[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-47":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":567},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,47,50,2486,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,340,352,367,381,392,407,422,436,450,465,479,489,495,501,507,513,519,525,531,537,543,549,555,561],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},975254,1,"单选题","客房设置专用扬声器时，其功率不宜小于（ ）W。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1",true,{"key":24,"text":25,"correct":26},"B","2",false,{"key":28,"text":29,"correct":26},"C","3",{"key":31,"text":32,"correct":26},"D","4","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},975255,"应设置消防应急广插备用扩音机，其容量不小于火灾时需同时广播的范围内消防应急广播扬声器最大容量总和的（ ）倍，且应在消防应急广播时能够强行切入，并同时中断其他音源的传输。",[38,40,42,44],{"key":20,"text":39,"correct":26},"1.0",{"key":24,"text":41,"correct":22},"1.5",{"key":28,"text":43,"correct":26},"2.0",{"key":31,"text":45,"correct":26},"3.0",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},975256,"建筑内走道末端距最近的扬声器距离不应大于（ ）m。",[50,52,54,56],{"key":20,"text":51,"correct":26},"10",{"key":24,"text":53,"correct":22},"12.5",{"key":28,"text":55,"correct":26},"20",{"key":31,"text":57,"correct":26},"25",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},975257,"下列消防应急广播系统功能的检验方法不正确的有（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"在消防控制室应能用话筒对所选区域播音",{"key":24,"text":65,"correct":22},"在手动控制方式下，分别触发两个相关的火灾探测器或触发手动火灾报警按钮后，能按设定的控制程序自动启动火灾应急广播",{"key":28,"text":67,"correct":26},"在公共广播扩音机处于关闭和播放状态下，能自动和手动强制切换消防应急广播",{"key":31,"text":69,"correct":26},"火灾应急广播扬声器在其播放范围内最远点的播放声压级应高于背景噪声15dB",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},975258,"下列关于消防应急广播与其他广播系统合用时不符合设置要求的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"火灾发生时应能在消防控制室将全楼的扬声器和公共广播扩音机强制转入消防应急广播状态",{"key":24,"text":77,"correct":26},"消防控制室应能监控用于火灾应急广播的扩音机的工作状态",{"key":28,"text":79,"correct":26},"消防控制室应具有遥控开启扩音机和采用传声器播音的功能",{"key":31,"text":81,"correct":26},"客房床头控制柜内设有服务性的音乐广播扬声器时，应有消防应急广播功能",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},975259,"按照《建筑消防设施的维护管理》（GB25201）的要求，下面哪项不属于消防电话系统的检测内容（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"测试消防电话主机与电话分机之间的通话质量",{"key":24,"text":89,"correct":22},"测试消防控制室的外线电话与另外一部外线电话模拟报警电话通话功能",{"key":28,"text":91,"correct":26},"测试电话主机的录音功能",{"key":31,"text":93,"correct":26},"测试拨打“119”功能",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},975260,"下列关于电话分机或电话插孔的设置不符合规定的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"消防电话分机应固定安装在明显且便于使用的部位，并应有区别于普通电话的标识",{"key":24,"text":101,"correct":26},"设有手动火灾报警按钮或消火栓按钮等处宜设置电话插孔，并宜选择带有电话插孔的手动火灾报警按钮",{"key":28,"text":103,"correct":22},"各避难层应每隔30m设置一个消防电话分机或电话插孔",{"key":31,"text":105,"correct":26},"电话插孔在墙上安装时，其底边距地面高度宜为1.3～1.5m",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},975261,"下面哪项不是消防电话系统的检测方法：（ ）",[110,112,114,116],{"key":20,"text":111,"correct":26},"用消防电话通话，检查通话效果",{"key":24,"text":113,"correct":26},"用插孔电话呼叫消防控制室，检查通话效果",{"key":28,"text":115,"correct":26},"查看消防控制室、消防值班室、企业消防站等处的外线电话",{"key":31,"text":117,"correct":22},"查看消防水泵房、发电机房、配变电室等处的电话分机",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},975262,"下列民用可不设置消防电梯的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"建筑高度为33m的住宅",{"key":24,"text":125,"correct":26},"建筑高度为32m的医院门诊楼",{"key":28,"text":127,"correct":26},"建筑高度为33m的办公楼",{"key":31,"text":129,"correct":26},"建筑层数为5层，每层建筑面积为1200㎡的老年人照料设施",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},975263,"楼层标志灯应安装在楼梯间内朝向楼梯的正面墙上，标志灯底边距地面的高度宜为（ ）m。",[134,136,138,140],{"key":20,"text":135,"correct":26},"1.3～1.5",{"key":24,"text":137,"correct":26},"1.5～1.8",{"key":28,"text":139,"correct":26},"1.8～2.2",{"key":31,"text":141,"correct":22},"2.2～2.5",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},975264,"当方向标志灯安装在疏散走道、通道上方时，下列安装方法不符合规定的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"室内高度不大于3.5m的场所，标志灯底边距地面的高度宜为2.2m～2.5m",{"key":24,"text":149,"correct":26},"室内高度大于3.5m的场所，特大型、大型、中型标志灯底边距地面高度不宜小于3m，且不宜大于6m",{"key":28,"text":151,"correct":22},"室内高度不大于3.5m的办公楼，标志灯底边距地面的高度为2.0m",{"key":31,"text":153,"correct":26},"室内高度大于3.5m的展览馆，特大型、大型、中型标志灯底边距地面高度为3.5m",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},975265,"根据《建筑消防设施的维护管理》（GB25201）的规定，消防应急照明和疏散指示系统检测主要内容不包括（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":26},"切断正常供电，测量消防应急灯具照度",{"key":24,"text":161,"correct":22},"切断正常供电，测试电源充电、放电功能",{"key":28,"text":163,"correct":26},"切断正常供电，试应急电源的供电时间",{"key":31,"text":165,"correct":26},"通过报警联动，检查消防应急灯具自动投入功能",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},975266,"钢质防火卷帘帘板两端挡板或防窜机构应装配牢固，卷帘运行时，相邻帘板窜动量不应大于（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":26},"1mm",{"key":24,"text":173,"correct":22},"2mm",{"key":28,"text":175,"correct":26},"3mm",{"key":31,"text":177,"correct":26},"5mm",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},975267,"下列关于水泵接合器的安装要求不符合规定的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"组装式水泵接合器的安装，应按接口、本体、连接管、安全阀、止回阀、放空管、控制阀的顺序进行，止回阀的安装方向应使消防用水能从水泵接合器进入系统",{"key":24,"text":185,"correct":26},"墙壁消防水泵接合器的安装高度距地面宜为0.70m；与墙面上口的门、窗、孔、洞的净距离不应小于2.0m，且不应安装在玻璃幕墙下方",{"key":28,"text":187,"correct":26},"地下消防水泵接合器的安装，应使进水口与井盖底面的距离不大于0.4m，且不应小于井盖的半径",{"key":31,"text":189,"correct":26},"水泵接合器应设在室外便于消防车使用的地点，且距室外消火栓或消防水池的距离不宜小于15m，并不宜大于40m",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},975268,"下列关于高位消防水池设置在建筑物内时的分隔要求，说法正确的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":26},"应釆用耐火极限不低于2.00h的隔墙和1.00h的楼板与其他部位隔开，并应设甲级防火门",{"key":24,"text":197,"correct":22},"应釆用耐火极限不低于2.00h的隔墙和1.50h的楼板与其他部位隔开，并应设甲级防火门",{"key":28,"text":199,"correct":26},"应釆用耐火极限不低于2.00h的隔墙和1.00h的楼板与其他部位隔开，并应设乙级防火门",{"key":31,"text":201,"correct":26},"应釆用耐火极限不低于2.00h的隔墙和1.50h的楼板与其他部位隔开，并应设乙级防火门",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":28,"analysis":33},975269,"下列关于储存室外消防用水的消防水池或供消防车取水的消防水池的设置说法错误错误的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"应设置取水口（井），且吸水高度不应大于6.0m",{"key":24,"text":209,"correct":26},"取水口（井）与建筑物（水泵房除外）的距离不宜小于15m",{"key":28,"text":211,"correct":22},"与甲、乙、丙类液体储罐等构筑物的距离不宜小于60m",{"key":31,"text":213,"correct":26},"与液化石油气储罐采取防止辐射热保护措施时可为40m",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},975270,"下列关于消防水池（水箱）的安装要求说法错误的是（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"消防水池的给水管应根据其有效容积和补水时间确定，补水时间不宜大于96h",{"key":24,"text":221,"correct":26},"防水池进水管管径应通过计算确定，且不应小于DN100",{"key":28,"text":223,"correct":26},"消防水箱进水管的管径应满足消防水箱8h充满水的要求，但管径不应小于DN32，进水管宜设置液位阀或浮球阀",{"key":31,"text":225,"correct":26},"消防水池（水箱）出水管或水泵吸水管应满足最低有效水位出水不掺气的技术要求",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},975271,"下列关于消防水池（水箱）的设置说法错误的是（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":26},"无管道的侧面，净距不宜小于0.7m",{"key":24,"text":233,"correct":26},"有管道的侧面，净距宜小于1.0m，且管道外壁与建筑本体墙面之间的通道宽度不宜小于0.6m",{"key":28,"text":235,"correct":26},"设有人孔的池顶，顶板面与上面建筑本体板底的净空不应小于0.8m",{"key":31,"text":237,"correct":22},"在寒冷的场所，消防水箱设置房间的室内温度大于0℃",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":31,"analysis":33},975272,"高位消防水箱的设置位置应高于其所服务的水灭火设施，且最低有效水位应满足水灭火设施最不利点处的静水压力，下列关于最不利点处的静水压力说法错误的是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":26},"建筑高度为54m的办公楼最不利点处的静水压力不应低于0.10MPa",{"key":24,"text":245,"correct":26},"高层住宅建筑最不利点处的静水压力不应低于0.07MPa",{"key":28,"text":247,"correct":26},"多层商业建筑最不利点处的静水压力不应低于0.07MPa",{"key":31,"text":249,"correct":22},"工业建筑体积为20000m3时，不宜低于0.07MPa",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":33},975273,"气压水罐安装时其四周要设检修通道，其宽度不宜小于（ ）。",[254,256,258,260],{"key":20,"text":255,"correct":26},"0.5m",{"key":24,"text":257,"correct":26},"0.6m",{"key":28,"text":259,"correct":22},"0.7m",{"key":31,"text":261,"correct":26},"0.8m",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":31,"analysis":33},975274,"下列场所不可采用1支消防水枪的1股充实水柱到达室内任何部位的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":26},"建筑高度≤24m且体积≤5000m3的多层仓库",{"key":24,"text":269,"correct":26},"建筑高度≤54m且每单元设置一部疏散楼梯的住宅",{"key":28,"text":271,"correct":26},"体积≤1000m3的展览厅",{"key":31,"text":273,"correct":22},"体积≤5000m3的礼堂",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":31,"analysis":33},975275,"下列关于室内消火栓的安装要求说法错误的是（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":26},"消火栓箱体安装的垂直度允许偏差为±3mm",{"key":24,"text":281,"correct":26},"暗装的消火栓箱不能破坏隔墙的耐火等级；箱门的开启不应小于120°",{"key":28,"text":283,"correct":26},"栓口的安装高度应便于消防水带的连接和使用，其距地面高度宜为1.1m，允许偏差为±20mm",{"key":31,"text":285,"correct":22},"消火栓阀门的设置位置应便于操作使用，阀门的中心距消火栓箱侧面为100mm",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":24,"analysis":33},975276,"设有高位消防箱出水管流量开关或消防水泵出水干管压力开关的，消防水泵应能在（ ）内自动启动。",[290,292,294,296],{"key":20,"text":291,"correct":26},"1min",{"key":24,"text":293,"correct":22},"2min",{"key":28,"text":295,"correct":26},"5min",{"key":31,"text":297,"correct":26},"10min",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":20,"analysis":33},975277,"下列关于风管的安装质量要求说法错误的是（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":22},"风管接口的连接应严密、牢固，垫片厚度不应小于2mm",{"key":24,"text":305,"correct":26},"排烟风管法兰垫片应为不燃材料，薄钢板法兰风管应釆用螺栓连接",{"key":28,"text":307,"correct":26},"当风管穿越隔墙或楼板时，风管与隔墙之间的空隙应釆用水泥砂浆等不燃材料严密填塞",{"key":31,"text":309,"correct":26},"吊顶内的排烟管道应釆用不燃材料隔热，并应与可燃物保持不小于150mm的距离",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},975278,"下列关于排烟防火阀的安装质量要求说法错误的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":26},"阀门应顺气流方向关闭",{"key":24,"text":317,"correct":22},"防火分区隔墙两侧的排烟防火阀距墙端面不应大于2.00m",{"key":28,"text":319,"correct":26},"手动和电动装置应灵活、可靠，阀门关闭严密",{"key":31,"text":321,"correct":26},"应设独立的支、吊架，当风管采用不燃材料防火隔热时，阀门安装处应有明显标识",{"id":323,"libraryId":5,"type":324,"typeLabel":325,"stem":326,"options":327,"answer":339,"analysis":33},975279,2,"多选题","下列关于消防应急广播扬声器的安装说法正确的是（ ）。",[328,330,332,334,336],{"key":20,"text":329,"correct":22},"民用建筑内扬声器应设置在走道和大厅等公共场所，每个扬声器的额定功率不应小于3W",{"key":24,"text":331,"correct":22},"客房设置专用扬声器时，其功率不宜小于1W",{"key":28,"text":333,"correct":26},"当扬声器采用壁挂方式安装时，其底边距地高度为2.2m",{"key":31,"text":335,"correct":26},"民用建筑内走道末端距最近的扬声器距离不应大于15m",{"key":337,"text":338,"correct":26},"E","民用建筑内扬声器数量应能保证从一个防火分区内的任何部位到最近一个扬声器的直线距离不大于30m","AB",{"id":341,"libraryId":5,"type":324,"typeLabel":325,"stem":342,"options":343,"answer":351,"analysis":33},975280,"消防应急广播系统功能的检验方法正确的有：（ ）。",[344,345,346,348,349],{"key":20,"text":63,"correct":22},{"key":24,"text":65,"correct":26},{"key":28,"text":347,"correct":26},"核对启动火灾应急广播的区域，播音区域应正确、音质应清晰",{"key":31,"text":67,"correct":22},{"key":337,"text":350,"correct":22},"用声级计测试启动火灾应急广播前的环境噪声，当环境噪声大于60dB时，火灾应急广播扬声器在其播放范围内最远点的播放声压级应高于背景噪声15dB","ADE",{"id":353,"libraryId":5,"type":324,"typeLabel":325,"stem":354,"options":355,"answer":366,"analysis":33},975281,"下列关于消防应急广播系统各组件安装质量的检查方法正确的有（ ）。",[356,358,360,362,364],{"key":20,"text":357,"correct":22},"系统各组件、设备的永久性铭牌和按规定设置的标识，其文字和数据应齐全、符号应清晰、色标应正确",{"key":24,"text":359,"correct":22},"以手动方式在消防控制室对所有广播分区进行选区广播，对所有共用扬声器进行强行切换，应急广播应以最大功率输出",{"key":28,"text":361,"correct":22},"对扩音机和备用扩音机进行全负荷试验，应急广播的语音应清晰",{"key":31,"text":363,"correct":26},"对接入联动控制系统的消防应急广播设备系统，使其处于“手动”工作状态，然后按设计的逻辑关系检査应急广播的工作情况，系统应按设计的逻辑广播",{"key":337,"text":365,"correct":22},"每一回路抽查一个扬声器。使任意一个扬声器断路，其他扬声器的工作状态不应受影响","ABCE",{"id":368,"libraryId":5,"type":324,"typeLabel":325,"stem":369,"options":370,"answer":366,"analysis":33},975282,"下列关于消防电话各组件的设置要求说法正确的有（ ）。",[371,373,375,377,379],{"key":20,"text":372,"correct":22},"消防专用电话网络应为独立的消防通信系统",{"key":24,"text":374,"correct":22},"消防控制室应设置消防电话总机",{"key":28,"text":376,"correct":22},"多线制消防电话系统中的每个电话分机应与总机单独连接",{"key":31,"text":378,"correct":26},"消防水泵房应设置应设置可直接报警的外线电话",{"key":337,"text":380,"correct":22},"消防控制室、消防值班室或企业消防站等处，应设置可直接报警的外线电话",{"id":382,"libraryId":5,"type":324,"typeLabel":325,"stem":383,"options":384,"answer":391,"analysis":33},975283,"消防电话系统的检测方法：（ ）。",[385,386,387,388,389],{"key":20,"text":111,"correct":22},{"key":24,"text":113,"correct":22},{"key":28,"text":115,"correct":22},{"key":31,"text":117,"correct":26},{"key":337,"text":390,"correct":26},"检查消防电话系统群呼、录音等功能","ABC",{"id":393,"libraryId":5,"type":324,"typeLabel":325,"stem":394,"options":395,"answer":406,"analysis":33},975284,"下列关于高位消防水箱的设置说法正确的（ ）。",[396,398,400,402,404],{"key":20,"text":397,"correct":26},"消防水箱宜设置支墩，支墩的高度不宜小于0.7m",{"key":24,"text":399,"correct":22},"消防水池（水箱）及附属管道安装前，应清理其内部污垢和杂物",{"key":28,"text":401,"correct":22},"钢筋混凝土消防水池（水箱）的进水管、出水管要加设防水套管，钢板等制作的消防水池（水箱）的进岀水等管道宜采用法兰连接",{"key":31,"text":403,"correct":22},"组合式消防水池（水箱）的进水管、出水管接头宜采用法兰连接",{"key":337,"text":405,"correct":26},"消防水池（水箱）应设置就地水位显示装置，并应在消防控制中心或值班室等地点设置显示消防水池（水箱）水位的装置，同时应有最高、最低、和正常报警水位","BCD",{"id":408,"libraryId":5,"type":324,"typeLabel":325,"stem":409,"options":410,"answer":421,"analysis":33},975285,"下列关于消防增（稳）压设施的安装要求说法正确的是（ ）。",[411,413,415,417,419],{"key":20,"text":412,"correct":22},"气压水罐宜安装有效水容积指示器",{"key":24,"text":414,"correct":26},"消防气压给水设备顶部至楼板或梁底的距离不宜小于0.8m",{"key":28,"text":416,"correct":22},"稳压泵在1h内的启停次数应符合设计要求，并不宜大于15次",{"key":31,"text":418,"correct":26},"稳压泵吸水管应设置暗杆闸阀",{"key":337,"text":420,"correct":26},"稳压泵出水管应设置消声止回阀","AC",{"id":423,"libraryId":5,"type":324,"typeLabel":325,"stem":424,"options":425,"answer":351,"analysis":33},975286,"下列关于室外消火栓的安装说法正确的是（ ）。",[426,428,430,432,434],{"key":20,"text":427,"correct":22},"埋地金属管道在机动车道下时，管道最小管顶覆土应经计算确定，且不应小于0.90m，管道最小管顶覆土应至少在冰冻线以下0.30m",{"key":24,"text":429,"correct":26},"埋地管道采用钢丝网骨架塑料复合管时，其最小管顶覆土深度，在轻型车行道下不应小于0.7m，且应在冰冻线下0.3m",{"key":28,"text":431,"correct":26},"埋地管道采用钢丝网骨架塑料复合管时，在重型汽车道路下应设置保护套管，套管与钢丝网骨架塑料复合管的净距不应小于200mm",{"key":31,"text":433,"correct":22},"当埋地管直径不小于DN100时，应在管道弯头、三通和堵头等位置设置钢筋混凝土支墩",{"key":337,"text":435,"correct":22},"架空充水管道应设置在环境温度不低于5℃的区域，当环境温度低于5℃时，应釆取防冻措施",{"id":437,"libraryId":5,"type":324,"typeLabel":325,"stem":438,"options":439,"answer":449,"analysis":33},975287,"下列关于室内消火栓的安装说法正确的是（ ）。",[440,442,444,445,447],{"key":20,"text":441,"correct":22},"室内消火栓的选型应符合使用者、火灾危险性、火灾类型和灭火功能要求",{"key":24,"text":443,"correct":26},"同一建筑物内设置的消火栓应采用统一生产厂家的栓口、水枪、水带及配件",{"key":28,"text":283,"correct":22},{"key":31,"text":446,"correct":26},"阀门的中心距消火栓箱侧面为140mm，距箱后内表面为100mm，允许偏差为±3mm",{"key":337,"text":448,"correct":22},"设有室内消火栓的建筑应设置带有压力表的试验消火栓","ACE",{"id":451,"libraryId":5,"type":324,"typeLabel":325,"stem":452,"options":453,"answer":464,"analysis":33},975288,"下列关于消火栓系统最不利点处消火栓栓口的静压的说法错误的是（ ）。",[454,456,458,460,462],{"key":20,"text":455,"correct":22},"某建筑高度为164m的综合建筑最不利点处消火栓栓口的静压不应低于0.10MPa",{"key":24,"text":457,"correct":26},"建筑高度为32m的办公建筑，最不利点处消火栓栓口的静压不应低于0.07MPa",{"key":28,"text":459,"correct":22},"当工业建筑建筑体积为20000m3时，最不利点处消火栓栓口的静压不宜低于0.07MPa",{"key":31,"text":461,"correct":22},"采用稳压泵稳压时，最不利点处水灭火设施在准工作状态时的静水压力不应小于0.15MPa",{"key":337,"text":463,"correct":26},"多层住宅最不利点处消火栓栓口的静压不宜低于0.07MPa","ACD",{"id":466,"libraryId":5,"type":324,"typeLabel":325,"stem":467,"options":468,"answer":351,"analysis":33},975289,"下列关于风机的安装质量要求说法正确的是（ ）。",[469,471,473,475,477],{"key":20,"text":470,"correct":22},"风机外壳至墙壁或其他设备的距离不应小于600mm",{"key":24,"text":472,"correct":26},"风机应设在混凝土或钢架基础上，可设置减振装置",{"key":28,"text":474,"correct":26},"若排烟系统与通风空调系统共用且需要设置减振装置时，可使用橡胶减振装置",{"key":31,"text":476,"correct":22},"风机驱动装置的外露部位应装设防护罩",{"key":337,"text":478,"correct":22},"直通大气的进、出风口应装设防护网或采取其他安全设施，并应设防雨措施",{"id":480,"libraryId":5,"type":481,"typeLabel":482,"stem":483,"options":484,"answer":486,"analysis":33},975290,3,"判断题","消防电源是指在火灾时能保证消防用电设备继续正常运行的电源。",[485,487],{"key":20,"text":486,"correct":22},"正确",{"key":24,"text":488,"correct":26},"错误",{"id":490,"libraryId":5,"type":481,"typeLabel":482,"stem":491,"options":492,"answer":488,"analysis":33},975291,"在通过扬声器进行应急广播时，应自动对广播内容进行录音。",[493,494],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":496,"libraryId":5,"type":481,"typeLabel":482,"stem":497,"options":498,"answer":488,"analysis":33},975292,"在消防控制室应能手动或按预设控制逻辑联动控制选择广播分区，启动消防应急广播系统，井应能监听消防应急广播。",[499,500],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":502,"libraryId":5,"type":481,"typeLabel":482,"stem":503,"options":504,"answer":488,"analysis":33},975293,"对消防应急广播系统的线路进行检查，对于错线、开路、虚焊、短路、绝缘电阻大于20MΩ等问题，应采取相应的处理措施，以确保系统运行的稳定性和可靠性。",[505,506],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":508,"libraryId":5,"type":481,"typeLabel":482,"stem":509,"options":510,"answer":488,"analysis":33},975294,"以自动方式在消防控制室对所有广播分区进行选区广播，对所有共用扬声器进行强行切换，应急广播应以最大功率输出。",[511,512],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":514,"libraryId":5,"type":481,"typeLabel":482,"stem":515,"options":516,"answer":488,"analysis":33},975295,"扬声器安装应牢固可靠，表面不应有破损。当扬声器采用壁挂方式安装时，其底边距地高度应大于2.0m。",[517,518],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":520,"libraryId":5,"type":481,"typeLabel":482,"stem":521,"options":522,"answer":488,"analysis":33},975296,"消防应急广播系统各组件检查时，要确保系统组件的规格、型号与设计文件一致。",[523,524],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":526,"libraryId":5,"type":481,"typeLabel":482,"stem":527,"options":528,"answer":488,"analysis":33},975297,"民用建筑内扬声器应设置在走道和大厅等公共场所。每个扬声器的额定功率不应小于3W，其数量应能保证从一个防火分区内的任何部位到最近一个扬声器的直线距离不大于30m，走道末端距最近的扬声器距离不应大于15m。",[529,530],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":532,"libraryId":5,"type":481,"typeLabel":482,"stem":533,"options":534,"answer":488,"analysis":33},975298,"消防应急广播系统应与火灾声警报器分时交替工作，可采取1次火灾声警报器播放、1次消防应急广播播放的交替工作方式循环播放。",[535,536],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":538,"libraryId":5,"type":481,"typeLabel":482,"stem":539,"options":540,"answer":488,"analysis":33},975299,"在消防控制室应能显示消防应急广播的广播分区的开始状态。",[541,542],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":544,"libraryId":5,"type":481,"typeLabel":482,"stem":545,"options":546,"answer":488,"analysis":33},975300,"消防电话、电话插孔、带电话插孔的手动火灾报警按钮宜安装在靠门的位置。",[547,548],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":550,"libraryId":5,"type":481,"typeLabel":482,"stem":551,"options":552,"answer":488,"analysis":33},975301,"消防电梯的井底排水泵的排水量不应小于2L\u002Fs。",[553,554],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":556,"libraryId":5,"type":481,"typeLabel":482,"stem":557,"options":558,"answer":488,"analysis":33},975302,"消防电梯井底排水泵集水井的有效容量不应小于10m3。",[559,560],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},{"id":562,"libraryId":5,"type":481,"typeLabel":482,"stem":563,"options":564,"answer":488,"analysis":33},975303,"消防电梯井、机房与相邻电梯井、机房之间应设置耐火极限不低于3.0h的防火隔墙，隔墙上的门应采用甲级防火门。",[565,566],{"key":20,"text":486,"correct":26},{"key":24,"text":488,"correct":22},[568,571,574,577,580,583],{"id":15,"name":569,"category":7,"favorite":570},"领导干部任职前廉政法规知识测试题",92,{"id":572,"name":573,"category":7,"favorite":15},595,"建筑结构与设备",{"id":575,"name":576,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":578,"name":579,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":581,"name":582,"category":7,"favorite":8},534,"BIM工程师",{"id":584,"name":582,"category":7,"favorite":8},535]