[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-38":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":555},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,38,50,2486,[13,38,48,62,77,89,103,118,132,146,158,169,182,197,212,226,239,252,266,281,295,310,325,340,354,369,383,397,411,425,435,441,447,453,459,465,471,477,483,489,495,501,507,513,519,525,531,537,543,549],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},974799,2,"多选题","消防应急广播启动后现场音箱无音源输出的原因可能是（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","广播模块损坏或广播线路发生故障",true,{"key":24,"text":25,"correct":26},"B","广播控制器发生通信故障或担坏",false,{"key":28,"text":29,"correct":22},"C","扬声器损坏或扬声器发生线路故障",{"key":31,"text":32,"correct":26},"D","广播控制器音源文件丢失",{"key":34,"text":35,"correct":26},"E","功率放大器发生线路故障导致过载或损坏","AC","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":47,"analysis":37},974800,"消防应急广插无法应急启动的原因可能是（ ）。",[42,43,44,45,46],{"key":20,"text":25,"correct":22},{"key":24,"text":32,"correct":22},{"key":28,"text":35,"correct":22},{"key":31,"text":21,"correct":26},{"key":34,"text":29,"correct":26},"ABC",{"id":49,"libraryId":5,"type":15,"typeLabel":16,"stem":50,"options":51,"answer":47,"analysis":37},974801,"下列关于消防电话分机、消防电话插孔通话功能测试说法正确的是（ ）。",[52,54,56,58,60],{"key":20,"text":53,"correct":22},"检查消防电话分机、插孔与主机之间的呼叫与通话功能",{"key":24,"text":55,"correct":22},"检查消防电话主机应能显示每部分机或电话插孔的位置",{"key":28,"text":57,"correct":22},"检查呼叫铃声和通话语音应清晰",{"key":31,"text":59,"correct":26},"进行消防电话主机复位、自检、报警操作",{"key":34,"text":61,"correct":26},"观察3min，应处于正常监视状态",{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":76,"analysis":37},974802,"下列属于防火卷帘帘面运行时不能下放或下放速度过慢的故障原因是（ ）。",[66,68,70,72,74],{"key":20,"text":67,"correct":22},"导轨变形卡住帘面",{"key":24,"text":69,"correct":26},"电磁铁没接线",{"key":28,"text":71,"correct":22},"导轨上端弧形不够顶住帘面",{"key":31,"text":73,"correct":26},"门体与导轨卡住",{"key":34,"text":75,"correct":22},"帘面上防风钩变形顶住导轨","ACE",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":79,"options":80,"answer":88,"analysis":37},974803,"下列属于防火卷帘帘面不速放的原因是（ ）。",[81,82,83,84,86],{"key":20,"text":67,"correct":26},{"key":24,"text":69,"correct":22},{"key":28,"text":73,"correct":22},{"key":31,"text":85,"correct":22},"附件链条生锈",{"key":34,"text":87,"correct":26},"到会变形卡主帘面","BCD",{"id":90,"libraryId":5,"type":15,"typeLabel":16,"stem":91,"options":92,"answer":88,"analysis":37},974804,"下列属于防火卷帘运行时噪声大的维修方法是（ ）。",[93,95,97,99,101],{"key":20,"text":94,"correct":26},"检查导轨是否卡住",{"key":24,"text":96,"correct":22},"紧固五金件",{"key":28,"text":98,"correct":22},"调节帘面位置，保证导轨相互平行",{"key":31,"text":100,"correct":22},"加涂润滑油",{"key":34,"text":102,"correct":26},"检查导轨是否变形",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":117,"analysis":37},974805,"下列属于防火卷帘扬声器“嘟嘟”循环鸣叫，面板电源灯闪烁，故障灯常亮的维修方法是（ ）。",[107,109,111,113,115],{"key":20,"text":108,"correct":22},"检查三相开关是否打开",{"key":24,"text":110,"correct":22},"检查三相电输入是否正常",{"key":28,"text":112,"correct":26},"检查电源是否有故障",{"key":31,"text":114,"correct":22},"检查电路板上方并排的三个熔丝是否烧毁、漏装",{"key":34,"text":116,"correct":26},"检查控制器、控制模块及联动控制线，进行维修或报修","ABD",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":117,"analysis":37},974806,"下列属于防火卷帘配电箱跳闸的故障原因有（ ）。",[122,124,126,128,130],{"key":20,"text":123,"correct":22},"三相输入短路",{"key":24,"text":125,"correct":22},"三相输入零线、火线接反",{"key":28,"text":127,"correct":26},"三相开关未打开",{"key":31,"text":129,"correct":22},"零线、地线接反",{"key":34,"text":131,"correct":26},"缺相、断电",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":47,"analysis":37},974807,"下列属于防火门启闭过程不灵活，有卡滞的故障原因是（ ）。",[136,138,140,142,144],{"key":20,"text":137,"correct":22},"铰链等转（传）动部件变形",{"key":24,"text":139,"correct":22},"铰链等转（传）动部件缺少润滑",{"key":28,"text":141,"correct":22},"门扇与地面局部产生摩擦",{"key":31,"text":143,"correct":26},"未涂覆润滑油",{"key":34,"text":145,"correct":26},"闭门器拉力调节不当",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":88,"analysis":37},974808,"下列属于防火门关闭缓慢或过速，双扇门关闭不严的故障原因是（ ）。",[150,151,152,154,156],{"key":20,"text":141,"correct":26},{"key":24,"text":145,"correct":22},{"key":28,"text":153,"correct":22},"双扇门顺序器损坏",{"key":31,"text":155,"correct":22},"门扇变形",{"key":34,"text":157,"correct":26},"闭门器主体装反",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":88,"analysis":37},974809,"下列属于防火门门扇无法开启的故障原因是（ ）。",[162,163,164,166,168],{"key":20,"text":145,"correct":26},{"key":24,"text":157,"correct":22},{"key":28,"text":165,"correct":22},"闭门器损坏",{"key":31,"text":167,"correct":22},"连杆上的螺钉挡住门扇",{"key":34,"text":153,"correct":26},{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":47,"analysis":37},974810,"下列属于防火门关闭后挡烟性能差的故障原因是（ ）。",[173,175,177,179,180],{"key":20,"text":174,"correct":22},"防火门与建筑框架间存在缝隙",{"key":24,"text":176,"correct":22},"防火门密封条安装不到位",{"key":28,"text":178,"correct":22},"防火门密封条膨胀系数不符合要求",{"key":31,"text":165,"correct":26},{"key":34,"text":181,"correct":26},"饺链等转（传）动部件变形",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":196,"analysis":37},974811,"下列属于防火门关闭后挡烟性能差的维修方法是（ ）。",[186,188,190,192,194],{"key":20,"text":187,"correct":22},"用不燃材料填充缝隙和孔洞，并达到耐火极限要求",{"key":24,"text":189,"correct":26},"检查并调整连杆上的螺钉",{"key":28,"text":191,"correct":22},"更换符合要求的密封条",{"key":31,"text":193,"correct":22},"重新安装防火门密封条",{"key":34,"text":195,"correct":26},"更换滑槽","ACD",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":211,"analysis":37},974812,"下列属于防火门监控器不报警的故障原因是（ ）。",[201,203,205,207,209],{"key":20,"text":202,"correct":22},"电源发生故障",{"key":24,"text":204,"correct":22},"线路发生故障",{"key":28,"text":206,"correct":22},"控制板损坏",{"key":31,"text":208,"correct":22},"声响部件损坏",{"key":34,"text":210,"correct":26},"防火门监控器损坏","ABCD",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":196,"analysis":37},974813,"下列属于常开式防火门无法锁定在开启状态的故障原因是（ ）。",[216,218,220,222,224],{"key":20,"text":217,"correct":22},"无DC24V电压",{"key":24,"text":219,"correct":26},"电动闭门器滑槽内锁舌过紧",{"key":28,"text":221,"correct":22},"防火门监控模块损坏",{"key":31,"text":223,"correct":22},"电动闭门器滑槽内锁舌损坏",{"key":34,"text":225,"correct":26},"电磁释放器无法消磁",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":238,"analysis":37},974814,"下列属于常开式防火门无法正常关闭的故障原因是（ ）。",[230,231,232,234,236],{"key":20,"text":225,"correct":22},{"key":24,"text":219,"correct":22},{"key":28,"text":233,"correct":22},"模块损坏或无联动公式",{"key":31,"text":235,"correct":22},"闭门器、连杆安装角度不正确",{"key":34,"text":237,"correct":22},"防火门监控器发生故障","ABCDE",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":211,"analysis":37},974815,"下列属于防火门关闭后无法反馈信息的故障原因是（ ）。",[243,245,247,249,251],{"key":20,"text":244,"correct":22},"电动闭门器滑槽内的信号反馈装置调试不到位或损坏",{"key":24,"text":246,"correct":22},"未安装门磁开关或门磁开关损坏",{"key":28,"text":248,"correct":22},"接线不正确",{"key":31,"text":250,"correct":22},"监控模块损坏",{"key":34,"text":219,"correct":26},{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":88,"analysis":37},974817,"下列属于推车式灭火器和手提式灭火器都有的常见的故障包括（ ）。",[256,258,260,262,264],{"key":20,"text":257,"correct":26},"喷嘴连接松动",{"key":24,"text":259,"correct":22},"灭火器贴花标志上生产商名称、地址和电话模糊不清",{"key":28,"text":261,"correct":22},"保险装置和封记损坏",{"key":31,"text":263,"correct":22},"喷射软管连接松动",{"key":34,"text":265,"correct":26},"喷射控制枪阀门开关不灵活",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":280,"analysis":37},974818,"下列属于推车式灭火器的常见故障是（ ）。",[270,272,274,276,278],{"key":20,"text":271,"correct":22},"喷射控制枪阀门开关不灵活或损坏",{"key":24,"text":273,"correct":22},"喷射控制枪存在明显变形、裂纹",{"key":28,"text":275,"correct":22},"车轮和车架部件有明显损伤，不能推（拉）自如",{"key":31,"text":277,"correct":26},"喷嘴存在明显变形、破裂或连接松动",{"key":34,"text":279,"correct":22},"喷射软管组件存在龟裂、脱落或连接松动","ABCE",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":238,"analysis":37},974819,"下列属于灭火器维修工作的是（ ）。",[285,287,289,291,293],{"key":20,"text":286,"correct":22},"原始信息记录",{"key":24,"text":288,"correct":22},"维修前检查",{"key":28,"text":290,"correct":22},"拆卸灭火器",{"key":31,"text":292,"correct":22},"灭火剂回收处置",{"key":34,"text":294,"correct":22},"零部件更换",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":309,"analysis":37},974820,"下列属于每次维修必须更换的零部件有（ ）。",[299,301,303,305,307],{"key":20,"text":300,"correct":26},"喷射软管",{"key":24,"text":302,"correct":22},"水基型灭火剂",{"key":28,"text":304,"correct":26},"喷嘴",{"key":31,"text":306,"correct":26},"虹吸管",{"key":34,"text":308,"correct":22},"灭火器上的密封片、圈、垫等密封零件","BE",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":324,"analysis":37},974821,"对外观目测判断，下列情况应报废的有（ ）。",[314,316,318,320,322],{"key":20,"text":315,"correct":22},"铭牌标志脱落",{"key":24,"text":317,"correct":22},"瓶体被火烧过",{"key":28,"text":319,"correct":26},"瓶体外部涂层脱落面积大于气瓶总面积的1\u002F4",{"key":31,"text":321,"correct":22},"由不合法的维修机构维修过",{"key":34,"text":323,"correct":22},"瓶体外表面、连接部位、底座等有腐蚀的凹坑","ABDE",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":339,"analysis":37},974822,"下列关于灭火器维修充装的注意事项说法正确的有（ ）。",[329,331,333,335,337],{"key":20,"text":330,"correct":22},"在拆卸灭火器瓶头阀门前一定要先卸压，待余气排放完毕，才能完全旋开连接螺纹，拆卸时不能将阀门顶部对准人体",{"key":24,"text":332,"correct":22},"受压零部件应逐个进行水压试验",{"key":28,"text":334,"correct":26},"零部件更换应采用原灭火器生产企业提供的零部件",{"key":31,"text":336,"correct":26},"灭火器瓶体损伤可进行更换",{"key":34,"text":338,"correct":22},"灌装不同型号的水基型灭火剂时，应用清水将灌装设备的容器和管道清洗干净","ABE",{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":211,"analysis":37},974823,"下列属于现场手动不能正常启闭风阀的故障原因有（ ）。",[344,346,348,350,352],{"key":20,"text":345,"correct":22},"执行器损坏",{"key":24,"text":347,"correct":22},"叶片转轴锈死",{"key":28,"text":349,"correct":22},"阀体内有异物，卡住叶片",{"key":31,"text":351,"correct":22},"非自动复位型板式排烟口拉筋线松脱或断开",{"key":34,"text":353,"correct":26},"控制模块发生故障",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":368,"analysis":37},974824,"下列属于现场不能手动启闭风机的故障原因有（ ）。",[358,360,362,364,366],{"key":20,"text":359,"correct":26},"风机控制柜处于“手动”状态",{"key":24,"text":361,"correct":22},"控制柜未送电",{"key":28,"text":363,"correct":22},"控制柜内电气发生故障",{"key":31,"text":365,"correct":26},"未按要求设置连锁控制线路或控制线路发生故障",{"key":34,"text":367,"correct":22},"风机电动机发生故障","BCE",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":211,"analysis":37},974825,"下列属于总线控制盘不能远程手动启动风阀（不包括未设电动开启功能的排烟防火阀）故障维修方法的是（ ）。",[373,375,377,379,381],{"key":20,"text":374,"correct":22},"消防联动控制调整到“手动允许”状态",{"key":24,"text":376,"correct":22},"更换控制模块或检修线路",{"key":28,"text":378,"correct":22},"维修或更换键盘板",{"key":31,"text":380,"correct":22},"排除风阀故障",{"key":34,"text":382,"correct":26},"检查触发信号，满足与逻辑",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":339,"analysis":37},974826,"下列属于风机不能自动启动故障的解决方法是（ ）。",[387,389,391,393,395],{"key":20,"text":388,"correct":22},"消防联动控制器调整为“自动允许”状态",{"key":24,"text":390,"correct":22},"将风机控制柜设置为“自动”状态",{"key":28,"text":392,"correct":26},"将多线控制盘解锁为“手动允许”状态",{"key":31,"text":394,"correct":26},"风机控制柜调整为“手动”状态",{"key":34,"text":396,"correct":22},"排除风机及控制柜故障",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":47,"analysis":37},974827,"下列属于风机运行噪声过大的故障维修方法是（ ）。",[401,403,405,407,409],{"key":20,"text":402,"correct":22},"查明叶轮与机壳摩擦原因，调整",{"key":24,"text":404,"correct":22},"更换或调整轴承部件",{"key":28,"text":406,"correct":22},"降低转速或更换风机",{"key":31,"text":408,"correct":26},"紧固定位螺栓或夹轮螺栓",{"key":34,"text":410,"correct":26},"叶轮变形或不平衡",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":238,"analysis":37},974828,"下列关于风机风量不足的维修方法正确的是（ ）。",[415,417,419,421,423],{"key":20,"text":416,"correct":22},"打开阀门",{"key":24,"text":418,"correct":22},"调节阀门到合适的开度",{"key":28,"text":420,"correct":22},"调整带轮中心距，张紧传动带或更换传动带",{"key":31,"text":422,"correct":22},"检查并关闭被误开的风口",{"key":34,"text":424,"correct":22},"检查电源、轴承，调换接线相序",{"id":426,"libraryId":5,"type":427,"typeLabel":428,"stem":429,"options":430,"answer":434,"analysis":37},974829,3,"判断题","检查输入电源是否完好，交流电源电压是否为180～220V，检查主电熔丝有无熔断，若已熔断，应更换满足要求的熔丝，属于主电故障的一种维修方法。",[431,433],{"key":20,"text":432,"correct":26},"正确",{"key":24,"text":434,"correct":22},"错误",{"id":436,"libraryId":5,"type":427,"typeLabel":428,"stem":437,"options":438,"answer":434,"analysis":37},974830,"消防应急灯具无法正常登录时，检查灯具总线是否接好，测量电压（要求在24～36V）",[439,440],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":442,"libraryId":5,"type":427,"typeLabel":428,"stem":443,"options":444,"answer":434,"analysis":37},974831,"手动按钮盒不能启动防火卷帘，一定是电源发生故障或卷门机发生故障。",[445,446],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":448,"libraryId":5,"type":427,"typeLabel":428,"stem":449,"options":450,"answer":434,"analysis":37},974832,"消防控制室无法联动控制防火卷帘，可能是联动控制设备的控制模式未设定在“自动”状态。",[451,452],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":454,"libraryId":5,"type":427,"typeLabel":428,"stem":455,"options":456,"answer":434,"analysis":37},974833,"防火卷帘升降不到位，要留意限位开关是否损坏或断线。",[457,458],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":460,"libraryId":5,"type":427,"typeLabel":428,"stem":461,"options":462,"answer":432,"analysis":37},974834,"若限位开关损坏或断线，防火卷帘只能单向运行。",[463,464],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":466,"libraryId":5,"type":427,"typeLabel":428,"stem":467,"options":468,"answer":432,"analysis":37},974835,"导轨变形卡住帘面，防火卷帘帘面运行时不能下放或下放速度过慢。",[469,470],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":472,"libraryId":5,"type":427,"typeLabel":428,"stem":473,"options":474,"answer":434,"analysis":37},974836,"防火卷帘帘面运行时不能下放或下放速度过慢，考虑接触器触头及线圈问题。",[475,476],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":478,"libraryId":5,"type":427,"typeLabel":428,"stem":479,"options":480,"answer":434,"analysis":37},974837,"防火卷帘帘面不速放，要检查导轨、防风钩是否变形并维修。",[481,482],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":484,"libraryId":5,"type":427,"typeLabel":428,"stem":485,"options":486,"answer":434,"analysis":37},974838,"防火卷帘运行时噪声大，可能是门体与导轨被卡住。",[487,488],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":490,"libraryId":5,"type":427,"typeLabel":428,"stem":491,"options":492,"answer":432,"analysis":37},974839,"防火卷帘未涂覆润滑油，运行时噪声比较大。",[493,494],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":496,"libraryId":5,"type":427,"typeLabel":428,"stem":497,"options":498,"answer":434,"analysis":37},974840,"防火卷帘控制器面板灯不亮，可能是帘面走位。",[499,500],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":502,"libraryId":5,"type":427,"typeLabel":428,"stem":503,"options":504,"answer":432,"analysis":37},974841,"扬声器“嘟嘟”循环鸣叫，面板电源灯闪烁，故障灯常亮，考虑缺相、断电。",[505,506],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":508,"libraryId":5,"type":427,"typeLabel":428,"stem":509,"options":510,"answer":434,"analysis":37},974842,"防火卷帘电池灯不亮，考虑缺相、断电。",[511,512],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":514,"libraryId":5,"type":427,"typeLabel":428,"stem":515,"options":516,"answer":432,"analysis":37},974843,"防火门启闭过程不灵活，有卡滞，可能是铰链等转（传）动部件变形或缺少润滑。",[517,518],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":520,"libraryId":5,"type":427,"typeLabel":428,"stem":521,"options":522,"answer":432,"analysis":37},974844,"双扇门顺序器损坏也会导致防火门关闭缓慢或过速，双扇门关闭不严。",[523,524],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":526,"libraryId":5,"type":427,"typeLabel":428,"stem":527,"options":528,"answer":434,"analysis":37},974845,"闭门器主体安装时，推面安装调速阀应朝向铰链，拉面安装则相反。",[529,530],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":532,"libraryId":5,"type":427,"typeLabel":428,"stem":533,"options":534,"answer":432,"analysis":37},974846,"监控模块损坏会发生常开式防火门无法正常关闭、常开式防火门无法锁定在开启状态、防火门关闭后无法反馈信息等故障。",[535,536],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":538,"libraryId":5,"type":427,"typeLabel":428,"stem":539,"options":540,"answer":432,"analysis":37},974847,"无DC24V电压或电压过低会导致常开式防火门无法锁定在开启状态。",[541,542],{"key":20,"text":432,"correct":22},{"key":24,"text":434,"correct":26},{"id":544,"libraryId":5,"type":427,"typeLabel":428,"stem":545,"options":546,"answer":434,"analysis":37},974848,"电动闭门器滑槽内锁舌过紧或位置不当致防火门开启角度过大会导致常开式防火门无法锁定在开启状态。",[547,548],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},{"id":550,"libraryId":5,"type":427,"typeLabel":428,"stem":551,"options":552,"answer":434,"analysis":37},974850,"设有温感器的风阀，温感器损坏脱落，下次风阀不能自动启动。",[553,554],{"key":20,"text":432,"correct":26},{"key":24,"text":434,"correct":22},[556,560,563,566,569,572],{"id":557,"name":558,"category":7,"favorite":559},1,"领导干部任职前廉政法规知识测试题",92,{"id":561,"name":562,"category":7,"favorite":557},595,"建筑结构与设备",{"id":564,"name":565,"category":7,"favorite":557},715,"招标采购专业知识与法律法规",{"id":567,"name":568,"category":7,"favorite":557},848,"市政方向-通用基础",{"id":570,"name":571,"category":7,"favorite":8},534,"BIM工程师",{"id":573,"name":571,"category":7,"favorite":8},535]