[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-37":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":568},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,37,50,2486,[13,28,34,40,46,52,58,78,92,104,116,128,140,151,162,173,185,196,207,218,229,240,252,264,276,288,299,310,322,334,346,354,362,370,382,394,406,418,430,442,452,464,476,488,498,509,521,532,543,554],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},974749,3,"判断题","压力表损坏或压力表进水管路堵塞会导致湿式报警阀阀前阀后压力表显示不同。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},974750,"湿式报警阀开启后报警管路不排水是因为湿式报警阀损坏且补偿管路堵塞。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},974751,"报警液位设定不准确可能会造成消防水池（水箱）液位报警。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},974752,"消防水泵结合器漏水，可能是止回阀被砂石等异物卡住，应逆水流方向，利用高压水冲洗止回阀，或拆开止回阀清理后装回。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":25,"analysis":27},974753,"湿式报警阀组漏水一般是因为排水阀门未完全关闭或者阀瓣密封垫老化或损坏。",[50,51],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},974754,"湿式报警阀阀后压力表显示正常，但阀前压力表显示无压力或水压不足，有可能是高位消防水箱无水。",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":60,"typeLabel":61,"stem":62,"options":63,"answer":77,"analysis":27},974755,2,"多选题","下列关于喷头类型的性能代号表达正确的是（ ）。",[64,66,68,71,74],{"key":20,"text":65,"correct":22},"直立边墙型喷头：ZSTBZ",{"key":24,"text":67,"correct":22},"水平边墙型喷头：ZSTBS",{"key":69,"text":70,"correct":26},"C","下垂边墙型喷头：ZSTBP",{"key":72,"text":73,"correct":26},"D","通用边墙型喷头：ZSTBX",{"key":75,"text":76,"correct":22},"E","齐平式喷头：ZSTDQ","ABE",{"id":79,"libraryId":5,"type":80,"typeLabel":81,"stem":82,"options":83,"answer":24,"analysis":27},974756,1,"单选题","总建筑面积大于20000m2的地下、半地下建筑应急照明系统应急启动后，自带电源型灯具蓄电池电源供电时持续工作时间不应少于（ ）h。",[84,86,88,90],{"key":20,"text":85,"correct":26},"0.5",{"key":24,"text":87,"correct":22},"1.0",{"key":69,"text":89,"correct":26},"1.5",{"key":72,"text":91,"correct":26},"2.0",{"id":93,"libraryId":5,"type":80,"typeLabel":81,"stem":94,"options":95,"answer":24,"analysis":27},974757,"下列关于集中型应急照明控制器应急电源开机无显示的故障维修办法不正确的是（ ）。",[96,98,100,102],{"key":20,"text":97,"correct":26},"检查各种排线插头与插座是否接触不良",{"key":24,"text":99,"correct":22},"利用万用表检查消防应急灯具的供电线路是否存在断路或者供电电压过低等问题",{"key":69,"text":101,"correct":26},"查看熔丝是否熔断，若已熔断，应更换新的满足要求的熔丝",{"key":72,"text":103,"correct":26},"检查主、备电源输出是否正常",{"id":105,"libraryId":5,"type":80,"typeLabel":81,"stem":106,"options":107,"answer":72,"analysis":27},974758,"下列关于消防应急灯具线路对地绝缘阻值的说法正确的是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":26},"应大于2.0MΩ",{"key":24,"text":111,"correct":26},"应大于5.0MΩ",{"key":69,"text":113,"correct":26},"应大于10.0MΩ",{"key":72,"text":115,"correct":22},"应大于20.0MΩ",{"id":117,"libraryId":5,"type":80,"typeLabel":81,"stem":118,"options":119,"answer":72,"analysis":27},974759,"下列不属于手动按钮盒不能启动防火卷帘的故障描述是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":26},"电源发生故障",{"key":24,"text":123,"correct":26},"卷门机发生故障",{"key":69,"text":125,"correct":26},"手动按钮开关断路",{"key":72,"text":127,"correct":22},"控制模块发生故障",{"id":129,"libraryId":5,"type":80,"typeLabel":81,"stem":130,"options":131,"answer":69,"analysis":27},974760,"下列不属于解决手动按钮盒不能启动防火卷帘故障问题的是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":26},"检查主电源、控制电源、电动机，重新设置或维修、更换",{"key":24,"text":135,"correct":26},"检查手动按钮开关、行程开关，重新设置或维修、更换",{"key":69,"text":137,"correct":22},"重新调整行程开关位置",{"key":72,"text":139,"correct":26},"检查卷帘市面、帘座、导轨，矫正变形，清除异物",{"id":141,"libraryId":5,"type":80,"typeLabel":81,"stem":142,"options":143,"answer":72,"analysis":27},974761,"下列不属于消防控制室无法联动控制防火卷帘的原因是（ ）",[144,146,147,149],{"key":20,"text":145,"correct":26},"控制器发生故障",{"key":24,"text":127,"correct":26},{"key":69,"text":148,"correct":26},"联动控制线路发生故障",{"key":72,"text":150,"correct":22},"按钮损坏",{"id":152,"libraryId":5,"type":80,"typeLabel":81,"stem":153,"options":154,"answer":72,"analysis":27},974762,"下列不属于防火卷帘只能单向运行的故障原因是（ ）。",[155,156,158,160],{"key":20,"text":150,"correct":26},{"key":24,"text":157,"correct":26},"接触器触头及线圈问题",{"key":69,"text":159,"correct":26},"限位开关损坏或断线",{"key":72,"text":161,"correct":22},"行程开关调节不准确",{"id":163,"libraryId":5,"type":80,"typeLabel":81,"stem":164,"options":165,"answer":24,"analysis":27},974763,"下列不属于防火卷帘帘面运行时不能下放或下放速度过慢的原因是（ ）。",[166,168,169,171],{"key":20,"text":167,"correct":26},"导轨变形卡住帘面",{"key":24,"text":161,"correct":22},{"key":69,"text":170,"correct":26},"导轨上端弧形不够顶住帘面",{"key":72,"text":172,"correct":26},"帘面上防风钩变形顶住导轨",{"id":174,"libraryId":5,"type":80,"typeLabel":81,"stem":175,"options":176,"answer":69,"analysis":27},974764,"下列不属于防火门启闭过程不灵活，有卡滞故障维修方法的是（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":26},"润滑或更换转（传）动部件",{"key":24,"text":180,"correct":26},"检查门扇下框和地面，清除异物",{"key":69,"text":182,"correct":22},"重新调节闭门器",{"key":72,"text":184,"correct":26},"门扇与地面局部产生摩擦",{"id":186,"libraryId":5,"type":80,"typeLabel":81,"stem":187,"options":188,"answer":20,"analysis":27},974765,"下列不属于防火门关闭缓慢或过速，双扇门关闭不严故障原因的是（ ）。",[189,190,192,194],{"key":20,"text":184,"correct":22},{"key":24,"text":191,"correct":26},"闭门器拉力调节不当",{"key":69,"text":193,"correct":26},"双扇门顺序器损坏",{"key":72,"text":195,"correct":26},"门扇变形",{"id":197,"libraryId":5,"type":80,"typeLabel":81,"stem":198,"options":199,"answer":20,"analysis":27},974766,"下列不属于防火门门扇无法开启的原因是（ ）。",[200,201,203,205],{"key":20,"text":195,"correct":22},{"key":24,"text":202,"correct":26},"闭门器主体装反",{"key":69,"text":204,"correct":26},"闭门器损坏",{"key":72,"text":206,"correct":26},"连杆上的螺钉挡住门扇",{"id":208,"libraryId":5,"type":80,"typeLabel":81,"stem":209,"options":210,"answer":72,"analysis":27},974767,"下列不属于防火门关闭后挡烟性能差的原因是（ ）。",[211,213,215,217],{"key":20,"text":212,"correct":26},"防火门与建筑框架间存在缝隙",{"key":24,"text":214,"correct":26},"防火门密封条安装不到位",{"key":69,"text":216,"correct":26},"防火门密封条膨胀系数不符合要求",{"key":72,"text":195,"correct":22},{"id":219,"libraryId":5,"type":80,"typeLabel":81,"stem":220,"options":221,"answer":72,"analysis":27},974768,"下列不属于防火门监控器不报警的原因是（ ）。",[222,223,225,227],{"key":20,"text":121,"correct":26},{"key":24,"text":224,"correct":26},"线路发生故障",{"key":69,"text":226,"correct":26},"控制板损坏或声响部件损坏",{"key":72,"text":228,"correct":22},"主板发生故障",{"id":230,"libraryId":5,"type":80,"typeLabel":81,"stem":231,"options":232,"answer":20,"analysis":27},974769,"下列不属于常开式防火门无法锁定在开启状态的原因是（ ）。",[233,234,236,238],{"key":20,"text":228,"correct":22},{"key":24,"text":235,"correct":26},"无DC24V电压或电压过低",{"key":69,"text":237,"correct":26},"防火门监控模块损坏",{"key":72,"text":239,"correct":26},"电动闭门器滑槽内锁舌损坏",{"id":241,"libraryId":5,"type":80,"typeLabel":81,"stem":242,"options":243,"answer":69,"analysis":27},974770,"干式消火栓系统的充水时间不应大于（ ），在供水干管上宜设干式报警阀、雨淋阀或电磁阀、电动阀等快速启闭装置。",[244,246,248,250],{"key":20,"text":245,"correct":26},"1min",{"key":24,"text":247,"correct":26},"3min",{"key":69,"text":249,"correct":22},"5min",{"key":72,"text":251,"correct":26},"10min",{"id":253,"libraryId":5,"type":80,"typeLabel":81,"stem":254,"options":255,"answer":20,"analysis":27},974771,"下列不属于消火栓出水口平时有水渗出的故障原因是（ ）。",[256,258,260,262],{"key":20,"text":257,"correct":22},"消防水泵出水管路阀门未完全开启",{"key":24,"text":259,"correct":26},"消火栓未关严",{"key":69,"text":261,"correct":26},"阀瓣处有异物卡住无法关严",{"key":72,"text":263,"correct":26},"阀瓣橡胶垫老化",{"id":265,"libraryId":5,"type":80,"typeLabel":81,"stem":266,"options":267,"answer":20,"analysis":27},974772,"下列不是室内消火栓系统给水管网振动大，发出异响、噪声的是（ ）。",[268,270,272,274],{"key":20,"text":269,"correct":22},"消火栓泵出口未采用钢性连接",{"key":24,"text":271,"correct":26},"管网支\u002F吊架松动",{"key":69,"text":273,"correct":26},"管网未设置自动排气阀",{"key":72,"text":275,"correct":26},"管网流速过快",{"id":277,"libraryId":5,"type":80,"typeLabel":81,"stem":278,"options":279,"answer":69,"analysis":27},974773,"下列不是室内消火栓关闭时本体渗漏的原因是（ ）。",[280,282,284,286],{"key":20,"text":281,"correct":26},"阀瓣密封圈失效",{"key":24,"text":283,"correct":26},"消火栓手轮未旋转到位",{"key":69,"text":285,"correct":22},"系统管路分段控制阀被误关闭",{"key":72,"text":287,"correct":26},"阀瓣被异物卡住，造成消火栓末关严",{"id":289,"libraryId":5,"type":80,"typeLabel":81,"stem":290,"options":291,"answer":69,"analysis":27},974774,"下列不属于水枪或软管卷盘喷嘴处无水或压力不足的原因是（ ）。",[292,294,296,297],{"key":20,"text":293,"correct":26},"室内消火栓进水管检修阀被误关闭",{"key":24,"text":295,"correct":26},"系统管网水压不足",{"key":69,"text":283,"correct":22},{"key":72,"text":298,"correct":26},"水带与消火栓、水带与水枪连接未到位或接口损伤、变形",{"id":300,"libraryId":5,"type":80,"typeLabel":81,"stem":301,"options":302,"answer":24,"analysis":27},974775,"下列不属于稳压装置不能稳压的原因是（ ）。",[303,305,306,308],{"key":20,"text":304,"correct":26},"气压罐漏气严重",{"key":24,"text":281,"correct":22},{"key":69,"text":307,"correct":26},"稳压泵进水管阀门被误关闭",{"key":72,"text":309,"correct":26},"压力开关设定不正确",{"id":311,"libraryId":5,"type":80,"typeLabel":81,"stem":312,"options":313,"answer":24,"analysis":27},974776,"下列不属于推车贮压式水基型灭火器的组成部分的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":26},"喷嘴软管",{"key":24,"text":317,"correct":22},"阀门压把",{"key":69,"text":319,"correct":26},"阀门开启手柄",{"key":72,"text":321,"correct":26},"喷射控制枪及喷嘴",{"id":323,"libraryId":5,"type":80,"typeLabel":81,"stem":324,"options":325,"answer":20,"analysis":27},974777,"干粉灭火器压力指示器的标识为（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"F",{"key":24,"text":329,"correct":26},"M",{"key":69,"text":331,"correct":26},"S",{"key":72,"text":333,"correct":26},"T",{"id":335,"libraryId":5,"type":80,"typeLabel":81,"stem":336,"options":337,"answer":20,"analysis":27},974778,"手提式水基型灭火器超过出厂期满（ ）年需要维修。",[338,340,342,344],{"key":20,"text":339,"correct":22},"3",{"key":24,"text":341,"correct":26},"5",{"key":69,"text":343,"correct":26},"6",{"key":72,"text":345,"correct":26},"10",{"id":347,"libraryId":5,"type":80,"typeLabel":81,"stem":348,"options":349,"answer":24,"analysis":27},974779,"干粉型灭火器出厂期满（ ）年首次维修，首次维修以后每2年维修。",[350,351,352,353],{"key":20,"text":339,"correct":26},{"key":24,"text":341,"correct":22},{"key":69,"text":343,"correct":26},{"key":72,"text":345,"correct":26},{"id":355,"libraryId":5,"type":80,"typeLabel":81,"stem":356,"options":357,"answer":69,"analysis":27},974780,"手提式水基型灭火器超过出厂时间（ ）年报废。",[358,359,360,361],{"key":20,"text":339,"correct":26},{"key":24,"text":341,"correct":26},{"key":69,"text":343,"correct":22},{"key":72,"text":345,"correct":26},{"id":363,"libraryId":5,"type":80,"typeLabel":81,"stem":364,"options":365,"answer":72,"analysis":27},974781,"手提式干粉型灭火器超过出厂时间（ ）年报废。",[366,367,368,369],{"key":20,"text":339,"correct":26},{"key":24,"text":341,"correct":26},{"key":69,"text":343,"correct":26},{"key":72,"text":345,"correct":22},{"id":371,"libraryId":5,"type":80,"typeLabel":81,"stem":372,"options":373,"answer":69,"analysis":27},974782,"下列不属于手提式灭火器故障原因的是（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":26},"灭火器已被开启",{"key":24,"text":377,"correct":26},"阀门开启机构存在损伤",{"key":69,"text":379,"correct":22},"压力指示器指示在绿色区域范围",{"key":72,"text":381,"correct":26},"喷射软管组件存在龟裂、脱落或连接松动",{"id":383,"libraryId":5,"type":80,"typeLabel":81,"stem":384,"options":385,"answer":72,"analysis":27},974783,"下列不属于推车式灭火器常见故障的是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":26},"喷射控制枪阀门开关不灵活或损坏",{"key":24,"text":389,"correct":26},"喷射控制枪存在明显变形、裂纹",{"key":69,"text":391,"correct":26},"车轮和车架部件有明显损伤，不能推（拉）自如",{"key":72,"text":393,"correct":22},"喷嘴存在明显变形、破裂或连接松动",{"id":395,"libraryId":5,"type":80,"typeLabel":81,"stem":396,"options":397,"answer":72,"analysis":27},974784,"下列关于防火阀的启动方式说法不正确的是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":26},"电动启动",{"key":24,"text":401,"correct":26},"手动启动",{"key":69,"text":403,"correct":26},"温控启动",{"key":72,"text":405,"correct":22},"控制室远程控制",{"id":407,"libraryId":5,"type":80,"typeLabel":81,"stem":408,"options":409,"answer":20,"analysis":27},974785,"下列不属于现场不能手动启停风机的故障原因是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"风机的控制柜处于“手动”状态",{"key":24,"text":413,"correct":26},"控制柜未送电",{"key":69,"text":415,"correct":26},"控制柜内电气发生故障",{"key":72,"text":417,"correct":26},"风机电动机发生故障",{"id":419,"libraryId":5,"type":80,"typeLabel":81,"stem":420,"options":421,"answer":72,"analysis":27},974786,"下列不属于消防控制室不能远程手动启停风机的故障原因是（ ）。",[422,424,426,428],{"key":20,"text":423,"correct":26},"与多线控制盘配套用的切换模块损坏",{"key":24,"text":425,"correct":26},"多线控制盘未解锁处于“手动禁止”状态",{"key":69,"text":427,"correct":26},"风机控制柜处于“手动”状态",{"key":72,"text":429,"correct":22},"风机的控制柜未处于“手动”状态",{"id":431,"libraryId":5,"type":80,"typeLabel":81,"stem":432,"options":433,"answer":69,"analysis":27},974787,"下列不属于风机不能自动启动故障的正确维修方法的是（ ）。",[434,436,438,440],{"key":20,"text":435,"correct":26},"消防联动控制器调整为“自动允许”状态",{"key":24,"text":437,"correct":26},"将风机控制柜设置为“自动”状态",{"key":69,"text":439,"correct":22},"将多线控制盘解锁为“手动允许”状态",{"key":72,"text":441,"correct":26},"对损坏模块进行更换",{"id":443,"libraryId":5,"type":80,"typeLabel":81,"stem":444,"options":445,"answer":72,"analysis":27},974788,"下列不属于风机不能自动启动的故障原因是（ ）。",[446,448,449,450],{"key":20,"text":447,"correct":26},"消防联动控制器处于“自动禁止”状态",{"key":24,"text":148,"correct":26},{"key":69,"text":427,"correct":26},{"key":72,"text":451,"correct":22},"多线控制盘未解锁处于\"手动禁止“状态",{"id":453,"libraryId":5,"type":80,"typeLabel":81,"stem":454,"options":455,"answer":24,"analysis":27},974789,"下列不属于现场手动不能正常启闭风阀故障的正确维修方法的是（ ）。",[456,458,460,462],{"key":20,"text":457,"correct":26},"维修或更换执行器",{"key":24,"text":459,"correct":22},"对转轴喷润滑油脂",{"key":69,"text":461,"correct":26},"拆除并清除异物后重新安装",{"key":72,"text":463,"correct":26},"检查排烟口拉筋线并进行维修或更换",{"id":465,"libraryId":5,"type":80,"typeLabel":81,"stem":466,"options":467,"answer":69,"analysis":27},974790,"下列属于风阀不能自动启动故障的正确维修方法的是（ ）。",[468,470,472,474],{"key":20,"text":469,"correct":26},"检查触发信号，满足与逻辑",{"key":24,"text":471,"correct":26},"更换控制模块或检修线路",{"key":69,"text":473,"correct":22},"更换匹配的风机",{"key":72,"text":475,"correct":26},"排除风阀故障",{"id":477,"libraryId":5,"type":80,"typeLabel":81,"stem":478,"options":479,"answer":69,"analysis":27},974791,"下列不属于挡烟垂壁不能自动启动的故障原因是（ ）。",[480,482,484,486],{"key":20,"text":481,"correct":26},"控制模块或线路发生故障",{"key":24,"text":483,"correct":26},"配用探测器发生故障",{"key":69,"text":485,"correct":22},"控制器内电气发生故障",{"key":72,"text":487,"correct":26},"未编写联动公式或联动公式错误",{"id":489,"libraryId":5,"type":80,"typeLabel":81,"stem":490,"options":491,"answer":24,"analysis":27},974792,"检测发现，防烟系统活动挡烟垂壁升降不顺畅、升降不到位，下列属于其故障原因的是（ ）。",[492,493,495,496],{"key":20,"text":481,"correct":26},{"key":24,"text":494,"correct":22},"上、下限位的调试不规范",{"key":69,"text":485,"correct":26},{"key":72,"text":497,"correct":26},"驱动电机发生故障或缺电",{"id":499,"libraryId":5,"type":80,"typeLabel":81,"stem":500,"options":501,"answer":20,"analysis":27},974793,"下列不属于总线控制盘不能远程手动启动风阀（不包括未设电动开启功能的排烟防火阀）故障的原因是（ ）。",[502,504,505,507],{"key":20,"text":503,"correct":22},"消防联动控制为“手动允许”状态",{"key":24,"text":481,"correct":26},{"key":69,"text":506,"correct":26},"总线控制盘键盘板发生故障",{"key":72,"text":508,"correct":26},"风阀发生故障",{"id":510,"libraryId":5,"type":80,"typeLabel":81,"stem":511,"options":512,"answer":24,"analysis":27},974794,"下列不属于传动带跳动或打滑的故障处理方法是（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":26},"调节电动机位置使传动带张紧或松驰",{"key":24,"text":516,"correct":22},"更换轴承",{"key":69,"text":518,"correct":26},"调整带轮位置，使其在同一直线上",{"key":72,"text":520,"correct":26},"更换传动带",{"id":522,"libraryId":5,"type":80,"typeLabel":81,"stem":523,"options":524,"answer":24,"analysis":27},974795,"下列关于风阀启闭状态故障的维修方法不正确的是（ ）。",[525,527,528,530],{"key":20,"text":526,"correct":26},"及时复位风阀",{"key":24,"text":471,"correct":22},{"key":69,"text":529,"correct":26},"更换温感器后正确启闭风阀",{"key":72,"text":531,"correct":26},"检查棘轮、棘齿脱扣原因，发现咬合处磨损严重、弹簧弹力不足等问题的，更换相关零件",{"id":533,"libraryId":5,"type":80,"typeLabel":81,"stem":534,"options":535,"answer":20,"analysis":27},974796,"下列不属于风阀动作后无反馈的故障原因是（ ）。",[536,537,539,541],{"key":20,"text":487,"correct":22},{"key":24,"text":538,"correct":26},"微动开关损坏",{"key":69,"text":540,"correct":26},"信号线路开路或断路",{"key":72,"text":542,"correct":26},"输入模块损坏",{"id":544,"libraryId":5,"type":80,"typeLabel":81,"stem":545,"options":546,"answer":20,"analysis":27},974797,"下列关于挡烟垂壁不能自动启动的故障维修方法不正确的是（ ）。",[547,549,551,552],{"key":20,"text":548,"correct":22},"控制器缺电",{"key":24,"text":550,"correct":26},"更换专用探测器",{"key":69,"text":471,"correct":26},{"key":72,"text":553,"correct":26},"重新编写联动公式",{"id":555,"libraryId":5,"type":60,"typeLabel":61,"stem":556,"options":557,"answer":77,"analysis":27},974798,"下列属于消防电话系统分机不断呼叫电话主机的原因是（ ）。",[558,560,562,564,566],{"key":20,"text":559,"correct":22},"分机与底座意外脱落",{"key":24,"text":561,"correct":22},"分机外挂线路发生故障",{"key":69,"text":563,"correct":26},"分机或插孔自身损坏",{"key":72,"text":565,"correct":26},"电话总线断路",{"key":75,"text":567,"correct":22},"分机或插孔间重码",[569,572,575,578,581,584],{"id":80,"name":570,"category":7,"favorite":571},"领导干部任职前廉政法规知识测试题",92,{"id":573,"name":574,"category":7,"favorite":80},595,"建筑结构与设备",{"id":576,"name":577,"category":7,"favorite":80},715,"招标采购专业知识与法律法规",{"id":579,"name":580,"category":7,"favorite":80},848,"市政方向-通用基础",{"id":582,"name":583,"category":7,"favorite":8},534,"BIM工程师",{"id":585,"name":583,"category":7,"favorite":8},535]