[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-48":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":338},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,48,50,2486,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,320,332],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},975304,3,"判断题","消防电梯的电源应采用消防电源，并应在其配电线路的最末一级配电箱处设置自动切换装置。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},975305,"消防电梯应在轿顶设置一个轿厢安全窗，通过轿厢安全窗进入轿厢内不应被永久性的设备或照明灯具阻碍，并应提供从消防电梯轿厢内能完全打开轿厢安全窗的方式，如踩踏点或梯具等",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},975306,"消防员入口层可通过复位紧急迫降按钮，并在3s内再次按下按钮，使消防电梯返回到消防员入口层。",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},975307,"灯光疏散指示标志状态指示灯应正常。工作状态时，灯前通道地面中心的照度不应低于0.5lx。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},975308,"放电试验：检测时，使充电24h后的消防应急灯具由主电源供电状态转入应急工作状态，并持续至放电终止，用直流电压表测量在过放电保护启动瞬间电池（组）两端电压，与额定电压比较，电池放电终止电压应不小于额定电压的80%。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},975309,"安全出口、疏散出口附近设置的多信息复合标志灯，应安装在安全出口、疏散出口附近疏散走道、疏散通道的顶部。",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},975310,"楼层标志灯应安装在楼梯间内朝向楼梯的正面墙上，标志灯底边距地面的高度宜为1.8m～2.2m。",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},975311,"方向标志灯的标志面宜与疏散方向平行。",[68,69],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":25,"analysis":27},975312,"当安全出口或疏散门在疏散走道侧边时，在疏散走道增设的方向标志灯应安装在疏散走道的顶部，且标志灯的标志面应与疏散方向平行、箭头应指向安全出口或疏散门。",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":25,"analysis":27},975313,"当方向标志灯安装在疏散走道、通道上方时，室内高度不大于3.5m的场所，标志灯底边距地面的高度宜为2.5m～2.8m。",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},975314,"出口标志灯可安装在安全出口或疏散门两侧上方居中的位置。",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},975315,"自发光疏散指示标志当正常光源变暗后应自发光，其亮度应符合国家相关标准的要求，持续时间不应低于30min。",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},975316,"当方向标志灯安装在疏散走道、通道的地面上时，应安装在疏散走道、通道的靠右侧位置。",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},975317,"当方向标志灯安装在疏散走道、通道的地面上时，标志灯表面应与地面平行，高于地面距离不应大于5mm，标志灯边缘与地面垂直距离高度不应大于1mm。",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},975318,"钢筋混凝土消防水池（水箱）的进水管、出水管要加设防水套管，钢板等制作的消防水池（水箱）的进岀水等管道宜采用法兰连接，对有振动的管道应加设柔性接头。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},975319,"墙壁式消防水泵接合器设在建筑物的外墙上，其高出地面的距离不宜小于0.7m，井应与建筑物的门、窗、孔洞保持不小于1.0m的水平距离。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},975320,"消防水泵接合器接口的位置应方便操作，安装在便于消防车接近的人行道或非机动车行驶地段，距室外消火栓或消防水池的距离宜为5～40m。",[122,123],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},975321,"环状管道应用阀门分成若干独立段，每段内室外消火栓的数量不宜超过5个。",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},975322,"室外消防给水管道的直径应根据流量、流速和压力要求经计算确定，但不应小于DN100。",[134,135],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},975323,"当室外消防给水引入管设有倒流防止器，且发生火灾时因其水头损失导致室外消火栓不能满足压力和流量要求时，应在该倒流防止器前设置两个室外消火栓。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":25,"analysis":27},975324,"某地冰冻线为0.5m，室外消火栓系统管网采用埋地金属管道，管顶覆土深度为0.7m。",[146,147],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},975325,"埋地钢管和铸铁管应根据土壤和地下水腐蚀性等因素确定管外壁防锈措施。",[152,153],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":25,"analysis":27},975326,"室外消火栓的保护半径不应超过120m，并宜沿建筑周围均匀布置，且不宜集中布置在建筑一侧；建筑消防扑救面一侧的室外消火栓数量不宜少于2个。",[158,159],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":25,"analysis":27},975327,"室外消火栓具路边的距离为1.5m。",[164,165],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":25,"analysis":27},975328,"停车场的室外消火栓宜沿停车场周边设置，且与最近一排汽车的距离不应小于6.0m，距加油站或油库不应小于15.0m。",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":21,"analysis":27},975329,"甲、乙、丙类液体储罐区和液化炷储罐区等构筑物的室外消火栓，应设在防火堤或防护墙外，距罐壁15.0m范围内的消火栓，不应计算在该罐可使用的数量内。",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":25,"analysis":27},975330,"地下消火栓顶部进水口或顶部出水口应正对井口，顶部进水口或顶部出水口与消防井盖底面的距离不应大于0.4m，且不应小于井盖的半径。",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},975331,"室外地上消火栓安装时，消火栓顶距地面高为0.64m，各接口应便于连接和操作。",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":25,"analysis":27},975332,"室内消火栓系统管网应布置成环状，当室外消火栓设计流量不大于20L\u002FS，且室内消火栓不超过5个时，除国家有关规范规定的必须设置环状管网的情形外，可布置成枝状。",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},975333,"室内管网应采用阀门划分若干个独立段，保证检修管道时关闭停用的竖管不超过1根，当竖管超过4根时，可关闭不相邻的2根；每根竖管与供水横干管相接处应设置阀门。",[200,201],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":25,"analysis":27},975334,"室内消火栓管道穿过墙体或楼板时应加设套管，套管长度不应小于墙体厚度，或应高出楼面或地面20mm。",[206,207],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},975335,"建筑高度≤54m且每单元设置一部疏散楼梯的住宅，可采用1支消防水枪的1股充实水柱到达室内任何部位，消火栓的布置间距不应大于50.0m。",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},975336,"体积≤5000m3的丙、丁、戊类生产车间、自行车库，可采用1支消防水枪的1股充实水柱到达室内任何部位，消火栓的布置间距不应大于50.0m。",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},975337,"体积≤3000m3的丙、丁、戊类物品库房、图书资料档案库等，可采用1支消防水枪的1股充实水柱到达室内任何部位，消火栓的布置间距不应大于50.0m。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":27},975338,"消火栓阀门的设置位置应便于操作使用，阀门的中心距消火栓箱侧面为140mm，距箱后内表面为100mm，允许偏差为±3mm。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},975339,"室内消火栓的箱门的开启不应小于120°。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},975340,"消火栓栓口的静压不应大于1.2MPa，超过则应采取分区供水措施。",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":25,"analysis":27},975341,"风管接口的连接应严密、牢固，垫片厚度不应大于3mm，不应凸入管内和突岀到法兰外。",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":27},975342,"当风管穿越隔墙或楼板时，风管与隔墙之间的空隙应釆用水泥砂浆等不燃或难燃材料严密填塞。",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},975343,"吊顶内的排烟管道应釆用不燃材料隔热，并应与可燃物保持不小于150mm的距离。",[260,261],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},975344,"阀门应顺气流方向关闭，防火分区隔墙两侧的排烟防火阀距墙端面不应大于200mm。",[266,267],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},975345,"常闭送风口、排烟阀或排烟口的手动驱动装置固定安装在明显可见、距楼地面1.5m。",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":21,"analysis":27},975346,"活动挡烟垂壁与建筑结构（柱或墙）面的缝隙为50mm。",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},975347,"风机外壳至墙壁或其他设备的距离为500mm。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":27},975348,"当风口面积大于0.3m2时，对于矩形风口，按风口断面的大小划分成若干个面积相等的矩形，测点布置在每个小矩形的中心，至少取5个测点，小矩形每边的长度为200mm左右。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":21,"analysis":27},975349,"对于圆形风罩，至少取5个测点，测点间距不大于200mm。",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":25,"analysis":27},975350,"送风口风速不宜大于10m\u002Fs，排烟口的风速不宜大于7m\u002Fs，且偏差不大于设计值的10%。",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":306,"typeLabel":307,"stem":308,"options":309,"answer":20,"analysis":27},975351,1,"单选题","下列关于消防电梯前室的设置说法错误的是（ ）。",[310,312,314,317],{"key":20,"text":311,"correct":22},"设置消防电梯的场所应设置前室",{"key":24,"text":313,"correct":26},"前室宜靠外墙设置，并应在首层直通室外或经过长度不大于30m的通道通向室外",{"key":315,"text":316,"correct":26},"C","除前室的出入口、前室内设置的正压送风口和相应的户门外，前室内不应开设其他门、窗、洞口",{"key":318,"text":319,"correct":26},"D","前室或合用前室的门应釆用乙级防火门，不应设置卷帘",{"id":321,"libraryId":5,"type":306,"typeLabel":307,"stem":322,"options":323,"answer":20,"analysis":27},975352,"下列关于室内消火栓设备的安装布置要求说法正确的是（ ）。",[324,326,328,330],{"key":20,"text":325,"correct":22},"设置室内消火栓的建筑，包括设备层在内的各层均应设置消火栓",{"key":24,"text":327,"correct":26},"屋顶设有直升机停机坪的建筑，应在停机坪出入口处或非电气设备机房设置消火栓，且距停机坪机位边缘的距离不应大于5.0m",{"key":315,"text":329,"correct":26},"消防电梯前室应设置室内消火栓，可不计入消火栓使用数量",{"key":318,"text":331,"correct":26},"室内消火栓的布置应满足同一平面有2支消防水枪的2股充实水柱同时达到任何部位的要求，消火栓的布置间距不应大于25.0m",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":25,"analysis":27},975353,"防火卷帘的导轨应安装在建筑结构上，并应采用预埋螺栓、焊接或膨胀螺栓连接。导轨安装应牢固，固定点间距为8000mm。",[336,337],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[339,342,345,348,351,354],{"id":306,"name":340,"category":7,"favorite":341},"领导干部任职前廉政法规知识测试题",92,{"id":343,"name":344,"category":7,"favorite":306},595,"建筑结构与设备",{"id":346,"name":347,"category":7,"favorite":306},715,"招标采购专业知识与法律法规",{"id":349,"name":350,"category":7,"favorite":306},848,"市政方向-通用基础",{"id":352,"name":353,"category":7,"favorite":8},534,"BIM工程师",{"id":355,"name":353,"category":7,"favorite":8},535]