[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":572},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,5,50,2486,[13,34,48,61,73,85,97,109,121,133,145,156,167,179,192,205,217,229,239,245,251,257,263,269,275,281,287,301,313,325,337,349,361,373,385,397,409,421,432,444,452,464,476,488,501,513,525,536,548,560],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":32,"analysis":33},973134,2,"多选题","属于可燃气体报警控制器的保养操作程序的是（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","使用钥匙打开箱门，将控制器主备电源切断",true,{"key":24,"text":25,"correct":22},"B","用小毛刷将机柜（壳）内设备空隙和线材上的灰尘和杂质清扫出来，然后用吸尘器清理干净",{"key":27,"text":28,"correct":22},"C","检查线路接头处有无氧化或锈蚀痕迹，若有则应采取防潮、防锈措施，如镀锡和涂抹凡士林等",{"key":30,"text":31,"correct":22},"D","发现螺栓及垫片有生锈现象应予更换，确保接头连接紧密","ABCD","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":47,"analysis":33},973135,"湿式、干式自动喷水灭火系统报警阀组的保养方法有（）。",[38,41,43,45],{"key":20,"text":39,"correct":40},"检查系统各个控制阀门，发现铅封损坏或者锁链未固定在规定状态的，及时更换铅封并调整锁链至规定的固定状态",false,{"key":24,"text":42,"correct":40},"发现阀门有漏水、锈蚀等情形的，更换阀门密封垫，修理或者更换阀门，对锈蚀部位进行除锈处理",{"key":27,"text":44,"correct":22},"检查阀瓣上的橡胶密封垫，表面应清洁无损伤，否则应清洗或更换",{"key":30,"text":46,"correct":22},"阀座密封面应平整，无碰伤和压痕，否则应修理或更换","CD",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":60,"analysis":33},973136,"湿式、干式自动喷水灭火系统管道的保养方法有（）。",[52,54,56,58],{"key":20,"text":53,"correct":22},"检查发现管道漆面脱落、管道接头存在渗漏、锈蚀的，应进行刷漆、补漏除锈处理",{"key":24,"text":55,"correct":22},"检查发现支架、吊架脱焊、管卡松动的，应进行补焊和紧固处理",{"key":27,"text":57,"correct":22},"检查管道各过滤器的使用性能，对滤网进行拆洗，并重新安装到位",{"key":30,"text":59,"correct":40},"清洗报警管路上的过滤器","ABC",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":32,"analysis":33},973137,"下列属于消防泵组及电气控制柜的保养项目的是（）。",[65,67,69,71],{"key":20,"text":66,"correct":22},"控制柜工作环境",{"key":24,"text":68,"correct":22},"控制柜外观",{"key":27,"text":70,"correct":22},"控制柜电气部件",{"key":30,"text":72,"correct":22},"泵组",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":32,"analysis":33},973138,"消防增（稳）压设施保养项目有（）。",[77,79,81,83],{"key":20,"text":78,"correct":22},"机房环境检查",{"key":24,"text":80,"correct":22},"消防水箱保养",{"key":27,"text":82,"correct":22},"稳压泵组保养",{"key":30,"text":84,"correct":22},"气压罐及供水附件保养",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":32,"analysis":33},973139,"消防设备末端配电装置保养项目有（）。",[89,91,93,95],{"key":20,"text":90,"correct":22},"指示灯保养",{"key":24,"text":92,"correct":22},"切换开关保养",{"key":27,"text":94,"correct":22},"母线保养",{"key":30,"text":96,"correct":22},"熔断器保养",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":32,"analysis":33},973140,"消防设备末端配电装置保养方法有（）。",[101,103,105,107],{"key":20,"text":102,"correct":22},"清洁消防设备末端配电装置前应停电",{"key":24,"text":104,"correct":22},"检查断路器操作机构是否到位，接线螺栓是否紧固",{"key":27,"text":106,"correct":22},"清除接触器触点表面及四周的污物",{"key":30,"text":108,"correct":22},"检查接触器触点接触是否完好，触点接触不良，必要时可稍微修锉触点表面，如触点严重烧蚀应更换触点",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":120,"analysis":33},973141,"火灾显示盘接线保养的保养方法（）。",[113,115,117,119],{"key":20,"text":114,"correct":22},"发现螺栓、垫片及配件有生锈现象及时予以更换",{"key":24,"text":116,"correct":40},"用螺丝刀紧固，接线端烫锡",{"key":27,"text":118,"correct":22},"检查接线端子有无松动情况，发现松动应用螺丝刀紧固，确保连接紧密",{"key":30,"text":28,"correct":22},"ACD",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":32,"analysis":33},973142,"报警阀组保养要求（）。",[125,127,129,131],{"key":20,"text":126,"correct":22},"外观完好，标识清晰，并注明系统名称和保护区域",{"key":24,"text":128,"correct":22},"阀组组件齐全，表面无裂纹、损伤、锈蚀和渗漏",{"key":27,"text":130,"correct":22},"阀瓣密封垫清洁无损伤，阀座平整完好，报警孔畅通、无沉沙",{"key":30,"text":132,"correct":22},"各阀门启闭状态正确，启闭标识明显，锁具完好，信号阀反馈信号正确",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":32,"analysis":33},973143,"管道保养要求（）。",[137,139,141,143],{"key":20,"text":138,"correct":22},"管道及附件外观应完好、无损伤，管道接头无渗漏、锈蚀",{"key":24,"text":140,"correct":22},"外表漆面或色环正确，无脱落",{"key":27,"text":142,"correct":22},"系统和水流方向标识清晰",{"key":30,"text":144,"correct":22},"过滤器状态完好",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":32,"analysis":33},973144,"消防电话系统保养方法有（）。",[149,151,153,154],{"key":20,"text":150,"correct":22},"用吸尘器、清洁的干软布等清除机壳表面及所有接线端子处的灰尘",{"key":24,"text":152,"correct":22},"对所有按键进行按下、弹起操作",{"key":27,"text":116,"correct":22},{"key":30,"text":155,"correct":22},"测试群呼功能，选择录音回放选项进行播放",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":60,"analysis":33},973145,"下列属于消防应急广播的功能检查的保养方法的有（）。",[160,162,164,166],{"key":20,"text":161,"correct":22},"在手动状态和自动状态下测试应急广播功能",{"key":24,"text":163,"correct":22},"在自动状态下测试消防应急广播与火灾声报警分时交替循环播放功能",{"key":27,"text":165,"correct":22},"启动应急广播，测试声压级，对存在问题的扬声器进行调整或更换",{"key":30,"text":155,"correct":40},{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":32,"analysis":33},973147,"下列属于消防电梯排水泵的保养方法的有（）。",[171,173,175,177],{"key":20,"text":172,"correct":22},"手动盘车，如有卡滞和异响及时进行维修",{"key":24,"text":174,"correct":22},"目测检查润滑油油质，对到期或变质、掺水的进行更换",{"key":27,"text":176,"correct":22},"进行外表清洁、除锈",{"key":30,"text":178,"correct":22},"进行阀门启闭功能测试、启闭状态核查和润滑，损坏的阀门及时更换",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":191,"analysis":33},973148,"主、备电源的自动转换功能的保养方法（）。",[183,185,187,189],{"key":20,"text":184,"correct":22},"灯具采用集中电源供电时，应能手动控制集中电源转入蓄电池电源输出",{"key":24,"text":186,"correct":22},"灯具采用自带蓄电池供电时，应能手动控制应急照明配电箱切断电源输出。",{"key":27,"text":188,"correct":40},"灯具采用自带蓄电池供电时，应能自动控制应急照明配电箱切断电源输出。",{"key":30,"text":190,"correct":40},"灯具采用集中电源供电时，应能自动控制集中电源转入蓄电池电源输出","AB",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":204,"analysis":33},973149,"下列属于防烟排烟系统风机控制柜保养方法的是（）。",[196,198,200,202],{"key":20,"text":197,"correct":40},"清洁外观，清除杂物",{"key":24,"text":199,"correct":22},"清洁外观，及时进行除锈、补漆",{"key":27,"text":201,"correct":22},"用螺丝刀逐个紧固各接线端子",{"key":30,"text":203,"correct":22},"对损坏的电气线路和元器件及时查清原因，并进行维修更换","BCD",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":32,"analysis":33},973150,"下列属于防烟排烟系统风管（道）保养方法的是（）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"清洁外观",{"key":24,"text":212,"correct":22},"修复变形",{"key":27,"text":214,"correct":22},"对损坏件及时进行维修或更换",{"key":30,"text":216,"correct":22},"紧固连接部件螺栓或补加铆接",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":204,"analysis":33},973151,"防（排）烟风机保养操作程序正确的是（）。",[221,223,225,227],{"key":20,"text":222,"correct":40},"断开主电源",{"key":24,"text":224,"correct":22},"检查并加固各部分松动的螺丝及联轴器",{"key":27,"text":226,"correct":22},"检查、更换各接合面间的垫片和密封填料",{"key":30,"text":228,"correct":22},"清洁电动机及风滤器和机壳内部",{"id":230,"libraryId":5,"type":231,"typeLabel":232,"stem":233,"options":234,"answer":238,"analysis":33},973152,3,"判断题","如果发现线型光束感烟火灾探测器的发射、接收窗口及反射器表面被灰尘或者油污污染，可以使用水或者其他化学药剂除污。（）",[235,237],{"key":20,"text":236,"correct":40},"正确",{"key":24,"text":238,"correct":22},"错误",{"id":240,"libraryId":5,"type":231,"typeLabel":232,"stem":241,"options":242,"answer":238,"analysis":33},973153,"具有报报脏功能的探测器在报脏时应该及时清洁保养。没有报脏功能的探测器，应按产品说明书的要求进行清洁保养；产品说明书没有明确要求的，应每半年清洁或标定一次。（）",[243,244],{"key":20,"text":236,"correct":40},{"key":24,"text":238,"correct":22},{"id":246,"libraryId":5,"type":231,"typeLabel":232,"stem":247,"options":248,"answer":236,"analysis":33},973154,"线型光束感烟火灾探测器每半年进行一次报警功能测试。（）",[249,250],{"key":20,"text":236,"correct":22},{"key":24,"text":238,"correct":40},{"id":252,"libraryId":5,"type":231,"typeLabel":232,"stem":253,"options":254,"answer":238,"analysis":33},973155,"应急广播声压级距扬声器正前方3m处，用数字声级计测量应急广播声压级（A权计）不应小于65dB。（）",[255,256],{"key":20,"text":236,"correct":40},{"key":24,"text":238,"correct":22},{"id":258,"libraryId":5,"type":231,"typeLabel":232,"stem":259,"options":260,"answer":238,"analysis":33},973156,"接线检查在消防电话总机不断电状态下进行。（）",[261,262],{"key":20,"text":236,"correct":40},{"key":24,"text":238,"correct":22},{"id":264,"libraryId":5,"type":231,"typeLabel":232,"stem":265,"options":266,"answer":236,"analysis":33},973157,"接线检查在消防应急广播断电状态下进行。（）",[267,268],{"key":20,"text":236,"correct":22},{"key":24,"text":238,"correct":40},{"id":270,"libraryId":5,"type":231,"typeLabel":232,"stem":271,"options":272,"answer":238,"analysis":33},973158,"灯具采用自带蓄电池供电时，应能自动控制应急照明配电箱切断电源输出。（）",[273,274],{"key":20,"text":236,"correct":40},{"key":24,"text":238,"correct":22},{"id":276,"libraryId":5,"type":231,"typeLabel":232,"stem":277,"options":278,"answer":236,"analysis":33},973159,"电工业项目应由具备相应等级职业资格人员实施，作业中应严守操作规程。（）",[279,280],{"key":20,"text":236,"correct":22},{"key":24,"text":238,"correct":40},{"id":282,"libraryId":5,"type":231,"typeLabel":232,"stem":283,"options":284,"answer":236,"analysis":33},973160,"风机长时间运转时，应确保相应区域的送风（排烟）口处于开启状态。（）",[285,286],{"key":20,"text":236,"correct":22},{"key":24,"text":238,"correct":40},{"id":288,"libraryId":5,"type":289,"typeLabel":290,"stem":291,"options":292,"answer":30,"analysis":33},973161,1,"单选题","以下可能导致线型感烟火灾探测器工作灯不亮的原因是（）。",[293,295,297,299],{"key":20,"text":294,"correct":40},"探测器积尘过多，影响探测器灵敏度。",{"key":24,"text":296,"correct":40},"探测器发射端和接收端光路发生偏移，未调试到位。",{"key":27,"text":298,"correct":40},"探测器发射端和接收端之间有障碍物遮挡",{"key":30,"text":300,"correct":22},"探测器自身老化损坏",{"id":302,"libraryId":5,"type":289,"typeLabel":290,"stem":303,"options":304,"answer":27,"analysis":33},973162,"报警按钮检测后需使用专用复位钥匙将报警按钮复位，再进行火灾报警控制器的复位、自检操作；观察（）min，应处于正常监视状态。",[305,307,309,311],{"key":20,"text":306,"correct":40},"5",{"key":24,"text":308,"correct":40},"4",{"key":27,"text":310,"correct":22},"2",{"key":30,"text":312,"correct":40},"3",{"id":314,"libraryId":5,"type":289,"typeLabel":290,"stem":315,"options":316,"answer":24,"analysis":33},973163,"以下属于湿式报警阀组漏水原因的是（）。",[317,319,321,323],{"key":20,"text":318,"correct":40},"压力表损坏或压力表进水管路堵塞",{"key":24,"text":320,"correct":22},"报警管路警铃试验阀处渗漏",{"key":27,"text":322,"correct":40},"阀座环形槽和小孔堵塞",{"key":30,"text":324,"correct":40},"限流装置过滤网堵塞",{"id":326,"libraryId":5,"type":289,"typeLabel":290,"stem":327,"options":328,"answer":20,"analysis":33},973164,"阀座上有异物，致使阀瓣关闭不严从而导致干式报警阀自动滴水阀滴漏不止，可采取（）使其停止滴漏。",[329,331,333,335],{"key":20,"text":330,"correct":22},"清除阀座上的异物",{"key":24,"text":332,"correct":40},"完全关闭注水阀",{"key":27,"text":334,"correct":40},"关严或更换警铃试验阀",{"key":30,"text":336,"correct":40},"更换密封圈",{"id":338,"libraryId":5,"type":289,"typeLabel":290,"stem":339,"options":340,"answer":27,"analysis":33},973165,"以下属于湿式报警阀阀后压力表显示正常，但阀前压力表显示无压力原因的是（）。",[341,343,345,347],{"key":20,"text":342,"correct":40},"湿式报警阀损坏且补偿管路堵塞",{"key":24,"text":344,"correct":40},"报警管路控制阀被关闭",{"key":27,"text":346,"correct":22},"高位消防水箱无水",{"key":30,"text":348,"correct":40},"系统侧管道接口渗漏",{"id":350,"libraryId":5,"type":289,"typeLabel":290,"stem":351,"options":352,"answer":24,"analysis":33},973166,"以下属于系统测试时消防水泵不能自动启动原因的是（）。",[353,355,357,359],{"key":20,"text":354,"correct":40},"桨片被管腔内杂物卡阻",{"key":24,"text":356,"correct":22},"压力开关设定值不正确或损坏",{"key":27,"text":358,"correct":40},"复位弹簧损坏",{"key":30,"text":360,"correct":40},"消防总线联动控制设定在“自动”状态",{"id":362,"libraryId":5,"type":289,"typeLabel":290,"stem":363,"options":364,"answer":27,"analysis":33},973167,"以下属于闭式洒水喷头的是（）。",[365,367,369,371],{"key":20,"text":366,"correct":40},"水幕喷头",{"key":24,"text":368,"correct":40},"细水雾喷头",{"key":27,"text":370,"correct":22},"玻璃球喷头",{"key":30,"text":372,"correct":40},"撞击型细水雾喷头",{"id":374,"libraryId":5,"type":289,"typeLabel":290,"stem":375,"options":376,"answer":27,"analysis":33},973168,"以下属于消防水泵接合器漏水原因的是（）。",[377,379,381,383],{"key":20,"text":378,"correct":40},"止回阀粘连，开启度不够",{"key":24,"text":380,"correct":40},"设备或管道内有杂物",{"key":27,"text":382,"correct":22},"止回阀损坏",{"key":30,"text":384,"correct":40},"控制阀被误关闭",{"id":386,"libraryId":5,"type":289,"typeLabel":290,"stem":387,"options":388,"answer":27,"analysis":33},973169,"以下属于特殊类型洒水喷头的是（）。",[389,391,393,395],{"key":20,"text":390,"correct":40},"通用型喷头",{"key":24,"text":392,"correct":40},"下垂型喷头",{"key":27,"text":394,"correct":22},"带涂层喷头",{"key":30,"text":396,"correct":40},"直立型喷头",{"id":398,"libraryId":5,"type":289,"typeLabel":290,"stem":399,"options":400,"answer":24,"analysis":33},973170,"因防火门门扇与地面局部产生摩擦而导致防火门启闭过程不灵活，有卡滞。可通过（）进行维修。",[401,403,405,407],{"key":20,"text":402,"correct":40},"润滑或更换转(传)动部件",{"key":24,"text":404,"correct":22},"检查门扇下框和地面，清除异物，调整门扇与地面间隙。",{"key":27,"text":406,"correct":40},"重新调节闭门器",{"key":30,"text":408,"correct":40},"维修、更换顺序器",{"id":410,"libraryId":5,"type":289,"typeLabel":290,"stem":411,"options":412,"answer":30,"analysis":33},973171,"因电动闭门器滑槽内锁舌过紧或位置不当致防火门开启角度过大使其常开式防火门无法正常关闭，可通过（）进行维修。",[413,415,417,419],{"key":20,"text":414,"correct":40},"更换闭门器",{"key":24,"text":416,"correct":40},"更换模块，编写联动公式",{"key":27,"text":418,"correct":40},"更换监控模",{"key":30,"text":420,"correct":22},"润滑锁舌或重新调试锁舌位置",{"id":422,"libraryId":5,"type":289,"typeLabel":290,"stem":423,"options":424,"answer":27,"analysis":33},973172,"干粉灭火器出厂满（）年报废。",[425,427,428,430],{"key":20,"text":426,"correct":40},"6",{"key":24,"text":306,"correct":40},{"key":27,"text":429,"correct":22},"10",{"key":30,"text":431,"correct":40},"8",{"id":433,"libraryId":5,"type":289,"typeLabel":290,"stem":434,"options":435,"answer":20,"analysis":33},973173,"灭火器瓶体外部涂层脱落面积大于气瓶总面积的（）报废。",[436,438,440,442],{"key":20,"text":437,"correct":22},"1\u002F3",{"key":24,"text":439,"correct":40},"2\u002F3",{"key":27,"text":441,"correct":40},"1\u002F4",{"key":30,"text":443,"correct":40},"3\u002F4",{"id":445,"libraryId":5,"type":289,"typeLabel":290,"stem":446,"options":447,"answer":30,"analysis":33},973174,"在对灭火器进行水压时用到的水压试验机的额定工作压力不小于（）MPa",[448,449,450,451],{"key":20,"text":426,"correct":40},{"key":24,"text":306,"correct":40},{"key":27,"text":431,"correct":40},{"key":30,"text":312,"correct":22},{"id":453,"libraryId":5,"type":289,"typeLabel":290,"stem":454,"options":455,"answer":24,"analysis":33},973175,"防排烟风机控制柜处于“手动”状态而导致风机不能自动启动，可采取（）方式解决。",[456,458,460,462],{"key":20,"text":457,"correct":40},"重新编写联动公式",{"key":24,"text":459,"correct":22},"将风机控制柜设置为“自动”状态",{"key":27,"text":461,"correct":40},"清洁叶片",{"key":30,"text":463,"correct":40},"紧固地脚螺栓",{"id":465,"libraryId":5,"type":289,"typeLabel":290,"stem":466,"options":467,"answer":20,"analysis":33},973176,"以下属于造成风机运行振动剧烈的原因是（）。",[468,470,472,474],{"key":20,"text":469,"correct":22},"叶片上附有不均匀的附着物",{"key":24,"text":471,"correct":40},"润滑油脂不够",{"key":27,"text":473,"correct":40},"管网阻力过大",{"key":30,"text":475,"correct":40},"风机内部、叶轮积灰",{"id":477,"libraryId":5,"type":289,"typeLabel":290,"stem":478,"options":479,"answer":27,"analysis":33},973177,"以下不属于推车式灭火器常见的故障（缺陷）的是（）。",[480,482,484,486],{"key":20,"text":481,"correct":40},"喷射控制枪阀门开关不灵活或损坏",{"key":24,"text":483,"correct":40},"喷射控制枪存在明显变形、裂纹",{"key":27,"text":485,"correct":22},"喷嘴存在明显变形、破裂或连接松动",{"key":30,"text":487,"correct":40},"车轮和车架部件有明显损伤，不能推(拉)自如",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":500,"analysis":33},973178,"稳压泵启动频繁的原因有（）。",[492,494,496,498],{"key":20,"text":493,"correct":22},"管网有泄漏，不能正常保压。",{"key":24,"text":495,"correct":40},"稳压泵出口压力低",{"key":27,"text":497,"correct":22},"稳压泵启停压力设定不正确或电接点压力表(压力开关)损坏",{"key":30,"text":499,"correct":40},"管道内残存空气","AC",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":32,"analysis":33},973179,"以下属于干式系统空压机启动频繁原因的是（）。",[505,507,509,511],{"key":20,"text":506,"correct":22},"干式系统空压机启停压力设定不正确",{"key":24,"text":508,"correct":22},"充气管路连接处松动",{"key":27,"text":510,"correct":22},"报警阀气室相关管路处有渗漏点",{"key":30,"text":512,"correct":22},"系统侧管网有渗漏点",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":60,"analysis":33},973180,"消防控制室无法联动控制防火卷帘的原因有（）。",[517,519,521,523],{"key":20,"text":518,"correct":22},"控制器发生故障",{"key":24,"text":520,"correct":22},"联动控制线路发生故障",{"key":27,"text":522,"correct":22},"控制模块发生故障",{"key":30,"text":524,"correct":40},"异物卡住",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":60,"analysis":33},973181,"对于可能造成防火门关闭后挡烟性能差的原因，维修方法有（）。",[529,531,533,535],{"key":20,"text":530,"correct":22},"用不燃材料填充缝隙和孔洞，并达到耐火极限要求。",{"key":24,"text":532,"correct":22},"重新安装防火门密封条",{"key":27,"text":534,"correct":22},"更换符合要求的密封条",{"key":30,"text":414,"correct":40},{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":32,"analysis":33},973183,"以下属于手提式灭火器常见的故障是（）。",[540,542,544,546],{"key":20,"text":541,"correct":22},"灭火器瓶体存在明显机械损伤和锈蚀",{"key":24,"text":543,"correct":22},"阀门开启机构存在损伤",{"key":27,"text":545,"correct":22},"喷射软管组件存在龟裂、脱落或连接松动",{"key":30,"text":547,"correct":22},"保险装置和封记存在损坏或遗失",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":500,"analysis":33},973184,"（）情况下零部件需要更换。",[552,554,556,558],{"key":20,"text":553,"correct":22},"零部件存在缺陷",{"key":24,"text":555,"correct":40},"零部件外观有油渍",{"key":27,"text":557,"correct":22},"一些特定的零部件每次维修",{"key":30,"text":559,"correct":40},"零部件表面有粉尘",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":32,"analysis":33},973185,"手提式灭火器虹吸管可能出现的问题有（）。",[564,566,568,570],{"key":20,"text":565,"correct":22},"有明显弯折",{"key":24,"text":567,"correct":22},"堵塞",{"key":27,"text":569,"correct":22},"损伤",{"key":30,"text":571,"correct":22},"裂纹",[573,576,579,582,585,588],{"id":289,"name":574,"category":7,"favorite":575},"领导干部任职前廉政法规知识测试题",92,{"id":577,"name":578,"category":7,"favorite":289},595,"建筑结构与设备",{"id":580,"name":581,"category":7,"favorite":289},715,"招标采购专业知识与法律法规",{"id":583,"name":584,"category":7,"favorite":289},848,"市政方向-通用基础",{"id":586,"name":587,"category":7,"favorite":8},534,"BIM工程师",{"id":589,"name":587,"category":7,"favorite":8},535]