[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":488},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,6,50,2486,[13,34,48,61,73,85,97,109,119,125,131,137,143,149,155,161,167,173,179,185,191,197,203,209,215,221,227,233,239,245,251,265,277,289,300,312,324,336,347,359,371,382,394,406,419,429,440,451,464,476],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},973186,2,"多选题","以下属于常开式防火门无法正常关闭的原因是（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","电磁释放器无法消磁",true,{"key":24,"text":25,"correct":22},"B","闭门器损坏",{"key":27,"text":28,"correct":22},"C","闭门器、连杆安装角度不正确",{"key":30,"text":31,"correct":22},"D","模块损坏","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":47,"analysis":33},973187,"对于可能造成消防应急广播无法应急启动的原因，维修方法有（）。",[38,40,42,45],{"key":20,"text":39,"correct":22},"修复通信线路或更换广播控制器",{"key":24,"text":41,"correct":22},"重新导入应急广播的音源文件",{"key":27,"text":43,"correct":44},"修复话筒按钮",false,{"key":30,"text":46,"correct":22},"査找功率放大器线路故障并修复或更换功率放大器","ABD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":33},973188,"以下（）会导致消防水箱没水。",[52,54,56,58],{"key":20,"text":53,"correct":44},"未安装就地液位显示装置",{"key":24,"text":55,"correct":22},"进水管浮球阀或液位控制阀损坏",{"key":27,"text":57,"correct":44},"液位报警装置发生报警故障",{"key":30,"text":59,"correct":22},"排污管(放空管)上控制阀未关闭","BD",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":32,"analysis":33},973189,"对于可能造成无法通过消防水泵接合器向室内管网供水的原因，维修方法有（）。",[65,67,69,71],{"key":20,"text":66,"correct":22},"釆取可靠的防冻措施",{"key":24,"text":68,"correct":22},"非施工安装或维修作业，水泵接合器控制阀必须完全打开",{"key":27,"text":70,"correct":22},"按正确方向重新安装止回阀",{"key":30,"text":72,"correct":22},"正确设置给水系统和分区标识，根据拟供水系统正确选择消防水泵接合器",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":32,"analysis":33},973190,"风机运行温度异常的原因有（）。",[77,79,81,83],{"key":20,"text":78,"correct":22},"润滑油脂不够",{"key":24,"text":80,"correct":22},"风机内部、叶轮积灰",{"key":27,"text":82,"correct":22},"供电线路电线截面过小",{"key":30,"text":84,"correct":22},"流量超过额定值",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":32,"analysis":33},973191,"维修灭火器需具备基本的保障条件有（）。",[89,91,93,95],{"key":20,"text":90,"correct":22},"维修场所",{"key":24,"text":92,"correct":22},"维修设备",{"key":27,"text":94,"correct":22},"维修人员",{"key":30,"text":96,"correct":22},"维修质量管理制度",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":32,"analysis":33},973192,"对于可能造成干式报警阀自动滴水阀滴漏不止的原因，维修方法有（）。",[101,103,105,107],{"key":20,"text":102,"correct":22},"完全关闭注水阀",{"key":24,"text":104,"correct":22},"更换密封圈",{"key":27,"text":106,"correct":22},"清除阀座上的异物",{"key":30,"text":108,"correct":22},"关严或更换警铃试验阀",{"id":110,"libraryId":5,"type":111,"typeLabel":112,"stem":113,"options":114,"answer":116,"analysis":33},973193,3,"判断题","由于火灾警报装置、模块等为有源器件，对其更换维修时要格外小心，非专业人员不要随意拆卸火灾警报装置。（）",[115,117],{"key":20,"text":116,"correct":22},"正确",{"key":24,"text":118,"correct":44},"错误",{"id":120,"libraryId":5,"type":111,"typeLabel":112,"stem":121,"options":122,"answer":118,"analysis":33},973194,"湿式报警阀开启后报警管路不排水可能是节流孔堵塞。（）",[123,124],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":126,"libraryId":5,"type":111,"typeLabel":112,"stem":127,"options":128,"answer":118,"analysis":33},973195,"只要消防控制室多线控制盘处于“手动允许”状态即可远程启停消防水泵，消防泵组电气控制柜所处情况不用管。（）",[129,130],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":132,"libraryId":5,"type":111,"typeLabel":112,"stem":133,"options":134,"answer":116,"analysis":33},973196,"管网有泄漏较大导致稳压泵启动频繁。（）",[135,136],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":138,"libraryId":5,"type":111,"typeLabel":112,"stem":139,"options":140,"answer":118,"analysis":33},973197,"严寒地区对消防水箱和消防水池无需采取防冻措施。（）",[141,142],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":144,"libraryId":5,"type":111,"typeLabel":112,"stem":145,"options":146,"answer":118,"analysis":33},973198,"为图方便拆装新旧洒水喷头用手直接施拧喷头框架即可。（）",[147,148],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":150,"libraryId":5,"type":111,"typeLabel":112,"stem":151,"options":152,"answer":118,"analysis":33},973199,"开式喷头是具有释放机构的洒水喷头。（）",[153,154],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":156,"libraryId":5,"type":111,"typeLabel":112,"stem":157,"options":158,"answer":118,"analysis":33},973200,"玻璃球喷头的工作液为绿色其动作温度是68℃。（）",[159,160],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":162,"libraryId":5,"type":111,"typeLabel":112,"stem":163,"options":164,"answer":116,"analysis":33},973201,"特殊响应喷头是指平均响应时间系数(RTI)介于50～80(m·s)0．5。（）",[165,166],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":168,"libraryId":5,"type":111,"typeLabel":112,"stem":169,"options":170,"answer":116,"analysis":33},973202,"消防电话分机与底座意外脱落可造成分机不断呼叫电话主机。（）",[171,172],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":174,"libraryId":5,"type":111,"typeLabel":112,"stem":175,"options":176,"answer":116,"analysis":33},973203,"光源故障包括消防应急照明灯应急时不亮、消防应急标志灯不亮、照明灯光源不亮、标志灯光源损坏等。（）",[177,178],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":180,"libraryId":5,"type":111,"typeLabel":112,"stem":181,"options":182,"answer":116,"analysis":33},973204,"电动闭门器滑槽内锁舌损坏导致常开式防火门无法锁定在开启状态，则需要更换滑槽即可。（）",[183,184],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":186,"libraryId":5,"type":111,"typeLabel":112,"stem":187,"options":188,"answer":118,"analysis":33},973205,"在拆卸灭火器瓶头阀门时应连续快速的旋开连接螺纹，直到完全旋开。（）",[189,190],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":192,"libraryId":5,"type":111,"typeLabel":112,"stem":193,"options":194,"answer":116,"analysis":33},973206,"若只因消防联动控制器处于“自动禁止”状态导致风机不能自动启动，则只需调整为“自动允许”状态即可。（）",[195,196],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":198,"libraryId":5,"type":111,"typeLabel":112,"stem":199,"options":200,"answer":116,"analysis":33},973207,"再充装灭火剂之前，应对未更换的零部件进行清洁处理。（）",[201,202],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":204,"libraryId":5,"type":111,"typeLabel":112,"stem":205,"options":206,"answer":118,"analysis":33},973208,"干粉灭火器出厂满12年报废。（）",[207,208],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":210,"libraryId":5,"type":111,"typeLabel":112,"stem":211,"options":212,"answer":118,"analysis":33},973209,"水基型灭火器钢瓶中的灭火剂清除处理时可直接倒入下水道。（）",[213,214],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":216,"libraryId":5,"type":111,"typeLabel":112,"stem":217,"options":218,"answer":116,"analysis":33},973210,"灭火器的瓶体一旦被火烧过要报废处理。（）",[219,220],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":222,"libraryId":5,"type":111,"typeLabel":112,"stem":223,"options":224,"answer":116,"analysis":33},973211,"水基型灭火器超过出厂期满3年或首次维修以后每满1年要进行维修。（）",[225,226],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":228,"libraryId":5,"type":111,"typeLabel":112,"stem":229,"options":230,"answer":118,"analysis":33},973212,"室内消火栓开启后本体渗漏可能因为箱体有损坏。（）",[231,232],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":234,"libraryId":5,"type":111,"typeLabel":112,"stem":235,"options":236,"answer":116,"analysis":33},973213,"阀瓣组件与阀座之间因变形或污垢、杂物阻挡出现不密封状态，从而导致湿式报警阀组漏水。（）",[237,238],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":240,"libraryId":5,"type":111,"typeLabel":112,"stem":241,"options":242,"answer":116,"analysis":33},973214,"洒水喷头按热敏感元件分易熔元件喷头和玻璃球喷头。（）",[243,244],{"key":20,"text":116,"correct":22},{"key":24,"text":118,"correct":44},{"id":246,"libraryId":5,"type":111,"typeLabel":112,"stem":247,"options":248,"answer":118,"analysis":33},973215,"当定期对灭火器进行巡检、维护时，发现其存在表中的缺陷，及时将灭火器送原生产企业维修部门即可。（）",[249,250],{"key":20,"text":116,"correct":44},{"key":24,"text":118,"correct":22},{"id":252,"libraryId":5,"type":253,"typeLabel":254,"stem":255,"options":256,"answer":27,"analysis":33},973216,1,"单选题","火灾探测器因积尘而导致故障的解决办法是（）。",[257,259,261,263],{"key":20,"text":258,"correct":44},"更换新的探测器",{"key":24,"text":260,"correct":44},"用水清洗",{"key":27,"text":262,"correct":22},"用无水酒精擦拭",{"key":30,"text":264,"correct":44},"用去污剂清洗",{"id":266,"libraryId":5,"type":253,"typeLabel":254,"stem":267,"options":268,"answer":24,"analysis":33},973217,"以下导致室外消火栓无法打开的原因是（）。",[269,271,273,275],{"key":20,"text":270,"correct":44},"管网渗漏严重",{"key":24,"text":272,"correct":22},"阀杆断裂",{"key":27,"text":274,"correct":44},"出水管路泄压阀起跳泄水",{"key":30,"text":276,"correct":44},"系统管路分段控制阀被误关闭",{"id":278,"libraryId":5,"type":253,"typeLabel":254,"stem":279,"options":280,"answer":30,"analysis":33},973218,"以下属于导致水力警铃工作不正常的是（）。",[281,283,285,287],{"key":20,"text":282,"correct":44},"湿式系统延迟器下部孔板溢出水孔堵塞",{"key":24,"text":284,"correct":44},"报警阀渗漏严重通过报警管路流出",{"key":27,"text":286,"correct":44},"桨片被管腔内杂物卡阻",{"key":30,"text":288,"correct":22},"报警管路控制阀被关闭",{"id":290,"libraryId":5,"type":253,"typeLabel":254,"stem":291,"options":292,"answer":20,"analysis":33},973219,"干式自动喷水灭火系统侧管网发生不正常漏气，造成系统侧气压低于其最小供气压力，使干式报警阀误动作。对其解决办法为（）。",[293,295,297,299],{"key":20,"text":294,"correct":22},"排查系统侧管网漏气点并进行维修",{"key":24,"text":296,"correct":44},"排查供气装置故障原因并进行维修处理",{"key":27,"text":298,"correct":44},"安装或更换加速器并进行调试",{"key":30,"text":104,"correct":44},{"id":301,"libraryId":5,"type":253,"typeLabel":254,"stem":302,"options":303,"answer":24,"analysis":33},973220,"玻璃球喷头的工作液为红色其动作温度是（）。",[304,306,308,310],{"key":20,"text":305,"correct":44},"57℃",{"key":24,"text":307,"correct":22},"68℃",{"key":27,"text":309,"correct":44},"79℃",{"key":30,"text":311,"correct":44},"93℃",{"id":313,"libraryId":5,"type":253,"typeLabel":254,"stem":314,"options":315,"answer":30,"analysis":33},973221,"防排烟风机运行噪声过大可能原因是（）。",[316,318,320,322],{"key":20,"text":317,"correct":44},"叶片上附有不均匀的附着物",{"key":24,"text":319,"correct":44},"叶轮变形或不平衡",{"key":27,"text":321,"correct":44},"基础螺栓松动，引起共振。",{"key":30,"text":323,"correct":22},"转速过高",{"id":325,"libraryId":5,"type":253,"typeLabel":254,"stem":326,"options":327,"answer":20,"analysis":33},973222,"对灭火器进行水压试验压力应按灭火器铭牌标志上规定的水压试验压力值进行，保压（）min。",[328,330,332,334],{"key":20,"text":329,"correct":22},"1",{"key":24,"text":331,"correct":44},"2",{"key":27,"text":333,"correct":44},"3",{"key":30,"text":335,"correct":44},"4",{"id":337,"libraryId":5,"type":253,"typeLabel":254,"stem":338,"options":339,"answer":30,"analysis":33},973223,"水基型灭火器出厂满（）年报废。",[340,342,344,345],{"key":20,"text":341,"correct":44},"10",{"key":24,"text":343,"correct":44},"5",{"key":27,"text":335,"correct":44},{"key":30,"text":346,"correct":22},"6",{"id":348,"libraryId":5,"type":253,"typeLabel":254,"stem":349,"options":350,"answer":27,"analysis":33},973224,"以下属于造成现场手动不能正常启闭风阀的原因是（）。",[351,353,355,357],{"key":20,"text":352,"correct":44},"风口开启过多",{"key":24,"text":354,"correct":44},"叶轮与轴的连接松动",{"key":27,"text":356,"correct":22},"叶片转轴锈死",{"key":30,"text":358,"correct":44},"轴承损坏",{"id":360,"libraryId":5,"type":253,"typeLabel":254,"stem":361,"options":362,"answer":24,"analysis":33},973225,"无论灭火器是否被使用过，拆卸瓶头阀门前一定要先（）。",[363,365,367,369],{"key":20,"text":364,"correct":44},"检查钢瓶生产日期",{"key":24,"text":366,"correct":22},"泄压",{"key":27,"text":368,"correct":44},"检查产品铭牌",{"key":30,"text":370,"correct":44},"查看压力表指针是否早绿区",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":32,"analysis":33},973226,"消防水池(箱)液位报警原因有（）。",[375,377,379,380],{"key":20,"text":376,"correct":22},"浮球阀或液位控制阀产品存在质量问题，无法关闭。",{"key":24,"text":378,"correct":22},"液位过低",{"key":27,"text":57,"correct":22},{"key":30,"text":381,"correct":22},"报警液位设定不准确",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":32,"analysis":33},973227,"对于可能造成消防控制室远程不能启停消防水泵的原因，维修方法有（）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"对线路进行检查维修",{"key":24,"text":389,"correct":22},"对多线控制盘进行检査维修",{"key":27,"text":391,"correct":22},"对线路进行检查，对损坏模块进行更换。",{"key":30,"text":393,"correct":22},"将多线控制盘解锁为“手动允许”，将消防泵组电气控制柜设置为“自动”状态",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":47,"analysis":33},973228,"洒水喷头按喷头灵敏度分（）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"快速响应喷头",{"key":24,"text":401,"correct":22},"特殊响应喷头",{"key":27,"text":403,"correct":44},"玻璃球喷头",{"key":30,"text":405,"correct":22},"标准响应喷头",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":418,"analysis":33},973229,"消防应急广播无法应急启动的原因有（）。",[410,412,414,416],{"key":20,"text":411,"correct":44},"扬声器损坏或扬声器发生线路故障",{"key":24,"text":413,"correct":22},"广播控制器音源文件丢失",{"key":27,"text":415,"correct":22},"广播控制器发生通信故障或损坏",{"key":30,"text":417,"correct":22},"功率放大器发生线路故障导致过载或损坏","BCD",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":32,"analysis":33},973230,"造成室外消火栓出水压力不足的原因有（）。",[423,424,426,427],{"key":20,"text":270,"correct":22},{"key":24,"text":425,"correct":22},"临时高压系统消防水泵未启动",{"key":27,"text":274,"correct":22},{"key":30,"text":428,"correct":22},"消防水泵试水管路阀门被误开启",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":418,"analysis":33},973231,"以下属于防火门门扇无法开启的原因是（）。",[433,435,437,438],{"key":20,"text":434,"correct":44},"顺序器损坏",{"key":24,"text":436,"correct":22},"闭门器主体装反",{"key":27,"text":25,"correct":22},{"key":30,"text":439,"correct":22},"连杆上的螺钉挡住门扇",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":450,"analysis":33},973232,"室外消火栓打开时无水的原因有（）。",[444,446,447,449],{"key":20,"text":445,"correct":22},"消火栓检修井闸阀被误关闭",{"key":24,"text":276,"correct":22},{"key":27,"text":448,"correct":22},"供水管道无水",{"key":30,"text":272,"correct":44},"ABC",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":463,"analysis":33},973233,"以下属于推车式灭火器常见的故障是（）。",[455,457,459,461],{"key":20,"text":456,"correct":22},"喷射控制枪阀门开关不灵活或损坏",{"key":24,"text":458,"correct":44},"产品铭牌缺失",{"key":27,"text":460,"correct":22},"喷射控制枪存在明显变形、裂纹",{"key":30,"text":462,"correct":22},"车轮和车架部件有明显损伤，不能推(拉)自如","ACD",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":32,"analysis":33},973234,"手提式灭火器喷射软管可能出现的问题有（）。",[468,470,472,474],{"key":20,"text":469,"correct":22},"变形",{"key":24,"text":471,"correct":22},"龟裂",{"key":27,"text":473,"correct":22},"断裂",{"key":30,"text":475,"correct":22},"接头脱落",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":32,"analysis":33},973235,"对灭火器外观目测判断有（）应报废。",[480,482,484,486],{"key":20,"text":481,"correct":22},"瓶体有严重变形",{"key":24,"text":483,"correct":22},"瓶体外表面、连接部位、底座等有腐蚀的凹坑",{"key":27,"text":485,"correct":22},"瓶体外部涂层脱落面积大于气瓶总面积的1\u002F3",{"key":30,"text":487,"correct":22},"铭牌标志脱落，或虽有铭牌标志，但标志上生产商名称无法识别、灭火剂名称和充装量模糊不清，以及永久性标志内容无法辨认",[489,492,495,498,501,504],{"id":253,"name":490,"category":7,"favorite":491},"领导干部任职前廉政法规知识测试题",92,{"id":493,"name":494,"category":7,"favorite":253},595,"建筑结构与设备",{"id":496,"name":497,"category":7,"favorite":253},715,"招标采购专业知识与法律法规",{"id":499,"name":500,"category":7,"favorite":253},848,"市政方向-通用基础",{"id":502,"name":503,"category":7,"favorite":8},534,"BIM工程师",{"id":505,"name":503,"category":7,"favorite":8},535]