[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-49":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":550},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,49,50,2486,[13,34,46,58,76,88,100,112,124,139,153,165,177,189,201,211,217,223,235,241,256,268,280,292,304,316,328,340,346,352,358,364,370,384,390,405,417,427,433,445,457,468,474,484,490,502,508,523,529,535],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},975354,1,"单选题","手动火灾报警按钮当采用壁挂方式安装时，其底边距地高度宜为（ ），且应有明显标识。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","1至1.5m",false,{"key":24,"text":25,"correct":22},"B","1.2至1.8m",{"key":27,"text":28,"correct":29},"C","1.3至1.5m",true,{"key":31,"text":32,"correct":22},"D","1.1至1.8m","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},975355,"当火灾警报器采用壁挂方式安装时，底边距地面高度应大于（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1.5m",{"key":24,"text":41,"correct":22},"1.8m",{"key":27,"text":43,"correct":22},"2m",{"key":31,"text":45,"correct":29},"2.2m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},975356,"下列关于高位消防水箱最低有效水位应满足水灭火设施最不利点处的静水压力说法错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"一类高层公共建筑不应低于0.10MPa,但当建筑高度超过100m时，不应低于0.15MPa。",{"key":24,"text":53,"correct":22},"高层住宅、二类高层公共建筑、多层公共建筑不应低于0.07MPa,多层住宅不宜低于0.07MPa。",{"key":27,"text":55,"correct":22},"工业建筑不应低于0.10MPa,当建筑体积小于20000m3时，不宜低于0.07MPa。",{"key":31,"text":57,"correct":29},"自动喷水灭火系统等自动水灭火系统应根据喷头灭火需求压力确定，但最小不应小于0.15MPa。",{"id":59,"libraryId":5,"type":60,"typeLabel":61,"stem":62,"options":63,"answer":75,"analysis":33},975357,2,"多选题","下列关于检查消火栓系统的安装质量，描述正确的是（ ）。",[64,66,68,70,72],{"key":20,"text":65,"correct":29},"检查室外消火栓系统管网。设置形式、阀门设置和管道材质应符合设计要求。",{"key":24,"text":67,"correct":29},"检查阀门井、地下消火栓井。消火栓前端控制阀应处于开启状态，法兰等连接处无渗漏，井内无积水。",{"key":27,"text":69,"correct":29},"检查室外消火栓。设置位置和防护措施应符合要求，外观完好，安装牢固，出水口高度便于吸水管连接操作。",{"key":31,"text":71,"correct":29},"打开室外消火栓进行放水试验。阔门启闭灵活，水压正常，水质清澈，无锈水和大量砂砾、杂质。",{"key":73,"text":74,"correct":22},"E","检查室内消火栓系统管网。防腐、防冻措施应符合设计要求，管道标识清晰，连接处应无渗漏，管道阀门应正常关闭。","ABCD",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":31,"analysis":33},975358,"排烟风机入口处的总管上设置的（ ）排烟防火阀在关闭后应直接联动控制风机停止。",[80,82,84,86],{"key":20,"text":81,"correct":22},"70℃",{"key":24,"text":83,"correct":22},"93℃",{"key":27,"text":85,"correct":22},"150℃",{"key":31,"text":87,"correct":29},"280℃",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":24,"analysis":33},975359,"火灾自动报警系统接地装置的接地电阻值应符合规定，采用共用接地装置时，接地电阻值不应大于（ ）Ω。",[92,94,96,98],{"key":20,"text":93,"correct":22},"4",{"key":24,"text":95,"correct":29},"1",{"key":27,"text":97,"correct":22},"2",{"key":31,"text":99,"correct":22},"3",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":20,"analysis":33},975360,"火灾自动报警系统一般由（ ）、消防联动控制系统、可燃气体探测报警系统和电气火灾监控系统等全部或部分构成。",[104,106,108,110],{"key":20,"text":105,"correct":29},"火灾探测报警系统",{"key":24,"text":107,"correct":22},"手动火灾报警按钮",{"key":27,"text":109,"correct":22},"消防应急广播",{"key":31,"text":111,"correct":22},"防烟排烟设施",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":31,"analysis":33},975361,"下列关于消防应急照明灯具说法错误的是（ ）。",[116,118,120,122],{"key":20,"text":117,"correct":22},"照明灯具宜安装在顶棚上。",{"key":24,"text":119,"correct":22},"在顶棚、疏散走道或通道的上方安装时，可采用嵌顶、吸顶和吊装式安装。",{"key":27,"text":121,"correct":22},"当条件限制时，照明灯具可安装在走道侧面墙上，其安装高度不应在距地面1～2m;在距地面1m以下侧面墙上安装时，应保证光线照射在灯具的水平线以下。",{"key":31,"text":123,"correct":29},"照明灯具可以安装在地面上。",{"id":125,"libraryId":5,"type":60,"typeLabel":61,"stem":126,"options":127,"answer":138,"analysis":33},975362,"下列步骤中符合消防电梯测试要求的是（ ）。",[128,130,132,134,136],{"key":20,"text":129,"correct":29},"检查消防电梯、电梯井、电梯机房和安全设施的设置情况。",{"key":24,"text":131,"correct":29},"观察电梯迫降和开门情况，核查消防控制室反馈信息。",{"key":27,"text":133,"correct":29},"使用消防电梯轿厢内专用消防对讲电话与消防控制中心进行不少于两次通话试验，通话应语音清晰。",{"key":31,"text":135,"correct":22},"自动启闭前室防火门，查看其启闭性能和关闭效果，从消防控制室核查相关信号反馈情况。",{"key":73,"text":137,"correct":22},"只需测试消防电梯供配电自动切换功能，在正常用电源工作状态下测试消防电梯运行情况。","ABC",{"id":140,"libraryId":5,"type":60,"typeLabel":61,"stem":141,"options":142,"answer":75,"analysis":33},975363,"下列内容符合安全出口标志灯安装要求的有（ ）。",[143,145,147,149,151],{"key":20,"text":144,"correct":29},"安全出口标志灯应安装在安全出口或疏散门内侧上方居中的位置。",{"key":24,"text":146,"correct":29},"室内高度不大于3.5m的场所，标志灯底边离门框距离不应大于200mm。",{"key":27,"text":148,"correct":29},"受安装条件限制标志灯无法安装在门框上侧时，可安装在门的两侧，但门完全开启时标志灯不能被遮挡。",{"key":31,"text":150,"correct":29},"采用吸顶或吊装式安装时，标志灯距安全出口或疏散门所在墙面的距离不宜大于50mm。",{"key":73,"text":152,"correct":22},"室内高度大于3.5m的场所，特大型、大型、中型标志灯底边距地面高度不宜小于3m，且不宜大于8m。",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":31,"analysis":33},975364,"下列关于湿式、干式自动喷水灭火系统管网的设置和安装要求说法错误的是（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"管道材质、管径、接头、管道连接方式以及采取的防腐、防冻等措施，符合消防技术标准和消防设计文件要求",{"key":24,"text":160,"correct":22},"报警阀后的管道上不应安装其他用途的支管、水龙头",{"key":27,"text":162,"correct":22},"如不同系统合用消防水泵时，应在报警阀前分开设置",{"key":31,"text":164,"correct":29},"如不同系统合用消防水泵时，应在报警阀后分开设置",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":20,"analysis":33},975365,"水力警铃与报警阀连接的管道，其管径应为20mm，总长不宜大于（ ）m。",[169,171,173,175],{"key":20,"text":170,"correct":29},"20",{"key":24,"text":172,"correct":22},"25",{"key":27,"text":174,"correct":22},"30",{"key":31,"text":176,"correct":22},"35",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},975366,"消防联动控制器应能按设定的（ ）向各相关受控设备发出联动控制信号，并接收相关设备的联动反馈信号。",[181,183,185,187],{"key":20,"text":182,"correct":22},"反馈信息",{"key":24,"text":184,"correct":22},"设备地址注释信息",{"key":27,"text":186,"correct":22},"调试信息",{"key":31,"text":188,"correct":29},"控制逻辑",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":20,"analysis":33},975367,"下列关于消防电话线路各组件安装质量的检测方法，说法错误的是（ ）。",[193,195,197,199],{"key":20,"text":194,"correct":29},"检查消防电话时，消防电话线路可与外线电话链接，可以用在其他工作中使用。",{"key":24,"text":196,"correct":22},"在消防控制室总机与所有消防电话分机、电话插孔之间互相呼叫并通话，总机应能显示每部分机或电话插孔的位置，呼叫铃声和通话语音应清晰。",{"key":27,"text":198,"correct":22},"消防控制室的外线电话与另外一部外线电话模拟报警电话通话，语音应清晰。",{"key":31,"text":200,"correct":22},"检查消防电话系统群呼、录音等功能，各项功能均应符合要求。",{"id":202,"libraryId":5,"type":203,"typeLabel":204,"stem":205,"options":206,"answer":208,"analysis":33},975368,3,"判断题","设置报警阀组的部位应设有排水设施，排水能力应满足报警阀调试、验收和利用试水阀门泄空系统管道的要求。",[207,209],{"key":20,"text":208,"correct":29},"正确",{"key":24,"text":210,"correct":22},"错误",{"id":212,"libraryId":5,"type":203,"typeLabel":204,"stem":213,"options":214,"answer":210,"analysis":33},975369,"在防火卷帘测试的操作过程中，卷帘下严禁站人、置物但可以有人员通过。",[215,216],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":218,"libraryId":5,"type":203,"typeLabel":204,"stem":219,"options":220,"answer":210,"analysis":33},975370,"在对消防应急广播系统测试时，以手动方式在消防控制室对所有广播分区进行选区广播，对所有共用扬声器进行强行切换，应急广播应适当输出。",[221,222],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":20,"analysis":33},975371,"下列关于室外管网的布置要求说法错误的是（ ）。",[227,229,231,233],{"key":20,"text":228,"correct":29},"室外消防给水采用两路消防供水时应釆用环状管网，当采用一路消防供水时可釆用枝状管网。向环状管网输水的进水管不应少于三条，当其中一条发生故障时，其余的进水管应能满足消防用水总量的供给要求。",{"key":24,"text":230,"correct":22},"环状管道应用阀门分成若干独立段，每段内室外消火栓的数量不宜超过5个。",{"key":27,"text":232,"correct":22},"室外消防给水管道的直径应根据流量、流速和压力要求经计算确定，但不应小于DN100。",{"key":31,"text":234,"correct":22},"当室外消防给水引入管设有倒流防止器，且发生火灾时因其水头损失导致室外消火栓不能满足压力和流量要求时，应在该倒流防止器前设置一个室外消火栓。",{"id":236,"libraryId":5,"type":203,"typeLabel":204,"stem":237,"options":238,"answer":210,"analysis":33},975372,"手动火灾报警按钮的检测内容主要是故障报警功能。",[239,240],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":242,"libraryId":5,"type":60,"typeLabel":61,"stem":243,"options":244,"answer":255,"analysis":33},975373,"检查火灾报警控制器时，查看火灾报警控制器声、光、显示器件（发光二极管、数码管、液晶屏等）、指示灯功能应正常，系统显示时钟与北京时间应无误差，打印机处于开启状态。观察火警、监管、故障、屏蔽指示灯应处于熄灭状态，控制器应处于（ ）等。",[245,247,249,251,253],{"key":20,"text":246,"correct":29},"无火灾火警状态",{"key":24,"text":248,"correct":29},"无监管报警状态",{"key":27,"text":250,"correct":29},"无故障报警状态",{"key":31,"text":252,"correct":22},"无打印机工作状态",{"key":73,"text":254,"correct":29},"控制器未屏蔽有关火灾探测器","ABCE",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":31,"analysis":33},975374,"下列关于消防应急广播的联动控制要求，说法错误的是（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"集中报警系统和控制中心报警系统应设置消防应急广播。",{"key":24,"text":263,"correct":22},"消防应急广播系统的联动控制信号由消防联动控制器发出，当确认火灾后，应同时向全楼进行广播。",{"key":27,"text":265,"correct":22},"在消防控制室应能显示消防应急广播的广播分区的工作状态。",{"key":31,"text":267,"correct":29},"在消防控制室应能手动或按预设控制逻辑联动控制选择广播分区，启动或停止消防应急广播系统，但不能监听消防应急广播。在通过传声器进行应急广播时，应自动对广播内容进行录音。",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":27,"analysis":33},975375,"在环境噪声大于60dB的场所，火灾警报器的声压级应高于背景噪声（ ）。",[272,274,276,278],{"key":20,"text":273,"correct":22},"5dB",{"key":24,"text":275,"correct":22},"10dB",{"key":27,"text":277,"correct":29},"15dB",{"key":31,"text":279,"correct":22},"12dB",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":31,"analysis":33},975376,"（ ）火灾探测器在保护电缆、堆垛等类似保护对象时，应采用接触式布置。",[284,286,288,290],{"key":20,"text":285,"correct":22},"点型感烟",{"key":24,"text":287,"correct":22},"线型感烟",{"key":27,"text":289,"correct":22},"点型感温",{"key":31,"text":291,"correct":29},"线型感温",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":24,"analysis":33},975377,"干式自动喷水灭火系统测试时，还应测试配水管道充水时间应不大于（ ）min。",[296,298,300,302],{"key":20,"text":297,"correct":22},"5min",{"key":24,"text":299,"correct":29},"1min",{"key":27,"text":301,"correct":22},"2min",{"key":31,"text":303,"correct":22},"3min",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":20,"analysis":33},975378,"点型火灾探测器在宽度小于3m的内走道顶棚上宜居中布置，（ ）的安装间距不应超过15m。",[308,310,312,314],{"key":20,"text":309,"correct":29},"感烟火灾探测器",{"key":24,"text":311,"correct":22},"感温火灾探测器",{"key":27,"text":313,"correct":22},"输入模块",{"key":31,"text":315,"correct":22},"输出模块",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":31,"analysis":33},975379,"湿式系统和干式系统洒水喷头的公称动作温度宜高于环境最高温度（ ）。",[320,322,324,326],{"key":20,"text":321,"correct":22},"15℃",{"key":24,"text":323,"correct":22},"20℃",{"key":27,"text":325,"correct":22},"25℃",{"key":31,"text":327,"correct":29},"30℃",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":24,"analysis":33},975380,"报警阀组报警功能（以湿式报警阀警铃试验阀测试为例）的测试内容如下：①检查确认系统各管路阀门处于正常启闭状态②将消防泵组电气控制柜置于“手动”运行状态③打开警铃试验阀，同时按下秒表开始计时，待警铃响起时，停止秒表，通过秒表显示核查延迟时间，水力警铃应在5至90s内发出报警铃声④使用声级计测量，距水力警铃3m远处警铃声压级不应小于70dB⑤关闭警铃试验阀，观察水力警铃停动、余水排出后，恢复消防泵组电气控制柜为“自动”运行状态⑥设有消防控制室的还应核查信号反馈情况，测试完毕后进行复位操作⑦记录检查测试情况以下关于测试报警阀组报警功能的操作程序正确的是（ ）。",[332,334,336,338],{"key":20,"text":333,"correct":22},"③⑤④⑥⑦①②",{"key":24,"text":335,"correct":29},"①②③④⑤⑥⑦",{"key":27,"text":337,"correct":22},"①②④③⑤⑥⑦",{"key":31,"text":339,"correct":22},"③①④⑤⑥⑦②",{"id":341,"libraryId":5,"type":203,"typeLabel":204,"stem":342,"options":343,"answer":208,"analysis":33},975381,"火灾报警控制器检测完成后，系统复位，火灾报警控制器应能恢复到正常监视状态。",[344,345],{"key":20,"text":208,"correct":29},{"key":24,"text":210,"correct":22},{"id":347,"libraryId":5,"type":203,"typeLabel":204,"stem":348,"options":349,"answer":208,"analysis":33},975382,"在检查手动火灾报警按钮时，带有电话插孔的手动火灾报警按钮，其保护措施应完好、插孔内无影响通话的杂物。手动火灾报警按钮周围不存在影响辨识和操作的障碍物。",[350,351],{"key":20,"text":208,"correct":29},{"key":24,"text":210,"correct":22},{"id":353,"libraryId":5,"type":203,"typeLabel":204,"stem":354,"options":355,"answer":210,"analysis":33},975383,"在顶棚下方的线型差温火灾探测器至顶棚距离宜为0.1m，相邻探测器之间水平距离不宜大于5m，探测器至墙壁距离宜为1至2m。",[356,357],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":359,"libraryId":5,"type":203,"typeLabel":204,"stem":360,"options":361,"answer":210,"analysis":33},975384,"在自动喷水灭火系统中，仓库内顶板下洒水喷头与货架内置洒水喷头应整体设置水流指示器。",[362,363],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":365,"libraryId":5,"type":203,"typeLabel":204,"stem":366,"options":367,"answer":210,"analysis":33},975385,"火灾报警控制器、火灾显示器、消防联动控制器等控制器设备在墙上安装时，其主显示屏高度宜为1至6m。",[368,369],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":371,"libraryId":5,"type":60,"typeLabel":61,"stem":372,"options":373,"answer":75,"analysis":33},975386,"下列关于测试室内消火栓系统联动功能操作程序内容正确的是（ ）。",[374,376,378,380,382],{"key":20,"text":375,"correct":29},"检查确认消防泵组电气控制柜处于手动运行模式，消防联动控制处于自动允许状态。",{"key":24,"text":377,"correct":29},"按下任一消火栓按钮，观察火灾自动报警系统相关指（显）示信息。",{"key":27,"text":379,"correct":29},"触发该消火栓按钮所在报警区域内任一只火灾探测器或手动火灾报警按钮，观察火灾自动报警及联动控制系统相关指（显）示信息，核查消防水泵启动信号发出情况。",{"key":31,"text":381,"correct":29},"复位消火栓按钮、手动火灾报警按钮，复位火灾自动报警系统。",{"key":73,"text":383,"correct":22},"将消防泵组电气控制柜保持在手动运行模式。",{"id":385,"libraryId":5,"type":203,"typeLabel":204,"stem":386,"options":387,"answer":208,"analysis":33},975387,"当主电源损坏或发生故障时，备用电源通过装置内的双电源转换开关自动投入使用，当备用电源损坏或发生故障时，则通过双电源转换开关切到主电源的供电上，它可以确保消防负荷连续、可靠运行。",[388,389],{"key":20,"text":208,"correct":29},{"key":24,"text":210,"correct":22},{"id":391,"libraryId":5,"type":60,"typeLabel":61,"stem":392,"options":393,"answer":404,"analysis":33},975388,"火灾自动报警系统接地装置的主要作用是利用接地体把（ ）快速地泄放进大地中，以达到保护人身安全和设备安全的目的。",[394,396,398,400,402],{"key":20,"text":395,"correct":22},"报警电流",{"key":24,"text":397,"correct":22},"动作电流",{"key":27,"text":399,"correct":29},"故障电流",{"key":31,"text":401,"correct":29},"雷电流",{"key":73,"text":403,"correct":22},"联动反馈电流","CD",{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":31,"analysis":33},975389,"未集中设置的模块附近应有尺寸不小于（ ）的标识。",[409,411,413,415],{"key":20,"text":410,"correct":22},"50mm×50mm",{"key":24,"text":412,"correct":22},"75mm×75mm",{"key":27,"text":414,"correct":22},"80mm×80mm",{"key":31,"text":416,"correct":29},"100mm×100mm",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":31,"analysis":33},975390,"消防联动控制器控制疏散通道上设置的防火卷帘下降至距楼板面（ ）处，非疏散通道上设置的防火卷帘下降到楼板面。",[421,423,424,426],{"key":20,"text":422,"correct":22},"1.4m",{"key":24,"text":39,"correct":22},{"key":27,"text":425,"correct":22},"1.6m",{"key":31,"text":41,"correct":29},{"id":428,"libraryId":5,"type":203,"typeLabel":204,"stem":429,"options":430,"answer":208,"analysis":33},975391,"消火栓系统进行测试时，特别是在测量栓口静压时，开启阀门应缓慢，避免压力冲击造成检测装置损坏；放水时不应压折水带。",[431,432],{"key":20,"text":208,"correct":29},{"key":24,"text":210,"correct":22},{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":27,"analysis":33},975392,"消防应急广播系统的联动控制信号应由消防联动控制器发出，当确认火灾后，应（ ）向全楼进行广播。",[437,439,441,443],{"key":20,"text":438,"correct":22},"逐一",{"key":24,"text":440,"correct":22},"按逻辑程序",{"key":27,"text":442,"correct":29},"同时",{"key":31,"text":444,"correct":22},"间歇性",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":31,"analysis":33},975393,"点型火灾探测器距墙壁、梁边及遮挡物不应小于（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":22},"0.2m",{"key":24,"text":452,"correct":22},"0.3m",{"key":27,"text":454,"correct":22},"0.4m",{"key":31,"text":456,"correct":29},"0.5m",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},975394,"火灾报警控制器和消防联动控制器安装在墙上时，其主显示屏高度宜为1.5至1.8m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于（ ）m。",[461,463,465,466],{"key":20,"text":462,"correct":22},"0.8",{"key":24,"text":464,"correct":29},"1.2",{"key":27,"text":95,"correct":22},{"key":31,"text":467,"correct":22},"1.1",{"id":469,"libraryId":5,"type":203,"typeLabel":204,"stem":470,"options":471,"answer":210,"analysis":33},975395,"在使用手摇式接地电阻测试仪测量火灾自动报警系统接地电阻时，当检流计指针缓慢移到“0”平衡点时，才能加快摇表手柄转速，可以在检流计指针仍有较大偏转时加快手柄的转速。",[472,473],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":31,"analysis":33},975396,"湿式、干式自动喷水灭火系统中，管道穿过建筑物的变形缝时，应采取抗变形措施。穿过墙体或楼板时应加设套管，套管长度不得小于墙体厚度，穿过卫生间或厨房楼板的套管，其顶部应高出装饰地面（ ）mm，且套管底部应与楼板底面相平。",[478,479,480,482],{"key":20,"text":170,"correct":22},{"key":24,"text":174,"correct":22},{"key":27,"text":481,"correct":22},"40",{"key":31,"text":483,"correct":29},"50",{"id":485,"libraryId":5,"type":203,"typeLabel":204,"stem":486,"options":487,"answer":208,"analysis":33},975397,"联动控制不应影响连锁控制的功能。",[488,489],{"key":20,"text":208,"correct":29},{"key":24,"text":210,"correct":22},{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":27,"analysis":33},975398,"湿式系统和干式系统应采用（ ）控制稳压泵，并应能调节启停压力。",[494,496,498,500],{"key":20,"text":495,"correct":22},"水流指示器",{"key":24,"text":497,"correct":22},"信号阀",{"key":27,"text":499,"correct":29},"压力开关",{"key":31,"text":501,"correct":22},"快速排气阀",{"id":503,"libraryId":5,"type":203,"typeLabel":204,"stem":504,"options":505,"answer":208,"analysis":33},975399,"在对点型感烟火灾探测器功能测试完成后，应消除探测器内及周围烟雾，复位火灾报警控制器，通过报警确认灯显示探测器其他工作状态时，被显示状态应与火灾报警状态有明显区别。",[506,507],{"key":20,"text":208,"correct":29},{"key":24,"text":210,"correct":22},{"id":509,"libraryId":5,"type":60,"typeLabel":61,"stem":510,"options":511,"answer":522,"analysis":33},975400,"火灾警报装置进行功能测试时，触发同一报警区域内（ ），启动需测试的火灾报警装置。",[512,514,516,518,520],{"key":20,"text":513,"correct":29},"两只独立的火灾探测器",{"key":24,"text":515,"correct":22},"两只非独立的火灾探测器",{"key":27,"text":517,"correct":29},"一只火灾探测器与一只手动火灾报警按钮",{"key":31,"text":519,"correct":22},"两只手动火灾报警按钮",{"key":73,"text":521,"correct":22},"一只火灾探测器与一只输入模块","AC",{"id":524,"libraryId":5,"type":203,"typeLabel":204,"stem":525,"options":526,"answer":210,"analysis":33},975401,"高层住宅、二类高层公共建筑、多层公共建筑，不应低于0.07MPa，多层住宅不宜低于0.05MPa。",[527,528],{"key":20,"text":208,"correct":22},{"key":24,"text":210,"correct":29},{"id":530,"libraryId":5,"type":203,"typeLabel":204,"stem":531,"options":532,"answer":208,"analysis":33},975402,"按照《建筑消防设施的维护管理》（GB25201）的规定，消防应急照明和疏散指示系统的检测内容主要是：切断正常供电，测量消防应急灯具照度，测试电源切换、充电、放电功能，测试应急电源的供电时间；通过报警联动，检查消防应急灯具自动投入功能。",[533,534],{"key":20,"text":208,"correct":29},{"key":24,"text":210,"correct":22},{"id":536,"libraryId":5,"type":60,"typeLabel":61,"stem":537,"options":538,"answer":549,"analysis":33},975404,"湿式自动喷水灭火系统的洒水喷头不宜选用隐蔽式洒水喷头，确需采用时，应仅适用于（ ）场所。",[539,541,543,545,547],{"key":20,"text":540,"correct":29},"中危险级Ⅰ级",{"key":24,"text":542,"correct":22},"中危险级Ⅱ级",{"key":27,"text":544,"correct":22},"严重危险级Ⅰ级",{"key":31,"text":546,"correct":22},"严重危险级Ⅱ级",{"key":73,"text":548,"correct":29},"轻危险级","AE",[551,554,557,560,563,566],{"id":15,"name":552,"category":7,"favorite":553},"领导干部任职前廉政法规知识测试题",92,{"id":555,"name":556,"category":7,"favorite":15},595,"建筑结构与设备",{"id":558,"name":559,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":561,"name":562,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":564,"name":565,"category":7,"favorite":8},534,"BIM工程师",{"id":567,"name":565,"category":7,"favorite":8},535]