[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-30":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":528},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,30,50,2486,[13,34,42,54,66,76,86,96,108,117,129,147,162,177,192,207,222,237,250,264,278,292,307,321,332,346,358,368,374,380,386,392,398,404,410,416,422,428,434,440,446,460,466,480,486,492,498,504,510,516],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},974397,1,"单选题","防火门监控器应能接收来自火灾自动报警系统的火灾报警信号，并在（ ）s内向电动闭门器或电磁释放器发出启动信号，点亮启动总指示灯。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","10",false,{"key":24,"text":25,"correct":22},"B","20",{"key":27,"text":28,"correct":29},"C","30",true,{"key":31,"text":32,"correct":22},"D","50","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},974398,"防火门监控器应在电动闭门器、电磁释放器或门磁开关动作后（ ）s内收到反馈信号，并有反馈光指示，指示其名称或部位，反馈光指示应保持至受控设备恢复。",[38,39,40,41],{"key":20,"text":21,"correct":29},{"key":24,"text":25,"correct":22},{"key":27,"text":28,"correct":22},{"key":31,"text":32,"correct":22},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":27,"analysis":33},974399,"下列不属于集中电源集中控制型系统组成部分的是（ ）。",[46,48,50,52],{"key":20,"text":47,"correct":22},"应急照明集中控制器",{"key":24,"text":49,"correct":22},"应急照明集中电源",{"key":27,"text":51,"correct":29},"应急照明配电箱",{"key":31,"text":53,"correct":22},"集中电源集中控制型消防应急灯具",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":27,"analysis":33},974400,"应急照明控制器设置在消防控制室墙面上时，设备主显示屏高度宜为（ ）。",[58,60,62,64],{"key":20,"text":59,"correct":22},"1.2～1.3m",{"key":24,"text":61,"correct":22},"1.3～1.5m",{"key":27,"text":63,"correct":29},"1.5～1.8m",{"key":31,"text":65,"correct":22},"1.8～2.0m",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":24,"analysis":33},974401,"应急照明控制器接收到火灾报警控制器的火警信号后，应在（ ）s内发出系统自动应急启动信号，控制应急启动输出干接点动作。",[70,72,74,75],{"key":20,"text":71,"correct":22},"1",{"key":24,"text":73,"correct":29},"3",{"key":27,"text":21,"correct":22},{"key":31,"text":28,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":24,"analysis":33},974402,"下列不属于自带电源非集中控制型系统主要组成的是（ ）。",[80,81,82,84],{"key":20,"text":51,"correct":22},{"key":24,"text":47,"correct":29},{"key":27,"text":83,"correct":22},"消防应急灯具",{"key":31,"text":85,"correct":22},"配电线路",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":31,"analysis":33},974403,"应急照明控制器设置在消防控制室地面上，设备面板的排列长度大于（ ）m时，其两端应设置宽度不小于1m的通道。",[90,91,93,94],{"key":20,"text":71,"correct":22},{"key":24,"text":92,"correct":22},"2",{"key":27,"text":73,"correct":22},{"key":31,"text":95,"correct":29},"4",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":20,"analysis":33},974404,"所有消防应急灯具的工作状态都受应急照明集中控制器控制的系统是（ ）。",[100,102,104,106],{"key":20,"text":101,"correct":29},"集中电源集中控制型系统",{"key":24,"text":103,"correct":22},"集中电源非集中控制型系统",{"key":27,"text":105,"correct":22},"自带电源集中控制型系统",{"key":31,"text":107,"correct":22},"自带电源非集中控制型系统",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":24,"analysis":33},974405,"下列不属于自带电源集中控制型系统的组成部分的是（ ）。",[112,113,114,115],{"key":20,"text":47,"correct":22},{"key":24,"text":49,"correct":29},{"key":27,"text":51,"correct":22},{"key":31,"text":116,"correct":22},"自带电源集中控制型消防应急灯具",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":31,"analysis":33},974406,"下列关于消防电梯紧急迫降按钮设置要求不正确的是（ ）。",[121,123,125,127],{"key":20,"text":122,"correct":22},"在消防员入口层（一般为首层）的电梯前室内设置供消防员专用的操作按钮",{"key":24,"text":124,"correct":22},"通常设有保护装置",{"key":27,"text":126,"correct":22},"按钮应设置在距消防电梯水平距离2m以内的墙面上",{"key":31,"text":128,"correct":29},"按钮应设置在距地面高度1.5～1.8m的墙面上",{"id":130,"libraryId":5,"type":131,"typeLabel":132,"stem":133,"options":134,"answer":146,"analysis":33},974407,2,"多选题","下列属于消防电话系统组成部分的是（ ）。",[135,137,139,141,143],{"key":20,"text":136,"correct":29},"消防电话总机",{"key":24,"text":138,"correct":29},"消防电话分机",{"key":27,"text":140,"correct":29},"消防电话插孔",{"key":31,"text":142,"correct":29},"消防电话手柄",{"key":144,"text":145,"correct":29},"E","专用消防电话线路","ABCDE",{"id":148,"libraryId":5,"type":131,"typeLabel":132,"stem":149,"options":150,"answer":161,"analysis":33},974408,"下列关于消防电话总机的说法正确的是：（ ）。",[151,153,155,157,159],{"key":20,"text":152,"correct":29},"消防电话总机应能与所有消防分机电话之间互相呼叫与通话",{"key":24,"text":154,"correct":29},"处于通话状态的消防电话总机能呼叫任意一部及以上消防电话分机",{"key":27,"text":156,"correct":22},"消防电话总机能终止与任意消防电话分机的通话，同时终止与其他消防电话分机的通话",{"key":31,"text":158,"correct":22},"消防电话总机不能显示每部分机或电话插孔的位置",{"key":144,"text":160,"correct":29},"消防电话总机应能与所有电话插孔之间互相呼叫与通话","ABE",{"id":163,"libraryId":5,"type":131,"typeLabel":132,"stem":164,"options":165,"answer":176,"analysis":33},974409,"下列对消防电话总机工作状态指示灯的功能描述正确的有（ ）。",[166,168,170,172,174],{"key":20,"text":167,"correct":22},"通信灯：通话正常时点亮",{"key":24,"text":169,"correct":29},"故障灯：有故障时点亮",{"key":27,"text":171,"correct":22},"播放灯：播放音乐时点亮",{"key":31,"text":173,"correct":29},"通话灯：通话状态时点亮",{"key":144,"text":175,"correct":22},"电源灯：供电时熄灭","BD",{"id":178,"libraryId":5,"type":131,"typeLabel":132,"stem":179,"options":180,"answer":191,"analysis":33},974410,"下列关于消防应急广播主机、功放机的工作状态指示灯功能描述正确的有（ ）。",[181,183,185,187,189],{"key":20,"text":182,"correct":22},"当输出功率大于额定功率120%并持续3s后，过载指示灯点亮",{"key":24,"text":184,"correct":22},"当内部品体管温度超过设定温度极限（100℃）6s后发生过温故障，指示灯常亮",{"key":27,"text":186,"correct":29},"监听打开时监听灯常亮，关闭熄灭",{"key":31,"text":188,"correct":29},"消音灯平时熄灭，有故障时按下消音键常亮",{"key":144,"text":190,"correct":29},"对指示器件和报警声器件进行检查，按下自检灯常亮，检查完毕熄灭","CDE",{"id":193,"libraryId":5,"type":131,"typeLabel":132,"stem":194,"options":195,"answer":206,"analysis":33},974411,"下列属于消防应急广播的基本功能的有（ ）。",[196,198,200,202,204],{"key":20,"text":197,"correct":29},"应急广播功能",{"key":24,"text":199,"correct":29},"故障报警功能",{"key":27,"text":201,"correct":29},"自检功能",{"key":31,"text":203,"correct":29},"电源功能",{"key":144,"text":205,"correct":22},"反馈功能","ABCD",{"id":208,"libraryId":5,"type":131,"typeLabel":132,"stem":209,"options":210,"answer":221,"analysis":33},974412,"下列方式可控制自动排烟窗启动的是（ ）。",[211,213,215,217,219],{"key":20,"text":212,"correct":29},"现场手动操作",{"key":24,"text":214,"correct":29},"通过火灾自动报警系统自动启动",{"key":27,"text":216,"correct":29},"消防控制室手动操作",{"key":31,"text":218,"correct":22},"系统中任一排烟阀或排烟口开启时，自动排烟窗自动启动",{"key":144,"text":220,"correct":29},"通过温控释放装置启动","ABCE",{"id":223,"libraryId":5,"type":131,"typeLabel":132,"stem":224,"options":225,"answer":236,"analysis":33},974413,"下列方式可控制排烟防火阀关闭的有（ ）。",[226,228,230,232,234],{"key":20,"text":227,"correct":29},"温控自动关闭",{"key":24,"text":229,"correct":22},"消防控制室自动关闭",{"key":27,"text":231,"correct":29},"电动关闭",{"key":31,"text":233,"correct":29},"手动关闭",{"key":144,"text":235,"correct":22},"通过火灾自动报警系统自动关闭","ACD",{"id":238,"libraryId":5,"type":131,"typeLabel":132,"stem":239,"options":240,"answer":249,"analysis":33},974414,"下列方式可以控制排烟口、常闭送风口启动的有（ ）。",[241,243,244,246,248],{"key":20,"text":242,"correct":29},"现场手动启动",{"key":24,"text":214,"correct":29},{"key":27,"text":245,"correct":29},"消防控制室手动启动",{"key":31,"text":247,"correct":22},"系统中任一排烟阀或排烟口开启时，排烟口自动启动",{"key":144,"text":220,"correct":22},"ABC",{"id":251,"libraryId":5,"type":131,"typeLabel":132,"stem":252,"options":253,"answer":146,"analysis":33},974415,"下列属于风机电气控制柜的面板组成的有（ ）。",[254,256,258,260,262],{"key":20,"text":255,"correct":29},"电源指示灯",{"key":24,"text":257,"correct":29},"启动按钮",{"key":27,"text":259,"correct":29},"停止按钮",{"key":31,"text":261,"correct":29},"运行指示灯",{"key":144,"text":263,"correct":29},"手\u002F自动转换开关",{"id":265,"libraryId":5,"type":131,"typeLabel":132,"stem":266,"options":267,"answer":249,"analysis":33},974416,"下列对风机电气控制柜面板指示灯描述正确的是（ ）。",[268,270,272,274,276],{"key":20,"text":269,"correct":29},"电源指示灯，控制柜通电时点亮",{"key":24,"text":271,"correct":29},"运行指示灯，风机运转时点亮",{"key":27,"text":273,"correct":29},"手\u002F自动转换开关，通过开关指向指示当前风机处于手动或自动控制状",{"key":31,"text":275,"correct":22},"手\u002F自动转换开关，手动向自动转换时点亮",{"key":144,"text":277,"correct":22},"运行指示灯，风机运转时熄灭",{"id":279,"libraryId":5,"type":131,"typeLabel":132,"stem":280,"options":281,"answer":176,"analysis":33},974417,"下列能联动机械加压送风系统作为送风口开启和加压送风机启动的联动触发信号的是（ ）。",[282,284,286,288,290],{"key":20,"text":283,"correct":22},"加压送风口所在防烟分区内的两只独立火灾探测器报警信号",{"key":24,"text":285,"correct":29},"加压送风口所在防火分区内的两只独立火灾探测器报警信号",{"key":27,"text":287,"correct":22},"加压送风口所在防火分区内一只感温火灾探测器与一只感烟火灾探测器的报警信号",{"key":31,"text":289,"correct":29},"加压送风口所在防火分区内一只火灾探测器与一只手动火灾报警按钮的报警信号",{"key":144,"text":291,"correct":22},"加压送风口所在防烟分区内一只火灾探测器与一只手动火灾报警按钮的报警信号",{"id":293,"libraryId":5,"type":131,"typeLabel":132,"stem":294,"options":295,"answer":306,"analysis":33},974418,"下列需要采用防火门监控器上绿色指示灯用来指的是（ ）。",[296,298,300,302,304],{"key":20,"text":297,"correct":29},"电源工作状态",{"key":24,"text":299,"correct":22},"电动闭门器的动作信号",{"key":27,"text":301,"correct":22},"电磁释放器的动作信号",{"key":31,"text":303,"correct":22},"门磁开关的反馈信号",{"key":144,"text":305,"correct":29},"电磁释放器的反馈信号","AE",{"id":308,"libraryId":5,"type":131,"typeLabel":132,"stem":309,"options":310,"answer":206,"analysis":33},974419,"下列属于常开式防火门关闭方法的有（ ）。",[311,313,315,317,319],{"key":20,"text":312,"correct":29},"防火门监控器手动关闭",{"key":24,"text":314,"correct":29},"常开式防火门现场手动关闭",{"key":27,"text":316,"correct":29},"消防控制室远程手动关闭",{"key":31,"text":318,"correct":29},"联动自动关闭",{"key":144,"text":320,"correct":22},"温控释放控制",{"id":322,"libraryId":5,"type":131,"typeLabel":132,"stem":323,"options":324,"answer":331,"analysis":33},974420,"下列属于集中电源集中控制型系统组成部分的是（ ）。",[325,326,327,328,329],{"key":20,"text":51,"correct":22},{"key":24,"text":47,"correct":29},{"key":27,"text":49,"correct":29},{"key":31,"text":53,"correct":29},{"key":144,"text":330,"correct":29},"持续型消防应急灯具","BCDE",{"id":333,"libraryId":5,"type":131,"typeLabel":132,"stem":334,"options":335,"answer":331,"analysis":33},974421,"应急照明控制器在消防控制室墙面上设置时，应符合下列规定：（ ）。",[336,338,340,342,344],{"key":20,"text":337,"correct":22},"设备主显示屏高度为1.3m",{"key":24,"text":339,"correct":29},"设备主显示屏高度为1.8m",{"key":27,"text":341,"correct":29},"设备正面操作距离为1.5m",{"key":31,"text":343,"correct":29},"设备靠近门轴的侧面距墙为0.5m",{"key":144,"text":345,"correct":29},"设备靠近门轴的侧面距墙为1.0m",{"id":347,"libraryId":5,"type":131,"typeLabel":132,"stem":348,"options":349,"answer":221,"analysis":33},974422,"消防电梯紧急迫降按钮设置要求：（ ）。",[350,351,352,354,356],{"key":20,"text":122,"correct":29},{"key":24,"text":124,"correct":29},{"key":27,"text":353,"correct":29},"按钮应设置在距消防电梯水平距离1.5m的墙面上",{"key":31,"text":355,"correct":22},"按钮应设置在距地面高度1.5m的墙面上",{"key":144,"text":357,"correct":29},"按钮应设置在距地面高度2m的墙面上",{"id":359,"libraryId":5,"type":360,"typeLabel":361,"stem":362,"options":363,"answer":367,"analysis":33},974423,3,"判断题","处于通话状态的消防电话总机，当有其他消防电话分机呼入时，会提示通话正忙。",[364,366],{"key":20,"text":365,"correct":22},"正确",{"key":24,"text":367,"correct":29},"错误",{"id":369,"libraryId":5,"type":360,"typeLabel":361,"stem":370,"options":371,"answer":367,"analysis":33},974424,"当确认火灾后，消防联动控制器应发出联动控制信号强制所有电梯停于首层或电梯转换层并切断所有电梯的电源。",[372,373],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":375,"libraryId":5,"type":360,"typeLabel":361,"stem":376,"options":377,"answer":365,"analysis":33},974425,"消防电话总机有录音功能，进行通话时，录音自动开始，并有光信号指示，通话结束，录音自动停止。",[378,379],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":381,"libraryId":5,"type":360,"typeLabel":361,"stem":382,"options":383,"answer":365,"analysis":33},974426,"消防应急广播系统可仅对所选择区域进行广播",[384,385],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":387,"libraryId":5,"type":360,"typeLabel":361,"stem":388,"options":389,"answer":367,"analysis":33},974427,"消防应急广播系统的线路可与通风空调线路同槽敷设。",[390,391],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":393,"libraryId":5,"type":360,"typeLabel":361,"stem":394,"options":395,"answer":367,"analysis":33},974428,"消防应急广播能按预定程序向保护区域广播火灾事故有关信息，广播语音清晰，距扬声器正前方3m处应急广播的播放声压级不小于70dB，且不大于115dB。",[396,397],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":399,"libraryId":5,"type":360,"typeLabel":361,"stem":400,"options":401,"answer":367,"analysis":33},974429,"当消防应急广播主机输出功率大于额定功率120%并持续3s后，过载指示灯点亮。",[402,403],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":405,"libraryId":5,"type":360,"typeLabel":361,"stem":406,"options":407,"answer":365,"analysis":33},974430,"消防应急广播系统播放时能自动录音。",[408,409],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":411,"libraryId":5,"type":360,"typeLabel":361,"stem":412,"options":413,"answer":367,"analysis":33},974431,"防火卷帘具有现场手动电控、自动控制、消防控制室远程手动控制三种主要控制方式。",[414,415],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":417,"libraryId":5,"type":360,"typeLabel":361,"stem":418,"options":419,"answer":367,"analysis":33},974432,"对于疏散通道上设置的防火卷帘，由防火分区内任两只独立的感烟火灾探测器或任一只专门用于联动防火卷帘的感烟火灾探测器的报警信号联动控制防火卷帘下降到楼板面。",[420,421],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":423,"libraryId":5,"type":360,"typeLabel":361,"stem":424,"options":425,"answer":367,"analysis":33},974433,"对于非疏散通道上设置的防火卷帘，由防火卷帘所在防火分区内任两只独立的感烟火灾探测器的报警信号作为防火卷帘下降的联动触发信号，联动控制防火卷帘直接下降到楼板面。",[426,427],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":429,"libraryId":5,"type":360,"typeLabel":361,"stem":430,"options":431,"answer":365,"analysis":33},974434,"通过消防控制室消防联动控制器可手动控制防火卷帘的降落。",[432,433],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":435,"libraryId":5,"type":360,"typeLabel":361,"stem":436,"options":437,"answer":367,"analysis":33},974435,"防火门处于故障状态时，总指示灯应点亮并发出声光报警信号。声信号的声压级（正前方1m处）应为65-85dB。故障声信号每分钟至少提示1次，每次持续时间应为3-5S。",[438,439],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":441,"libraryId":5,"type":360,"typeLabel":361,"stem":442,"options":443,"answer":367,"analysis":33},974436,"防火门监控器应能记录与其连接的防火门的状态信息（包括防火门地址，开、闭和故障状态及相应的时间等），记录容量不应少于12000条。",[444,445],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":447,"libraryId":5,"type":131,"typeLabel":132,"stem":448,"options":449,"answer":221,"analysis":33},974437,"下列属于风机电气控制柜的应具备的功能有（ ）。",[450,452,454,456,458],{"key":20,"text":451,"correct":29},"指示功能",{"key":24,"text":453,"correct":29},"转换功能",{"key":27,"text":455,"correct":29},"风机启\u002F停功能",{"key":31,"text":457,"correct":22},"报警功能",{"key":144,"text":459,"correct":29},"其他功能",{"id":461,"libraryId":5,"type":360,"typeLabel":361,"stem":462,"options":463,"answer":367,"analysis":33},974438,"消防电话分机、电话插孔的呼叫灯，监视状态下熄灭，呼叫时常亮，通话时闪亮",[464,465],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":467,"libraryId":5,"type":131,"typeLabel":132,"stem":468,"options":469,"answer":249,"analysis":33},974439,"下列哪些设备的动作信号，可以作为启动消防水泵的信号（ ）",[470,472,474,476,478],{"key":20,"text":471,"correct":29},"消防水箱出水管上的流量开关",{"key":24,"text":473,"correct":29},"消防水泵出水干管上的压力开关",{"key":27,"text":475,"correct":29},"报警阀组的压力开关",{"key":31,"text":477,"correct":22},"水流指示器",{"key":144,"text":479,"correct":22},"信号阀",{"id":481,"libraryId":5,"type":360,"typeLabel":361,"stem":482,"options":483,"answer":365,"analysis":33},974440,"消防电话总机应能与所有消防分机电话、电话插孔之间互相呼叫与通话，并显示每部分机或电话插孔的位置。",[484,485],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":487,"libraryId":5,"type":360,"typeLabel":361,"stem":488,"options":489,"answer":367,"analysis":33},974441,"线型光束感烟火灾探测器分为激光光束线型感烟火灾探测器和红外光束线型感烟火灾探测器两种类型，目前广泛使用的是激光光束线型感烟火灾探测器",[490,491],{"key":20,"text":365,"correct":22},{"key":24,"text":367,"correct":29},{"id":493,"libraryId":5,"type":360,"typeLabel":361,"stem":494,"options":495,"answer":365,"analysis":33},974442,"干式报警阀自动打开后，压力水进入供水管道，将剩余压缩空气从系统立管顶端或横干管最高处的排气阀或已打开的喷头处喷出",[496,497],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":499,"libraryId":5,"type":360,"typeLabel":361,"stem":500,"options":501,"answer":365,"analysis":33},974443,"防火门按日常启闭状态可分为常闭式防火门和常开式防火门",[502,503],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":505,"libraryId":5,"type":360,"typeLabel":361,"stem":506,"options":507,"answer":365,"analysis":33},974444,"当集中火灾报警控制器处于监控状态时，在系统菜单的操作页面下，按上、下键移动光标选中手\u002F自动切换选项，或者直接按下手\u002F自动切换选项对应的快捷数字键，输入系统操作密码后按确认键，控制器将从手动状态切换为自动状态。",[508,509],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":511,"libraryId":5,"type":360,"typeLabel":361,"stem":512,"options":513,"answer":365,"analysis":33},974445,"消防应急广播系统是火灾情况下用于通告火灾报警信息、发出人员疏散语音指示及发生其他灾害与突发事件时发布有关指令的广播设备",[514,515],{"key":20,"text":365,"correct":29},{"key":24,"text":367,"correct":22},{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":24,"analysis":33},974446,"下列关于线型光束感烟火灾探测器的说法，错误的是（ ）",[520,522,524,526],{"key":20,"text":521,"correct":22},"线型光束感烟火灾探测器包括发射器和接收器两部分",{"key":24,"text":523,"correct":29},"当探测器光路上出现烟雾时，会使到达接收器的信号增强",{"key":27,"text":525,"correct":22},"目前广泛使用的是红外光束线型感烟火灾探测器",{"key":31,"text":527,"correct":22},"红外光束线型感烟火灾探测器分为对射型和反射型两种",[529,532,535,538,541,544],{"id":15,"name":530,"category":7,"favorite":531},"领导干部任职前廉政法规知识测试题",92,{"id":533,"name":534,"category":7,"favorite":15},595,"建筑结构与设备",{"id":536,"name":537,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":539,"name":540,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":542,"name":543,"category":7,"favorite":8},534,"BIM工程师",{"id":545,"name":543,"category":7,"favorite":8},535]