[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-40":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":428},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,40,50,2486,[13,38,53,68,83,97,111,125,139,154,168,182,196,206,212,218,224,230,236,242,248,254,260,266,272,278,284,290,296,302,308,314,320,326,332,338,344,350,356,362,368,374,380,386,392,398,404,410,416,422],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},974901,2,"多选题","下列属于水枪或软管卷盘喷嘴处无水或压力不足的故障原因是（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","室内消火栓进水管检修阀被误关闭",true,{"key":24,"text":25,"correct":22},"B","系统管网水压不足",{"key":27,"text":28,"correct":29},"C","消火栓手轮未旋转到位",false,{"key":31,"text":32,"correct":22},"D","水带与消火栓、水带与水枪连接未到位或接口损伤、变形",{"key":34,"text":35,"correct":22},"E","水带或软管破损","ABDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},974902,"下列属于水枪或软管卷盘喷嘴处无水或压力不足的故障维修方法的是（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"打开检修阀",{"key":24,"text":45,"correct":22},"进一步排查系统管网水压不足的原因并处理",{"key":27,"text":47,"correct":22},"更换破损的水带或软管",{"key":31,"text":49,"correct":22},"重新绑扎水带或软管并测试无漏水",{"key":34,"text":51,"correct":29},"检修井闸阀保持常开","ABCD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},974903,"下列属于消火栓按钮启动后不报警的故障原因是（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"消火栓按钮损坏",{"key":24,"text":60,"correct":22},"线路损坏",{"key":27,"text":62,"correct":22},"设备未注册",{"key":31,"text":64,"correct":29},"供水管道无水",{"key":34,"text":66,"correct":22},"消防泵组电气控制柜处于手动状态","ABCE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},974904,"下列属于消火栓按钮启动后不报警的故障维修方法有（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":22},"维修或更换消火栓按钮",{"key":24,"text":75,"correct":22},"对线路进行排查和维修",{"key":27,"text":77,"correct":22},"重新检查和注册在役设备",{"key":31,"text":79,"correct":22},"消防泵组电气控制柜平时应处于自动状态",{"key":34,"text":81,"correct":22},"及时维修或报修","ABCDE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":82,"analysis":37},974905,"下列属于稳压装置不能稳压的原因有（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":22},"缺电",{"key":24,"text":90,"correct":22},"消防泵组电气控制柜损坏",{"key":27,"text":92,"correct":22},"消防水箱无水",{"key":31,"text":94,"correct":22},"压力开关损坏",{"key":34,"text":96,"correct":22},"稳压泵进水管阀门被误关闭",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":36,"analysis":37},974906,"下列属于手提式灭火器常见的故障有（ ）。",[101,103,105,107,109],{"key":20,"text":102,"correct":22},"灭火器瓶体存在明显机械损伤和锈蚀",{"key":24,"text":104,"correct":22},"贴花标志内容损坏，模糊不清",{"key":27,"text":106,"correct":29},"喷射控制枪存在明显变形、裂纹",{"key":31,"text":108,"correct":22},"阀门开启机构存在损伤",{"key":34,"text":110,"correct":22},"灭火器已被开启",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":82,"analysis":37},974907,"检测发现，机械加压送风系统风机风量不足，下列属于其风量不足的可能原因是（ ）。",[115,117,119,121,123],{"key":20,"text":116,"correct":22},"管道内阀门未打开",{"key":24,"text":118,"correct":22},"调节阀门开度不够",{"key":27,"text":120,"correct":22},"风机传动带松弛",{"key":31,"text":122,"correct":22},"叶轮与轴的连接松动",{"key":34,"text":124,"correct":22},"风口开启过多",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":52,"analysis":37},974908,"下列属于风阀动作后无反馈的故障原因是（ ）。",[129,131,133,135,137],{"key":20,"text":130,"correct":22},"风阀动作未到位",{"key":24,"text":132,"correct":22},"微动开关损坏",{"key":27,"text":134,"correct":22},"信号线路开路或断路",{"key":31,"text":136,"correct":22},"输入模块损坏",{"key":34,"text":138,"correct":29},"控制器缺电",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":153,"analysis":37},974909,"下列属于挡烟垂壁不能自动启动的故障原因是（ ）。",[143,145,147,149,151],{"key":20,"text":144,"correct":22},"控制模块或线路发生故障",{"key":24,"text":146,"correct":22},"配用探测器发生故障",{"key":27,"text":148,"correct":29},"控制器内电气发生故障",{"key":31,"text":150,"correct":22},"未编写联动公式或联动公式错误",{"key":34,"text":152,"correct":29},"驱动电机发生故障或缺电","ABD",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":82,"analysis":37},974910,"下列属于风机运行振动剧烈的故障原因是（ ）。",[158,160,162,164,166],{"key":20,"text":159,"correct":22},"叶轮定位螺栓或夹轮螺栓松动",{"key":24,"text":161,"correct":22},"叶片质量不对称或部分叶片磨损、腐蚀",{"key":27,"text":163,"correct":22},"叶片上附有不均匀的附着物",{"key":31,"text":165,"correct":22},"叶轮变形或不平衡",{"key":34,"text":167,"correct":22},"基础螺栓松动，引起共振",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":67,"analysis":37},974911,"下列属于风机运行温度异常有的原因有（ ）。",[172,174,176,178,180],{"key":20,"text":173,"correct":22},"管网阻力过大",{"key":24,"text":175,"correct":22},"输入电压过高或过低",{"key":27,"text":177,"correct":22},"风机轴与电动机轴不同心",{"key":31,"text":179,"correct":29},"轴承部件磨损，间隙过大",{"key":34,"text":181,"correct":22},"风机内部、叶轮积灰",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":82,"analysis":37},974912,"下列属于风机运行温度异常的维修方法是（ ）。",[186,188,190,192,194],{"key":20,"text":187,"correct":22},"排查风口防护罩、管网变形情况和阀门开启度，及时调整、维修或更换",{"key":24,"text":189,"correct":22},"清洗轴承后更换合格润滑油脂",{"key":27,"text":191,"correct":22},"检查供电情况，维修或报修",{"key":31,"text":193,"correct":22},"加足润滑油脂",{"key":34,"text":195,"correct":22},"更换供电线路电线",{"id":197,"libraryId":5,"type":198,"typeLabel":199,"stem":200,"options":201,"answer":203,"analysis":37},974913,3,"判断题","消防电话分机与底座意外脱落会导致分机不断呼叫电话主机。",[202,204],{"key":20,"text":203,"correct":22},"正确",{"key":24,"text":205,"correct":29},"错误",{"id":207,"libraryId":5,"type":198,"typeLabel":199,"stem":208,"options":209,"answer":205,"analysis":37},974914,"广播控制器音源文件丢失会导致消防应急广播启动后现场音箱无音源输出。",[210,211],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":213,"libraryId":5,"type":198,"typeLabel":199,"stem":214,"options":215,"answer":205,"analysis":37},974915,"消防电话系统分机或插孔“巡检灯”不闪亮，可能是分机外挂线路发生故障，应修复外挂线路故至正常。",[216,217],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":219,"libraryId":5,"type":198,"typeLabel":199,"stem":220,"options":221,"answer":205,"analysis":37},974916,"消防应急广播模块拆卸、编码后，将广播模块与底座卡扣对准，平行于底座方向用力按下即可。",[222,223],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":225,"libraryId":5,"type":198,"typeLabel":199,"stem":226,"options":227,"answer":205,"analysis":37},974917,"消防电话系统、消防应急广播系统有故障时，可根据火灾报警控制器显示的故障信息，对照系统平面布置图，可确定故障点位置，更换组件。",[228,229],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":231,"libraryId":5,"type":198,"typeLabel":199,"stem":232,"options":233,"answer":205,"analysis":37},974918,"发现消防电话系统、消防应急广播系统故障，查找出故障原因、更换组件后，还需要做功能测试才算完结。",[234,235],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":237,"libraryId":5,"type":198,"typeLabel":199,"stem":238,"options":239,"answer":205,"analysis":37},974919,"系统应急启动后，总建筑面积为20000m2的地下、半地下建筑蓄电池电源供电时持续工作时间不应少于1.0h。",[240,241],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":243,"libraryId":5,"type":198,"typeLabel":199,"stem":244,"options":245,"answer":203,"analysis":37},974920,"系统应急启动后，建筑高度50m的图书馆蓄电池电源供电时持续工作时间不应少于0.5h。",[246,247],{"key":20,"text":203,"correct":22},{"key":24,"text":205,"correct":29},{"id":249,"libraryId":5,"type":198,"typeLabel":199,"stem":250,"options":251,"answer":205,"analysis":37},974921,"消防应急集中电源及消防应急灯具登录故障时，设备信息查询菜单中显示的设备类型和登录类型为红色。",[252,253],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":255,"libraryId":5,"type":198,"typeLabel":199,"stem":256,"options":257,"answer":205,"analysis":37},974922,"集中型应急照明控制器应急电源开机无显示是因为供电线路断路或者供电电压过低。",[258,259],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":261,"libraryId":5,"type":198,"typeLabel":199,"stem":262,"options":263,"answer":205,"analysis":37},974923,"测试自带电源型灯具持续应急时间是否满足设置场所要求，可从消防控制室远程将自带电源型灯具转入应急照明模式，利用计时器记录其应急照明时间。",[264,265],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":267,"libraryId":5,"type":198,"typeLabel":199,"stem":268,"options":269,"answer":205,"analysis":37},974924,"在寒冷地区，若排水阀堵塞，消火栓栓体内存有余水，冬季余水冻结，消火栓打开时会无水。",[270,271],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":273,"libraryId":5,"type":198,"typeLabel":199,"stem":274,"options":275,"answer":205,"analysis":37},974925,"检修井闸阀被误打开，会导致消火栓打开时无水。",[276,277],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":279,"libraryId":5,"type":198,"typeLabel":199,"stem":280,"options":281,"answer":205,"analysis":37},974926,"消火栓出水压力不足时，消防水泵进出水管路阀门应保持全闭，并以铅封锁链锁定状态。",[282,283],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":285,"libraryId":5,"type":198,"typeLabel":199,"stem":286,"options":287,"answer":205,"analysis":37},974927,"消防水泵试水管路阀门被误开启会导致消火栓打开时无水。",[288,289],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":291,"libraryId":5,"type":198,"typeLabel":199,"stem":292,"options":293,"answer":203,"analysis":37},974928,"稳压设施压力设定不正确或稳压设施损坏也会造成会导致消火栓出水压力不足。",[294,295],{"key":20,"text":203,"correct":22},{"key":24,"text":205,"correct":29},{"id":297,"libraryId":5,"type":198,"typeLabel":199,"stem":298,"options":299,"answer":205,"analysis":37},974929,"出水管路泄压阀起跳泄水会导致消火栓出水口平时有水渗出。",[300,301],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":303,"libraryId":5,"type":198,"typeLabel":199,"stem":304,"options":305,"answer":205,"analysis":37},974930,"室内消火栓系统给水管网振动大，发出异响、噪声，可能是消火栓泵出口未采用刚性连接",[306,307],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":309,"libraryId":5,"type":198,"typeLabel":199,"stem":310,"options":311,"answer":205,"analysis":37},974931,"管网流速过快会导致消火栓出水压力不足。",[312,313],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":315,"libraryId":5,"type":198,"typeLabel":199,"stem":316,"options":317,"answer":203,"analysis":37},974932,"消火栓未关严，会导致消火栓出水口平时有水渗出，也会导致室内消火栓关闭时本体渗漏。",[318,319],{"key":20,"text":203,"correct":22},{"key":24,"text":205,"correct":29},{"id":321,"libraryId":5,"type":198,"typeLabel":199,"stem":322,"options":323,"answer":203,"analysis":37},974933,"室内消火栓进水管检修阀被误关闭会造成系统管网水压不足。",[324,325],{"key":20,"text":203,"correct":22},{"key":24,"text":205,"correct":29},{"id":327,"libraryId":5,"type":198,"typeLabel":199,"stem":328,"options":329,"answer":205,"analysis":37},974934,"消防泵组电气控制柜处于自动状态时，消火栓按钮启动后会不报警或不启泵。",[330,331],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":333,"libraryId":5,"type":198,"typeLabel":199,"stem":334,"options":335,"answer":203,"analysis":37},974935,"稳压装置不能稳压，可能是消防水箱无水或稳压泵出水管阀门被误关闭。",[336,337],{"key":20,"text":203,"correct":22},{"key":24,"text":205,"correct":29},{"id":339,"libraryId":5,"type":198,"typeLabel":199,"stem":340,"options":341,"answer":205,"analysis":37},974936,"用于干粉灭火器的驱动气体的露点不应高于55℃。",[342,343],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":345,"libraryId":5,"type":198,"typeLabel":199,"stem":346,"options":347,"answer":205,"analysis":37},974937,"水压试验压力应按灭火器铭牌标志上规定的水压试验压力值进行，保压3min。水压试验时不应有泄漏、部件脱落、破裂和可见的宏观变形。",[348,349],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":351,"libraryId":5,"type":198,"typeLabel":199,"stem":352,"options":353,"answer":205,"analysis":37},974938,"水基型灭火器压力指示器的标识为“F”。干粉灭火器压力指示器的标识为“S”。",[354,355],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":357,"libraryId":5,"type":198,"typeLabel":199,"stem":358,"options":359,"answer":205,"analysis":37},974939,"贮压式干粉灭火器与贮压式水基型灭火器的基本结构相同，主要组成部件的设计或工艺要求也相同。",[360,361],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":363,"libraryId":5,"type":198,"typeLabel":199,"stem":364,"options":365,"answer":205,"analysis":37},974940,"手提式灭火器压力指示器不指示在黄色区域范围属故障，需维修。",[366,367],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":369,"libraryId":5,"type":198,"typeLabel":199,"stem":370,"options":371,"answer":203,"analysis":37},974941,"灭火器贴花标志上产品信息中灭火剂名称及充装量，驱动气体名称及充装量，生产商名称、地址和电话，适用灭火种类及使用方法等内容损坏，模糊不清，都属于需维修的故障。",[372,373],{"key":20,"text":203,"correct":22},{"key":24,"text":205,"correct":29},{"id":375,"libraryId":5,"type":198,"typeLabel":199,"stem":376,"options":377,"answer":205,"analysis":37},974942,"水基型灭火器超过出厂时间10年报废。",[378,379],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":381,"libraryId":5,"type":198,"typeLabel":199,"stem":382,"options":383,"answer":205,"analysis":37},974943,"干粉型灭火器超过出厂时间12年报废",[384,385],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":387,"libraryId":5,"type":198,"typeLabel":199,"stem":388,"options":389,"answer":205,"analysis":37},974944,"干粉型灭火器出厂期满5年首次维修，首次维修以后每1年维修。",[390,391],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":393,"libraryId":5,"type":198,"typeLabel":199,"stem":394,"options":395,"answer":205,"analysis":37},974945,"水基型灭火器出厂期满3年首次维修，首次维修以后每满2年维修。",[396,397],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":399,"libraryId":5,"type":198,"typeLabel":199,"stem":400,"options":401,"answer":205,"analysis":37},974946,"灭火器上的密封片、圈、垫等密封零件和灭火剂是每次维修必须更换的零部件。",[402,403],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":405,"libraryId":5,"type":198,"typeLabel":199,"stem":406,"options":407,"answer":205,"analysis":37},974947,"铭牌标志脱落，或虽有铭牌标志，但标志上生产商名称无法识别、灭火剂名称和充装量模糊不清，以及永久性标志内容无法辨认的，灭火器应送修。",[408,409],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":411,"libraryId":5,"type":198,"typeLabel":199,"stem":412,"options":413,"answer":205,"analysis":37},974948,"压力计量仪器应采用压力范围为0～3MPa，精度等级不小于1.6级的压力，或满足同等精度要求的其他传感仪器；",[414,415],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":417,"libraryId":5,"type":198,"typeLabel":199,"stem":418,"options":419,"answer":205,"analysis":37},974949,"风机运行振动剧烈，可能是控制线路发生故障。",[420,421],{"key":20,"text":203,"correct":29},{"key":24,"text":205,"correct":22},{"id":423,"libraryId":5,"type":198,"typeLabel":199,"stem":424,"options":425,"answer":203,"analysis":37},974950,"风机的控制柜未处于“手动”状态，现场不能手动启停风机。",[426,427],{"key":20,"text":203,"correct":22},{"key":24,"text":205,"correct":29},[429,433,436,439,442,445],{"id":430,"name":431,"category":7,"favorite":432},1,"领导干部任职前廉政法规知识测试题",92,{"id":434,"name":435,"category":7,"favorite":430},595,"建筑结构与设备",{"id":437,"name":438,"category":7,"favorite":430},715,"招标采购专业知识与法律法规",{"id":440,"name":441,"category":7,"favorite":430},848,"市政方向-通用基础",{"id":443,"name":444,"category":7,"favorite":8},534,"BIM工程师",{"id":446,"name":444,"category":7,"favorite":8},535]