7,"favorite":8},534,"BIM工程师",{"id":497,"name":495,"category":7,"favorite":8},535]