[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-36":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":519},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,36,50,2486,[13,37,53,68,78,84,90,96,102,108,114,120,126,132,138,152,164,176,188,200,212,224,232,242,254,265,277,289,300,312,324,334,348,357,371,382,395,407,421,435,448,459,471,477,483,489,495,501,507,513],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":35,"analysis":36},974699,2,"多选题","下列属于干式报警阀自动滴水阀滴漏不止的原因是（ ）。",[19,23,26,29,32],{"key":20,"text":21,"correct":22},"A","注水阀未关严",true,{"key":24,"text":25,"correct":22},"B","阀瓣密封圈磨损、老化开裂或变形",{"key":27,"text":28,"correct":22},"C","阀座上有异物",{"key":30,"text":31,"correct":22},"D","警铃试验阀关闭不严或损坏",{"key":33,"text":34,"correct":22},"E","阀座的座圈有裂纹以致丧失密封","ABCDE","",{"id":38,"libraryId":5,"type":15,"typeLabel":16,"stem":39,"options":40,"answer":52,"analysis":36},974700,"下列属于消防水泵结合器漏水的原因是（ ）",[41,43,46,48,50],{"key":20,"text":42,"correct":22},"止回阀安装方向错误",{"key":24,"text":44,"correct":45},"止回阀开启度不够",false,{"key":27,"text":47,"correct":22},"止回阀损坏",{"key":30,"text":49,"correct":22},"止回阀被砂石等异物卡住",{"key":33,"text":51,"correct":45},"控制阀损坏","ACD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":36},974701,"下列属于报警管路误报警的原因是（ ）",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"未按照安装图纸安装或未按照调试要求进行调试",{"key":24,"text":60,"correct":22},"报警阀渗漏严重",{"key":27,"text":62,"correct":22},"湿式系统延迟器下部板溢出水孔堵塞",{"key":30,"text":64,"correct":45},"充气管路连接处松动",{"key":33,"text":66,"correct":45},"产品质量问题或安装调试不符合要求","ABC",{"id":69,"libraryId":5,"type":70,"typeLabel":71,"stem":72,"options":73,"answer":75,"analysis":36},974702,3,"判断题","阀瓣组件与阀座之间因变形或污垢、杂物阻挡出现不密封状态会出现报警阀组漏水。",[74,76],{"key":20,"text":75,"correct":22},"正确",{"key":24,"text":77,"correct":45},"错误",{"id":79,"libraryId":5,"type":70,"typeLabel":71,"stem":80,"options":81,"answer":75,"analysis":36},974703,"稳压泵启停压力设定不正确会造成稳压泵启动频繁或不能正常启动。",[82,83],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},{"id":85,"libraryId":5,"type":70,"typeLabel":71,"stem":86,"options":87,"answer":77,"analysis":36},974704,"MlZSTX15-93龙表示Ml型，标准响应、直立安装，公称口径为15mm，公称动作温度为93龙的喷头。",[88,89],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":91,"libraryId":5,"type":70,"typeLabel":71,"stem":92,"options":93,"answer":77,"analysis":36},974705,"红色喷头的公称动作温度为57℃。",[94,95],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":97,"libraryId":5,"type":70,"typeLabel":71,"stem":98,"options":99,"answer":75,"analysis":36},974706,"水箱出水管止回阀装反也会导致消防水池（水箱）无法出水和放空。",[100,101],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},{"id":103,"libraryId":5,"type":70,"typeLabel":71,"stem":104,"options":105,"answer":77,"analysis":36},974707,"止回阀安装方向错误会导致消防水泵结合器过水能力不足。",[106,107],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":109,"libraryId":5,"type":70,"typeLabel":71,"stem":110,"options":111,"answer":75,"analysis":36},974708,"注水阀未关严也会导致干式报警阀自动滴水阀滴漏不止。",[112,113],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},{"id":115,"libraryId":5,"type":70,"typeLabel":71,"stem":116,"options":117,"answer":77,"analysis":36},974709,"干式报警阀误动作一般是阀瓣密封处渗漏严重，失去底水后漏气，系统测气压下降发生误动作。",[118,119],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":121,"libraryId":5,"type":70,"typeLabel":71,"stem":122,"options":123,"answer":77,"analysis":36},974710,"底水加注过高或过低都会导致干式报警阀误动作、迟动作或不动作。",[124,125],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":127,"libraryId":5,"type":70,"typeLabel":71,"stem":128,"options":129,"answer":77,"analysis":36},974711,"报警阀气室相关管路处有渗漏点，可用清水检查报警阀与相关管路连接处、管路阀门处有无气体渗漏，检查管路控制阀的启闭状态，连接不严密的按维修程序重新安装，阀门损坏的进行更换，阀门关闭不严密的关闭到位。",[130,131],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":133,"libraryId":5,"type":70,"typeLabel":71,"stem":134,"options":135,"answer":75,"analysis":36},974712,"消防泵组电气控制柜处于“手动”状态，消防控制室远程不能启停消防水泵",[136,137],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},{"id":139,"libraryId":5,"type":140,"typeLabel":141,"stem":142,"options":143,"answer":30,"analysis":36},974713,1,"单选题","下列不属于湿式报警阀开启后报警管路不排水的原因是（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":45},"报警管路控制阀被关闭",{"key":24,"text":147,"correct":45},"限流装置过滤网堵塞",{"key":27,"text":149,"correct":45},"阀座环形槽和小孔堵塞",{"key":30,"text":151,"correct":22},"湿式报警阀损坏",{"id":153,"libraryId":5,"type":140,"typeLabel":141,"stem":154,"options":155,"answer":27,"analysis":36},974714,"下列不属于造成喷头有漏水、腐蚀、表面涂覆、玻璃球中有色液体变色或液体减少等现象原因的是（ ）。",[156,158,160,162],{"key":20,"text":157,"correct":45},"施工质量",{"key":24,"text":159,"correct":45},"自然老化",{"key":27,"text":161,"correct":22},"专用线路断路",{"key":30,"text":163,"correct":45},"长期带压环境",{"id":165,"libraryId":5,"type":140,"typeLabel":141,"stem":166,"options":167,"answer":20,"analysis":36},974715,"下列不属于湿式报警阀阀前压力表显示正常，但阀后压力表显示无压力或水压不足维修解决方法的是（ ）",[168,170,172,174],{"key":20,"text":169,"correct":22},"排查并打开被误关的阀门",{"key":24,"text":171,"correct":45},"对进水管路进行冲洗、维修",{"key":27,"text":173,"correct":45},"更换压力表",{"key":30,"text":175,"correct":45},"对湿式报警阀和补偿管路进行维修",{"id":177,"libraryId":5,"type":140,"typeLabel":141,"stem":178,"options":179,"answer":24,"analysis":36},974716,"下列不属于干式报警阀迟动作或不动作的原因是（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":45},"底水加注过高",{"key":24,"text":183,"correct":22},"未定期检查和加注底水",{"key":27,"text":185,"correct":45},"水源侧压力不足",{"key":30,"text":187,"correct":45},"系统管网容积较大，未设加速器或加速器损坏",{"id":189,"libraryId":5,"type":140,"typeLabel":141,"stem":190,"options":191,"answer":27,"analysis":36},974717,"下列不属于湿式报警阀组漏水原因的是（ ）。",[192,194,196,198],{"key":20,"text":193,"correct":45},"排水阀门未完全关闭",{"key":24,"text":195,"correct":45},"阀瓣密封垫老化或损坏",{"key":27,"text":197,"correct":22},"压力表损坏",{"key":30,"text":199,"correct":45},"报警管路警铃试验阀处渗漏",{"id":201,"libraryId":5,"type":140,"typeLabel":141,"stem":202,"options":203,"answer":27,"analysis":36},974718,"下列不属于末端试水装置测试时，水流指示器不动作维修方法的是（ ）。",[204,206,208,210],{"key":20,"text":205,"correct":45},"消除水流指示器管腔内的异物",{"key":24,"text":207,"correct":45},"将调整螺母与触头调试到位",{"key":27,"text":209,"correct":22},"排查系统侧管网渗漏点并进行维修",{"key":30,"text":211,"correct":45},"维修和更换复位弹簧",{"id":213,"libraryId":5,"type":140,"typeLabel":141,"stem":214,"options":215,"answer":27,"analysis":36},974719,"下列属于喷头有漏水、腐蚀、表面涂覆、玻璃球中有色液体变色或液体减少等现象的维修方法是（ ）。",[216,218,220,222],{"key":20,"text":217,"correct":45},"对线路进行检查维修",{"key":24,"text":219,"correct":45},"对多线控制盘进行检查维修",{"key":27,"text":221,"correct":22},"使用专用扳手更换喷头",{"key":30,"text":223,"correct":45},"检查并接实脱落线路",{"id":225,"libraryId":5,"type":140,"typeLabel":141,"stem":226,"options":227,"answer":20,"analysis":36},974720,"下列不属于干式报警阀自动滴水阀滴漏不止不的原因是（ ）。",[228,229,230,231],{"key":20,"text":145,"correct":22},{"key":24,"text":25,"correct":45},{"key":27,"text":28,"correct":45},{"key":30,"text":31,"correct":45},{"id":233,"libraryId":5,"type":140,"typeLabel":141,"stem":234,"options":235,"answer":30,"analysis":36},974721,"下列不属于干式系统空压机启动频繁的原因是（ ）。",[236,238,239,241],{"key":20,"text":237,"correct":45},"干式系统空压机启停压力设定不正确",{"key":24,"text":64,"correct":45},{"key":27,"text":240,"correct":45},"报警阀气室相关管路处有渗漏点",{"key":30,"text":185,"correct":22},{"id":243,"libraryId":5,"type":140,"typeLabel":141,"stem":244,"options":245,"answer":30,"analysis":36},974722,"下列不属于消防水池（水箱）漏水原因的是（ ）。",[246,248,250,252],{"key":20,"text":247,"correct":45},"排污管（放空管）、出水管管路渗漏",{"key":24,"text":249,"correct":45},"排污管（放空管）上控制阀未关闭",{"key":27,"text":251,"correct":45},"消防水池水箱（腐蚀）或锈蚀",{"key":30,"text":253,"correct":22},"消防水泵控制阀未完全关闭",{"id":255,"libraryId":5,"type":140,"typeLabel":141,"stem":256,"options":257,"answer":20,"analysis":36},974723,"下列不属于系统测试时，消防水泵不能自动启动的维修方法是（ ）。",[258,259,261,263],{"key":20,"text":223,"correct":22},{"key":24,"text":260,"correct":45},"将消防泵组电气控制柜控制模式设定为“自动”状态",{"key":27,"text":262,"correct":45},"对控制回路和电气部件进行检修",{"key":30,"text":264,"correct":45},"将消防总线联动控制设置成“自动”状态，核定问题模块，并予以更换",{"id":266,"libraryId":5,"type":140,"typeLabel":141,"stem":267,"options":268,"answer":30,"analysis":36},974724,"下列不属于稳压泵不能正常启动的原因是（ ）",[269,271,273,275],{"key":20,"text":270,"correct":45},"稳压泵启泵压力设定不正确",{"key":24,"text":272,"correct":45},"稳压泵启停的压力信号开关控制不能正常工作",{"key":27,"text":274,"correct":45},"消防联动控制设备中的控制模块损坏",{"key":30,"text":276,"correct":22},"稳压泵损坏",{"id":278,"libraryId":5,"type":140,"typeLabel":141,"stem":279,"options":280,"answer":30,"analysis":36},974725,"下列不属于稳压泵不能正常启动的维修方法是（ ）",[281,283,285,287],{"key":20,"text":282,"correct":45},"根据设计值重新设定稳压泵启泵压力",{"key":24,"text":284,"correct":45},"检测和调整压力信号开关控制，使正常启闭，不能修复的予以更换",{"key":27,"text":286,"correct":45},"逐一检查控制模块，采用其他方式启动稳压泵，核定问题模块，予以修复或更换",{"key":30,"text":288,"correct":22},"将控制模式设定为手动状态",{"id":290,"libraryId":5,"type":140,"typeLabel":141,"stem":291,"options":292,"answer":24,"analysis":36},974726,"下列不属于干式报警阀误动作原因的是（ ）。",[293,295,296,298],{"key":20,"text":294,"correct":45},"阀瓣密封处渗漏严重",{"key":24,"text":181,"correct":22},{"key":27,"text":297,"correct":45},"供气装置发生故障",{"key":30,"text":299,"correct":45},"系统侧管网发生不正常漏气",{"id":301,"libraryId":5,"type":140,"typeLabel":141,"stem":302,"options":303,"answer":20,"analysis":36},974727,"下列不属于系统测试时，消防水泵不能自动启动的原因是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":22},"电路接线脱落",{"key":24,"text":307,"correct":45},"消防泵组电气控制柜的控制模式未设定在“自动”状态",{"key":27,"text":309,"correct":45},"控制回路、电气部件发生故障",{"key":30,"text":311,"correct":45},"消防总线联动控制未设定在“自动”状态或输出模块损坏",{"id":313,"libraryId":5,"type":140,"typeLabel":141,"stem":314,"options":315,"answer":30,"analysis":36},974728,"下列不属于稳压泵漏水维修方法的是（ ）。",[316,318,320,322],{"key":20,"text":317,"correct":45},"更换密封圈",{"key":24,"text":319,"correct":45},"检查管道接口渗漏点，管道接口锈蚀、磨损严重的，更换管道接口相关部件",{"key":27,"text":321,"correct":45},"维修或更换控制阀",{"key":30,"text":323,"correct":22},"关闭泄水阀门",{"id":325,"libraryId":5,"type":140,"typeLabel":141,"stem":326,"options":327,"answer":24,"analysis":36},974729,"下列不能解决气压罐内供水量不足的是（ ）。",[328,329,330,332],{"key":20,"text":323,"correct":45},{"key":24,"text":321,"correct":22},{"key":27,"text":331,"correct":45},"根据气压罐设计值，检查并标定有效容积、水位及工作压力",{"key":30,"text":333,"correct":45},"检查气压罐管路系统",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":347,"analysis":36},974730,"下列属于干式系统空压机启动频繁的故障维修方法的是（ ）。",[338,340,342,344,345],{"key":20,"text":339,"correct":22},"按设计要求重新调整干式系统空压机启停压力",{"key":24,"text":341,"correct":22},"检查并紧固充气管路各连接处",{"key":27,"text":343,"correct":22},"排查报警阀气室相关管路处渗漏点并进行维修",{"key":30,"text":209,"correct":22},{"key":33,"text":346,"correct":45},"水源侧压力不足，导致干式报警阀迟开","ABCD",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":347,"analysis":36},974731,"下列属于干式报警阀误动作的可能原因是（ ）。 A.阀瓣密封处渗漏严重 B.未定期检查和加注底水 C.供气装置发生故障 D.系统侧管网发生不正常漏气",[352,353,354,355,356],{"key":20,"text":20,"correct":22},{"key":24,"text":24,"correct":22},{"key":27,"text":27,"correct":22},{"key":30,"text":30,"correct":22},{"key":33,"text":33,"correct":45},{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":347,"analysis":36},974732,"下列关于干式报警阀误动作的故障维修方法正确的是（ ）。",[361,363,365,367,369],{"key":20,"text":362,"correct":22},"检查阀瓣密封处渗漏原因，及时清理异物，维修或更换损坏件",{"key":24,"text":364,"correct":22},"定期检查和加注底水",{"key":27,"text":366,"correct":22},"排查供气装置故障原因并进行维修处理",{"key":30,"text":368,"correct":22},"排查系统侧管网漏气点并进行维修",{"key":33,"text":370,"correct":45},"安装或更换加速器并进行调试",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":347,"analysis":36},974733,"下列属于消防控制室远程不能启停消防水泵的维修方法有（ ）。",[375,376,377,379,381],{"key":20,"text":217,"correct":22},{"key":24,"text":219,"correct":22},{"key":27,"text":378,"correct":22},"对损坏模块进行更换",{"key":30,"text":380,"correct":22},"将多线控制盘解锁为“手动允许”",{"key":33,"text":264,"correct":45},{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":347,"analysis":36},974734,"关闭末端试水装置后，水流指示器反馈信号仍然显示为动作信号，下列属于其故障的原因的是（ ）。",[386,388,390,391,393],{"key":20,"text":387,"correct":22},"浆片被管腔内杂物卡阻",{"key":24,"text":389,"correct":22},"调整螺母与触头未调试到位",{"key":27,"text":305,"correct":22},{"key":30,"text":392,"correct":22},"复位弹簧损坏",{"key":33,"text":394,"correct":45},"管路控制阀未关闭",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":347,"analysis":36},974735,"下列无法通过消防水泵接合器向室内管网供水的原因是（ ）。",[399,400,402,404,406],{"key":20,"text":42,"correct":22},{"key":24,"text":401,"correct":22},"控制阀被误关闭",{"key":27,"text":403,"correct":22},"阀门或管内水冻结",{"key":30,"text":405,"correct":22},"消防水泵结合器选择错误",{"key":33,"text":49,"correct":45},{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":35,"analysis":36},974736,"下列属于消防水池（水箱）无法出水和放空的维修方法是（ ）。",[411,413,415,417,419],{"key":20,"text":412,"correct":22},"增补防冻措施，消除冰封",{"key":24,"text":414,"correct":22},"进行清洗、清理和疏通作业",{"key":27,"text":416,"correct":22},"维修或加设防护网",{"key":30,"text":418,"correct":22},"维修或更换损坏的阀门",{"key":33,"text":420,"correct":22},"正确安装止回阀或进行维修更换",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":347,"analysis":36},974737,"下列属于消防水池（水箱）液位报警的维修方法的是（ ）",[425,427,429,431,433],{"key":20,"text":426,"correct":22},"维修和更换浮球阀、液位控制阀",{"key":24,"text":428,"correct":22},"排查液位过低原因并进行维修",{"key":27,"text":430,"correct":22},"维修或更换液位报警装置",{"key":30,"text":432,"correct":22},"重新设定报警液位",{"key":33,"text":434,"correct":45},"按要求安装就地液位显示装置",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":447,"analysis":36},974738,"下列属于气压罐内供水量不足的解决办法是（ ）。",[439,441,442,443,445],{"key":20,"text":440,"correct":45},"更换管道接口相关部件",{"key":24,"text":321,"correct":45},{"key":27,"text":331,"correct":22},{"key":30,"text":444,"correct":22},"检查气压罐管路系统，关闭泄水阀门",{"key":33,"text":446,"correct":45},"维修或更换气压罐","CD",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":35,"analysis":36},974739,"下列属于稳压泵不能正常启动的原因是（ ）。",[452,453,454,455,457],{"key":20,"text":270,"correct":22},{"key":24,"text":272,"correct":22},{"key":27,"text":274,"correct":22},{"key":30,"text":456,"correct":22},"消防泵组电气控制柜、联动控制设备的控制模式未设定在“自动”状态",{"key":33,"text":458,"correct":22},"灭火后稳压泵处于停止状态",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":67,"analysis":36},974740,"下列属于干式报警阀迟动作或不动作的原因是（ ）",[463,465,467,468,470],{"key":20,"text":464,"correct":22},"保持底水在正常水位",{"key":24,"text":466,"correct":22},"进一步排查水源侧压力不足原因并进行维修",{"key":27,"text":370,"correct":22},{"key":30,"text":469,"correct":45},"检查阀瓣密封处渗漏原因",{"key":33,"text":297,"correct":45},{"id":472,"libraryId":5,"type":70,"typeLabel":71,"stem":473,"options":474,"answer":77,"analysis":36},974741,"报警管路控制阀应保持常闭，否则易造成水力警铃工作不正常。",[475,476],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":478,"libraryId":5,"type":70,"typeLabel":71,"stem":479,"options":480,"answer":77,"analysis":36},974742,"电路接线脱落、复位弹簧损坏是末端试水装置测试时，水流指示器不动作，或关闭末端试水装置后，水流指示器反馈信号仍然显示为动作信号的原因。",[481,482],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":484,"libraryId":5,"type":70,"typeLabel":71,"stem":485,"options":486,"answer":75,"analysis":36},974743,"若消防泵组电气控制柜的控制模式未设定在“自动”状态，系统测试时，消防水泵不能自动启动。",[487,488],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},{"id":490,"libraryId":5,"type":70,"typeLabel":71,"stem":491,"options":492,"answer":75,"analysis":36},974744,"若消防总线联动控制未设定在“自动”状态或输出模块损坏，系统测试时，消防水泵不能自动启动。",[493,494],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},{"id":496,"libraryId":5,"type":70,"typeLabel":71,"stem":497,"options":498,"answer":77,"analysis":36},974745,"气压罐内供水量不足，原因可能是稳压泵进出水管道接口渗漏。",[499,500],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":502,"libraryId":5,"type":70,"typeLabel":71,"stem":503,"options":504,"answer":77,"analysis":36},974746,"消防泵组电气控制柜、联动控制设备的控制模式设定在“自动”状态会导致稳压泵不能正常启动",[505,506],{"key":20,"text":75,"correct":45},{"key":24,"text":77,"correct":22},{"id":508,"libraryId":5,"type":70,"typeLabel":71,"stem":509,"options":510,"answer":75,"analysis":36},974747,"湿式报警阀漏水也会引起报警管路误报警。",[511,512],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},{"id":514,"libraryId":5,"type":70,"typeLabel":71,"stem":515,"options":516,"answer":75,"analysis":36},974748,"稳压泵在规定时间内不能恢复压力，可能是管道内残存空气，可打开就近的泄水通道，完全排出管道空气。",[517,518],{"key":20,"text":75,"correct":22},{"key":24,"text":77,"correct":45},[520,523,526,529,532,535],{"id":140,"name":521,"category":7,"favorite":522},"领导干部任职前廉政法规知识测试题",92,{"id":524,"name":525,"category":7,"favorite":140},595,"建筑结构与设备",{"id":527,"name":528,"category":7,"favorite":140},715,"招标采购专业知识与法律法规",{"id":530,"name":531,"category":7,"favorite":140},848,"市政方向-通用基础",{"id":533,"name":534,"category":7,"favorite":8},534,"BIM工程师",{"id":536,"name":534,"category":7,"favorite":8},535]