[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-42":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":555},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,42,50,2486,[13,28,44,62,77,89,95,101,107,118,124,130,145,157,169,181,195,201,207,222,237,249,261,267,279,285,291,297,303,309,321,333,347,359,370,382,394,406,421,433,444,456,471,477,483,495,507,519,531,543],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},975002,3,"判断题","排烟防火阀应用场所为机械加压送风系统。（ ）",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":30,"typeLabel":31,"stem":32,"options":33,"answer":24,"analysis":27},975003,1,"单选题","更换火灾警报装置时，应做的启动功能测试为（ ）。",[34,36,38,41],{"key":20,"text":35,"correct":22},"仅采用联动启动的方式，检查火灾警报装置的声光启动功能",{"key":24,"text":37,"correct":26},"采用手动启动和联动启动的方式，检查火灾警报装置的声光启动功能",{"key":39,"text":40,"correct":22},"C","仅采用手动启动的方式，检查火灾警报装置的声光启动功能",{"key":42,"text":43,"correct":22},"D","以上均可",{"id":45,"libraryId":5,"type":46,"typeLabel":47,"stem":48,"options":49,"answer":61,"analysis":27},975004,2,"多选题","活动挡烟垂壁升降不顺畅、升降不到位原因为（ ）。",[50,52,54,56,58],{"key":20,"text":51,"correct":26},"导轨卡阻",{"key":24,"text":53,"correct":26},"上、下限位的调试不规范",{"key":39,"text":55,"correct":22},"控制器缺电",{"key":42,"text":57,"correct":22},"控制模块发生故障",{"key":59,"text":60,"correct":22},"E","联动公式错误","AB",{"id":63,"libraryId":5,"type":46,"typeLabel":47,"stem":64,"options":65,"answer":76,"analysis":27},975005,"室内消火栓箱主要由（ ）组成。",[66,68,70,72,74],{"key":20,"text":67,"correct":26},"箱体",{"key":24,"text":69,"correct":22},"闭式喷头",{"key":39,"text":71,"correct":26},"室内消火栓",{"key":42,"text":73,"correct":26},"消防水枪",{"key":59,"text":75,"correct":26},"消防水带","ACDE",{"id":78,"libraryId":5,"type":30,"typeLabel":31,"stem":79,"options":80,"answer":24,"analysis":27},975006,"更换消火栓按钮第二步是（ ）。",[81,83,85,87],{"key":20,"text":82,"correct":22},"检查新按钮，应无损伤、松动，核对新按钮规格型号与原按钮一致",{"key":24,"text":84,"correct":26},"分别分离新、旧消火栓按钮底座和上盖",{"key":39,"text":86,"correct":22},"对相关连接线路进行标记后，拆下旧按钮底座",{"key":42,"text":88,"correct":22},"进行火灾自动报警系统设备注册",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":25,"analysis":27},975007,"灭火器已经被使用过，拆卸时可以将瓶头阀门顶部对准人体。（ ）",[93,94],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":21,"analysis":27},975008,"更换防火卷帘手动按钮盒前应关闭防火卷帘控制器电源。（ ）",[99,100],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":21,"analysis":27},975009,"更换室内消火栓时，若消火栓附近设置有检修蝶阀,关闭该蝶阀即可。（ ）",[105,106],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":108,"libraryId":5,"type":30,"typeLabel":31,"stem":109,"options":110,"answer":20,"analysis":27},975010,"风机不能自动启动原因不包括（ ）。",[111,113,115,116],{"key":20,"text":112,"correct":26},"消防联动控制器处于“自动允许”状态",{"key":24,"text":114,"correct":22},"联动控制线路发生故障",{"key":39,"text":60,"correct":22},{"key":42,"text":117,"correct":22},"风机及控制柜发生故障",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},975011,"更换消防应急灯具之前，只关闭应急照明控制器即可。（ ）",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},975012,"风机运行温度异常原因为流量超过额定值，则维修方法为关小阀门。（ ）",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":46,"typeLabel":47,"stem":132,"options":133,"answer":144,"analysis":27},975013,"消防水泵接合器漏水的原因包含（ ）。",[134,136,138,140,142],{"key":20,"text":135,"correct":26},"止回阀安装方向错误",{"key":24,"text":137,"correct":22},"控制阀被误关闭",{"key":39,"text":139,"correct":22},"管道内水压过低",{"key":42,"text":141,"correct":26},"止回阀被砂石等异物卡住",{"key":59,"text":143,"correct":26},"止回阀损坏","ADE",{"id":146,"libraryId":5,"type":30,"typeLabel":31,"stem":147,"options":148,"answer":24,"analysis":27},975014,"如下图，圆圈内的阀门为（ ）。",[149,151,153,155],{"key":20,"text":150,"correct":22},"供水控制阀",{"key":24,"text":152,"correct":26},"检修蝶阀",{"key":39,"text":154,"correct":22},"高位消防水箱消火栓系统出水管路控制阀",{"key":42,"text":156,"correct":22},"消火栓系统泄水阀",{"id":158,"libraryId":5,"type":30,"typeLabel":31,"stem":159,"options":160,"answer":24,"analysis":27},975015,"下图中序号1的位置处为（ ）。",[161,163,165,167],{"key":20,"text":162,"correct":22},"溢流管",{"key":24,"text":164,"correct":26},"止回阀",{"key":39,"text":166,"correct":22},"明杆闸阀",{"key":42,"text":168,"correct":22},"流量开关",{"id":170,"libraryId":5,"type":30,"typeLabel":31,"stem":171,"options":172,"answer":42,"analysis":27},975016,"稳压泵启动频繁原因不包含（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"管网有泄漏，不能正常保压",{"key":24,"text":176,"correct":22},"稳压泵启停压力设定不正确",{"key":39,"text":178,"correct":22},"电接点压力表（压力开关）损坏",{"key":42,"text":180,"correct":26},"管道内残存空气",{"id":182,"libraryId":5,"type":46,"typeLabel":47,"stem":183,"options":184,"answer":61,"analysis":27},975017,"消防应急照明和疏散指示系统中主电故障报警的检查项目（ ）。",[185,187,189,191,193],{"key":20,"text":186,"correct":26},"检查输入电源是否完好",{"key":24,"text":188,"correct":26},"检查接触是否不良",{"key":39,"text":190,"correct":22},"检查蓄电池是否有损坏",{"key":42,"text":192,"correct":22},"检查蓄电池端子是否接触良好",{"key":59,"text":194,"correct":22},"检查蓄电池端子接线是否正确",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":25,"analysis":27},975018,"特殊响应喷头是指平均响应时间系数（RTI）小于或等于50（m.s）0.5。（ ）",[199,200],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":21,"analysis":27},975019,"消防应急广播控制器音源文件丢失的修复方法为：重新导入应急广播的音源文件。（ ）",[205,206],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":208,"libraryId":5,"type":46,"typeLabel":47,"stem":209,"options":210,"answer":221,"analysis":27},975020,"水基型灭火器分为（ ）。",[211,213,215,217,219],{"key":20,"text":212,"correct":26},"手提贮压式水基型灭火器",{"key":24,"text":214,"correct":22},"推车贮压式干粉型灭火器",{"key":39,"text":216,"correct":26},"推车贮压式水基型灭火器",{"key":42,"text":218,"correct":22},"手提贮压式干粉型灭火器",{"key":59,"text":220,"correct":22},"手提贮气式干粉型灭火器","AC",{"id":223,"libraryId":5,"type":46,"typeLabel":47,"stem":224,"options":225,"answer":236,"analysis":27},975021,"对灭火器外观目测判断，有下列情况之一者，应报废（ ）。",[226,228,230,232,234],{"key":20,"text":227,"correct":26},"铭牌标志脱落",{"key":24,"text":229,"correct":26},"瓶体被火烧过",{"key":39,"text":231,"correct":22},"瓶体有轻微变形",{"key":42,"text":233,"correct":22},"瓶体外部涂层脱落面积为气瓶总面积的1\u002F4",{"key":59,"text":235,"correct":26},"由不合法的维修机构维修过","ABE",{"id":238,"libraryId":5,"type":30,"typeLabel":31,"stem":239,"options":240,"answer":42,"analysis":27},975022,"灭火器维修合格证上的内容不包括（ ）。",[241,243,245,247],{"key":20,"text":242,"correct":22},"编号",{"key":24,"text":244,"correct":22},"总质量",{"key":39,"text":246,"correct":22},"维修机构名称",{"key":42,"text":248,"correct":26},"产品型号",{"id":250,"libraryId":5,"type":30,"typeLabel":31,"stem":251,"options":252,"answer":20,"analysis":27},975023,"某额定充装量为1KG的干粉型灭火器灭火剂再充装允许误差为（ ）。",[253,255,257,259],{"key":20,"text":254,"correct":26},"±5%",{"key":24,"text":256,"correct":22},"±6%",{"key":39,"text":258,"correct":22},"±7%",{"key":42,"text":260,"correct":22},"±8%",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":25,"analysis":27},975024,"维修灭火器时，当阀门与瓶体的连接螺纹锈住时，可以用硬物捶打方式拆卸。（ ）",[265,266],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":268,"libraryId":5,"type":30,"typeLabel":31,"stem":269,"options":270,"answer":39,"analysis":27},975025,"如下图，标号“3”的名称为（ ）。",[271,273,275,277],{"key":20,"text":272,"correct":22},"阀体",{"key":24,"text":274,"correct":22},"排水阀",{"key":39,"text":276,"correct":26},"阀杆",{"key":42,"text":278,"correct":22},"阀座",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":21,"analysis":27},975026,"维修灭火器时，再充装灭火剂之前，应对未更换的零部件进行清洁处理。（ ）",[283,284],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":21,"analysis":27},975027,"消防控制室不能远程手动启停风机的原因为多线控制盘未解锁处于“手动禁止”状态,则维修方法为：将多线控制盘解锁为“手动允许”状态。（ ）",[289,290],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":21,"analysis":27},975028,"更换干式报警阀阀瓣密封圈时，推动自动滴水阀的推杆，推杆能伸缩且流水已很微小时即可认定水已排尽。（ ）",[295,296],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":21,"analysis":27},975029,"风机运行振动剧烈原因可能为叶轮变形或不平衡。（ ）",[301,302],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":21,"analysis":27},975030,"更换闭式洒水喷头前，应先关闭该喷头所在分区水流指示器前的控制阀，再打开末端试水装置排出管道存水，然后再更换喷头.。（ ）",[307,308],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":310,"libraryId":5,"type":30,"typeLabel":31,"stem":311,"options":312,"answer":39,"analysis":27},975031,"更换防火卷帘手动按钮盒的步骤中，第一步是（ ）。",[313,315,317,319],{"key":20,"text":314,"correct":22},"关闭防火卷帘控制器电源",{"key":24,"text":316,"correct":22},"开启防火卷帘控制器电源",{"key":39,"text":318,"correct":26},"比对核查新换件规格型号和性能参数，应与待换件匹配或一致",{"key":42,"text":320,"correct":22},"用工具拆除损坏的手动按钮盒",{"id":322,"libraryId":5,"type":30,"typeLabel":31,"stem":323,"options":324,"answer":24,"analysis":27},975032,"贮压式灭火器拆卸程序第一步是（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":22},"拆卸灭火器瓶体和瓶头阀门",{"key":24,"text":328,"correct":26},"拆卸喷嘴、喷射软管和推车式灭火器的车架等外部组件",{"key":39,"text":330,"correct":22},"取岀灭火器瓶头阀门和虹吸管",{"key":42,"text":332,"correct":22},"卸下压力指示器和虹吸管",{"id":334,"libraryId":5,"type":46,"typeLabel":47,"stem":335,"options":336,"answer":236,"analysis":27},975033,"临时高压室内消火栓系统按稳压设施的设置情况，可分为（ ）。",[337,339,341,343,345],{"key":20,"text":338,"correct":26},"无稳压设施",{"key":24,"text":340,"correct":26},"上置式稳压",{"key":39,"text":342,"correct":22},"中置式稳压",{"key":42,"text":344,"correct":22},"高压式稳压",{"key":59,"text":346,"correct":26},"下置式稳压",{"id":348,"libraryId":5,"type":30,"typeLabel":31,"stem":349,"options":350,"answer":42,"analysis":27},975034,"室内消火栓关闭时本体渗漏原因不包含（ ）。",[351,353,355,357],{"key":20,"text":352,"correct":22},"阀瓣密封圈失效",{"key":24,"text":354,"correct":22},"消火栓手轮未旋转到位",{"key":39,"text":356,"correct":22},"阀瓣损伤",{"key":42,"text":358,"correct":26},"水压过小",{"id":360,"libraryId":5,"type":30,"typeLabel":31,"stem":361,"options":362,"answer":39,"analysis":27},975035,"下图标号“9”为室内消火栓的（ ）。",[363,364,366,368],{"key":20,"text":278,"correct":22},{"key":24,"text":365,"correct":22},"阀瓣",{"key":39,"text":367,"correct":26},"手轮",{"key":42,"text":369,"correct":22},"阀盖",{"id":371,"libraryId":5,"type":30,"typeLabel":31,"stem":372,"options":373,"answer":42,"analysis":27},975036,"下图为（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"干式直立喷头",{"key":24,"text":377,"correct":22},"直立喷头",{"key":39,"text":379,"correct":22},"齐平式喷头",{"key":42,"text":381,"correct":26},"隐蔽式喷头",{"id":383,"libraryId":5,"type":30,"typeLabel":31,"stem":384,"options":385,"answer":42,"analysis":27},975037,"干式系统空压机启动频繁的原因不包括（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"干式系统空压机启停压力设定不正确",{"key":24,"text":389,"correct":22},"报警阀气室相关管路处有渗漏点",{"key":39,"text":391,"correct":22},"系统侧管网有渗漏点",{"key":42,"text":393,"correct":26},"供水侧管网有渗漏点",{"id":395,"libraryId":5,"type":30,"typeLabel":31,"stem":396,"options":397,"answer":24,"analysis":27},975038,"更换消防电话系统、消防应急广播系统组件的第一步是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"确定故障点位置",{"key":24,"text":401,"correct":26},"接通电源，使消防电话系统、消防应急广播系统中组件处于故障状态",{"key":39,"text":403,"correct":22},"查找故障原因",{"key":42,"text":405,"correct":22},"填写《建筑消防设施故障维修记录表》",{"id":407,"libraryId":5,"type":46,"typeLabel":47,"stem":408,"options":409,"answer":420,"analysis":27},975039,"灭火器维修时经检查以下组件均没有损坏，但也应更换的为（ ）。",[410,412,414,416,418],{"key":20,"text":411,"correct":22},"虹吸管",{"key":24,"text":413,"correct":22},"压力指示器",{"key":39,"text":415,"correct":22},"喷嘴",{"key":42,"text":417,"correct":26},"密封片",{"key":59,"text":419,"correct":26},"水基型灭火剂","DE",{"id":422,"libraryId":5,"type":30,"typeLabel":31,"stem":423,"options":424,"answer":24,"analysis":27},975040,"仅可直立安装于供水支管上，水流向上冲向溅水盘，洒水形式为拋物体形的喷头为（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":22},"通用型喷头",{"key":24,"text":428,"correct":26},"直立型喷头",{"key":39,"text":430,"correct":22},"下垂型喷头",{"key":42,"text":432,"correct":22},"边墙型喷头",{"id":434,"libraryId":5,"type":30,"typeLabel":31,"stem":435,"options":436,"answer":20,"analysis":27},975041,"更换防烟排烟系统组件的操作程序第一步是（ ）。",[437,438,440,442],{"key":20,"text":318,"correct":26},{"key":24,"text":439,"correct":22},"使用扳手旋松旧执行器手柄固定螺栓，卸下手柄",{"key":39,"text":441,"correct":22},"取下执行器外壳，并拉出钢丝绳拉环",{"key":42,"text":443,"correct":22},"拆下执行器与阀体间的固定螺钉，卸下执行器",{"id":445,"libraryId":5,"type":30,"typeLabel":31,"stem":446,"options":447,"answer":20,"analysis":27},975042,"消防应急照明和疏散指示系统主电故障报警是指（ ）。",[448,450,452,454],{"key":20,"text":449,"correct":26},"主电工作指示灯熄灭，系统故障工作灯点亮，应急照明控制器主机报出主电故障",{"key":24,"text":451,"correct":22},"备电工作指示灯熄灭，系统故障工作灯点亮，应急照明控制器主机报出备电故障",{"key":39,"text":453,"correct":22},"备工作指示灯熄灭，系统故障工作灯点亮，应急照明控制器主机报出主电故障",{"key":42,"text":455,"correct":22},"主电工作指示灯熄灭，系统故障工作灯点亮，应急照明控制器主机报出备电故障",{"id":457,"libraryId":5,"type":46,"typeLabel":47,"stem":458,"options":459,"answer":470,"analysis":27},975043,"消防控制室远程不能启停消防水泵的原因包括（ ）。",[460,462,464,466,468],{"key":20,"text":461,"correct":26},"专用线路开路或断路",{"key":24,"text":463,"correct":26},"多线控制盘损坏",{"key":39,"text":465,"correct":26},"多线控制盘配用的切换模块线路发生故障",{"key":42,"text":467,"correct":22},"防泵组电气控制柜处于“自动”状态",{"key":59,"text":469,"correct":26},"多线控制盘未解锁处于“手动禁止”状态","ABCE",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":21,"analysis":27},975044,"常开式防火门无法锁定在开启状态的故障原可能因为电压过低。（ ）",[475,476],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":21,"analysis":27},975045,"挡烟垂壁不能自动启动原因可能为未编写联动公式或联动公式错误。（ ）",[481,482],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":484,"libraryId":5,"type":30,"typeLabel":31,"stem":485,"options":486,"answer":39,"analysis":27},975046,"下列关于点型感温火灾探测器功能测试的方法不正确的是（ ）。",[487,489,491,493],{"key":20,"text":488,"correct":22},"使用点型感温火灾探测器试验装置的热源加热",{"key":24,"text":490,"correct":22},"核查探测器报警确认灯和火灾报警控制器火警信号显示",{"key":39,"text":492,"correct":26},"移开加热源，自动复位火灾报警控制器",{"key":42,"text":494,"correct":22},"核查探测器报警确认灯在复位前后的变化情况",{"id":496,"libraryId":5,"type":30,"typeLabel":31,"stem":497,"options":498,"answer":20,"analysis":27},975047,"下列关于手动火灾报警按钮功能测试的方法不正确的是（ ）。",[499,501,503,505],{"key":20,"text":500,"correct":26},"确认手动火灾报警按钮与火灾报警控制器断开电源，处于正常监视状态",{"key":24,"text":502,"correct":22},"按下手动火灾报警按钮的启动零件",{"key":39,"text":504,"correct":22},"核查火灾报警控制器的显示和手动火灾报警按钮的报警确认灯",{"key":42,"text":506,"correct":22},"复位火灾报警控制器，更换或复位启动零件，核查手动火灾报警按钮的报警确认灯状态",{"id":508,"libraryId":5,"type":30,"typeLabel":31,"stem":509,"options":510,"answer":24,"analysis":27},975048,"火灾警报装置启动后，使用声级计测量其声信号至少在一个方向上3m处的声压级应不小于75dB（A计权），具有光警报功能的，光信号在100～500lx环境光线下，（ ）处应清晰可见。",[511,513,515,517],{"key":20,"text":512,"correct":22},"20m",{"key":24,"text":514,"correct":26},"25m",{"key":39,"text":516,"correct":22},"30m",{"key":42,"text":518,"correct":22},"40m",{"id":520,"libraryId":5,"type":30,"typeLabel":31,"stem":521,"options":522,"answer":24,"analysis":27},975049,"火灾警报装置启动后，使用声级计测量其声信号至少在一个方向上（ ）处的声压级应不小于75dB（A计权），具有光警报功能的，光信号在100～500lx环境光线下，25m处应清晰可见。",[523,525,527,529],{"key":20,"text":524,"correct":22},"1m",{"key":24,"text":526,"correct":26},"3m",{"key":39,"text":528,"correct":22},"5m",{"key":42,"text":530,"correct":22},"10m",{"id":532,"libraryId":5,"type":30,"typeLabel":31,"stem":533,"options":534,"answer":39,"analysis":27},975050,"下列关于火灾自动报警系统消防联动控制要求,说法错误的是（ ）。",[535,537,539,541],{"key":20,"text":536,"correct":22},"消防联动控制器应能按设定的控制逻辑向各相关受控设备发出联动控制信号，并接收相关设备的联动反馈信号",{"key":24,"text":538,"correct":22},"需要火灾自动报警系统联动控制的消防设备，其联动触发信号应采用两个独立的报警触发装置报警信号的“与”逻辑组合",{"key":39,"text":540,"correct":26},"消防联动控制器联动控制排烟口、排烟窗或排烟阀的开启，联动控制排烟风机的启动，同时停止该防火分区的空气调节系统",{"key":42,"text":542,"correct":22},"消防联动控制器应具有发出联动控制信号强制所有电梯停于首层或电梯转换层的功能",{"id":544,"libraryId":5,"type":30,"typeLabel":31,"stem":545,"options":546,"answer":42,"analysis":27},975051,"排烟风机入口处的排烟防火阀在（ ）关闭后直接联动排烟风机停止。",[547,549,551,553],{"key":20,"text":548,"correct":22},"70℃",{"key":24,"text":550,"correct":22},"150℃",{"key":39,"text":552,"correct":22},"250℃",{"key":42,"text":554,"correct":26},"280℃",[556,559,562,565,568,571],{"id":30,"name":557,"category":7,"favorite":558},"领导干部任职前廉政法规知识测试题",92,{"id":560,"name":561,"category":7,"favorite":30},595,"建筑结构与设备",{"id":563,"name":564,"category":7,"favorite":30},715,"招标采购专业知识与法律法规",{"id":566,"name":567,"category":7,"favorite":30},848,"市政方向-通用基础",{"id":569,"name":570,"category":7,"favorite":8},534,"BIM工程师",{"id":572,"name":570,"category":7,"favorite":8},535]