[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-31":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":444},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,31,50,2486,[13,28,34,40,56,62,74,86,92,104,116,127,133,139,145,151,157,163,181,187,193,205,211,217,232,238,244,259,265,271,283,295,307,313,319,325,331,337,343,349,355,361,375,381,387,393,399,414,426,432],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},974447,3,"判断题","电梯的迫降有紧急迫降按钮迫降、消防控制室远程控制迫降、自动联动控制迫降三种方法",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},974448,"防火卷帘按材质可分为钢质防火卷帘、无机纤维复合防火卷帘。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},974449,"发生火灾时，干式系统的闭式喷头受热开启，管道中的有压气体从喷头喷出，干式报警阀系统侧压力下降，造成干式报警阀水源侧压力大于系统侧压力，干式报警阀被自动打开，压力水进入供水管道",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":42,"typeLabel":43,"stem":44,"options":45,"answer":54,"analysis":27},974450,1,"单选题","关于线型光束感烟火灾探测器的选择，下列说法错误的是（ ）",[46,48,50,53],{"key":20,"text":47,"correct":26},"无遮挡的大空间或有特殊要求的房间，宜选择线型光束感烟火灾探测器",{"key":24,"text":49,"correct":26},"有大量粉尘、水雾滞留的场所，不宜选择线型光束感烟火灾探测器",{"key":51,"text":52,"correct":26},"C","在正常情况下有烟滞留的场所，不宜选择选择线型光束感烟火灾探测器",{"key":54,"text":55,"correct":22},"D","可能产生蒸气和油雾的场所，宜选择线型光束感烟火灾探测器",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":21,"analysis":27},974451,"消防应急广播系统主要由消防应急广播主机、功放机、分配盘、输出模块、音频线路及扬声器等组成。",[60,61],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":63,"libraryId":5,"type":42,"typeLabel":43,"stem":64,"options":65,"answer":51,"analysis":27},974452,"关于消防应急广播的基本功能，下列说法错误的是（ ）",[66,68,70,72],{"key":20,"text":67,"correct":26},"消防应急广播能手动检查本机音响器件、面板所有指示灯和显示器的功能",{"key":24,"text":69,"correct":26},"消防应急广播发生故障时，能在100s内发出故障声、光信号",{"key":51,"text":71,"correct":22},"录制疏散指令进行文件导入时，可同时播放系统内已有的指令",{"key":54,"text":73,"correct":26},"广播时，系统自动录音。",{"id":75,"libraryId":5,"type":42,"typeLabel":43,"stem":76,"options":77,"answer":54,"analysis":27},974453,"关于自动喷水灭火系统消防水泵的启动方式，说法错误的是（ ）",[78,80,82,84],{"key":20,"text":79,"correct":26},"消防水泵应能手动启停和自动启动",{"key":24,"text":81,"correct":26},"消防泵组电气控制柜开关处于手动位时，由控制柜面板启\u002F停按钮手动控制水泵启停",{"key":51,"text":83,"correct":26},"消防泵组电气控制柜开关处于自动位时，消防控制室总线能够联动启动",{"key":54,"text":85,"correct":22},"消防泵组电气控制柜开关处于手动位时，报警阀组压力开关能够启动",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":21,"analysis":27},974454,"为确保操作受控消防设备的可靠性，对于一些重要联动设备（如消防泵组、防烟和排烟风机）的控制，除采用联动控制方式外，火灾报警控制器还应采用多线控制盘控制方式，实现直接手动控制",[90,91],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":93,"libraryId":5,"type":42,"typeLabel":43,"stem":94,"options":95,"answer":54,"analysis":27},974455,"测试火灾显示盘功能时，下列操作错误的是（ ）",[96,98,100,102],{"key":20,"text":97,"correct":26},"利用火灾探测器加烟器向所辖区域内任意一只感烟火灾探测器加烟或直接按下手动火灾报警按钮报警，火灾显示盘应能接收火灾报警信号，指示火灾报警状态的红色指示灯点亮，并发出火灾报警声、光信号，显示火灾发生部位。",{"key":24,"text":99,"correct":26},"测试火灾显示盘消音功能。当模拟所辖区域内火灾报警或故障报警时，火灾显示盘应能接收信号，并发出火灾报警或故障报警声信号。",{"key":51,"text":101,"correct":26},"火灾显示盘发出火灾报警或故障报警声信号后，按下火灾显示盘消音键，可消除当前报警声，消音指示灯应点亮，也可按下火灾报警控制器消音键使火灾显示盘消音。",{"key":54,"text":103,"correct":22},"测试火灾显示盘复位功能。将拆卸的火灾探测器探头重新安装到底座上，消除探测器内及周围烟雾，更换或复位手动火灾报警按钮的启动零件，然后按下火灾显示盘复位键，火灾显示盘复位，恢复正常监视状态。",{"id":105,"libraryId":5,"type":42,"typeLabel":43,"stem":106,"options":107,"answer":24,"analysis":27},974456,"多线控制盘功能处于异常状态时，手动控制单元中故障指示灯处于（ ）状态。",[108,110,112,114],{"key":20,"text":109,"correct":26},"熄灭",{"key":24,"text":111,"correct":22},"黄色常亮",{"key":51,"text":113,"correct":26},"绿色常亮",{"key":54,"text":115,"correct":26},"红色常亮",{"id":117,"libraryId":5,"type":42,"typeLabel":43,"stem":118,"options":119,"answer":20,"analysis":27},974457,"普通电梯迫降，到达指定层后，其电梯状态为（ ）",[120,122,124,126],{"key":20,"text":121,"correct":22},"开门停用",{"key":24,"text":123,"correct":26},"开门待用",{"key":51,"text":125,"correct":26},"闭门待用",{"key":54,"text":125,"correct":26},{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":21,"analysis":27},974458,"当内部晶体管温度超过设定温度极限（90℃）6s后发生过温故障，消防应急广播系统过温灯指示灯应常亮",[131,132],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":25,"analysis":27},974459,"对于普通电梯，在火灾情况下，其迫降要求是使电梯返回到指定层（一般为首层）并保持“开门待用”的状态。",[137,138],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":21,"analysis":27},974460,"防火卷帘按帘面数量可分为单帘面防火卷帘和双帘面防火卷帘",[143,144],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":25,"analysis":27},974462,"消防电梯应在建筑物的管理中心或指定层提供一个电梯手动召回装置（也称消防开关）",[149,150],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":25,"analysis":27},974463,"消防应急广播主机是进行应急广播的主要设备，只能用于通告火灾报警信息、发出人员疏散语音指示及发生其他灾害与突发事件时发布有关指令的广播",[155,156],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":21,"analysis":27},974464,"消防应急照明和疏散指示系统是指为人员疏散和发生火灾时仍需工作的场所提供照明和疏散指示的系统",[161,162],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":164,"libraryId":5,"type":165,"typeLabel":166,"stem":167,"options":168,"answer":180,"analysis":27},974465,2,"多选题","下列组件，不属于湿式自动喷水灭火系统的是（ ）",[169,171,173,175,177],{"key":20,"text":170,"correct":22},"开式喷头",{"key":24,"text":172,"correct":22},"干式报警阀组",{"key":51,"text":174,"correct":26},"水流指示器",{"key":54,"text":176,"correct":26},"末端试水装置",{"key":178,"text":179,"correct":22},"E","充气设备","ABE",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":25,"analysis":27},974466,"湿式自动喷水灭火系统主要由开式喷头、湿式报警阀组、水流指示器、末端试水装置、管道和供水设施等组成",[185,186],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":25,"analysis":27},974467,"防排烟联动控制中，当防火分区内火灾确认后，应只开启该防火分区内着火层前室及合用前室的常闭送风口，同时开启加压送风机",[191,192],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":194,"libraryId":5,"type":42,"typeLabel":43,"stem":195,"options":196,"answer":54,"analysis":27},974468,"关于消防电话总机的功能，说法错误的是（ ）",[197,199,201,203],{"key":20,"text":198,"correct":26},"消防电话总机能为消防电话分机和消防电话插孔供电",{"key":24,"text":200,"correct":26},"可呼叫任意一部消防电话分机，并能同时呼叫至少两部消防电话分机",{"key":51,"text":202,"correct":26},"消防电话总机呼叫时能显示出被呼叫消防电话分机的状态和位置",{"key":54,"text":204,"correct":22},"收到消防电话分机呼叫时，声、光呼叫指示信号能手动消除",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":25,"analysis":27},974469,"干式系统可以使用普通下垂型喷头",[209,210],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":25,"analysis":27},974471,"自然通风方式的防烟系统是利用火灾产生的热烟气流的浮力和外部风力的作用，通过房间、走道的开口部位把烟气排至室外。",[215,216],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":218,"libraryId":5,"type":165,"typeLabel":166,"stem":219,"options":220,"answer":231,"analysis":27},974472,"关于集中火灾报警控制器、消防联动控制器的工作状态描述，下列说法正确的是（ ）",[221,223,225,227,229],{"key":20,"text":222,"correct":26},"当集中火灾报警控制器、消防联动控制器处于自动状态时，收到火灾报警信息时，会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，但不会联动启动声光报警、消防广播及所控制的现场消防设备",{"key":24,"text":224,"correct":22},"当集中火灾报警控制器、消防联动控制器处于手动状态时，收到火灾报警信息时，会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，但不会联动启动声光报警、消防广播及所控制的现场消防设备",{"key":51,"text":226,"correct":22},"当集中火灾报警控制器、消防联动控制器处于自动状态时，收到火灾报警信息时，不但会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，还会按照预设的逻辑关系联动启动声光报警、消防广播及所控制的现场消防设备",{"key":54,"text":228,"correct":26},"当集中火灾报警控制器、消防联动控制器处于手动状态时，收到火灾报警信息时，不但会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，还会按照预设的逻辑关系联动启动声光报警、消防广播及所控制的现场消防设备",{"key":178,"text":230,"correct":26},"当集中火灾报警控制器、消防联动控制器处于手动或自动状态时，收到火灾报警信息时，不但会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，还会按照预设的逻辑关系联动启动声光报警、消防广播及所控制的现场消防设备","BC",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},974473,"为确保消防水泵的可靠控制，适应消防水泵启动灭火、灾后控制以及维护保养的需求，消防水泵应能手动启停和自动启停。",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},974474,"消防应急广播系统在播放应急疏散指令时，拿起挂在主机上的话筒对着话筒即可广播紧急事项",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":165,"typeLabel":166,"stem":246,"options":247,"answer":258,"analysis":27},974475,"运行消防控制室图形显示装置软件，通过“报警历史记录查询”子菜单，可查询（ ）",[248,250,252,254,256],{"key":20,"text":249,"correct":22},"反馈及是否消除",{"key":24,"text":251,"correct":22},"火警",{"key":51,"text":253,"correct":22},"故障及是否恢复",{"key":54,"text":255,"correct":22},"启动及是否停止",{"key":178,"text":257,"correct":26},"操作和系统记录查询","ABCD",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":21,"analysis":27},974476,"消防电话总机在通话状态下可以允许或拒绝其他呼叫消防电话分机加人通话",[263,264],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":25,"analysis":27},974477,"由常开防火门所在防火分区内的两只感烟火灾探测器或一只感烟火灾探测器与一只手动火灾报警按钮的报警信号作为常开防火门关闭的联动触发信号。",[269,270],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":272,"libraryId":5,"type":42,"typeLabel":43,"stem":273,"options":274,"answer":20,"analysis":27},974478,"消防稳压设施的气压罐止气\u002F充气压力为（ ）",[275,277,279,281],{"key":20,"text":276,"correct":22},"p1",{"key":24,"text":278,"correct":26},"p2",{"key":51,"text":280,"correct":26},"p3",{"key":54,"text":282,"correct":26},"p4",{"id":284,"libraryId":5,"type":42,"typeLabel":43,"stem":285,"options":286,"answer":20,"analysis":27},974479,"判别现场消防设备工作状态时，回路配接设备在位图显示方式下，T表示（ ）",[287,289,291,293],{"key":20,"text":288,"correct":22},"报警类型",{"key":24,"text":290,"correct":26},"手动按钮",{"key":51,"text":292,"correct":26},"消火栓按钮",{"key":54,"text":294,"correct":26},"压力开关",{"id":296,"libraryId":5,"type":42,"typeLabel":43,"stem":297,"options":298,"answer":51,"analysis":27},974480,"相邻两组线型光束感烟火灾探测器的水平距离最大为（ ）",[299,301,303,305],{"key":20,"text":300,"correct":26},"10m",{"key":24,"text":302,"correct":26},"15m",{"key":51,"text":304,"correct":22},"14m",{"key":54,"text":306,"correct":26},"25m",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":21,"analysis":27},974481,"线型感温火灾探测器按敏感部件形式可分为缆式、空气管式、分布式光纤、光栅光纤和线式多点型线型感温探测器。",[311,312],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":21,"analysis":27},974482,"线型感温火灾探测器是指对某一连续线路周围温度和\u002F或温度变化响应的线型火灾探测器",[317,318],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":21,"analysis":27},974483,"线型火灾探测器是相对于点型火灾探测器而言的，是指连续探测某一路线周围火灾参数的火灾探测器，主要分为线型感烟火灾探测器和线型感温火灾探测器等类型",[323,324],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":21,"analysis":27},974484,"防排烟联动控制中，由排烟口、排烟窗或排烟阀开启的动作信号作为排烟风机启动的联动触发信号，并由消防联动控制器联动控制排烟风机的启动",[329,330],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":25,"analysis":27},974485,"集中火灾报警控制器的历史记录，包括火警记录、设备故障记录、请求记录、启动记录、反馈记录、操作记录、监管记录、气灭记录和其他故障记录，每种数量最多为5000条。",[335,336],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":25,"analysis":27},974486,"排烟系统主要有自然通风系统和机械排烟系统两种形式",[341,342],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":21,"analysis":27},974487,"设备信息查看一般分为设备查看、分类查看、分区查看三种方式。",[347,348],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":25,"analysis":27},974488,"测试火灾显示盘故障报警功能时。将具有故障显示功能的火灾显示盘所辖区域内任意一只感烟火灾探测器或感温火灾探测器从其底座上拆卸下来，火灾显示盘在火灾报警控制器发出故障信号后3s内发出故障声、光信号，指示故障发生部位，红色故障指示灯点亮，",[353,354],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":25,"analysis":27},974489,"多线控制盘操作面板上设有多个手动控制单元，每个单元包括一个操作按钮和启动、反馈两个状态指示灯",[359,360],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":362,"libraryId":5,"type":165,"typeLabel":166,"stem":363,"options":364,"answer":258,"analysis":27},974490,"历史记录包括（ ）",[365,367,369,371,373],{"key":20,"text":366,"correct":22},"火警记录",{"key":24,"text":368,"correct":22},"设备故障记录",{"key":51,"text":370,"correct":22},"反馈记录",{"key":54,"text":372,"correct":22},"气灭记录",{"key":178,"text":374,"correct":26},"维护保养记录",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":21,"analysis":27},974491,"一台集中火灾报警控制器（联动型）可以设置多个总线控制盘",[379,380],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":25,"analysis":27},974492,"火灾显示盘按供电方式分为三类：直流供电型、交流和直流\u002F交流通用供电型。",[385,386],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":21,"analysis":27},974493,"回路配接设备在列表显示方式下，第一列为回路-地址以及设备所在的X和Y分区。",[391,392],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":21,"analysis":27},974494,"防火卷帘卷门机上设有手动拉链，可通过人工拉动拉链控制卷帘升降。",[397,398],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":400,"libraryId":5,"type":165,"typeLabel":166,"stem":401,"options":402,"answer":413,"analysis":27},974495,"根据所安装喷头的结构形式，自动喷水灭火系统可分为（ ）",[403,405,407,409,411],{"key":20,"text":404,"correct":22},"闭式系统",{"key":24,"text":406,"correct":22},"开式系统",{"key":51,"text":408,"correct":26},"湿式系统",{"key":54,"text":410,"correct":26},"干式系统",{"key":178,"text":412,"correct":26},"预作用系统","AB",{"id":415,"libraryId":5,"type":42,"typeLabel":43,"stem":416,"options":417,"answer":51,"analysis":27},974496,"消防电梯紧急迫降按钮距地面的高度为（ ）m",[418,420,422,424],{"key":20,"text":419,"correct":26},"1.3-1.5",{"key":24,"text":421,"correct":26},"1.5-1.8",{"key":51,"text":423,"correct":22},"1.8-2.1",{"key":54,"text":425,"correct":26},"1.5-2",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":21,"analysis":27},974497,"消防泵组电气控制柜应具有将泵启、泵停、泵故障、手\u002F自动状态等信号反馈至消防控制室报警主机的功能。",[430,431],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":433,"libraryId":5,"type":42,"typeLabel":43,"stem":434,"options":435,"answer":20,"analysis":27},974498,"防火门监控器应在电动闭门器、电磁释放器或门磁开关动作后（ ）s内收到反馈信号",[436,438,440,442],{"key":20,"text":437,"correct":22},"10",{"key":24,"text":439,"correct":26},"15",{"key":51,"text":441,"correct":26},"20",{"key":54,"text":443,"correct":26},"30",[445,448,451,454,457,460],{"id":42,"name":446,"category":7,"favorite":447},"领导干部任职前廉政法规知识测试题",92,{"id":449,"name":450,"category":7,"favorite":42},595,"建筑结构与设备",{"id":452,"name":453,"category":7,"favorite":42},715,"招标采购专业知识与法律法规",{"id":455,"name":456,"category":7,"favorite":42},848,"市政方向-通用基础",{"id":458,"name":459,"category":7,"favorite":8},534,"BIM工程师",{"id":461,"name":459,"category":7,"favorite":8},535]