[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":479},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,32,50,2486,[13,34,46,56,62,68,74,92,107,117,129,143,149,161,171,177,189,195,201,210,222,228,243,249,255,261,267,273,279,285,291,297,303,309,321,333,345,359,365,371,377,389,401,410,422,431,443,455,467,473],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},974499,1,"单选题","防排烟联动控制中，当防火分区内火灾确认后，应能在（ ）s内联动开启常闭加压送风口和加压送风机",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","10",false,{"key":24,"text":25,"correct":26},"B","15",true,{"key":28,"text":29,"correct":22},"C","30",{"key":31,"text":32,"correct":22},"D","60","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},974500,"火灾显示盘工作状态指示灯，故障状态以（ ）色指示",[38,40,42,44],{"key":20,"text":39,"correct":22},"红",{"key":24,"text":41,"correct":22},"绿",{"key":28,"text":43,"correct":26},"黄",{"key":31,"text":45,"correct":22},"蓝",{"id":47,"libraryId":5,"type":48,"typeLabel":49,"stem":50,"options":51,"answer":53,"analysis":33},974501,3,"判断题","回路配接设备在列表显示方式下，第三列为设备类型以及对应的盘号键值。",[52,54],{"key":20,"text":53,"correct":26},"正确",{"key":24,"text":55,"correct":22},"错误",{"id":57,"libraryId":5,"type":48,"typeLabel":49,"stem":58,"options":59,"answer":53,"analysis":33},974502,"由于振动等原因会产生较大位移的场所，不宜选择线型光束感烟火灾探测器",[60,61],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":63,"libraryId":5,"type":48,"typeLabel":49,"stem":64,"options":65,"answer":55,"analysis":33},974503,"当火灾发生时，随着灭火设备开启用水，由于稳压泵流量较小，气压罐内的水量持续减少，罐内压力不断下降，当压力持续10S低于设定的消防泵组启动压力p1时，消防泵组自动启动向消防给水管网供水。",[66,67],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":69,"libraryId":5,"type":48,"typeLabel":49,"stem":70,"options":71,"answer":53,"analysis":33},974504,"当集中火灾报警控制器、消防联动控制器处于手动状态时，收到火灾报警信息时，会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，但不会联动启动声光报警、消防广播及所控制的现场消防设备。",[72,73],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":75,"libraryId":5,"type":76,"typeLabel":77,"stem":78,"options":79,"answer":91,"analysis":33},974505,2,"多选题","下列消防水泵启动方式中，属于手动启动控制方式的是（ ）",[80,82,84,86,88],{"key":20,"text":81,"correct":22},"消防控制室总线联动启动",{"key":24,"text":83,"correct":22},"高位消防水箱出水管流量开关启动",{"key":28,"text":85,"correct":22},"消防水泵出水干管压力开关启动",{"key":31,"text":87,"correct":26},"消防控制室多线控制盘操作按钮启动",{"key":89,"text":90,"correct":26},"E","控制柜面板启\u002F停按钮控制水泵启停","DE",{"id":93,"libraryId":5,"type":76,"typeLabel":77,"stem":94,"options":95,"answer":106,"analysis":33},974506,"消防电话系统的形式有（ ）",[96,98,100,102,104],{"key":20,"text":97,"correct":26},"总线制",{"key":24,"text":99,"correct":26},"多线制",{"key":28,"text":101,"correct":22},"固定式",{"key":31,"text":103,"correct":22},"移动便携式",{"key":89,"text":105,"correct":22},"半移动式","AB",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":28,"analysis":33},974507,"测试线型感温火灾探测器火灾报警、故障报警功能，应使用温度不低于（ ）°C的热水持续对线型缆式感温火灾探测器的感温电缆进行加热。",[111,112,114,116],{"key":20,"text":29,"correct":22},{"key":24,"text":113,"correct":22},"50",{"key":28,"text":115,"correct":26},"54",{"key":31,"text":32,"correct":22},{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":28,"analysis":33},974508,"关于机械加压送风系统的控制，下列说法错误的是（ ）",[121,123,125,127],{"key":20,"text":122,"correct":22},"系统中任一常闭加压送风口开启时，加压风机应能自动启动。",{"key":24,"text":124,"correct":22},"加压送风机应能现场手动启动、通过火灾自动报警系统自动启动、消防控制室手动启动",{"key":28,"text":126,"correct":26},"当防火分区内火灾确认后，应开启该防火分区楼梯间的全部加压送风机和前室的常闭送风口。",{"key":31,"text":128,"correct":22},"当防火分区内火灾确认后，应能在15s内联动开启常闭加压送风口和加压送风机",{"id":130,"libraryId":5,"type":76,"typeLabel":77,"stem":131,"options":132,"answer":142,"analysis":33},974509,"判别现场消防设备工作状态时，设备信息查看的方式包括（ ）。",[133,135,137,139,140],{"key":20,"text":134,"correct":26},"设备查看",{"key":24,"text":136,"correct":26},"分类查看",{"key":28,"text":138,"correct":26},"分区查看",{"key":31,"text":136,"correct":22},{"key":89,"text":141,"correct":22},"分组查看","ABC",{"id":144,"libraryId":5,"type":48,"typeLabel":49,"stem":145,"options":146,"answer":53,"analysis":33},974510,"风机电气控制柜面板电源指示灯，控制柜通电时点亮；运行指示灯，风机运转时点亮。",[147,148],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":28,"analysis":33},974511,"消防应急广播系统消音指示灯平时媳灭，有故障时按下消音键常亮为（ ）色。",[153,155,157,159],{"key":20,"text":154,"correct":22},"红色",{"key":24,"text":156,"correct":22},"绿色",{"key":28,"text":158,"correct":26},"黄色",{"key":31,"text":160,"correct":22},"蓝色",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":20,"analysis":33},974512,"应急照明控制器接收到火灾报警控制器的火警信号后，应在（ ）s内发出系统自动应急启动信号",[165,167,169,170],{"key":20,"text":166,"correct":26},"3",{"key":24,"text":168,"correct":22},"5",{"key":28,"text":21,"correct":22},{"key":31,"text":29,"correct":22},{"id":172,"libraryId":5,"type":48,"typeLabel":49,"stem":173,"options":174,"answer":55,"analysis":33},974513,"防火门监控器上接防火门监控模块和电动闭门器、电磁释放器、门磁开关等现场执行部件，下接火灾报警控制器",[175,176],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":28,"analysis":33},974514,"消防电话手柄拨打消防电话总机的方法，下列说法错误的是（ ）",[181,183,185,187],{"key":20,"text":182,"correct":22},"将消防电话手柄连接线端部插头插入任意一个消防电话插孔，可自动呼叫消防电话总机",{"key":24,"text":184,"correct":22},"消防电话总机发出声、光报警，呼叫灯点亮，呼叫时间被记录保存",{"key":28,"text":186,"correct":26},"取下消防电话总机听筒，即可与消防电话分机通话，此时通话灯和呼叫灯常亮，消防电话总机对通话自动录音",{"key":31,"text":188,"correct":22},"将消防电话手柄连接线端部插头拔出电话插孔，挂断通话，消防电话系统恢复正常工作状态",{"id":190,"libraryId":5,"type":48,"typeLabel":49,"stem":191,"options":192,"answer":53,"analysis":33},974515,"消防应急灯具按应急控制方式分为集中控制型消防应急灯具、非集中控制型消防应急灯具。",[193,194],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":196,"libraryId":5,"type":48,"typeLabel":49,"stem":197,"options":198,"answer":55,"analysis":33},974516,"液化石油气储罐宜选择线型光纤感温火灾探测器",[199,200],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":33},974517,"火灾报警控制器发出故障信号后，火灾显示盘应（ ）s内发出故障声、光信号，并指示故障发生部位",[205,207,208,209],{"key":20,"text":206,"correct":22},"1",{"key":24,"text":166,"correct":26},{"key":28,"text":21,"correct":22},{"key":31,"text":29,"correct":22},{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":20,"analysis":33},974518,"消防泵组电气控制柜转换开关处于下图位置，表示（ ）。",[214,216,218,220],{"key":20,"text":215,"correct":26},"1#泵为主泵、2#泵为备用泵",{"key":24,"text":217,"correct":22},"1个主泵，2个备用泵",{"key":28,"text":219,"correct":22},"2#泵为主泵、1#泵为备用泵",{"key":31,"text":221,"correct":22},"2个主泵，1个备用泵",{"id":223,"libraryId":5,"type":48,"typeLabel":49,"stem":224,"options":225,"answer":53,"analysis":33},974519,"防火卷帘具有现场手动电控、自动控制、消防控制室远程手动控制、温控释放控制、速放控制、现场机械控制和限位控制主要控制方式",[226,227],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":229,"libraryId":5,"type":76,"typeLabel":77,"stem":230,"options":231,"answer":242,"analysis":33},974520,"关于加压送风机的控制，下列说法正确的是（ ）",[232,234,236,238,240],{"key":20,"text":233,"correct":26},"现场手动启动",{"key":24,"text":235,"correct":26},"通过火灾自动报警系统自动启动",{"key":28,"text":237,"correct":26},"消防控制室手动启动",{"key":31,"text":239,"correct":26},"系统中任一常闭加压送风口开启时，加压风机自动启动",{"key":89,"text":241,"correct":22},"机械应急启动","ABCD",{"id":244,"libraryId":5,"type":48,"typeLabel":49,"stem":245,"options":246,"answer":55,"analysis":33},974521,"风机电气控制柜内设有双电源转换开关，当控制按钮处于“自动”位时，主电源发生故障，备用电源能自动投入使用，主电源恢复后，通过人工切回主电源供电。",[247,248],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":250,"libraryId":5,"type":48,"typeLabel":49,"stem":251,"options":252,"answer":53,"analysis":33},974522,"现场机械控制防火卷帘，指的是防火卷帘卷门机上设有手动拉链，可通过人工拉动拉链控制卷帘升降",[253,254],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":256,"libraryId":5,"type":48,"typeLabel":49,"stem":257,"options":258,"answer":53,"analysis":33},974523,"利用消防控制室图形显示装置查询报警历史信息时，可查询火警、监管、反馈及是否消除、启动及是否停止、故障及是否恢复、屏蔽及是否解除、其他事件。",[259,260],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":262,"libraryId":5,"type":48,"typeLabel":49,"stem":263,"options":264,"answer":53,"analysis":33},974524,"消防电话系统由消防电话总机、消防电话分机、消防电话插孔、消防电话手柄和专用消防电话线路组成，分为总线制和多线制两种形式",[265,266],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":268,"libraryId":5,"type":48,"typeLabel":49,"stem":269,"options":270,"answer":55,"analysis":33},974525,"火灾显示盘应能接收与其连接的火灾报警控制器发出的火灾报警信号，并在火灾报警控制器发出火灾报警信号后30s内发出火灾报警声、光信号，显示火灾发生部位",[271,272],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":274,"libraryId":5,"type":48,"typeLabel":49,"stem":275,"options":276,"answer":53,"analysis":33},974526,"干式自动喷水灭火系统适用环境温度低于4℃或高于70℃的场所",[277,278],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":280,"libraryId":5,"type":48,"typeLabel":49,"stem":281,"options":282,"answer":55,"analysis":33},974527,"固定式消防电话分机具有被叫振铃和拨号通话功能，主要用于跟消防控制室电话总机进行通话使用",[283,284],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":286,"libraryId":5,"type":48,"typeLabel":49,"stem":287,"options":288,"answer":53,"analysis":33},974528,"消防联动控制器对消防设备的直线控制，指的是采用独立的手动控制单元，每个控制单元通过直接连接的导线和控制模块对应控制一个受控消防设备，属于点对点控制方式。",[289,290],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":292,"libraryId":5,"type":48,"typeLabel":49,"stem":293,"options":294,"answer":55,"analysis":33},974529,"消防联动控制器在自动控制状态下，不可以插人手动操作，控制受控消防设备的启动或停止",[295,296],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":298,"libraryId":5,"type":48,"typeLabel":49,"stem":299,"options":300,"answer":53,"analysis":33},974530,"多线控制盘的手动锁在“禁止”状态下，工作指示灯处于红灯运行状态，不能通过多线控制盘手动直接启动消防泵组、防烟和排烟风机等设备",[301,302],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":304,"libraryId":5,"type":48,"typeLabel":49,"stem":305,"options":306,"answer":55,"analysis":33},974531,"发生火灾时，加压送风应做到：防烟楼梯间压力>走道压力>前室压力>房间压力",[307,308],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":20,"analysis":33},974532,"根据规范要求，距扬声器正前方3m处应急广播的播放声压级不应小于（ ）d B，且不大于（ ）dB。",[313,315,317,319],{"key":20,"text":314,"correct":26},"65；115",{"key":24,"text":316,"correct":22},"70；115",{"key":28,"text":318,"correct":22},"70；150",{"key":31,"text":320,"correct":22},"65；120",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":24,"analysis":33},974533,"应急照明控制器在消防控制室墙面上设置时，设备主显示屏高度宜为（ ）m",[325,327,329,331],{"key":20,"text":326,"correct":22},"1.3-1.5",{"key":24,"text":328,"correct":26},"1.5-1.8",{"key":28,"text":330,"correct":22},"1.8-2",{"key":31,"text":332,"correct":22},"2",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":24,"analysis":33},974534,"如现场设备启动信息没有反馈回来，“反馈”指示灯应处于（ ）",[337,339,341,343],{"key":20,"text":338,"correct":22},"常亮状态",{"key":24,"text":340,"correct":26},"熄灭状态",{"key":28,"text":342,"correct":22},"闪烁状态",{"key":31,"text":344,"correct":22},"昏暗状态",{"id":346,"libraryId":5,"type":76,"typeLabel":77,"stem":347,"options":348,"answer":91,"analysis":33},974535,"下列哪些设备，可不采用多线控制盘控制（ ）",[349,351,353,355,357],{"key":20,"text":350,"correct":22},"消火栓泵组",{"key":24,"text":352,"correct":22},"喷淋泵组",{"key":28,"text":354,"correct":22},"加压送风机",{"key":31,"text":356,"correct":26},"防火门",{"key":89,"text":358,"correct":26},"防火卷帘",{"id":360,"libraryId":5,"type":48,"typeLabel":49,"stem":361,"options":362,"answer":53,"analysis":33},974536,"防火门处于故障状态时，防火门监控器应能发出声光报警信号。声信号的声压级（正前方1m处）应为65~85dB。",[363,364],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":366,"libraryId":5,"type":48,"typeLabel":49,"stem":367,"options":368,"answer":55,"analysis":33},974537,"火灾显示盘，又称区域显示器、楼层显示器，是火灾自动报警系统中报警信息的现场分显设备，用来指示所辖区域内现场报警触发设备\u002F模块的报警信息",[369,370],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":372,"libraryId":5,"type":48,"typeLabel":49,"stem":373,"options":374,"answer":53,"analysis":33},974538,"消防水泵不设自动停泵的控制功能，其停止应由具有管理权限的工作人员根据火灾扑救情况确定",[375,376],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":31,"analysis":33},974539,"对于疏散通道上设置的防火卷帘，其自动控制方式的设置，正确的是（ ）",[381,383,385,387],{"key":20,"text":382,"correct":22},"由防火分区内任两只独立的感烟火灾探测器或任一只专门用于联动防火卷帘的感烟火灾探测器的报警信号联动控制防火卷帘下降至楼板",{"key":24,"text":384,"correct":22},"由任一只专门用于联动防火卷帘的感烟火灾探测器的报警信号联动控制防火卷帘下降到楼板面",{"key":28,"text":386,"correct":22},"由防火分区内任两只独立的感温火灾探测器或任一只专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降至距楼板面1.8m处",{"key":31,"text":388,"correct":26},"由任一只专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降到楼板面",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":31,"analysis":33},974540,"关于风机电气控制柜的主要功能，说法错误的是（ ）",[393,395,397,399],{"key":20,"text":394,"correct":22},"当手\u002F自动转换开关处于“手动”位时，风机只能通过控制柜启\u002F停按钮现场控制",{"key":24,"text":396,"correct":22},"当手\u002F自动转换开关处于“自动”位时，能够通过消防控制室远程手动和自动联动控制",{"key":28,"text":398,"correct":22},"双电源转换开关，处于“自动”位时，主电源发生故障，备用电源能自动投入使用，主电源恢复后自动切回主电源供电",{"key":31,"text":400,"correct":26},"双电源转换开关，处于“手动”位时，主电源发生故障，人工切换备用电源投入使用，主电源恢复后自动切回主电源供电",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":31,"analysis":33},974541,"应急照明控制器在消防控制室地面上设置时，在值班人员经常工作的一面，设备面板至墙的距离不应小于（ ）m",[405,406,408,409],{"key":20,"text":206,"correct":22},{"key":24,"text":407,"correct":22},"1.5",{"key":28,"text":332,"correct":22},{"key":31,"text":166,"correct":26},{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":31,"analysis":33},974542,"消防联动控制器采用独立的手动控制单元，每个控制单元通过直接连接的导线和控制模块对应控制一个受控消防设备，属于（ ）方式。",[414,416,418,420],{"key":20,"text":415,"correct":22},"自动控制",{"key":24,"text":417,"correct":22},"直接控制",{"key":28,"text":419,"correct":22},"总线控制",{"key":31,"text":421,"correct":26},"直线控制",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":24,"analysis":33},974543,"某办公楼，共15层，每层划分为一个防火分区，共划分为5个报警区域，根据相关规定，该办公楼至少安装（ ）个火灾显示盘",[426,427,428,430],{"key":20,"text":168,"correct":22},{"key":24,"text":25,"correct":26},{"key":28,"text":429,"correct":22},"20",{"key":31,"text":29,"correct":22},{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":31,"analysis":33},974544,"下列关于多线控制盘的工作原理，说法错误的是（ ）",[435,437,439,441],{"key":20,"text":436,"correct":22},"多线制控制盘也称作多线制手动控制盘或直接手动控制盘",{"key":24,"text":438,"correct":22},"消防泵组除采用联动控制方式外，还应采用多线控制盘控制方式，实现直接手动控制",{"key":28,"text":440,"correct":22},"防烟和排烟风机除采用联动控制方式外，还应采用多线控制盘控制方式，实现直接手动控制",{"key":31,"text":442,"correct":26},"多线控制盘与火灾报警控制器连接，一台火灾报警控制器（联动型）只能设置1个多线控制盘",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":31,"analysis":33},974545,"下列哪种防火卷帘可以应用于防火分隔部位，局部代替防火墙或防火隔墙（ ）",[447,449,451,453],{"key":20,"text":448,"correct":22},"普通钢制防火卷帘",{"key":24,"text":450,"correct":22},"无机纤维复合防火卷帘",{"key":28,"text":452,"correct":22},"有机特级防火卷帘",{"key":31,"text":454,"correct":26},"水雾式（汽雾式）钢质特级防火卷帘",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":24,"analysis":33},974546,"线型光束感烟火灾探测器的光束轴线至顶棚的垂直距离宜为（ ）",[459,461,463,465],{"key":20,"text":460,"correct":22},"0.3m～0.5m",{"key":24,"text":462,"correct":26},"0.3m～1.0m",{"key":28,"text":464,"correct":22},"0.5m～1.0m",{"key":31,"text":466,"correct":22},"0.5m～1.5m",{"id":468,"libraryId":5,"type":48,"typeLabel":49,"stem":469,"options":470,"answer":55,"analysis":33},974547,"具有报脏功能的探测器在报脏时应该及时清洁保养。没有报脏功能的探测器，应按产品说明书的要求进行清洁保养；产品说明书没有明确要求的，应每5年清洁或标定一次。",[471,472],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},{"id":474,"libraryId":5,"type":48,"typeLabel":49,"stem":475,"options":476,"answer":55,"analysis":33},974548,"线型光束感烟火灾探测器每年进行一次报警功能测试。",[477,478],{"key":20,"text":53,"correct":22},{"key":24,"text":55,"correct":26},[480,483,486,489,492,495],{"id":15,"name":481,"category":7,"favorite":482},"领导干部任职前廉政法规知识测试题",92,{"id":484,"name":485,"category":7,"favorite":15},595,"建筑结构与设备",{"id":487,"name":488,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":490,"name":491,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":493,"name":494,"category":7,"favorite":8},534,"BIM工程师",{"id":496,"name":494,"category":7,"favorite":8},535]