[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-45":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":564},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,45,50,2486,[13,37,53,63,69,75,81,87,93,99,105,111,117,123,129,143,155,167,179,191,203,215,227,239,251,263,271,283,295,307,319,331,343,355,367,379,391,403,413,421,433,443,455,467,475,490,505,520,535,549],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":35,"analysis":36},975153,2,"多选题","下列关于自动喷水灭火系统连锁控制的测试方法描述正确的有（ ）。",[19,23,26,29,32],{"key":20,"text":21,"correct":22},"A","通过开启末端试水装置模拟喷头动作",true,{"key":24,"text":25,"correct":22},"B","通过开启报警阀泄水阀模拟喷头动作",{"key":27,"text":28,"correct":22},"C","使报警阀在压差作用下开启，压力水流入报警管路",{"key":30,"text":31,"correct":22},"D","压力开关作后直接启动消防水泵",{"key":33,"text":34,"correct":22},"E","也可通过开启警铃试验阀，直接驱动压力开关动作并连锁启动消防水泵","ABCDE","",{"id":38,"libraryId":5,"type":15,"typeLabel":16,"stem":39,"options":40,"answer":52,"analysis":36},975154,"下列关于自动喷水灭火系统联动控制的测试方法自动喷水灭火系统测试方法描述正确的有（ ）。",[41,43,45,48,50],{"key":20,"text":42,"correct":22},"通过开启末端试水装置、报警阀泄水阀、警铃试验阀、专用测试管路或报警阀压力开关、压力开关配用输入模块模拟等方式产生报警阀压力开关动作信号",{"key":24,"text":44,"correct":22},"通过使用火灾探测器测试装置触发该报警阀所在防护区域内任一火灾探测器或启动任一手动火灾报警按钮产生报警信号",{"key":27,"text":46,"correct":47},"通过使用火灾探测器测试装置触发该报警阀所在建筑内任一火灾探测器或启动任一手动火灾报警按钮产生报警信号",false,{"key":30,"text":49,"correct":22},"在接到压力开关动作信号和报警信号后，消防联动控制器发出消防水泵启动信",{"key":33,"text":51,"correct":22},"通过开启警铃试验阀，直接驱动压力开关动作并启动消防水泵。","ABDE",{"id":54,"libraryId":5,"type":55,"typeLabel":56,"stem":57,"options":58,"answer":60,"analysis":36},975155,3,"判断题","湿式系统和干式系统洒水喷头的公称动作温度宜高于环境最高温度30℃。",[59,61],{"key":20,"text":60,"correct":22},"正确",{"key":24,"text":62,"correct":47},"错误",{"id":64,"libraryId":5,"type":55,"typeLabel":56,"stem":65,"options":66,"answer":60,"analysis":36},975156,"顶板为水平面的轻危险级、中危险级Ⅰ级住宅建筑、宿舍、旅馆建筑客房、医疗建筑病房和办公室，湿式系统可采用边墙型洒水喷头。",[67,68],{"key":20,"text":60,"correct":22},{"key":24,"text":62,"correct":47},{"id":70,"libraryId":5,"type":55,"typeLabel":56,"stem":71,"options":72,"answer":60,"analysis":36},975157,"干式系统应采用直立型洒水喷头或干式下垂型洒水喷头。",[73,74],{"key":20,"text":60,"correct":22},{"key":24,"text":62,"correct":47},{"id":76,"libraryId":5,"type":55,"typeLabel":56,"stem":77,"options":78,"answer":60,"analysis":36},975158,"其他系统接入湿式系统时，应分别设置独立的报警阀组，其控制的洒水喷头数计入湿式报警阀组控制的洒水喷头总数。",[79,80],{"key":20,"text":60,"correct":22},{"key":24,"text":62,"correct":47},{"id":82,"libraryId":5,"type":55,"typeLabel":56,"stem":83,"options":84,"answer":60,"analysis":36},975159,"每个报警阀组供水的最高与最低位置洒水喷头，其高程差不宜大于50m。",[85,86],{"key":20,"text":60,"correct":22},{"key":24,"text":62,"correct":47},{"id":88,"libraryId":5,"type":55,"typeLabel":56,"stem":89,"options":90,"answer":62,"analysis":36},975160,"湿式、干式自动喷水灭火系统联动控制方式不受消防联动控制器处于自动或手动状态影响。",[91,92],{"key":20,"text":60,"correct":47},{"key":24,"text":62,"correct":22},{"id":94,"libraryId":5,"type":55,"typeLabel":56,"stem":95,"options":96,"answer":62,"analysis":36},975161,"需要火灾自动报警系统联动控制的消防设备，其联动触发信号应采用两个不同的报警触发装置报警信号的“与”逻辑组合。",[97,98],{"key":20,"text":60,"correct":47},{"key":24,"text":62,"correct":22},{"id":100,"libraryId":5,"type":55,"typeLabel":56,"stem":101,"options":102,"answer":62,"analysis":36},975162,"联动控制方式不受消防联动控制器处于自动或手动状态影响。",[103,104],{"key":20,"text":60,"correct":47},{"key":24,"text":62,"correct":22},{"id":106,"libraryId":5,"type":55,"typeLabel":56,"stem":107,"options":108,"answer":62,"analysis":36},975163,"通过开启报警阀泄水阀，直接驱动压力开关动作并连锁启动消防水泵。",[109,110],{"key":20,"text":60,"correct":47},{"key":24,"text":62,"correct":22},{"id":112,"libraryId":5,"type":55,"typeLabel":56,"stem":113,"options":114,"answer":60,"analysis":36},975164,"连锁控制测时，通过开启末端试水装置、报警阀泄水阀或专用测试管路等方式模拟喷头动作，使报警阀在压差作用下开启，压力水流入报警管路，压力开关作后直接启动消防水泵。",[115,116],{"key":20,"text":60,"correct":22},{"key":24,"text":62,"correct":47},{"id":118,"libraryId":5,"type":55,"typeLabel":56,"stem":119,"options":120,"answer":60,"analysis":36},975165,"湿式报警阀组报警功能可通过末端试水装置、专用测试管路、报警阀泄水阀、警铃试验阀等途径进行测试。利用末端试水装置测试时，水流指示器动作，报警阀阀瓣打开，水力警铃动作，压力开关动作，消防水泵启动。",[121,122],{"key":20,"text":60,"correct":22},{"key":24,"text":62,"correct":47},{"id":124,"libraryId":5,"type":55,"typeLabel":56,"stem":125,"options":126,"answer":60,"analysis":36},975166,"建筑净空高度为8m的民用建筑，采用流量系数K=80的标准响应喷头。",[127,128],{"key":20,"text":60,"correct":22},{"key":24,"text":62,"correct":47},{"id":130,"libraryId":5,"type":131,"typeLabel":132,"stem":133,"options":134,"answer":30,"analysis":36},975167,1,"单选题","建筑内从一个防火分区内的任何部位到最近一个扬声器的直线距离不大于（ ）m。",[135,137,139,141],{"key":20,"text":136,"correct":47},"10",{"key":24,"text":138,"correct":47},"12.5",{"key":27,"text":140,"correct":47},"20",{"key":30,"text":142,"correct":22},"25",{"id":144,"libraryId":5,"type":131,"typeLabel":132,"stem":145,"options":146,"answer":27,"analysis":36},975168,"民用建筑内扬声器应设置在走道和大厅等公共场所。每个扬声器的额定功率不应小于（ ）W。",[147,149,151,153],{"key":20,"text":148,"correct":47},"1",{"key":24,"text":150,"correct":47},"2",{"key":27,"text":152,"correct":22},"3",{"key":30,"text":154,"correct":47},"4",{"id":156,"libraryId":5,"type":131,"typeLabel":132,"stem":157,"options":158,"answer":24,"analysis":36},975169,"下面消防应急广播扬声器的安装错误的是（ ）。",[159,161,163,165],{"key":20,"text":160,"correct":47},"在走道和大厅等公共场所，每个扬声器的额定功率不应小于3W",{"key":24,"text":162,"correct":22},"客房设置专用扬声器时，其功率不宜小于3W",{"key":27,"text":164,"correct":47},"当扬声器采用壁挂方式安装时，其底边距地高度应大于2.2m",{"key":30,"text":166,"correct":47},"从一个防火分区内的任何部位到最近一个扬声器的直线距离不大于25m",{"id":168,"libraryId":5,"type":131,"typeLabel":132,"stem":169,"options":170,"answer":30,"analysis":36},975170,"不属于消防应急广播的联动控制要求的有（ ）。",[171,173,175,177],{"key":20,"text":172,"correct":47},"在消防控制室应能手动控制选择广播分区",{"key":24,"text":174,"correct":47},"在消防控制室应能按预设控制逻辑联动控制选择广播分区",{"key":27,"text":176,"correct":47},"在消防控制室应能启动或停止消防应急广播系统",{"key":30,"text":178,"correct":22},"在应能消防控制室监视消防应急广播",{"id":180,"libraryId":5,"type":131,"typeLabel":132,"stem":181,"options":182,"answer":27,"analysis":36},975171,"下列关于消防电话各组件的安装要求不正确的是（ ）。",[183,185,187,189],{"key":20,"text":184,"correct":47},"消防电话、电话插孔宜安装在明显、便于操作的位置",{"key":24,"text":186,"correct":47},"带电话插孔的手动火灾报警按钮宜安装在明显、便于操作的位置",{"key":27,"text":188,"correct":22},"当在墙面上安装时，其底边距地（楼）面高度宜为1.5-1.8m",{"key":30,"text":190,"correct":47},"消防电话和电话插孔应有明显的永久性标识",{"id":192,"libraryId":5,"type":131,"typeLabel":132,"stem":193,"options":194,"answer":24,"analysis":36},975172,"下列关于消防电话系统各组件安装质量的检查方法不正确的是（ ）。",[195,197,199,201],{"key":20,"text":196,"correct":47},"应检查消防电话线路是否为独立布线",{"key":24,"text":198,"correct":22},"在消防控制室总机与所有消防电话分机、电话插孔之间互相呼叫并通话，总机应能显示关键分机或电话插孔的位置",{"key":27,"text":200,"correct":47},"消防控制室的外线电话与另外一部外线电话模拟报警电话通话，语音应清晰",{"key":30,"text":202,"correct":47},"检查消防电话系统群呼、录音等功能，各项功能均应符合要求",{"id":204,"libraryId":5,"type":131,"typeLabel":132,"stem":205,"options":206,"answer":24,"analysis":36},975173,"下列关于消防电梯井、机房与相邻电梯井、机房之间的分隔，下列说法正确的是（ ）。",[207,209,211,213],{"key":20,"text":208,"correct":47},"应设置耐火极限不低于3.0h的防火隔墙，隔墙上的门应采用甲级防火门",{"key":24,"text":210,"correct":22},"应设置耐火极限不低于2.0h的防火隔墙，隔墙上的门应采用甲级防火门",{"key":27,"text":212,"correct":47},"应设置耐火极限不低于2.0h的防火隔墙，隔墙上的门应采用乙级防火门",{"key":30,"text":214,"correct":47},"应设置耐火极限不低于3.0h的防火隔墙，隔墙上的门应采用乙级防火门",{"id":216,"libraryId":5,"type":131,"typeLabel":132,"stem":217,"options":218,"answer":20,"analysis":36},975174,"下列关于消防电梯的井底应设置排水设施，排水井的容量和排水泵的排水量分别不应小于（ ）。",[219,221,223,225],{"key":20,"text":220,"correct":22},"2m3；10L\u002Fs",{"key":24,"text":222,"correct":47},"10m3；2L\u002Fs",{"key":27,"text":224,"correct":47},"5m3；10L\u002Fs",{"key":30,"text":226,"correct":47},"10m3；5L\u002Fs",{"id":228,"libraryId":5,"type":131,"typeLabel":132,"stem":229,"options":230,"answer":27,"analysis":36},975175,"下列关于应急照明控制器、集中电源、应急照明配电箱的描述错误的是（ ）。",[231,233,235,237],{"key":20,"text":232,"correct":47},"应急照明控制器、集中电源、应急照明配电箱应安装牢固，不得倾斜",{"key":24,"text":234,"correct":47},"落地安装时，其底边宜高出地（楼）面100～200mm",{"key":27,"text":236,"correct":22},"设备在电气竖井内安装时，应采用上出口进线方式，设备接地应牢固，并设置明显标识",{"key":30,"text":238,"correct":47},"应急照明控制器主电源应设置明显的永久性标识，并应直接与消防电源连接，严禁使用电源插头",{"id":240,"libraryId":5,"type":131,"typeLabel":132,"stem":241,"options":242,"answer":24,"analysis":36},975176,"疏散指示标志灯安装高度距地面不大于1m时，凸出墙面或柱面最大水平距离不应超过（ ）。",[243,245,247,249],{"key":20,"text":244,"correct":47},"10mm",{"key":24,"text":246,"correct":22},"20mm",{"key":27,"text":248,"correct":47},"30mm",{"key":30,"text":250,"correct":47},"50mm",{"id":252,"libraryId":5,"type":131,"typeLabel":132,"stem":253,"options":254,"answer":30,"analysis":36},975177,"单帘面卷帘的两根导轨应互相平行，双帘面卷帘不同帘面的导轨也应互相平行，其平行度误差均不应大于（ ）。",[255,257,259,261],{"key":20,"text":256,"correct":47},"1mm",{"key":24,"text":258,"correct":47},"2mm",{"key":27,"text":260,"correct":47},"3mm",{"key":30,"text":262,"correct":22},"5mm",{"id":264,"libraryId":5,"type":131,"typeLabel":132,"stem":265,"options":266,"answer":24,"analysis":36},975178,"门楣内的防烟装置与卷帘帘板或帘面表面应均匀紧密贴合，其贴合面长度不应小于门楣长度的80%，非贴合部位的缝隙不应大于（ ）。",[267,268,269,270],{"key":20,"text":256,"correct":47},{"key":24,"text":258,"correct":22},{"key":27,"text":260,"correct":47},{"key":30,"text":262,"correct":47},{"id":272,"libraryId":5,"type":131,"typeLabel":132,"stem":273,"options":274,"answer":24,"analysis":36},975179,"防火卷帘控制器及手动按钮盒的安装应牢固可靠，其底边距地面高度宜为（ ）。",[275,277,279,281],{"key":20,"text":276,"correct":47},"1.1～1.3m",{"key":24,"text":278,"correct":22},"1.3～1.5m",{"key":27,"text":280,"correct":47},"1.5～1.8m",{"key":30,"text":282,"correct":47},"1.8～2.0m",{"id":284,"libraryId":5,"type":131,"typeLabel":132,"stem":285,"options":286,"answer":27,"analysis":36},975180,"下列关于防火门的基础安装说法错误的是（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":47},"设置在变形缝附近的防火门，应安装在楼层数较多的一侧",{"key":24,"text":290,"correct":47},"防火门门扇开启后不应跨越变形缝",{"key":27,"text":292,"correct":22},"钢质防火门门框内应充填水泥砂浆，门框与墙体应用预埋钢件或膨胀螺栓等连接牢固，其固定点间距不宜小于600mm",{"key":30,"text":294,"correct":47},"防火门门框与门扇、门扇与门扇的缝隙处嵌装的防火密封件应牢固、完好",{"id":296,"libraryId":5,"type":131,"typeLabel":132,"stem":297,"options":298,"answer":27,"analysis":36},975181,"下列关于防火门监控器的安装说法错误的是（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":47},"防火门监控器应设置在消防控制室内，未设置消防控制室时，应设置在有人值班的场所",{"key":24,"text":302,"correct":47},"电动开门器的手动控制按钮应设置在防火门内侧墙面上，距门不宜超过0.5m",{"key":27,"text":304,"correct":22},"电动开门器的手动控制按钮应设置在防火门内侧墙面上，底边距地面高度宜为1.3～1.5m",{"key":30,"text":306,"correct":47},"防火门监控器的设置应符合火灾报警控制器的安装设置要求",{"id":308,"libraryId":5,"type":131,"typeLabel":132,"stem":309,"options":310,"answer":20,"analysis":36},975182,"防火卷帘卷门机应具有依靠防火卷帘自重恒速下降功能，其不需要太大的操作臂力，其臂力规定不得大于（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":22},"70N",{"key":24,"text":314,"correct":47},"75N",{"key":27,"text":316,"correct":47},"80N",{"key":30,"text":318,"correct":47},"85N",{"id":320,"libraryId":5,"type":131,"typeLabel":132,"stem":321,"options":322,"answer":24,"analysis":36},975183,"高层建筑、厂房、库房和室内净空高度超过8m的民用建筑等场所，消火栓栓口动压不应小于（ ），且消防水枪充实水柱应按（ ）m计算。",[323,325,327,329],{"key":20,"text":324,"correct":47},"0.35MPa；10m",{"key":24,"text":326,"correct":22},"0.35MPa；13m",{"key":27,"text":328,"correct":47},"0.25MPa；10m",{"key":30,"text":330,"correct":47},"0.25MPa；13m",{"id":332,"libraryId":5,"type":131,"typeLabel":132,"stem":333,"options":334,"answer":24,"analysis":36},975184,"下列关于室外消火栓系统管网的布置说法错误的是（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":47},"室外消防给水采用两路消防供水时应采用环状管网",{"key":24,"text":338,"correct":22},"环状管道应用阀门分成若干独立段，每段内室外消火栓的数量不宜超过3个",{"key":27,"text":340,"correct":47},"室外消防给水管道的直径应根据流量、流速和压力要求经计算确定，但不应小于DN100",{"key":30,"text":342,"correct":47},"当室外消防给水引入管设有倒流防止器，且发生火灾时因其水头损失导致室外消火栓不能满足压力和流量要求时，应在该倒流防止器前设置一个室外消火栓",{"id":344,"libraryId":5,"type":131,"typeLabel":132,"stem":345,"options":346,"answer":27,"analysis":36},975185,"下列关于室外消火栓系统管网的安装要求的说法错误的是（ ）。",[347,349,351,353],{"key":20,"text":348,"correct":47},"埋地金属管道的最小管顶覆土不应小于0.70m",{"key":24,"text":350,"correct":47},"当在机动车道下时管道最小管顶覆土应经计算确定，且不应小于0.90m",{"key":27,"text":352,"correct":22},"埋地金属管道最小管顶覆土应至少在冰冻线以下0.20m",{"key":30,"text":354,"correct":47},"埋地管道采用钢丝网骨架塑料复合管时，其最小管顶覆土深度，在人行道下不应小于0.80m，且应在冰冻线下0.3m",{"id":356,"libraryId":5,"type":131,"typeLabel":132,"stem":357,"options":358,"answer":20,"analysis":36},975187,"人防工程、地下工程等建筑应在出入口附近设置室外消火栓，其距出入口（ ）。",[359,361,363,365],{"key":20,"text":360,"correct":22},"不应小于5.0m，且不应大于40.0m",{"key":24,"text":362,"correct":47},"不应小于15.0m，且不应大于40.0m",{"key":27,"text":364,"correct":47},"不应小于7.0m，且不应大于15.0m",{"key":30,"text":366,"correct":47},"不应小于15.0m，且不应大于60.0m",{"id":368,"libraryId":5,"type":131,"typeLabel":132,"stem":369,"options":370,"answer":24,"analysis":36},975188,"下列关于室外消火栓的安装说法错误的是（ ）。",[371,373,375,377],{"key":20,"text":372,"correct":47},"室外消火栓的选型、规格、数量和位置应符合设计要求",{"key":24,"text":374,"correct":22},"地下消火栓井的直径不宜小于1.2m",{"key":27,"text":376,"correct":47},"地下消火栓顶部进水口或顶部出水口应正对井口，顶部进水口或顶部出水口与消防井盖底面的距离不应大于0.4m",{"key":30,"text":378,"correct":47},"室外地上消火栓安装时，消火栓顶距地面高为0.64m，各接口应便于连接和操作",{"id":380,"libraryId":5,"type":131,"typeLabel":132,"stem":381,"options":382,"answer":30,"analysis":36},975189,"下列关于室内消火栓系统管网的布置说法错误的是（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":47},"当室外消火栓设计流量不大于10L\u002Fs，且室内消火栓不超过10个时，除国家有关规范规定的必须设置环状管网的情形外，可布置成枝状",{"key":24,"text":386,"correct":47},"室内消火栓竖管管径应根据竖管最低流量经计算确定，但不应小于DN100",{"key":27,"text":388,"correct":47},"室内管网应采用阀门划分若干个独立段，保证检修管道时关闭停用的竖管不超过1根",{"key":30,"text":390,"correct":22},"室内消火栓给水管网宜与自动喷水等其他水灭火系统的管网合用消防水泵时，供水管路应沿水流方向在报警阀后分开设置",{"id":392,"libraryId":5,"type":131,"typeLabel":132,"stem":393,"options":394,"answer":30,"analysis":36},975190,"送风口、排烟阀或排烟口的安装位置应符合国家标准和设计要求，并应固定牢靠，表面平整、不变形，调节灵活；排烟口距可燃物或可燃构件的距离不应小于（ ）。",[395,397,399,401],{"key":20,"text":396,"correct":47},"1.0m",{"key":24,"text":398,"correct":47},"1.2m",{"key":27,"text":400,"correct":47},"1.3m",{"key":30,"text":402,"correct":22},"1.5m",{"id":404,"libraryId":5,"type":131,"typeLabel":132,"stem":405,"options":406,"answer":30,"analysis":36},975191,"由两块或两块以上的挡烟垂帘组成的连续性挡烟垂壁各块之间不应有缝隙，搭接宽度不应小于（ ）。",[407,408,409,411],{"key":20,"text":248,"correct":47},{"key":24,"text":250,"correct":47},{"key":27,"text":410,"correct":47},"60mm",{"key":30,"text":412,"correct":22},"100mm",{"id":414,"libraryId":5,"type":131,"typeLabel":132,"stem":415,"options":416,"answer":27,"analysis":36},975192,"活动挡烟垂壁与建筑结构（柱或墙）面的缝隙不应大于（ ）。",[417,418,419,420],{"key":20,"text":248,"correct":47},{"key":24,"text":250,"correct":47},{"key":27,"text":410,"correct":22},{"key":30,"text":412,"correct":47},{"id":422,"libraryId":5,"type":131,"typeLabel":132,"stem":423,"options":424,"answer":27,"analysis":36},975193,"排烟窗手动开启机构或按钮应固定安装在距楼地面（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":47},"0.6-1.2m",{"key":24,"text":428,"correct":47},"1.1-1.3m",{"key":27,"text":430,"correct":22},"1.3-1.5m",{"key":30,"text":432,"correct":47},"1.5-1.8m",{"id":434,"libraryId":5,"type":131,"typeLabel":132,"stem":435,"options":436,"answer":27,"analysis":36},975194,"风口风速获取一般采用多点位测量取平均值的方法，测量时应根据风管横截面几何类型和面积大小，分别采用不同的测点布置方案。当风口面积小于0.3㎡时，可用（ ）个测点。",[437,438,439,441],{"key":20,"text":152,"correct":47},{"key":24,"text":154,"correct":47},{"key":27,"text":440,"correct":22},"5",{"key":30,"text":442,"correct":47},"6",{"id":444,"libraryId":5,"type":131,"typeLabel":132,"stem":445,"options":446,"answer":20,"analysis":36},975195,"风口风速获取一般采用多点位测量取平均值的方法，测量时应根据风管横截面几何类型和面积大小，分别采用不同的测点布置方案。对于圆形风罩，测点和测点间距分别取（ ）。",[447,449,451,453],{"key":20,"text":448,"correct":22},"5个；不大于200mm",{"key":24,"text":450,"correct":47},"6个；不大于100mm",{"key":27,"text":452,"correct":47},"5个；不大于100mm",{"key":30,"text":454,"correct":47},"6个；不大于200mm",{"id":456,"libraryId":5,"type":131,"typeLabel":132,"stem":457,"options":458,"answer":24,"analysis":36},975196,"送风口风速不宜大于（ ）。",[459,461,463,465],{"key":20,"text":460,"correct":47},"5m\u002Fs",{"key":24,"text":462,"correct":22},"7m\u002Fs",{"key":27,"text":464,"correct":47},"8m\u002Fs",{"key":30,"text":466,"correct":47},"10m\u002Fs",{"id":468,"libraryId":5,"type":131,"typeLabel":132,"stem":469,"options":470,"answer":30,"analysis":36},975197,"排烟口风速不宜大于（ ）。",[471,472,473,474],{"key":20,"text":460,"correct":47},{"key":24,"text":462,"correct":47},{"key":27,"text":464,"correct":47},{"key":30,"text":466,"correct":22},{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":489,"analysis":36},975198,"下列关于消防应急广播系统应与火灾声警报器分时交替工作的说法正确的是（ ）。",[479,481,483,485,487],{"key":20,"text":480,"correct":22},"可采取1次火灾声警报器播放、1次或2次消防应急广播播放的交替工作方式循环播放",{"key":24,"text":482,"correct":47},"消防应急广播的单次语音播放时间宜为8～20s",{"key":27,"text":484,"correct":47},"火灾声警报器单次发出火灾警报时间宜为10～30s",{"key":30,"text":486,"correct":22},"当确认火灾后，消防应急广播应同时向全楼进行广播",{"key":33,"text":488,"correct":22},"在消防控制室应能显示消防应急广播的广播分区的工作状态","ADE",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":504,"analysis":36},975199,"下列关于消防电梯的配置说法正确的是（ ）。",[494,496,498,500,502],{"key":20,"text":495,"correct":22},"消防电梯应能每层停靠",{"key":24,"text":497,"correct":47},"电梯的载重量不应小于600kg",{"key":27,"text":499,"correct":22},"电梯从首层至顶层的运行时间不宜大于60s",{"key":30,"text":501,"correct":22},"电梯轿厢的内部装修应采用不燃材料，梯轿厢内部应设置专用消防对讲电话",{"key":33,"text":503,"correct":22},"在首层的消防电梯入口处应设置供消防员专用的操作按钮","ACDE",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":519,"analysis":36},975200,"下列关于消防电梯安全设施的设置说法正确的是（ ）。",[509,511,513,515,517],{"key":20,"text":510,"correct":22},"消防电梯前室或合用前室应划分为单独探测区域，设火灾探测器和光警报器",{"key":24,"text":512,"correct":22},"除设置在仓库连廊、冷库穿堂或谷物筒仓工作塔内的消防电梯外，消防电梯应设置前室",{"key":27,"text":514,"correct":22},"消防电梯前室应设置室内消火栓",{"key":30,"text":516,"correct":47},"防电梯间前室或合用前室应设置排烟设施",{"key":33,"text":518,"correct":47},"除建筑高度小于27m的住宅建筑外，民用建筑、厂房和丙类仓库的消防电梯前室或合用前室应设置疏散照明，其地面水平最低照度不低于10.01x","ABC",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":534,"analysis":36},975201,"下列关于安全出口标志灯的安装符合规定的是（ ）。",[524,526,528,530,532],{"key":20,"text":525,"correct":22},"应安装在安全出口或疏散门内侧上方居中的位置",{"key":24,"text":527,"correct":47},"室内高度不大于3.5m的场所，标志灯底边离门框距离不应大于300mm",{"key":27,"text":529,"correct":22},"室内高度不大于3.5m的场所，采用吸顶或吊装式安装时，标志灯距安全出口或疏散门所在墙面的距离不宜大于50mm",{"key":30,"text":531,"correct":47},"室内高度大于3.5m的场所，特大型、大型、中型标志灯底边距地面高度不宜小于3m，且不宜大于5m",{"key":33,"text":533,"correct":22},"室内高度大于3.5m的场所，采用吸顶或吊装式安装时，标志灯距安全岀口或疏散门所在墙面的距离不宜大于50mm。","ACE",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":519,"analysis":36},975202,"下列关于方向标志灯的安装符合符合规范规定的是（ ）。",[539,541,543,545,547],{"key":20,"text":540,"correct":22},"应保证标志灯的箭头指示方向与疏散指示方案一致",{"key":24,"text":542,"correct":22},"安装在疏散走道、通道两侧的墙面或柱面上时，标志灯底边距地面的高度应小于1m",{"key":27,"text":544,"correct":22},"当安装在疏散走道、通道转角处的上方或两侧时，标志灯与转角处边墙的距离不应大于1m",{"key":30,"text":546,"correct":47},"当安全出口或疏散门在疏散走道侧边时，在疏散走道增设的方向标志灯应安装在疏散走道的两侧，且标志灯的标志面应与疏散方向垂直、箭头应指向安全出口或疏散门",{"key":33,"text":548,"correct":47},"安装在疏散走道、通道上方时，室内高度不大于3.5m的场所，标志灯底边距地面的高度宜为1.8m～2.2m",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":563,"analysis":36},975203,"下列关于建筑内疏散照明的地面最低水平照度的设置符合规范规定的是（ ）。",[553,555,557,559,561],{"key":20,"text":554,"correct":22},"疏散走道，不应低于1.0lx",{"key":24,"text":556,"correct":22},"消防控制室、消防水泵房、自备发电机房、配电室、防排烟机房以及发生火灾时仍需正常工作的消防设备房应设置备用照明，其作业面的最低照度不应低于正常照明的照度",{"key":27,"text":558,"correct":22},"楼梯间、前室或合用前室、避难走道，不应低于5.0lx",{"key":30,"text":560,"correct":47},"病房楼或手术部内的楼梯间、前室或合用前室、避难走道，不应低于5.0lx",{"key":33,"text":562,"correct":22},"老年人照料设施的楼梯间、前室或合用前室、避难走道，不应低于10.0lx","ABCE",[565,568,571,574,577,580],{"id":131,"name":566,"category":7,"favorite":567},"领导干部任职前廉政法规知识测试题",92,{"id":569,"name":570,"category":7,"favorite":131},595,"建筑结构与设备",{"id":572,"name":573,"category":7,"favorite":131},715,"招标采购专业知识与法律法规",{"id":575,"name":576,"category":7,"favorite":131},848,"市政方向-通用基础",{"id":578,"name":579,"category":7,"favorite":8},534,"BIM工程师",{"id":581,"name":579,"category":7,"favorite":8},535]