[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-39":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":632},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,39,50,2486,[13,34,44,56,68,80,92,104,112,120,132,144,156,165,177,189,201,213,225,235,247,259,271,283,295,307,319,331,341,353,365,377,389,401,412,424,442,456,471,486,499,513,526,538,547,559,573,587,602,617],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},974851,1,"单选题","下列不属于消防电话系统分机不断呼叫电话主机的原因是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","分机与底座意外脱落",false,{"key":24,"text":25,"correct":22},"B","分机外挂线路发生故障",{"key":27,"text":28,"correct":22},"C","分机或插孔间重码",{"key":30,"text":31,"correct":32},"D","电话总线断路",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},974852,"下列不属于消防电话系统分机或插孔“巡检灯”不闪亮的原因是（ ）。",[38,40,41,42],{"key":20,"text":39,"correct":22},"分机或插孔自身损坏",{"key":24,"text":25,"correct":32},{"key":27,"text":31,"correct":22},{"key":30,"text":43,"correct":22},"分机或插孔安装不牢靠，底座接线松动",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":30,"analysis":33},974853,"下列不属于消防应急广播无法应急启动的原因是（ ）。",[48,50,52,54],{"key":20,"text":49,"correct":22},"广播控制器发生通信故障或担坏",{"key":24,"text":51,"correct":22},"广播控制器音源文件丢失",{"key":27,"text":53,"correct":22},"功率放大器发生线路故障导致过载或损坏",{"key":30,"text":55,"correct":32},"广播模块损坏或广播线路发生故障",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":27,"analysis":33},974854,"下列不属于消防电话系统、消防应急广播系统组件的更换方法查找故障原因中确定故障产生的原因是（ ）。",[60,62,64,66],{"key":20,"text":61,"correct":22},"线路故障",{"key":24,"text":63,"correct":22},"底座接触不良",{"key":27,"text":65,"correct":32},"火灾报警控制器故障",{"key":30,"text":67,"correct":22},"器件自身故障",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":20,"analysis":33},974855,"消防电话分机、消防电话插孔通话功能测试：检查消防电话分机，消防电话插孔与消防电话主机之间的呼叫与通话功能，消防电话主机应能显示每部分机或电话插孔的位置，呼叫铃声和通话语音应清晰：进行消防电话主机复位、自检操作；观察（ ），应处于正常监视状态。",[72,74,76,78],{"key":20,"text":73,"correct":32},"2min",{"key":24,"text":75,"correct":22},"3min",{"key":27,"text":77,"correct":22},"5min",{"key":30,"text":79,"correct":22},"10min",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":27,"analysis":33},974856,"下列不属于光源故障的是（ ）。",[84,86,88,90],{"key":20,"text":85,"correct":22},"消防应急照明灯应急时不亮",{"key":24,"text":87,"correct":22},"消防应急标志灯不亮",{"key":27,"text":89,"correct":32},"备电工作指示灯熄灭",{"key":30,"text":91,"correct":22},"标志灯光源损坏",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":27,"analysis":33},974857,"建筑高度大于100m的民用，应急照明系统应急启动后，自带电源型灯具蓄电池电源供电时持续工作时间不应少于（ ）h。",[96,98,100,102],{"key":20,"text":97,"correct":22},"0.5",{"key":24,"text":99,"correct":22},"1.0",{"key":27,"text":101,"correct":32},"1.5",{"key":30,"text":103,"correct":22},"2.0",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":24,"analysis":33},974858,"医疗建筑应急照明系统应急启动后，自带电源型灯具蓄电池电源供电时持续工作时间不应少于（ ）h。",[108,109,110,111],{"key":20,"text":97,"correct":22},{"key":24,"text":99,"correct":32},{"key":27,"text":101,"correct":22},{"key":30,"text":103,"correct":22},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":24,"analysis":33},974859,"总建筑面积大于100000m的公共建筑应急照明系统应急启动后，自带电源型灯具蓄电池电源供电时持续工作时间不应少于（ ）h。",[116,117,118,119],{"key":20,"text":97,"correct":22},{"key":24,"text":99,"correct":32},{"key":27,"text":101,"correct":22},{"key":30,"text":103,"correct":22},{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":20,"analysis":33},974860,"下列不属于防火卷帘帘面不速放的原因是（ ）。",[124,126,128,130],{"key":20,"text":125,"correct":32},"异物卡住",{"key":24,"text":127,"correct":22},"电磁铁没接线",{"key":27,"text":129,"correct":22},"门体与导轨卡住",{"key":30,"text":131,"correct":22},"附件链条生锈",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":30,"analysis":33},974861,"下列不属于防火卷帘运行时噪声大的原因是（ ）。",[136,138,140,142],{"key":20,"text":137,"correct":22},"五金件安装不牢固",{"key":24,"text":139,"correct":22},"帘面走位",{"key":27,"text":141,"correct":22},"未涂覆润滑油",{"key":30,"text":143,"correct":32},"导轨变形卡住帘面",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":24,"analysis":33},974862,"下列属于防火卷帘控制器面板灯不亮的原因是（ ）。",[148,150,152,154],{"key":20,"text":149,"correct":22},"接触器触头及线圈问题",{"key":24,"text":151,"correct":32},"没有接零线",{"key":27,"text":153,"correct":22},"控制器主板问题",{"key":30,"text":155,"correct":22},"电池接线松动",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":27,"analysis":33},974863,"下列属于扬声器\"嘟嘟”循环鸣叫，面板电源灯闪烁，故障灯常亮的原因是（ ）。",[160,161,162,164],{"key":20,"text":149,"correct":22},{"key":24,"text":151,"correct":22},{"key":27,"text":163,"correct":32},"缺相、断电",{"key":30,"text":155,"correct":22},{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":30,"analysis":33},974864,"下列不属于对防火门关闭后无法反馈信息的故障原因是（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"电动闭门器滑槽内的信号反馈装置调试不到位或损坏",{"key":24,"text":172,"correct":22},"未安装门磁开关或门磁开关损坏",{"key":27,"text":174,"correct":22},"接线不正确",{"key":30,"text":176,"correct":32},"控制板损坏",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":20,"analysis":33},974865,"下列属于室内消火栓系统按用途分类的是（ ）。",[181,183,185,187],{"key":20,"text":182,"correct":32},"独立管网的消火栓系统",{"key":24,"text":184,"correct":22},"环状管网消火栓系统",{"key":27,"text":186,"correct":22},"枝状管网消火栓系统",{"key":30,"text":188,"correct":22},"临时高压消火栓系统",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":27,"analysis":33},974866,"消防水鹤在严寒地区城市主要干道上的布置间距宜为（ ）m，连接消防水鹤的市政给水管管径不宜小于DN200。",[193,195,197,199],{"key":20,"text":194,"correct":22},"500",{"key":24,"text":196,"correct":22},"800",{"key":27,"text":198,"correct":32},"1000",{"key":30,"text":200,"correct":22},"1500",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":33},974867,"火灾时消防水鹤的出流量不宜低于（ ），且供水压力从地面算起不应小于（ ）。",[205,207,209,211],{"key":20,"text":206,"correct":32},"30L\u002Fs；0.10MPa",{"key":24,"text":208,"correct":22},"40L\u002Fs；0.10MPa",{"key":27,"text":210,"correct":22},"30L\u002Fs；0.15MPa",{"key":30,"text":212,"correct":22},"40L\u002Fs；0.15MPa",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":30,"analysis":33},974868,"下列不属于消火栓无法打开的原因是（ ）。",[217,219,221,223],{"key":20,"text":218,"correct":22},"转动部件粘连或锈死",{"key":24,"text":220,"correct":22},"阀杆断裂",{"key":27,"text":222,"correct":22},"排水阀堵塞，消火栓栓体内存有余水，冬季余水冻结",{"key":30,"text":224,"correct":32},"消火栓检修井闸阀被误关闭",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":30,"analysis":33},974869,"下列属于消火栓打开时无水的故障原因是（ ）。",[229,230,232,234],{"key":20,"text":224,"correct":22},{"key":24,"text":231,"correct":22},"系统管路分段控制阀被误关闭",{"key":27,"text":233,"correct":22},"供水管道无水",{"key":30,"text":222,"correct":32},{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":30,"analysis":33},974870,"下列不属于对于消火栓打开时无水的维修方法的是（ ）。",[239,241,243,245],{"key":20,"text":240,"correct":22},"检修井闸阀保持常开",{"key":24,"text":242,"correct":22},"分段控制阀保持常开",{"key":27,"text":244,"correct":22},"进一步排查供水管道无水原因",{"key":30,"text":246,"correct":32},"疏通排水阀",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":33},974871,"下列不属于手提贮压式水基型灭火器的组成部分的是（ ）。",[251,253,255,257],{"key":20,"text":252,"correct":22},"压力指示器",{"key":24,"text":254,"correct":32},"阀门开启手柄",{"key":27,"text":256,"correct":22},"瓶头阀门",{"key":30,"text":258,"correct":22},"灭火剂及驱动气体",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":27,"analysis":33},974872,"水基型灭火器压力指示器的标识为（ ）。",[263,265,267,269],{"key":20,"text":264,"correct":22},"F",{"key":24,"text":266,"correct":22},"M",{"key":27,"text":268,"correct":32},"S",{"key":30,"text":270,"correct":22},"T",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":30,"analysis":33},974873,"当定期对灭火器进行巡检、维护时，发现其存在缺陷，应及时将灭火器送原生产企业维修部门或（ ）进行维修。",[275,277,279,281],{"key":20,"text":276,"correct":22},"任何维修机构",{"key":24,"text":278,"correct":22},"由销售单位",{"key":27,"text":280,"correct":22},"由使用企业授权的维修机构",{"key":30,"text":282,"correct":32},"由生产企业授权的维修机构",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":20,"analysis":33},974874,"灭火器每次维修必须更换的零部件是（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":32},"灭火器上的密封片、圈、垫等密封零件",{"key":24,"text":290,"correct":22},"干粉型灭火剂",{"key":27,"text":292,"correct":22},"喷嘴",{"key":30,"text":294,"correct":22},"虹吸管",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":27,"analysis":33},974875,"对外观目测判断，下列不应报废的是（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":22},"铭牌标志脱落",{"key":24,"text":302,"correct":22},"瓶体被火烧过",{"key":27,"text":304,"correct":32},"瓶体外部涂层脱落面积大于气瓶总面积的1\u002F4",{"key":30,"text":306,"correct":22},"由不合法的维修机构维修过",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":30,"analysis":33},974876,"下列灭火器应进行报废的是（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":22},"干粉型灭火器超过出厂时间8年",{"key":24,"text":314,"correct":22},"水基型灭火器超过出厂时间5年",{"key":27,"text":316,"correct":22},"瓶体外部涂层脱落面积约占气瓶总面积的1\u002F3",{"key":30,"text":318,"correct":32},"铭牌上永久性标志内容无法辨认",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":20,"analysis":33},974877,"灭火器维修用房应满足《灭火器维修》（GA95）的要求，建筑面积不应少于（ ）㎡。",[323,325,327,329],{"key":20,"text":324,"correct":32},"100",{"key":24,"text":326,"correct":22},"150",{"key":27,"text":328,"correct":22},"200",{"key":30,"text":330,"correct":22},"300",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":30,"analysis":33},974878,"灭火器维修水压试验机的额定工作压力不小于（ ）MPa。",[335,336,337,339],{"key":20,"text":101,"correct":22},{"key":24,"text":103,"correct":22},{"key":27,"text":338,"correct":22},"2.5",{"key":30,"text":340,"correct":32},"3.0",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":30,"analysis":33},974879,"下列不属于风机运行噪声过大的故障原因是（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":22},"叶轮与机壳摩擦",{"key":24,"text":348,"correct":22},"轴承部件磨损，间隙过大",{"key":27,"text":350,"correct":22},"转速过高",{"key":30,"text":352,"correct":32},"叶片上附有不均匀的附着物",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":30,"analysis":33},974880,"下列不属于风机运行噪声过大故障的正确维修方法的是（ ）。",[357,359,361,363],{"key":20,"text":358,"correct":22},"查明叶轮与机壳摩擦原因，调整",{"key":24,"text":360,"correct":22},"更换或调整轴承部件",{"key":27,"text":362,"correct":22},"降低转速或更换风机",{"key":30,"text":364,"correct":32},"紧固定位螺栓或夹轮螺栓",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":33},974881,"下列不属于风阀不能自动启动的故障原因是（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":32},"管道内阀门未打开",{"key":24,"text":372,"correct":22},"控制模块或线路发生故障",{"key":27,"text":374,"correct":22},"未编写联动公式或联动公式错误",{"key":30,"text":376,"correct":22},"风阀发生故障",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":30,"analysis":33},974882,"下列不属于风机风量不足的维修方法的是（ ）。",[381,383,385,387],{"key":20,"text":382,"correct":22},"检查电源、轴承调换接线相序",{"key":24,"text":384,"correct":22},"更换匹配的风机",{"key":27,"text":386,"correct":22},"修复破损口或连接口，更换软连接",{"key":30,"text":388,"correct":32},"检查并打开被关闭的风口",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":30,"analysis":33},974883,"下列不属于现场手动不能正常启闭风阀的故障原因是（ ）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"执行器损坏",{"key":24,"text":396,"correct":22},"叶片转轴锈死",{"key":27,"text":398,"correct":22},"阀体内有异物，卡住叶片",{"key":30,"text":400,"correct":32},"自动复位型板式排烟口拉筋线松脱或断开",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":30,"analysis":33},974884,"下列不属于挡烟垂壁无法手动启动的故障原因是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":22},"控制器缺电",{"key":24,"text":408,"correct":22},"控制器内电气发生故障",{"key":27,"text":410,"correct":22},"驱动电机发生故障或缺电",{"key":30,"text":372,"correct":32},{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":27,"analysis":33},974885,"任一常闭风口开启时，风机不能自动启动，下列关于该故障的维修处理方法不正确的是（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"按要求设置或对连锁控制线路进行检修",{"key":24,"text":419,"correct":22},"将风机控制柜设置为“自动”状态",{"key":27,"text":421,"correct":32},"将风机控制柜设置为“手动”状态",{"key":30,"text":423,"correct":22},"排除风机及控制柜故障",{"id":425,"libraryId":5,"type":426,"typeLabel":427,"stem":428,"options":429,"answer":441,"analysis":33},974886,2,"多选题","下列属于更换消防电话系统、消防应急广播系统组件操作步骤的是（ ）。",[430,432,434,436,438],{"key":20,"text":431,"correct":32},"确定故障点位置",{"key":24,"text":433,"correct":32},"查找故障原因",{"key":27,"text":435,"correct":32},"更换组件",{"key":30,"text":437,"correct":32},"功能检查",{"key":439,"text":440,"correct":32},"E","维修记录","ABCDE",{"id":443,"libraryId":5,"type":426,"typeLabel":427,"stem":444,"options":445,"answer":441,"analysis":33},974887,"下列属于消防应急灯具、应急照明控制器和消防应急电源常见的故障有（ ）。",[446,448,450,452,454],{"key":20,"text":447,"correct":32},"光源故障",{"key":24,"text":449,"correct":32},"自带电源型灯具持续应急时间不满足设置场所要求",{"key":27,"text":451,"correct":32},"主电故障报警",{"key":30,"text":453,"correct":32},"备电故障报警",{"key":439,"text":455,"correct":32},"消防应急集中电源及消防应急灯具登录故障",{"id":457,"libraryId":5,"type":426,"typeLabel":427,"stem":458,"options":459,"answer":470,"analysis":33},974888,"系统应急启动后，蓄电池电源供电时持续工作时间应满足下列要求：（ ）。",[460,462,464,466,468],{"key":20,"text":461,"correct":32},"建筑高度为120m的办公建筑，不应少于1.5h",{"key":24,"text":463,"correct":32},"老年人照料设施不应少于1.0h",{"key":27,"text":465,"correct":22},"总建筑面积为20000m2的地下建筑不应少于1.0h",{"key":30,"text":467,"correct":22},"建筑高度100m的住宅建筑不应少于1.5h",{"key":439,"text":469,"correct":32},"医疗建筑不应少于1.0h","ABE",{"id":472,"libraryId":5,"type":426,"typeLabel":427,"stem":473,"options":474,"answer":485,"analysis":33},974889,"下列属于主电故障报警维修方法的是（ ）。",[475,477,479,481,483],{"key":20,"text":476,"correct":32},"检查输入电源是否完好，交流电源电压是否为180-250V",{"key":24,"text":478,"correct":32},"检查主电熔丝有无熔断，若已熔断，应更换满足要求的熔丝",{"key":27,"text":480,"correct":32},"检查接触是否不良等，若接线端子或接头松动，应重新连接紧固",{"key":30,"text":482,"correct":32},"若接头处有氧化或锈蚀痕迹，可断开接点用细砂纸磨掉或用电工刀刮掉氧化层，镀锡和涂抹凡士林后，再重新连接紧固",{"key":439,"text":484,"correct":22},"检查各种排线插头与插座是否接触不良，若插座的接触铜片已经失去弹性，应更换新的插座","ABCD",{"id":487,"libraryId":5,"type":426,"typeLabel":427,"stem":488,"options":489,"answer":498,"analysis":33},974890,"下列关于备电故障报警维修方法不正确的是（ ）。",[490,492,493,495,496],{"key":20,"text":491,"correct":32},"检查蓄电池是否有损坏，若已损坏，则更换符合要求的蓄电池",{"key":24,"text":482,"correct":22},{"key":27,"text":494,"correct":32},"检查蓄电池端子接线是否正确（黑色端子应接负极，红色端子应接正极）若接线错误，应按产品安装说明书要求重新接线",{"key":30,"text":484,"correct":22},{"key":439,"text":497,"correct":32},"查备电熔丝是否损坏，若已损坏，应更换新的满足要求的熔丝","ACE",{"id":500,"libraryId":5,"type":426,"typeLabel":427,"stem":501,"options":502,"answer":441,"analysis":33},974891,"下列属于手动按钮盒不能启动防火卷帘的故障原因是（ ）。",[503,505,507,509,511],{"key":20,"text":504,"correct":32},"电源发生故障",{"key":24,"text":506,"correct":32},"卷门机发生故障",{"key":27,"text":508,"correct":32},"行程开关断开",{"key":30,"text":510,"correct":32},"卷门机过热保护",{"key":439,"text":512,"correct":32},"卷帘被卡住",{"id":514,"libraryId":5,"type":426,"typeLabel":427,"stem":515,"options":516,"answer":525,"analysis":33},974892,"下列属于消防控制室无法联动控制防火卷帘故障原因的是（ ）。",[517,519,521,523,524],{"key":20,"text":518,"correct":32},"控制器发生故障",{"key":24,"text":520,"correct":32},"控制模块发生故障",{"key":27,"text":522,"correct":32},"联动控制线路发生故障",{"key":30,"text":504,"correct":22},{"key":439,"text":153,"correct":22},"ABC",{"id":527,"libraryId":5,"type":426,"typeLabel":427,"stem":528,"options":529,"answer":441,"analysis":33},974893,"下列属于防火卷帘只能单向运行的故障原因是（ ）。",[530,532,533,535,537],{"key":20,"text":531,"correct":32},"按钮损坏",{"key":24,"text":149,"correct":32},{"key":27,"text":534,"correct":32},"限位开关损坏或断线",{"key":30,"text":536,"correct":32},"接触器联锁动断触点问题",{"key":439,"text":153,"correct":32},{"id":539,"libraryId":5,"type":426,"typeLabel":427,"stem":540,"options":541,"answer":470,"analysis":33},974894,"下列属于消火栓无法打开的故障原因有（ ）。",[542,543,544,545,546],{"key":20,"text":218,"correct":32},{"key":24,"text":220,"correct":32},{"key":27,"text":231,"correct":22},{"key":30,"text":224,"correct":22},{"key":439,"text":222,"correct":32},{"id":548,"libraryId":5,"type":426,"typeLabel":427,"stem":549,"options":550,"answer":485,"analysis":33},974895,"下列属于消火栓无法打开的维修方法是（ ）。",[551,553,555,556,558],{"key":20,"text":552,"correct":32},"拆开维修",{"key":24,"text":554,"correct":32},"更换阀杆",{"key":27,"text":246,"correct":32},{"key":30,"text":557,"correct":32},"做好冬季防冻措施",{"key":439,"text":240,"correct":22},{"id":560,"libraryId":5,"type":426,"typeLabel":427,"stem":561,"options":562,"answer":441,"analysis":33},974896,"下列属于消火栓出水压力不足的故障原因是（ ）。",[563,565,567,569,571],{"key":20,"text":564,"correct":32},"临时高压系统消防水泵未启动",{"key":24,"text":566,"correct":32},"消防水泵出水管路阀门未完全开启",{"key":27,"text":568,"correct":32},"消防水泵试水管路阀门被误开启",{"key":30,"text":570,"correct":32},"出水管路泄压阀起跳泄水",{"key":439,"text":572,"correct":32},"设置的稳压设施压力设定不正确",{"id":574,"libraryId":5,"type":426,"typeLabel":427,"stem":575,"options":576,"answer":441,"analysis":33},974897,"下列属于消火栓出水压力不足的故障维修方法的是（ ）。",[577,579,581,583,585],{"key":20,"text":578,"correct":32},"逐段排查渗漏部位并予以维修",{"key":24,"text":580,"correct":32},"消防水泵如存在供电故障及时予以维修",{"key":27,"text":582,"correct":32},"关闭试水管路阀门",{"key":30,"text":584,"correct":32},"排查起跳原因，泄压阀损坏的，维修和更换",{"key":439,"text":586,"correct":32},"重新设定启停泵压力",{"id":588,"libraryId":5,"type":426,"typeLabel":427,"stem":589,"options":590,"answer":601,"analysis":33},974898,"下列属于室内消火栓系统给水管网振动大，发出异响、噪声的原因是（ ）。",[591,593,595,597,599],{"key":20,"text":592,"correct":32},"消火栓泵出口未采用柔性连接",{"key":24,"text":594,"correct":32},"管网支\u002F吊架松动",{"key":27,"text":596,"correct":22},"消火栓泵出口采用刚性连接",{"key":30,"text":598,"correct":32},"管网流速过快",{"key":439,"text":600,"correct":32},"管网未设置自动排气阀","ABDE",{"id":603,"libraryId":5,"type":426,"typeLabel":427,"stem":604,"options":605,"answer":616,"analysis":33},974899,"下列属于室内消火栓关闭时本体渗漏的故障原因是（ ）。",[606,608,610,612,614],{"key":20,"text":607,"correct":32},"阀瓣被异物卡住",{"key":24,"text":609,"correct":32},"消火栓手轮未旋转到位",{"key":27,"text":611,"correct":32},"阀体、阀座或阀瓣损伤",{"key":30,"text":613,"correct":22},"排水阀不畅",{"key":439,"text":615,"correct":32},"阀瓣密封圈失效","ABCE",{"id":618,"libraryId":5,"type":426,"typeLabel":427,"stem":619,"options":620,"answer":631,"analysis":33},974900,"下列属于室内消火栓关闭时本体渗漏的故障维修方法是（ ）。",[621,623,625,627,629],{"key":20,"text":622,"correct":32},"更换阀瓣密封圈",{"key":24,"text":624,"correct":32},"清除阀瓣异物，关严消火栓",{"key":27,"text":626,"correct":22},"对照设计文件检查管径大小，不符合要求的予以更换",{"key":30,"text":628,"correct":32},"对损伤部件进行维修或更换",{"key":439,"text":630,"correct":22},"更换阀盖密封","ABD",[633,636,639,642,645,648],{"id":15,"name":634,"category":7,"favorite":635},"领导干部任职前廉政法规知识测试题",92,{"id":637,"name":638,"category":7,"favorite":15},595,"建筑结构与设备",{"id":640,"name":641,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":643,"name":644,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":646,"name":647,"category":7,"favorite":8},534,"BIM工程师",{"id":649,"name":647,"category":7,"favorite":8},535]