[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-44":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":515},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,44,50,2486,[13,28,34,40,46,62,74,86,98,109,121,133,143,151,169,184,199,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,319,331,343,355,367,379,387,399,409,420,430,442,454,462,474,489,500],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},975102,3,"判断题","设置消防联动控制器的火灾自动报警系统，火灾声光警报器应由火灾报警控制器或消防联动控制器控制。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},975103,"火灾报警控制器或消防联动控制器处于“自动”状态，触发同一楼层的两个不同探测形式的报警触发装置，核查所有电梯迫降情况。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},975104,"常用的接地电阻测量仪器主要有两种：手摇式接地电阻测试仪和钳形接地电阻测试仪",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},975105,"火灾自动报警系统接地装置的接地电阻值应符合下列规定：采用共用接地装置时，接地电阻值不应大于4Ω；采用专用接地装置时，接地电阻值不应大于1Ω。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":48,"typeLabel":49,"stem":50,"options":51,"answer":20,"analysis":27},975106,1,"单选题","点型火灾探测器距墙壁、梁边及遮挡物不应小于（ ）m。",[52,54,56,59],{"key":20,"text":53,"correct":22},"0.5",{"key":24,"text":55,"correct":26},"1.5",{"key":57,"text":58,"correct":26},"C","2.5",{"key":60,"text":61,"correct":26},"D","3.5",{"id":63,"libraryId":5,"type":48,"typeLabel":49,"stem":64,"options":65,"answer":20,"analysis":27},975107,"下列关于收到报警按钮的安装说法正确的是（ ）。",[66,68,70,72],{"key":20,"text":67,"correct":22},"每个防火分区应至少设置一只，应设在明显和便于操作的部位",{"key":24,"text":69,"correct":26},"从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离不应大于25m",{"key":57,"text":71,"correct":26},"手动火灾报警按钮宜设置在疏散通道或出入口处",{"key":60,"text":73,"correct":26},"当采用壁挂方式安装时，其底边距地高度宜为1.3-1.5m，且应有明显标识",{"id":75,"libraryId":5,"type":48,"typeLabel":49,"stem":76,"options":77,"answer":24,"analysis":27},975108,"当水流指示器入口前设置控制阀时，应采用信号阀，两者之间的距离不宜小于（ ）。",[78,80,82,84],{"key":20,"text":79,"correct":26},"100mm",{"key":24,"text":81,"correct":22},"300mm",{"key":57,"text":83,"correct":26},"500mm",{"key":60,"text":85,"correct":26},"800mm",{"id":87,"libraryId":5,"type":48,"typeLabel":49,"stem":88,"options":89,"answer":20,"analysis":27},975109,"下列关于干式系统的设置说法不正确的是（ ）。",[90,92,94,96],{"key":20,"text":91,"correct":22},"干式系统充气连接管接口应在报警阀气室充注水位以上部位，且充气连接管的直径不应小于25mm",{"key":24,"text":93,"correct":26},"止回阀、截止阀应安装在充气连接管上",{"key":57,"text":95,"correct":26},"低气压预报警装置应安装在配水干管一侧",{"key":60,"text":97,"correct":26},"空气压缩机的气泵和储气罐、加速器上应安装压力表",{"id":99,"libraryId":5,"type":48,"typeLabel":49,"stem":100,"options":101,"answer":24,"analysis":27},975110,"末端试水装置的出水，应采取孔口出流的方式排入排水管道，排水立管宜设伸顶通气管，且管径不应小于（ ）。",[102,103,105,107],{"key":20,"text":79,"correct":26},{"key":24,"text":104,"correct":22},"75mm",{"key":57,"text":106,"correct":26},"50mm",{"key":60,"text":108,"correct":26},"25mm",{"id":110,"libraryId":5,"type":48,"typeLabel":49,"stem":111,"options":112,"answer":24,"analysis":27},975111,"湿式自动喷水灭火系统打开警铃试验阀，同时按下秒表开始计时，待警铃响起时，停止秒表，通过秒表显示核查延迟时间。水力警铃应在（ ）内发出报警铃声。",[113,115,117,119],{"key":20,"text":114,"correct":26},"2～90s",{"key":24,"text":116,"correct":22},"5～90s",{"key":57,"text":118,"correct":26},"5～30s",{"key":60,"text":120,"correct":26},"5～60s",{"id":122,"libraryId":5,"type":48,"typeLabel":49,"stem":123,"options":124,"answer":57,"analysis":27},975112,"对于干式报警阀组，在开启警铃试验阀前，应首先关闭报警管路控制阀。测试完成后，关闭警铃试验阀并打开报警管路排水阀，余水排出后关闭排水阀，打开报警管路控制阀。干式报警阀组水力警铃应在（ ）s内发出报警铃声。",[125,127,129,131],{"key":20,"text":126,"correct":26},"5",{"key":24,"text":128,"correct":26},"10",{"key":57,"text":130,"correct":22},"15",{"key":60,"text":132,"correct":26},"30",{"id":134,"libraryId":5,"type":48,"typeLabel":49,"stem":135,"options":136,"answer":57,"analysis":27},975113,"湿式自动喷水灭火系统开启末端试水装置后（ ）min内应自动启动消防水泵。",[137,139,141,142],{"key":20,"text":138,"correct":26},"1",{"key":24,"text":140,"correct":26},"3",{"key":57,"text":126,"correct":22},{"key":60,"text":128,"correct":26},{"id":144,"libraryId":5,"type":48,"typeLabel":49,"stem":145,"options":146,"answer":20,"analysis":27},975114,"干式自动喷水灭火系统测试时，还应测试配水管道充水时间，应不大于（ ）min。",[147,148,149,150],{"key":20,"text":138,"correct":22},{"key":24,"text":140,"correct":26},{"key":57,"text":126,"correct":26},{"key":60,"text":128,"correct":26},{"id":152,"libraryId":5,"type":153,"typeLabel":154,"stem":155,"options":156,"answer":168,"analysis":27},975115,2,"多选题","下列关于报警阀组的安装说法正确的有（ ）。",[157,159,161,163,165],{"key":20,"text":158,"correct":22},"报警阀距地面的高度为1.2m",{"key":24,"text":160,"correct":26},"报警阀两侧与墙的距离为300mm",{"key":57,"text":162,"correct":26},"报警阀正面与墙的距离为1.0m",{"key":60,"text":164,"correct":22},"报警阀组凸出部位之间的距离为800mm",{"key":166,"text":167,"correct":22},"E","设置报警阀组的部位应设有排水设施","ADE",{"id":170,"libraryId":5,"type":153,"typeLabel":154,"stem":171,"options":172,"answer":183,"analysis":27},975116,"下列关于湿式系统洒水喷头的设置说法正确的是（ ）。",[173,175,177,179,181],{"key":20,"text":174,"correct":22},"不做吊顶的场所，当配水支管布置在梁下时，应采用直立型洒水喷头",{"key":24,"text":176,"correct":22},"吊顶下布置的洒水喷头，应采用下垂型洒水喷头或吊顶型洒水喷头",{"key":57,"text":178,"correct":26},"顶板为水平面的中危险级Ⅱ级旅馆建筑客房可采用边墙型洒水喷头",{"key":60,"text":180,"correct":22},"顶板为水平面，且无梁、通风管道等障碍物影响喷头洒水的场所，可采用扩大覆盖面积洒水喷头",{"key":166,"text":182,"correct":22},"中危险级Ⅰ级场所可选用隐蔽式洒水喷头","ABDE",{"id":185,"libraryId":5,"type":153,"typeLabel":154,"stem":186,"options":187,"answer":198,"analysis":27},975117,"下列关于报警阀组的设置说法不正确的有（ ）。",[188,190,192,194,196],{"key":20,"text":189,"correct":22},"湿式系统一个报警阀组控制的洒水喷头数不宜超过500只",{"key":24,"text":191,"correct":22},"其他系统接入湿式系统时，应分别设置独立的报警阀组，其控制的洒水喷头数可不计入湿式报警阀组控制的洒水喷头总数",{"key":57,"text":193,"correct":26},"每个报警阀组供水的最高与最低位置洒水喷头，其高程差不宜大于50m",{"key":60,"text":195,"correct":26},"置报警阀组的部位应设有排水设施，排水能力应满足报警阀调试、验收和利用试水阀门泄空系统管道的要求",{"key":166,"text":197,"correct":26},"连接报警阀进出口的控制阀应采用信号阀","AB",{"id":200,"libraryId":5,"type":153,"typeLabel":154,"stem":201,"options":202,"answer":213,"analysis":27},975118,"下列关于水流指示器的设置说法不正确的有（ ）。",[203,205,207,209,211],{"key":20,"text":204,"correct":22},"每个防火分区、每个楼层均应设水流指示器",{"key":24,"text":206,"correct":26},"仓库内顶板下洒水喷头与货架内置洒水喷头应分别设置水流指示器",{"key":57,"text":208,"correct":22},"当水流指示器入口前设置控制阀时，应采用信号阀，两者之间的距离不宜小于500mm",{"key":60,"text":210,"correct":26},"水流指示器应使电器元件部位竖直安装在水平管道上侧，其动作方向应和水流方向一致",{"key":166,"text":212,"correct":26},"水流指示器的引出线应用防水套管锁定","AC",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":21,"analysis":27},975119,"报警阀后的管道上不应安装其他用途的支管、水龙头。如不同系统合用消防水泵时，应在报警阀前分开设置。",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},975120,"管道横向安装坡度为0.003-0.005，且坡向排水管；相应的排水措施设置符合规定要求",[224,225],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":27},975121,"公称直径大于或等于100mm的管道其距离顶板、墙面的安装距离不宜小于100mm。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},975122,"穿过卫生间或厨房楼板的套管，其顶部应高岀装饰地面20mm，且套管底部应与楼板底面相平。",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},975123,"穿过墙体或楼板时应加设套管，套管长度不得小于墙体厚度，穿过楼板的套管其顶部应高出装饰地面50mm.",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},975124,"配水干管、配水管应做红色或红色环圈标识。红色环圈标识宽度为50mm，间隔3m，在一个独立的单元内环圈标识不宜少于2处。",[248,249],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":27},975125,"水力警铃与报警阀连接的管道，其管径应为20mm，总长不宜大于25m。",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":25,"analysis":27},975126,"干式系统充气连接管接口应在报警阀气室充注水位以上部位，且充气连接管的直径不应小于25mm。",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},975127,"除报警阀组控制的洒水喷头只保护不超过防火分区面积的同层场所外，每个防火分区、每个楼层均应设水流指示器。",[266,267],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},975128,"仓库内顶板下洒水喷头与货架内置洒水喷头应分别设置水流指示器。",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":21,"analysis":27},975129,"当水流指示器入口前设置控制阀时，应采用信号阀，两者之间的距离为500mm。",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},975130,"湿式、干式自动喷水灭火系统应由消防水泵出水干管上设置的压力开关、高位消防水箱出水管上的流量开关、消火栓按钮和报警阀组压力开关直接自动启动消防水泵。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":27},975131,"湿式报警阀警铃试验阀测试，打开警铃试验阀，同时按下秒表开始计时，待警铃响起时，停止秒表，通过秒表显示核查延迟时间。水力警铃应在2-90s内发出报警铃声。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},975132,"使用声级计测量，距水力警铃3m远处警铃声压级不应小于75dB。",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},975133,"缓慢打开末端试水装置控制阀至全开，观察试水接头处水流情况，观察压力表变化情况，记录压力表稳定读数。末端试水装置处的出水压力不应低于0.05MPa。",[302,303],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":305,"libraryId":5,"type":153,"typeLabel":154,"stem":306,"options":307,"answer":318,"analysis":27},975134,"下列关于水力警铃的设置说法正确的是（ ）。",[308,310,312,314,316],{"key":20,"text":309,"correct":26},"水力警铃的工作压力不应大于0.05MPa",{"key":24,"text":311,"correct":22},"应设在有人值班的地点附近或公共通道的外墙上",{"key":57,"text":313,"correct":22},"安装后的水力警铃启动时，警铃声压级应不小于70dB",{"key":60,"text":315,"correct":26},"出水管报警阀组凸出部位之间的距离为300mm",{"key":166,"text":317,"correct":22},"应安装检修、测试用的阀门","BCE",{"id":320,"libraryId":5,"type":48,"typeLabel":49,"stem":321,"options":322,"answer":20,"analysis":27},975135,"使用声级计测量，距水力警铃（ ）远处警铃声压级不应小于（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"3m；70dB",{"key":24,"text":326,"correct":26},"3m；75dB",{"key":57,"text":328,"correct":26},"5m；70dB",{"key":60,"text":330,"correct":26},"5m；75dB",{"id":332,"libraryId":5,"type":48,"typeLabel":49,"stem":333,"options":334,"answer":60,"analysis":27},975136,"下列关于消防管网的安装说法正确的是（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":26},"不同系统合用消防水泵时，应在报警阀后分开设置",{"key":24,"text":338,"correct":26},"管道横向安装坡度为0.002～0.005，且坡向排水管",{"key":57,"text":340,"correct":26},"公称直径大于或等于100mm的管道其距离顶板、墙面的安装距离不宜小于150mm",{"key":60,"text":342,"correct":22},"穿过墙体或楼板时应加设套管，套管长度不得小于墙体厚度，穿过楼板的套管其顶部应高出装饰地面20mm",{"id":344,"libraryId":5,"type":48,"typeLabel":49,"stem":345,"options":346,"answer":20,"analysis":27},975137,"配水干管、配水管应做红色或红色环圈标识。红色环圈标识宽度不应小于（ ），间隔不宜大于（ ），在一个独立的单元内环圈标识不宜少于2处。",[347,349,351,353],{"key":20,"text":348,"correct":22},"20mm；4m",{"key":24,"text":350,"correct":26},"50mm；3m",{"key":57,"text":352,"correct":26},"20mm；3m",{"key":60,"text":354,"correct":26},"50mm；4m",{"id":356,"libraryId":5,"type":48,"typeLabel":49,"stem":357,"options":358,"answer":57,"analysis":27},975139,"下列关于喷头的选用说法正确的是（ ）。",[359,361,363,365],{"key":20,"text":360,"correct":26},"干式系统应采用下垂型洒水喷头",{"key":24,"text":362,"correct":26},"同一隔间内根据位置不用选择热敏性能的洒水喷头",{"key":57,"text":364,"correct":22},"安装在易受机械损伤处的喷头，应加设喷头防护罩",{"key":60,"text":366,"correct":26},"应有备用洒水喷头，其数量不应少于总数的10%，且每种型号均不得少于10只",{"id":368,"libraryId":5,"type":48,"typeLabel":49,"stem":369,"options":370,"answer":57,"analysis":27},975140,"湿式系统一个报警阀组控制的洒水喷头数不宜超过（ ）只。",[371,373,375,377],{"key":20,"text":372,"correct":26},"300",{"key":24,"text":374,"correct":26},"500",{"key":57,"text":376,"correct":22},"800",{"key":60,"text":378,"correct":26},"1000",{"id":380,"libraryId":5,"type":48,"typeLabel":49,"stem":381,"options":382,"answer":24,"analysis":27},975141,"干式系统一个报警阀组控制的洒水喷头数不宜超过（ ）只。",[383,384,385,386],{"key":20,"text":372,"correct":26},{"key":24,"text":374,"correct":22},{"key":57,"text":376,"correct":26},{"key":60,"text":378,"correct":26},{"id":388,"libraryId":5,"type":48,"typeLabel":49,"stem":389,"options":390,"answer":24,"analysis":27},975142,"每个报警阀组供水的最高与最低位置洒水喷头，其高程差不宜大于（ ）。",[391,393,395,397],{"key":20,"text":392,"correct":26},"30m",{"key":24,"text":394,"correct":22},"50m",{"key":57,"text":396,"correct":26},"80m",{"key":60,"text":398,"correct":26},"100m",{"id":400,"libraryId":5,"type":48,"typeLabel":49,"stem":401,"options":402,"answer":24,"analysis":27},975143,"报警阀组应安装在便于操作的明显位置，距室内地面高度宜为1.2m；两侧与墙的距离不应小于0.5m；正面与墙的距离不应小于（ ）m。",[403,404,406,407],{"key":20,"text":138,"correct":26},{"key":24,"text":405,"correct":22},"1.2",{"key":57,"text":55,"correct":26},{"key":60,"text":408,"correct":26},"2",{"id":410,"libraryId":5,"type":48,"typeLabel":49,"stem":411,"options":412,"answer":20,"analysis":27},975144,"水力警铃应安装在公共通道或值班室附近的外墙上，当镀锌钢管的公称直径为20mm时，其长度不宜大于（ ）m。",[413,415,417,418],{"key":20,"text":414,"correct":22},"20",{"key":24,"text":416,"correct":26},"25",{"key":57,"text":132,"correct":26},{"key":60,"text":419,"correct":26},"35",{"id":421,"libraryId":5,"type":48,"typeLabel":49,"stem":422,"options":423,"answer":24,"analysis":27},975145,"每个报警阀组控制的最不利点喷头处，应设置末端试水装置，其他防火分区、楼层均应设直径为（ ）mm的试水阀或末端试水装置。",[424,425,426,428],{"key":20,"text":128,"correct":26},{"key":24,"text":416,"correct":22},{"key":57,"text":427,"correct":26},"40",{"key":60,"text":429,"correct":26},"50",{"id":431,"libraryId":5,"type":48,"typeLabel":49,"stem":432,"options":433,"answer":60,"analysis":27},975146,"不能直接自动启动湿式、干式自动喷水灭火系统的消防水泵的是（ ）。",[434,436,438,440],{"key":20,"text":435,"correct":26},"消防水泵出水干管上设置的压力开关",{"key":24,"text":437,"correct":26},"高位消防水箱出水管上的流量开关",{"key":57,"text":439,"correct":26},"报警阀组压力开关",{"key":60,"text":441,"correct":22},"消火栓按钮",{"id":443,"libraryId":5,"type":48,"typeLabel":49,"stem":444,"options":445,"answer":24,"analysis":27},975147,"湿式、干式自动喷水灭火系统连锁（ ）不受消防联动控制器处于自动或手动状态影响。",[446,448,450,452],{"key":20,"text":447,"correct":26},"联动控制",{"key":24,"text":449,"correct":22},"连锁控制",{"key":57,"text":451,"correct":26},"电动控制",{"key":60,"text":453,"correct":26},"远程控制",{"id":455,"libraryId":5,"type":48,"typeLabel":49,"stem":456,"options":457,"answer":20,"analysis":27},975148,"受消防联动控制器处于自动或手动状态影响的是（ ）方式。",[458,459,460,461],{"key":20,"text":447,"correct":22},{"key":24,"text":449,"correct":26},{"key":57,"text":451,"correct":26},{"key":60,"text":453,"correct":26},{"id":463,"libraryId":5,"type":48,"typeLabel":49,"stem":464,"options":465,"answer":60,"analysis":27},975149,"对于湿式、干式自动喷水灭火系统，消防联动控制器在收到（ ）信号后不能发出启泵信号。",[466,468,470,472],{"key":20,"text":467,"correct":26},"报警阀组压力开关发出的反馈信号和该报警阀防护区内任一感烟火灾探测器的信号",{"key":24,"text":469,"correct":26},"报警阀组压力开关发出的反馈信号和该报警阀防护区内任一感温火灾探测器的信号",{"key":57,"text":471,"correct":26},"报警阀组压力开关发出的反馈信号和该报警阀防护区内手动火灾报警按钮的信号",{"key":60,"text":473,"correct":22},"该报警阀防护区内两个独立的火灾报警信号",{"id":475,"libraryId":5,"type":153,"typeLabel":154,"stem":476,"options":477,"answer":488,"analysis":27},975150,"下列关于末端试水装置的设置说法正确的是（ ）。",[478,480,482,484,486],{"key":20,"text":479,"correct":26},"每个报警阀组控制的每个楼层应设末端试水装置，其他防火分区、楼层均应设直径为25mm的试水阀",{"key":24,"text":481,"correct":22},"末端试水装置应由试水阀、压力表以及试水接头组成",{"key":57,"text":483,"correct":22},"试水接头出水口的流量系数，应等同于同楼层或防火分区内的最小流量系数",{"key":60,"text":485,"correct":22},"末端试水装置的出水，应采取孔口出流的方式排入排水管道，排水立管宜设伸顶通气管，且管径不应小于75mm",{"key":166,"text":487,"correct":26},"末端试水装置和试水阀应有标识，其安装位置应便于检查、试验，距地面的高度宜为1.3m，并应采取不被他用的措施","BCD",{"id":490,"libraryId":5,"type":153,"typeLabel":154,"stem":491,"options":492,"answer":499,"analysis":27},975151,"湿式、干式自动喷水灭火系统应由（ ）直接自动启动消防水泵。",[493,494,495,496,497],{"key":20,"text":435,"correct":22},{"key":24,"text":437,"correct":22},{"key":57,"text":439,"correct":22},{"key":60,"text":441,"correct":26},{"key":166,"text":498,"correct":26},"手动报警按钮","ABC",{"id":501,"libraryId":5,"type":153,"typeLabel":154,"stem":502,"options":503,"answer":514,"analysis":27},975152,"湿式、干式自动喷水灭火系统联动控制要求正确的是（ ）。",[504,506,508,510,512],{"key":20,"text":505,"correct":22},"需要火灾自动报警系统联动控制的消防设备，其联动触发信号应采用两个独立的报警触发装置报警信号的“与”逻辑组合",{"key":24,"text":507,"correct":22},"消防联动控制器收到报警阀组压力开关发出的反馈信号",{"key":57,"text":509,"correct":22},"且消防联动控制器收到该报警阀防护区内任一火灾探测器或手动火灾报警按钮的信号",{"key":60,"text":511,"correct":26},"联动控制方式不受消防联动控制器处于自动或手动状态影响",{"key":166,"text":513,"correct":22},"联动控制不应影响连锁控制的功能","ABCE",[516,519,522,525,528,531],{"id":48,"name":517,"category":7,"favorite":518},"领导干部任职前廉政法规知识测试题",92,{"id":520,"name":521,"category":7,"favorite":48},595,"建筑结构与设备",{"id":523,"name":524,"category":7,"favorite":48},715,"招标采购专业知识与法律法规",{"id":526,"name":527,"category":7,"favorite":48},848,"市政方向-通用基础",{"id":529,"name":530,"category":7,"favorite":8},534,"BIM工程师",{"id":532,"name":530,"category":7,"favorite":8},535]