[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-50":3},{"library":4,"page":9,"limit":9,"total":10,"questions":11,"related":387},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,50,2486,[12,33,43,49,55,67,79,85,91,109,120,126,132,138,150,156,168,174,186,198,213,219,234,240,251,263,269,275,290,296,308,323,338,353,365,377],{"id":13,"libraryId":5,"type":14,"typeLabel":15,"stem":16,"options":17,"answer":26,"analysis":32},975405,1,"单选题","火灾自动报警系统一般由火灾探测报警系统、消防联动控制系统、可燃气体探测报警系统和（ ）等全部或部分构成。",[18,22,25,29],{"key":19,"text":20,"correct":21},"A","光电感烟火灾探测器",false,{"key":23,"text":24,"correct":21},"B","消防电话总机",{"key":26,"text":27,"correct":28},"C","电气火灾监控系统",true,{"key":30,"text":31,"correct":21},"D","室内消火栓","",{"id":34,"libraryId":5,"type":35,"typeLabel":36,"stem":37,"options":38,"answer":42,"analysis":32},975406,3,"判断题","末端试水装置的试水接头出水口的流量系数，应等同于同楼层或防火分区的最大流量系数。",[39,41],{"key":19,"text":40,"correct":21},"正确",{"key":23,"text":42,"correct":28},"错误",{"id":44,"libraryId":5,"type":35,"typeLabel":36,"stem":45,"options":46,"answer":40,"analysis":32},975408,"火灾报警控制器应安装牢固，不应倾斜；安装在轻质墙上时，应采取加固措施。",[47,48],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":50,"libraryId":5,"type":35,"typeLabel":36,"stem":51,"options":52,"answer":40,"analysis":32},975409,"施工中应对系统的线路进行检查，对于错线、开路、虚焊、短路、绝缘电阻小于20MΩ等问题，应采取相应的处理措施，以确保系统运行的稳定性和可靠性。",[53,54],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":56,"libraryId":5,"type":14,"typeLabel":15,"stem":57,"options":58,"answer":30,"analysis":32},975410,"在对手动火灾报警按钮功能测试时，按下手动火灾报警按钮的启动零件，（ ）报警确认灯应点亮，并保持至被复位。",[59,61,63,65],{"key":19,"text":60,"correct":21},"绿色",{"key":23,"text":62,"correct":21},"黄色",{"key":26,"text":64,"correct":21},"白色",{"key":30,"text":66,"correct":28},"红色",{"id":68,"libraryId":5,"type":14,"typeLabel":15,"stem":69,"options":70,"answer":30,"analysis":32},975411,"下列选项中，（ ）应具有启动消防栓泵的功能。",[71,73,75,77],{"key":19,"text":72,"correct":21},"火灾显示盘",{"key":23,"text":74,"correct":21},"手动火灾报警按钮",{"key":26,"text":76,"correct":21},"火灾报警控制器",{"key":30,"text":78,"correct":28},"消防联动控制器",{"id":80,"libraryId":5,"type":35,"typeLabel":36,"stem":81,"options":82,"answer":40,"analysis":32},975412,"按设计文件核查火灾自动报警系统的规格、型号、数量、备品备件的数量，以确保系统组件的规格、型号、数量、备品备件数量与设计文件一致。",[83,84],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":86,"libraryId":5,"type":35,"typeLabel":36,"stem":87,"options":88,"answer":42,"analysis":32},975413,"点型火灾探测器距多孔送风顶棚孔口的水平距离不应小于0.2m。",[89,90],{"key":19,"text":40,"correct":21},{"key":23,"text":42,"correct":28},{"id":92,"libraryId":5,"type":93,"typeLabel":94,"stem":95,"options":96,"answer":108,"analysis":32},975414,2,"多选题","消防设备末端配电装置外壳的产品铭牌内容应至少包括（ ）。",[97,99,101,103,105],{"key":19,"text":98,"correct":28},"产品名称",{"key":23,"text":100,"correct":28},"规格型号",{"key":26,"text":102,"correct":28},"额定电压",{"key":30,"text":104,"correct":28},"防护等级",{"key":106,"text":107,"correct":21},"E","箱体尺寸","ABCD",{"id":110,"libraryId":5,"type":93,"typeLabel":94,"stem":111,"options":112,"answer":119,"analysis":32},975415,"下列应设置在消防控制室内或有人值班的房间和场所是（ ）。",[113,114,116,117,118],{"key":19,"text":72,"correct":21},{"key":23,"text":115,"correct":21},"消防水泵接合器",{"key":26,"text":31,"correct":21},{"key":30,"text":76,"correct":28},{"key":106,"text":78,"correct":28},"DE",{"id":121,"libraryId":5,"type":35,"typeLabel":36,"stem":122,"options":123,"answer":42,"analysis":32},975416,"在检查防烟排烟系统过程中，余压值测试时，不必关注门、窗、孔洞等的布置情况。",[124,125],{"key":19,"text":40,"correct":21},{"key":23,"text":42,"correct":28},{"id":127,"libraryId":5,"type":35,"typeLabel":36,"stem":128,"options":129,"answer":42,"analysis":32},975417,"需要火灾自动报警系统联动控制的消防设备，其联动触发信号应采用三个独立的报警触发装置报警信号的“与”逻辑组合。",[130,131],{"key":19,"text":40,"correct":21},{"key":23,"text":42,"correct":28},{"id":133,"libraryId":5,"type":35,"typeLabel":36,"stem":134,"options":135,"answer":40,"analysis":32},975418,"火灾报警控制器的接地应牢固，并有明显的永久性标识。",[136,137],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":139,"libraryId":5,"type":14,"typeLabel":15,"stem":140,"options":141,"answer":30,"analysis":32},975419,"当确认火灾后，由发生火灾的报警区域开始，顺序启动全楼疏散通道的消防应急照明和疏散指示系统，系统全部投入应急状态的启动时间不应大于（ ）。",[142,144,146,148],{"key":19,"text":143,"correct":21},"10s",{"key":23,"text":145,"correct":21},"8s",{"key":26,"text":147,"correct":21},"6s",{"key":30,"text":149,"correct":28},"5s",{"id":151,"libraryId":5,"type":35,"typeLabel":36,"stem":152,"options":153,"answer":42,"analysis":32},975420,"火灾报警控制器应安装牢固，不应倾斜。安装在轻质墙上时，不必采取加固措施。",[154,155],{"key":19,"text":40,"correct":21},{"key":23,"text":42,"correct":28},{"id":157,"libraryId":5,"type":14,"typeLabel":15,"stem":158,"options":159,"answer":30,"analysis":32},975421,"火灾报警控制器在断路故障报警期间，采用发烟装置或温度不低于（ ）的热源，先后向同一回路中两个火灾探测器施放烟气或加热，查看火灾报警控制器的火警信号、报警部位显示及记录。",[160,162,164,166],{"key":19,"text":161,"correct":21},"40℃",{"key":23,"text":163,"correct":21},"45℃",{"key":26,"text":165,"correct":21},"50℃",{"key":30,"text":167,"correct":28},"54℃",{"id":169,"libraryId":5,"type":35,"typeLabel":36,"stem":170,"options":171,"answer":42,"analysis":32},975422,"线型红外光束感烟火灾探测器的发射器和接收器应安装牢固，并可以产生位移。",[172,173],{"key":19,"text":40,"correct":21},{"key":23,"text":42,"correct":28},{"id":175,"libraryId":5,"type":14,"typeLabel":15,"stem":176,"options":177,"answer":30,"analysis":32},975423,"用（ ）测量火灾报警控制器的联动输出信号。在火灾报警控制器的检测过程中，同时查看火灾显示盘的显示。",[178,180,182,184],{"key":19,"text":179,"correct":21},"测电笔",{"key":23,"text":181,"correct":21},"消防设备编码器",{"key":26,"text":183,"correct":21},"发烟装置",{"key":30,"text":185,"correct":28},"万用表",{"id":187,"libraryId":5,"type":14,"typeLabel":15,"stem":188,"options":189,"answer":30,"analysis":32},975424,"下列关于防烟排烟系统常用检测工具的使用方法，说法错误的是（ ）。",[190,192,194,196],{"key":19,"text":191,"correct":21},"手持风速仪风扇或将其固定于脚架上，保持风扇外壳标注箭头方向与风口气流方向一致。",{"key":23,"text":193,"correct":21},"风速仪屏幕显示的读数趋于稳定时，按下锁定键锁定读数。",{"key":26,"text":195,"correct":21},"用胶管连接数字微压计正负接嘴，将正压接嘴用胶管置于机械加压送风部位，负压接嘴置于常压部位。",{"key":30,"text":197,"correct":28},"数字微压计不必手按回零开关，可直接使用。",{"id":199,"libraryId":5,"type":93,"typeLabel":94,"stem":200,"options":201,"answer":212,"analysis":32},975425,"末端试水装置应由（ ）组成。",[202,204,206,208,210],{"key":19,"text":203,"correct":21},"压力开关",{"key":23,"text":205,"correct":21},"信号阀",{"key":26,"text":207,"correct":28},"试水阀",{"key":30,"text":209,"correct":28},"压力表",{"key":106,"text":211,"correct":28},"试水接头","CDE",{"id":214,"libraryId":5,"type":35,"typeLabel":36,"stem":215,"options":216,"answer":40,"analysis":32},975426,"干式报警阀组应安装在不发生冰冻的场所。",[217,218],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":220,"libraryId":5,"type":93,"typeLabel":94,"stem":221,"options":222,"answer":233,"analysis":32},975427,"消防联动控制器应具有发出联动控制信号强制所有电梯停于（ ）的功能。",[223,225,227,229,231],{"key":19,"text":224,"correct":28},"首层",{"key":23,"text":226,"correct":21},"地下一层",{"key":26,"text":228,"correct":28},"电梯转换层",{"key":30,"text":230,"correct":21},"顶层",{"key":106,"text":232,"correct":21},"地上二层","AC",{"id":235,"libraryId":5,"type":35,"typeLabel":36,"stem":236,"options":237,"answer":40,"analysis":32},975428,"在检查火灾探测器时，火灾探测器表面应无影响探测功能的障碍物，如感温原件表面涂覆涂料，点型感烟探测器烟气通道被涂料、胶带纸、防尘罩等堵塞。",[238,239],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":241,"libraryId":5,"type":14,"typeLabel":15,"stem":242,"options":243,"answer":30,"analysis":32},975429,"在测试火灾自动报警系统联动功能时，应将输入输出模块分别标记为非消防电源、（ ）、电动栅杆的等设备。",[244,245,247,249],{"key":19,"text":203,"correct":21},{"key":23,"text":246,"correct":21},"信号蝶阀",{"key":26,"text":248,"correct":21},"水流指示器",{"key":30,"text":250,"correct":28},"消防电梯",{"id":252,"libraryId":5,"type":14,"typeLabel":15,"stem":253,"options":254,"answer":26,"analysis":32},975430,"下列关于测试火灾自动报警系统组件功能的操作内容不包括（ ）。",[255,257,259,261],{"key":19,"text":256,"correct":21},"测试火灾探测器功能",{"key":23,"text":258,"correct":21},"测试火灾警报装置",{"key":26,"text":260,"correct":28},"填写《建筑消防设施巡查记录表》",{"key":30,"text":262,"correct":21},"检测完毕后，应将各火灾自动报警系统组件恢复至原状",{"id":264,"libraryId":5,"type":35,"typeLabel":36,"stem":265,"options":266,"answer":40,"analysis":32},975431,"常见的仪表有表盘指针式和数字式两种。",[267,268],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":270,"libraryId":5,"type":35,"typeLabel":36,"stem":271,"options":272,"answer":42,"analysis":32},975432,"当梁突出顶棚的高度超过0.6m时，被梁隔断的每个梁间区域应至少设置两只探测器。",[273,274],{"key":19,"text":40,"correct":21},{"key":23,"text":42,"correct":28},{"id":276,"libraryId":5,"type":93,"typeLabel":94,"stem":277,"options":278,"answer":289,"analysis":32},975433,"下列关于手动火灾报警按钮的设置和安装要求说法正确的是（ ）。",[279,281,283,285,287],{"key":19,"text":280,"correct":28},"每个防火分区应至少设置一只，应设在明显和便于操作的部位",{"key":23,"text":282,"correct":21},"从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离不应大于40m",{"key":26,"text":284,"correct":28},"手动火灾报警按钮宜设置在疏散通道或出入口处",{"key":30,"text":286,"correct":28},"当采用壁挂方式安装时，其底边距地高度宜为1.3至1.5m，且应有明显标识",{"key":106,"text":288,"correct":28},"手动火灾报警按钮应安装牢固，不应倾斜","ACDE",{"id":291,"libraryId":5,"type":35,"typeLabel":36,"stem":292,"options":293,"answer":40,"analysis":32},975434,"消防水池（水箱）的施工和安装应符合《给水排水构筑物施工及验收规范》（GB50141）、《建筑给水排水及釆暖工程施工质量验收规范》（GB50242）的有关规定。",[294,295],{"key":19,"text":40,"correct":28},{"key":23,"text":42,"correct":21},{"id":297,"libraryId":5,"type":14,"typeLabel":15,"stem":298,"options":299,"answer":19,"analysis":32},975435,"手动火灾报警按钮在每个（ ）应至少设置一只，应设在明显和便于操作的部位。",[300,302,304,306],{"key":19,"text":301,"correct":28},"防火分区",{"key":23,"text":303,"correct":21},"防护区域",{"key":26,"text":305,"correct":21},"探测区域",{"key":30,"text":307,"correct":21},"报警区域",{"id":309,"libraryId":5,"type":93,"typeLabel":94,"stem":310,"options":311,"answer":322,"analysis":32},975436,"下列关于末端试水装置的作用，说法正确的是（ ）。",[312,314,316,318,320],{"key":19,"text":313,"correct":28},"检验自动喷水灭火系统的可靠性",{"key":23,"text":315,"correct":28},"测试水流指示器、报警阀、压力开关、水力警铃的动作是否正常",{"key":26,"text":317,"correct":28},"测试系统最不利点处的工作压力",{"key":30,"text":319,"correct":21},"测试火灾报警控制器的主电与备电切换功能",{"key":106,"text":321,"correct":28},"用于检测干式系统和预作用系统的充水时间","ABCE",{"id":324,"libraryId":5,"type":93,"typeLabel":94,"stem":325,"options":326,"answer":337,"analysis":32},975437,"检查湿式、干式自动喷水灭火系统管网安装情况时，通过（ ）等方式，检查管道支架、吊架、防晃支架的设置情况和安装质量。",[327,329,331,333,335],{"key":19,"text":328,"correct":28},"目测",{"key":23,"text":330,"correct":28},"敲击",{"key":26,"text":332,"correct":21},"功能测试",{"key":30,"text":334,"correct":21},"对照未审核的消防设计文件",{"key":106,"text":336,"correct":28},"尺量","ABE",{"id":339,"libraryId":5,"type":93,"typeLabel":94,"stem":340,"options":341,"answer":352,"analysis":32},975438,"火灾报警控制器的检测内容主要是试验火警报警、（ ）、消音等功能。",[342,344,346,348,350],{"key":19,"text":343,"correct":28},"故障报警",{"key":23,"text":345,"correct":28},"火警优先",{"key":26,"text":347,"correct":21},"巡检",{"key":30,"text":349,"correct":28},"自检",{"key":106,"text":351,"correct":28},"打印机打印","ABDE",{"id":354,"libraryId":5,"type":14,"typeLabel":15,"stem":355,"options":356,"answer":19,"analysis":32},975439,"火灾探测器宜水平安装，当确需倾斜安装时，倾斜角不应大于（ ）。",[357,359,361,363],{"key":19,"text":358,"correct":28},"45°",{"key":23,"text":360,"correct":21},"60°",{"key":26,"text":362,"correct":21},"75°",{"key":30,"text":364,"correct":21},"90°",{"id":366,"libraryId":5,"type":14,"typeLabel":15,"stem":367,"options":368,"answer":19,"analysis":32},975440,"手动火灾报警按钮从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离不应大于（ ）。",[369,371,373,375],{"key":19,"text":370,"correct":28},"30m",{"key":23,"text":372,"correct":21},"40m",{"key":26,"text":374,"correct":21},"45m",{"key":30,"text":376,"correct":21},"35m",{"id":378,"libraryId":5,"type":14,"typeLabel":15,"stem":379,"options":380,"answer":23,"analysis":32},975441,"火灾报警控制器、火灾显示器、（ ）等控制器设备在墙上安装时，其主显示屏高度宜为1.5至1.8m。",[381,382,383,385],{"key":19,"text":74,"correct":21},{"key":23,"text":78,"correct":28},{"key":26,"text":384,"correct":21},"点型火灾探测器",{"key":30,"text":386,"correct":21},"消防电话插孔",[388,391,394,397,400,403],{"id":14,"name":389,"category":7,"favorite":390},"领导干部任职前廉政法规知识测试题",92,{"id":392,"name":393,"category":7,"favorite":14},595,"建筑结构与设备",{"id":395,"name":396,"category":7,"favorite":14},715,"招标采购专业知识与法律法规",{"id":398,"name":399,"category":7,"favorite":14},848,"市政方向-通用基础",{"id":401,"name":402,"category":7,"favorite":8},534,"BIM工程师",{"id":404,"name":402,"category":7,"favorite":8},535]