[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-43":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":464},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,43,50,2486,[13,34,46,58,76,86,92,98,104,110,116,122,128,134,140,146,152,158,164,170,182,188,194,200,206,218,230,242,254,266,277,289,301,313,325,339,354,369,384,399,405,410,416,422,428,434,440,446,452,458],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},975052,1,"单选题","当确认火灾后，由发生火灾的报警区域开始，顺序启动全楼疏散通道的消防应急照明和疏散指示系统，系统全部投入应急状态的启动时间（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","不应大于1s",false,{"key":24,"text":25,"correct":22},"B","不应大于1.5s",{"key":27,"text":28,"correct":22},"C","不应大于3s",{"key":30,"text":31,"correct":32},"D","不应大于5s",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},975053,"当火灾报警控制器和消防联动控制器安装在墙上时，下列说法正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":32},"其主显示屏高度为1.6m",{"key":24,"text":41,"correct":22},"其主显示屏高度宜为1.3m",{"key":27,"text":43,"correct":22},"靠近门轴的侧面距墙为1.0m",{"key":30,"text":45,"correct":22},"正面操作距离为0.8m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},975054,"火灾自动报警系统接地装置采用共用接地装置时，接地电阻值不应大于（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":32},"1Ω",{"key":24,"text":53,"correct":22},"2Ω",{"key":27,"text":55,"correct":22},"4Ω",{"key":30,"text":57,"correct":22},"5Ω",{"id":59,"libraryId":5,"type":60,"typeLabel":61,"stem":62,"options":63,"answer":75,"analysis":33},975055,2,"多选题","下列关于火灾报警控制器和消防联动控制器的设置和安装要求说法正确的有（ ）。",[64,66,68,70,72],{"key":20,"text":65,"correct":22},"火灾显示器在墙上安装时，其主显示屏高度为1.3m",{"key":24,"text":67,"correct":22},"控制器类设备落地安装时，其底边高岀地（楼）面0.5m",{"key":27,"text":69,"correct":32},"控制器类设备在墙上安装时，正面操作距离不应小于1.2m",{"key":30,"text":71,"correct":32},"控制器应安装牢固，不应倾斜",{"key":73,"text":74,"correct":32},"E","控制器的主电源应有明显的永久性标识，并应直接与消防电源连接，严禁使用电源插头","CDE",{"id":77,"libraryId":5,"type":78,"typeLabel":79,"stem":80,"options":81,"answer":83,"analysis":33},975056,3,"判断题","火灾自动报警系统一般由火灾探测报警系统、消防联动控制系统、可燃气体探测报警系统和电气火灾监控系统等全部或部分构成。",[82,84],{"key":20,"text":83,"correct":32},"正确",{"key":24,"text":85,"correct":22},"错误",{"id":87,"libraryId":5,"type":78,"typeLabel":79,"stem":88,"options":89,"answer":85,"analysis":33},975057,"火灾报警控制器、火灾显示器、消防联动控制器等控制器类设备在墙上安装时，其主显示屏高度宜为1.8～2.2m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于1.2m。",[90,91],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":93,"libraryId":5,"type":78,"typeLabel":79,"stem":94,"options":95,"answer":85,"analysis":33},975058,"火灾报警控制器、火灾显示器、消防联动控制器等控制器类设备落地安装时，其底边宜高岀地（楼）面0.5m。",[96,97],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":99,"libraryId":5,"type":78,"typeLabel":79,"stem":100,"options":101,"answer":85,"analysis":33},975059,"控制器的主电源应有明显的永久性标识，使用电源插头与消防电源连接。控制器与其外接备用电源之间应直接连接。",[102,103],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":105,"libraryId":5,"type":78,"typeLabel":79,"stem":106,"options":107,"answer":83,"analysis":33},975060,"点型火灾探测器在宽度为3m的内走道顶棚上宜居中布置，感温火灾探测器的安装间距不应超过10m，探测器至端墙的距离不应大于探测器安装间距的1\u002F2。",[108,109],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":111,"libraryId":5,"type":78,"typeLabel":79,"stem":112,"options":113,"answer":85,"analysis":33},975061,"点型火灾探测器在宽度大于3m的内走道顶棚上宜居中布置，感烟火灾探测器的安装间距不应超过15m，探测器至端墙的距离不应大于探测器安装间距的1\u002F2。",[114,115],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":117,"libraryId":5,"type":78,"typeLabel":79,"stem":118,"options":119,"answer":85,"analysis":33},975062,"点型火灾探测器距墙壁、梁边及遮挡物不应小于0.5m，距空调送风口最近边的水平距离不应小于1.0m。",[120,121],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":123,"libraryId":5,"type":78,"typeLabel":79,"stem":124,"options":125,"answer":83,"analysis":33},975063,"每个报警区域内的模块宜相对集中设置在本报警区域内的金属模块箱中。模块（或金属箱）应独立支撑或固定，安装牢固，并应采取防潮、防腐蚀等措施。",[126,127],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":129,"libraryId":5,"type":78,"typeLabel":79,"stem":130,"options":131,"answer":83,"analysis":33},975064,"按照《建筑消防设施的维护管理》（GB25201）的规定，投入运行的火灾自动报警系统各组件进行检测，火灾警报器，试验警报功能。",[132,133],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":135,"libraryId":5,"type":78,"typeLabel":79,"stem":136,"options":137,"answer":85,"analysis":33},975065,"触发同一建筑内两只独立的火灾探测器，启动需测试的火灾警报装置，进行火灾探测报警装置功能测试。",[138,139],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":141,"libraryId":5,"type":78,"typeLabel":79,"stem":142,"options":143,"answer":83,"analysis":33},975066,"触发同一报警区域内一只火灾探测器与一只手动火灾报警按钮，启动需测试的火灾警报装置，进行火灾探测报警装置功能测试。",[144,145],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":147,"libraryId":5,"type":78,"typeLabel":79,"stem":148,"options":149,"answer":85,"analysis":33},975067,"火灾警报装置启动后，使用声级计测量其声信号至少在一个方向上3m处的声压级应不小于75dB（A计权），具有光警报功能的，光信号在100～500lx环境光线下，30m处应清晰可见。",[150,151],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":153,"libraryId":5,"type":78,"typeLabel":79,"stem":154,"options":155,"answer":83,"analysis":33},975068,"火灾报警控制器和消防联动控制器，应设置在消防控制室内或有人值班的房间和场所。",[156,157],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":159,"libraryId":5,"type":78,"typeLabel":79,"stem":160,"options":161,"answer":85,"analysis":33},975069,"火灾报警控制器和消防联动控制器安装在墙上时，其主显示屏高度宜为1.5-1.8m，其靠近门轴的侧面距墙不应小于0.5m，正面操作距离不应小于1.5m。",[162,163],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":165,"libraryId":5,"type":78,"typeLabel":79,"stem":166,"options":167,"answer":83,"analysis":33},975070,"消防应急广播系统的联动控制信号应由消防联动控制器发岀。当确认火灾后，应同时向全楼进行广播。",[168,169],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":27,"analysis":33},975071,"在宽度小于3m的内走道顶棚上安装探测器时，宜居中安装。感烟火灾探测器的安装间距不应超过（ ）m。",[174,176,178,180],{"key":20,"text":175,"correct":22},"5",{"key":24,"text":177,"correct":22},"10",{"key":27,"text":179,"correct":32},"15",{"key":30,"text":181,"correct":22},"20",{"id":183,"libraryId":5,"type":78,"typeLabel":79,"stem":184,"options":185,"answer":85,"analysis":33},975072,"集中电源非集中控制型消防应急照明和疏散指示系统，应由消防联动控制器联动消防应急照明配电箱实现。",[186,187],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":189,"libraryId":5,"type":78,"typeLabel":79,"stem":190,"options":191,"answer":85,"analysis":33},975073,"消防联动控制器应具有切断整个建筑的非消防电源的功能。",[192,193],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":195,"libraryId":5,"type":78,"typeLabel":79,"stem":196,"options":197,"answer":83,"analysis":33},975074,"消防联动控制器应具有打开疏散通道上由门禁系统控制的门和庭院电动大门的功能，并应具有打开停车场出入口挡杆的功能。",[198,199],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":201,"libraryId":5,"type":78,"typeLabel":79,"stem":202,"options":203,"answer":85,"analysis":33},975075,"火灾报警控制器或消防联动控制器处于“自动”状态，触发同一防烟分区的两个不同探测形式的报警触发装置，核查建筑内所有疏散通道的消防应急照明和疏散指示系统启动情况，测量系统全部投入应急状态的启动时间。",[204,205],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":30,"analysis":33},975076,"下列关于火灾警报器的设置和安装要求说法不正确的是（ ）。",[210,212,214,216],{"key":20,"text":211,"correct":22},"火灾警报器应设置在每个楼层的楼梯口、消防电梯前室、建筑内部拐角等处的明显部位，且不宜与安全出口指示标志灯具设置在同一面墙上",{"key":24,"text":213,"correct":22},"每个报警区域内应均匀设置火灾警报器，其声压级不应小于60dB",{"key":27,"text":215,"correct":22},"在环境噪声大于60dB的场所，其声压级应高于背景噪声15dB",{"key":30,"text":217,"correct":32},"当火灾警报器采用壁挂方式安装时，底边距地面高度不应小于2.2m",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":27,"analysis":33},975077,"火灾警报装置启动后，使用声级计测量其声信号至少在一个方向上3m处的声压级应不小于（ ）（A计权），具有光警报功能的，光信号在100～500lx环境光线下，25m处应清晰可见。",[222,224,226,228],{"key":20,"text":223,"correct":22},"60dB",{"key":24,"text":225,"correct":22},"70dB",{"key":27,"text":227,"correct":32},"75dB",{"key":30,"text":229,"correct":22},"85dB",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":27,"analysis":33},975078,"下列关于火灾报警控制器和消防联动控制器的设置和安装要求,说法不正确的是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":22},"消防联动控制器等控制器类设备（以下称控制器）在墙上安装时，其主显示屏高度宜为1.5～1.8m",{"key":24,"text":237,"correct":22},"消防联动控制器等控制器类设备（以下称控制器）在墙上安装时，其靠近门轴的侧面距墙不应小于0.5m",{"key":27,"text":239,"correct":32},"控制器前的正面操作距离不应小于2m",{"key":30,"text":241,"correct":22},"消防联动控制器落地安装时，其底边高岀地（楼）面0.5m",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":24,"analysis":33},975079,"点型火灾探测器距空调送风口最近边的水平距离不应小于（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":22},"2.0m",{"key":24,"text":249,"correct":32},"1.5m",{"key":27,"text":251,"correct":22},"1.0m",{"key":30,"text":253,"correct":22},"0.5m",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":24,"analysis":33},975080,"下列关于火灾探测器的设置说法不正确的是（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"点型火灾探测器的确认灯应面向便于人员核查的主要入口方向",{"key":24,"text":261,"correct":32},"当梁突出顶棚的高度超过1.0m时，被梁隔断的每个梁间区域应至少设置一只探测器",{"key":27,"text":263,"correct":22},"线型感温火灾探测器在保护电缆、堆垛等类似保护对象时，应采用接触式布置",{"key":30,"text":265,"correct":22},"火灾探测器宜水平安装，当确需倾斜安装时，倾斜角不应大于45°。",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":20,"analysis":33},975081,"在顶棚下方的线型差温火灾探测器至顶棚距离宜为（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":32},"0.1m",{"key":24,"text":273,"correct":22},"0.2m",{"key":27,"text":275,"correct":22},"0.3m",{"key":30,"text":253,"correct":22},{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":33},975082,"下列关于消防联动控制器控制不同设置位置的防火卷帘下降的说法正确的是（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"疏散通道上设置的防火卷帘下降至距顶板面1.8m处",{"key":24,"text":284,"correct":32},"非疏散通道上设置的防火卷帘下降到楼板面",{"key":27,"text":286,"correct":22},"疏散通道上设置的防火卷帘下降到楼板面",{"key":30,"text":288,"correct":22},"非疏散通道上设置的防火卷帘下降至距楼板面1.8m处",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":20,"analysis":33},975083,"消防应急广播系统的联动控制信号应由消防联动控制器发岀。当确认火灾后，（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":32},"应同时向全楼进行广播",{"key":24,"text":296,"correct":22},"应同时向该层进行广播",{"key":27,"text":298,"correct":22},"应同时向该层及以上楼层进行广播",{"key":30,"text":300,"correct":22},"应同时向该层及以下楼层进行广播域",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":30,"analysis":33},975084,"下列关于消防应急照明和疏散指示系统的联动控制说法不正确的是（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"集中控制型消防应急照明和疏散指示系统，应由火灾报警控制器或消防联动控制器启动应急照明控制器实现",{"key":24,"text":308,"correct":22},"集中电源非集中控制型消防应急照明和疏散指示系统，应由消防联动控制器联动消防应急照明集中电源和消防应急照明分配电装置实现",{"key":27,"text":310,"correct":22},"自带电源非集中控制型消防应急照明和疏散指示系统，应由消防联动控制器联动消防应急照明配电箱实现",{"key":30,"text":312,"correct":32},"自带电源非集中控制型消防应急照明和疏散指示系统，应由消防联动控制器联动消防应急照明集中电源和消防应急照明分配电装置实现",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},975085,"下列关于消防联动控制器功能的描述错误的是（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":22},"消防联动控制器应具有启动消火栓泵的功能",{"key":24,"text":320,"correct":32},"消防联动控制器应具有切断全楼的非消防电源的功能",{"key":27,"text":322,"correct":22},"消防联动控制器应具有自动打开涉及疏散的电动栅杆等的功能",{"key":30,"text":324,"correct":22},"消防联动控制器应具有打开疏散通道上由门禁系统控制的门和庭院电动大门的功能，并应具有打开停车场出入口挡杆的功能",{"id":326,"libraryId":5,"type":60,"typeLabel":61,"stem":327,"options":328,"answer":338,"analysis":33},975086,"下列关于火灾探测器的设置和安装要求说法正确的是（ ）。",[329,331,333,335,337],{"key":20,"text":330,"correct":32},"点型火灾探测器在探测区域内每区域至少应设置一只，保护面积与半径应符合要求",{"key":24,"text":332,"correct":22},"点型火灾探测器在宽度小于3m的内走道顶棚上宜居中布置，感温火灾探测器的安装间距不应超过15m",{"key":27,"text":334,"correct":32},"探测器至端墙的距离不应大于探测器安装间距的1\u002F2",{"key":30,"text":336,"correct":22},"点型火灾探测器距多孔送风顶棚孔口的水平距离不应小于1.5m",{"key":73,"text":263,"correct":32},"ACE",{"id":340,"libraryId":5,"type":60,"typeLabel":61,"stem":341,"options":342,"answer":353,"analysis":33},975087,"下列关于线型红外光束感烟火灾探测器的安装说法错误的是（ ）。",[343,345,347,349,351],{"key":20,"text":344,"correct":22},"当探测区域的高度不大于20m时，光束轴线至顶棚的垂直距离宜为0.1m",{"key":24,"text":346,"correct":32},"当探测区域的高度大于20m时，光束轴线距探测区域的地（楼）面高度不宜超过14m",{"key":27,"text":348,"correct":32},"发射器和接收器之间的探测区域长度不宜超过100m",{"key":30,"text":350,"correct":32},"相邻两组探测器光束轴线的水平距离不应大于14m。探测器光束轴线至侧墙水平距离不应大于7m，且不应小于0.5m",{"key":73,"text":352,"correct":32},"发射器和接收器之间的光路上应无遮挡物或干扰源","BCDE",{"id":355,"libraryId":5,"type":60,"typeLabel":61,"stem":356,"options":357,"answer":368,"analysis":33},975088,"按照《建筑消防设施的维护管理》（GB25201）的规定，下列属于火灾报警控制器的检测主要内容有（ ）。",[358,360,362,364,366],{"key":20,"text":359,"correct":32},"试验火警报警",{"key":24,"text":361,"correct":32},"试验故障报警",{"key":27,"text":363,"correct":32},"火警优先",{"key":30,"text":365,"correct":32},"打印机打印功能",{"key":73,"text":367,"correct":22},"试验报警功能","ABCD",{"id":370,"libraryId":5,"type":60,"typeLabel":61,"stem":371,"options":372,"answer":383,"analysis":33},975089,"下列关于火灾自动报警系统消防联动控制要求说法正确的有（ ）。",[373,375,377,379,381],{"key":20,"text":374,"correct":22},"排烟风机入口处的支管上设置的280℃排烟防火阀在关闭后应直接联动控制风机停止",{"key":24,"text":376,"correct":32},"消防联动控制器控制疏散通道上设置的防火卷帘下降至距楼板面1.8m处，非疏散通道上设置的防火卷帘下降到楼板面",{"key":27,"text":378,"correct":22},"消防联动控制器应具有发出联动控制信号强制消防电梯停于首层或电梯转换层的功能",{"key":30,"text":380,"correct":32},"设置消防联动控制器的火灾自动报警系统，火灾声光警报器应由火灾报警控制器或消防联动控制器控制",{"key":73,"text":382,"correct":32},"消防应急广播系统的联动控制信号应由消防联动控制器发岀。当确认火灾后，应同时向全楼进行广播","BDE",{"id":385,"libraryId":5,"type":60,"typeLabel":61,"stem":386,"options":387,"answer":398,"analysis":33},975090,"下列关于火灾自动报警系统联动功能的测试方法描述正确的有（ ）。",[388,390,392,394,396],{"key":20,"text":389,"correct":22},"火灾报警控制器或消防联动控制器处于“自动”状态，触发同一楼层的两个不同探测形式的报警触发装置，核查建筑内的所有火灾声光警报器、消防应急广播系统的工作情况",{"key":24,"text":391,"correct":22},"火灾报警控制器或消防联动控制器处于“手动”状态，触发同一防火分区的两个不同探测形式的报警触发装置，核查相关区域安全技术防范系统的摄像机开启情况",{"key":27,"text":393,"correct":32},"火灾报警控制器或消防联动控制器处于“自动”状态，触发同一防火分区的两个不同探测形式的报警触发装置，核查疏散通道上由门禁系统控制的门和庭院的电动大门、停车场出入口挡杆打开情况",{"key":30,"text":395,"correct":22},"火灾报警控制器或消防联动控制器处于“自动”状态，触发同一防火分区的两个不同探测形式的报警触发装置，核查涉及疏散的电动栅杆自动打开情况",{"key":73,"text":397,"correct":32},"火灾报警控制器或消防联动控制器处于“手动”状态，触发同一防火分区的两个不同探测形式的报警触发装置，核查建筑内所有疏散通道的消防应急照明和疏散指示系统启动情况，测量系统全部投入应急状态的启动时间","CE",{"id":400,"libraryId":5,"type":78,"typeLabel":79,"stem":401,"options":402,"answer":85,"analysis":33},975091,"点型火灾探测器距多孔送风顶棚孔口的水平距离不应小于1.0m。",[403,404],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":406,"libraryId":5,"type":78,"typeLabel":79,"stem":265,"options":407,"answer":83,"analysis":33},975092,[408,409],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":411,"libraryId":5,"type":78,"typeLabel":79,"stem":412,"options":413,"answer":85,"analysis":33},975093,"当梁突出顶棚的高度超过0.8m时，被梁隔断的每个梁间区域应至少设置一只探测器。",[414,415],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":417,"libraryId":5,"type":78,"typeLabel":79,"stem":418,"options":419,"answer":85,"analysis":33},975094,"在顶棚下方的线型差温火灾探测器至顶棚距离宜为0.3m，相邻探测器之间水平距离不宜大于5m，探测器至墙壁距离宜为1～1.5m。",[420,421],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":423,"libraryId":5,"type":78,"typeLabel":79,"stem":424,"options":425,"answer":83,"analysis":33},975095,"从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离为25m。",[426,427],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":429,"libraryId":5,"type":78,"typeLabel":79,"stem":430,"options":431,"answer":85,"analysis":33},975096,"火灾警报器采用壁挂方式安装时，底边距地面高度为2.2m。",[432,433],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":435,"libraryId":5,"type":78,"typeLabel":79,"stem":436,"options":437,"answer":83,"analysis":33},975097,"本区域内无需要手动控制的消防联动设备时，集中报警系统和控制中心报警系统中的区域火灾报警控制器可设置在无人值班的场所。",[438,439],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":441,"libraryId":5,"type":78,"typeLabel":79,"stem":442,"options":443,"answer":83,"analysis":33},975098,"需要火灾自动报警系统联动控制的消防设备，其联动触发信号应采用两个独立的报警触发装置报警信号的“与”逻辑组合。",[444,445],{"key":20,"text":83,"correct":32},{"key":24,"text":85,"correct":22},{"id":447,"libraryId":5,"type":78,"typeLabel":79,"stem":448,"options":449,"answer":85,"analysis":33},975099,"消防联动控制器联动控制排烟口、排烟窗或排烟阀的开启，联动控制排烟风机的启动，同时停止该防火分区的空气调节系统。",[450,451],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":453,"libraryId":5,"type":78,"typeLabel":79,"stem":454,"options":455,"answer":85,"analysis":33},975100,"排烟风机入口处的支管上设置的280℃排烟防火阀在关闭后应直接联动控制风机停止。",[456,457],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},{"id":459,"libraryId":5,"type":78,"typeLabel":79,"stem":460,"options":461,"answer":85,"analysis":33},975101,"消防联动控制器应具有发出联动控制信号强制所有客梯停于首层或电梯转换层的功能。",[462,463],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":32},[465,468,471,474,477,480],{"id":15,"name":466,"category":7,"favorite":467},"领导干部任职前廉政法规知识测试题",92,{"id":469,"name":470,"category":7,"favorite":15},595,"建筑结构与设备",{"id":472,"name":473,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":475,"name":476,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":478,"name":479,"category":7,"favorite":8},534,"BIM工程师",{"id":481,"name":479,"category":7,"favorite":8},535]