[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":481},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,29,50,2486,[13,38,53,68,83,98,108,114,120,126,132,138,144,150,156,162,168,174,180,186,192,198,204,210,216,222,228,234,240,246,252,258,272,284,299,311,323,335,347,359,370,380,392,400,410,422,433,445,457,469],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},974345,2,"多选题","迫降功能启动后，电梯与同一组群中的其他电梯关系描述正确的是（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","普通电梯，电梯组中的一台电梯发生故障，同组电梯停止运行",false,{"key":24,"text":25,"correct":26},"B","普通电梯，电梯组中的一台电梯发生故障，不影响其他电梯向指定层的运行",true,{"key":28,"text":29,"correct":22},"C","消防电梯，电梯组中的一台电梯发生故障，不影响其他电梯向指定层的运行",{"key":31,"text":32,"correct":26},"D","消防电梯脱离同一组群中的所有其他电梯独立运行",{"key":34,"text":35,"correct":26},"E","到达指定层后，普通电梯“开门停用“，消防电梯“开门待用”。","BDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},974347,"应急照明控制器在消防控制室地面上设置时，应符合下列规定：（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"单列布置时设备面板前的操作距离为1.5m",{"key":24,"text":45,"correct":22},"在值班人员经常工作的一面，设备面板至墙的距离不应小于3m",{"key":28,"text":47,"correct":22},"设备面板后的维修距离不宜小于2m",{"key":31,"text":49,"correct":26},"设备面板的排列长度大于4m时，其两端应设置宽度不小于1m的通道",{"key":34,"text":51,"correct":26},"双列布置时设备面板前的操作距离为1.5m","ADE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},974348,"下列属于消防应急照明和疏散指示系统的类型选择的因素是（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":26},"建\u002F构筑物的规模",{"key":24,"text":60,"correct":26},"使用性质",{"key":28,"text":62,"correct":26},"日常管理及维护难易程度",{"key":31,"text":64,"correct":22},"建筑面积",{"key":34,"text":66,"correct":22},"建筑的高度","ABC",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},974349,"关于消防应急灯具的分类正确的是：（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"按用途分为消防应急标志灯具、消防应急照明灯具、消防应急照明标志复合灯具。",{"key":24,"text":75,"correct":22},"按应急控制方式分为持续型消防应急灯具、非持续型消防应急灯具。",{"key":28,"text":77,"correct":26},"按应急供电方式分为自带电源型消防应急灯具、集中电源型消防应急灯具、子母型消防应急灯具。",{"key":31,"text":79,"correct":22},"按工作方式分为集中控制型消防应急灯具、非集中控制型消防应急灯具。",{"key":34,"text":81,"correct":22},"按控制方式分为集中控制型系统和非集中控制型系统","AC",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":97,"analysis":37},974350,"下列关于应急照明控制系统自动控制系统的应急启动，应急照明控制器接收到火灾报警控制器的火警信号后的说法正确的是（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":26},"应在3s内发出系统自动应急启动信号",{"key":24,"text":90,"correct":26},"控制应急启动输出干接点动作",{"key":28,"text":92,"correct":26},"发出启动声光信号",{"key":31,"text":94,"correct":26},"显示并记录系统应急启动类型和系统应急启动时间",{"key":34,"text":96,"correct":22},"应在10s内发出系统自动应急启动信号","ABCD",{"id":99,"libraryId":5,"type":100,"typeLabel":101,"stem":102,"options":103,"answer":107,"analysis":37},974351,3,"判断题","消防电话系统由消防电话总机、消防电话分机、消防电话插孔、消防电话手柄组成。",[104,106],{"key":20,"text":105,"correct":22},"正确",{"key":24,"text":107,"correct":26},"错误",{"id":109,"libraryId":5,"type":100,"typeLabel":101,"stem":110,"options":111,"answer":107,"analysis":37},974352,"消防电话系统分为单线制和多线制两种形式。",[112,113],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":115,"libraryId":5,"type":100,"typeLabel":101,"stem":116,"options":117,"answer":107,"analysis":37},974353,"消防电话总机能终止与任意消防电话分机的通话，与其他消防电话分机的通话同时终止。",[118,119],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":121,"libraryId":5,"type":100,"typeLabel":101,"stem":122,"options":123,"answer":107,"analysis":37},974354,"为迅速实现对火灾的人工确认，现场人员要熟记消防总机号码。",[124,125],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":127,"libraryId":5,"type":100,"typeLabel":101,"stem":128,"options":129,"answer":107,"analysis":37},974355,"收到消防电话分机呼叫时，消防电话总机在10s内发出声、光呼叫指示信号，指示该消防电话分机为呼叫状态，声指示信号能手动消除。",[130,131],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":133,"libraryId":5,"type":100,"typeLabel":101,"stem":134,"options":135,"answer":107,"analysis":37},974356,"消防电话总机有录音功能，进行通话时，按下录音按键，录音自动开始。",[136,137],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":139,"libraryId":5,"type":100,"typeLabel":101,"stem":140,"options":141,"answer":107,"analysis":37},974357,"当防火分区内火灾确认后，应能在15s内联动开启常闭加压送风口和加压送风机，并应开启该防火分区楼梯间的全部加压送风机",[142,143],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":145,"libraryId":5,"type":100,"typeLabel":101,"stem":146,"options":147,"answer":107,"analysis":37},974358,"当防火分区内火灾确认后，应能在5s内联动开启常闭加压送风口和加压送风机，并应开启该防火分区楼梯间的全部加压送风机",[148,149],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":151,"libraryId":5,"type":100,"typeLabel":101,"stem":152,"options":153,"answer":107,"analysis":37},974359,"机械排烟系统应与火灾自动报警系统联动，由同一防火分区内的两只独立火灾探测器的报警信号作为排烟口、排烟窗或排烟阀开启的联动触发信号，并由消防联动控制器联动控制排烟口、排烟窗或排烟阀的开启，同时停止该防烟分区的空气调节系统。",[154,155],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":157,"libraryId":5,"type":100,"typeLabel":101,"stem":158,"options":159,"answer":107,"analysis":37},974360,"担负两个及以上防烟分区的排烟系统，应打开着火防烟分区及相邻防烟分区的排烟阀或排烟口。",[160,161],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":163,"libraryId":5,"type":100,"typeLabel":101,"stem":164,"options":165,"answer":107,"analysis":37},974361,"系统中任一常闭加压送风口开启时，加压风机联动启动。",[166,167],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":169,"libraryId":5,"type":100,"typeLabel":101,"stem":170,"options":171,"answer":107,"analysis":37},974362,"消防控制室可手动关闭排烟防火阀。",[172,173],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":175,"libraryId":5,"type":100,"typeLabel":101,"stem":176,"options":177,"answer":105,"analysis":37},974363,"挡烟垂壁可现场手动启动，也可通过火灾自动报警系统自动启动。",[178,179],{"key":20,"text":105,"correct":26},{"key":24,"text":107,"correct":22},{"id":181,"libraryId":5,"type":100,"typeLabel":101,"stem":182,"options":183,"answer":107,"analysis":37},974364,"火场大于环境温度20℃时，温控释放装置动作，自动排烟窗启动。",[184,185],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":187,"libraryId":5,"type":100,"typeLabel":101,"stem":188,"options":189,"answer":105,"analysis":37},974365,"用于竖向分隔的防火卷帘（中庭）应在一侧（内侧）设置火灾探测器组。",[190,191],{"key":20,"text":105,"correct":26},{"key":24,"text":107,"correct":22},{"id":193,"libraryId":5,"type":100,"typeLabel":101,"stem":194,"options":195,"answer":105,"analysis":37},974366,"用于防火分隔的防火卷帘控制器的另一侧应安装手动控制装置。",[196,197],{"key":20,"text":105,"correct":26},{"key":24,"text":107,"correct":22},{"id":199,"libraryId":5,"type":100,"typeLabel":101,"stem":200,"options":201,"answer":105,"analysis":37},974367,"用于疏散通道上的防火卷帘和横向分隔防火分区的防火卷帘，其两侧均应设置火灾探测器组。",[202,203],{"key":20,"text":105,"correct":26},{"key":24,"text":107,"correct":22},{"id":205,"libraryId":5,"type":100,"typeLabel":101,"stem":206,"options":207,"answer":107,"analysis":37},974368,"防火卷帘按材质可分为钢质防火卷帘和无机纤维复合防火卷帘。",[208,209],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":211,"libraryId":5,"type":100,"typeLabel":101,"stem":212,"options":213,"answer":107,"analysis":37},974369,"特级防火卷帘可以应用于防火分隔部位，代替防火墙或防火隔墙。",[214,215],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":217,"libraryId":5,"type":100,"typeLabel":101,"stem":218,"options":219,"answer":107,"analysis":37},974370,"防火卷帘按材质方式可分为垂直式防火卷帘、侧向式防火卷帘、水平式防火卷帘。",[220,221],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":223,"libraryId":5,"type":100,"typeLabel":101,"stem":224,"options":225,"answer":107,"analysis":37},974371,"防火门监控器上黄色指示灯用于指示电源工作状态和电磁释放器的反馈信号。",[226,227],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":229,"libraryId":5,"type":100,"typeLabel":101,"stem":230,"options":231,"answer":107,"analysis":37},974373,"防火门监控器上绿色指示灯用于指示启动信号、电动闭门器和电磁释放器的动作信号及门磁开关的反馈信号。",[232,233],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":235,"libraryId":5,"type":100,"typeLabel":101,"stem":236,"options":237,"answer":107,"analysis":37},974374,"常开式防火门可温控释放控制关闭。",[238,239],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":241,"libraryId":5,"type":100,"typeLabel":101,"stem":242,"options":243,"answer":107,"analysis":37},974375,"自动联动控制迫降由火灾自动报警系统确认火灾后，自动联动控制消防电梯转入迫降或消防工作状态。电梯运行状态信息和停于首层或转换层的反馈信号，应传送给消防控制室显示。",[244,245],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":247,"libraryId":5,"type":100,"typeLabel":101,"stem":248,"options":249,"answer":107,"analysis":37},974376,"消防电梯迫降要求是使电梯返回到指定层（一般为首层）并保持“开门停用”的状态。",[250,251],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":253,"libraryId":5,"type":100,"typeLabel":101,"stem":254,"options":255,"answer":107,"analysis":37},974377,"迫降功能启动后，普通电梯，井道和机房照明自动点亮，电梯组中的一台电梯发生故障，不影响其他电梯向指定层的运行。",[256,257],{"key":20,"text":105,"correct":22},{"key":24,"text":107,"correct":26},{"id":259,"libraryId":5,"type":260,"typeLabel":261,"stem":262,"options":263,"answer":28,"analysis":37},974378,1,"单选题","当消防应急广播主机内部品体管温度超过设定温度极限（90℃）（ ）s后发生过温故障，过温指示灯常亮。",[264,266,268,270],{"key":20,"text":265,"correct":22},"1",{"key":24,"text":267,"correct":22},"3",{"key":28,"text":269,"correct":26},"6",{"key":31,"text":271,"correct":22},"10",{"id":273,"libraryId":5,"type":260,"typeLabel":261,"stem":274,"options":275,"answer":20,"analysis":37},974379,"下列关于防火门监控器故障报警功能描述不正确的是（ ）。",[276,278,280,282],{"key":20,"text":277,"correct":26},"防火门处于故障状态时，总指示灯应闪亮并发出声光报警信号",{"key":24,"text":279,"correct":22},"声信号的声压级（正前方1m处）为80dB",{"key":28,"text":281,"correct":22},"故障声信号每分钟提示1次",{"key":31,"text":283,"correct":22},"故障声信号每次持续时间应为2s",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":298,"analysis":37},974380,"下列关于防火门监控器故障报警功能描述正确的是（ ）。",[288,290,292,294,296],{"key":20,"text":289,"correct":22},"防火门处于故障状态时，总指示灯应点亮，并发出声报警信号",{"key":24,"text":291,"correct":26},"声信号的声压级（正前方1m处）为70dB",{"key":28,"text":293,"correct":26},"故障声信号每分钟提示3次",{"key":31,"text":295,"correct":22},"故障声信号每次持续时间应为5s",{"key":34,"text":297,"correct":26},"故障声信号的声压级（正前方1m处）85dB","BCE",{"id":300,"libraryId":5,"type":260,"typeLabel":261,"stem":301,"options":302,"answer":24,"analysis":37},974381,"下列关于消防电话总机的说法不正确的是（ ）。",[303,305,307,309],{"key":20,"text":304,"correct":22},"消防电话总机应能与所有消防分机电话、电话插孔之间互相呼叫与通话",{"key":24,"text":306,"correct":26},"处于通话状态的消防电话总机挂机后，能呼叫任意一部及以上消防电话分机",{"key":28,"text":308,"correct":22},"消防电话总机能终止与任意消防电话分机的通话，且不影响与其他消防电话分机的通话",{"key":31,"text":310,"correct":22},"被呼叫的消防电话分机摘机后，能自动加入通话",{"id":312,"libraryId":5,"type":260,"typeLabel":261,"stem":313,"options":314,"answer":31,"analysis":37},974382,"下列对消防电话总机工作状态指示灯的功能描述不正确的是（ ）。",[315,317,319,321],{"key":20,"text":316,"correct":22},"通信灯：通信正常时点亮",{"key":24,"text":318,"correct":22},"故障灯：有故障时点亮",{"key":28,"text":320,"correct":22},"播放灯：播放录音时点亮",{"key":31,"text":322,"correct":26},"录音灯：录音空间不足时点亮",{"id":324,"libraryId":5,"type":260,"typeLabel":261,"stem":325,"options":326,"answer":24,"analysis":37},974383,"收到消防电话分机呼叫时，消防电话总机在（ ）内发出声、光呼叫指示信号，指示该消防电话分机为呼叫状态，声指示信号能手动消除。",[327,329,331,333],{"key":20,"text":328,"correct":22},"1s",{"key":24,"text":330,"correct":26},"3s",{"key":28,"text":332,"correct":22},"5s",{"key":31,"text":334,"correct":22},"10s",{"id":336,"libraryId":5,"type":260,"typeLabel":261,"stem":337,"options":338,"answer":28,"analysis":37},974384,"当消防应急广播主机输出功率大于额定功率（ ）并持续2s后，过载指示灯点亮。",[339,341,343,345],{"key":20,"text":340,"correct":22},"80%",{"key":24,"text":342,"correct":22},"100%",{"key":28,"text":344,"correct":26},"120%",{"key":31,"text":346,"correct":22},"150%",{"id":348,"libraryId":5,"type":260,"typeLabel":261,"stem":349,"options":350,"answer":28,"analysis":37},974385,"消防应急广播主机、功放机的工作状态指示灯功能描述不正确的是：（ ）",[351,353,355,357],{"key":20,"text":352,"correct":22},"当输出功率大于额定功率120%并持续2s后，过载指示灯点亮",{"key":24,"text":354,"correct":22},"当内部品体管温度超过设定温度极限（90℃）6s后发生过温故障，指示灯常亮",{"key":28,"text":356,"correct":26},"对指示器件和报警声器件进行检查，自检灯常亮",{"key":31,"text":358,"correct":22},"消音灯平时熄灭，有故障时按下消音键常亮",{"id":360,"libraryId":5,"type":260,"typeLabel":261,"stem":361,"options":362,"answer":31,"analysis":37},974386,"消防应急广播发生故障时，能在（ ）s内发出故障声、光信号。",[363,364,366,368],{"key":20,"text":271,"correct":22},{"key":24,"text":365,"correct":22},"30",{"key":28,"text":367,"correct":22},"50",{"key":31,"text":369,"correct":26},"100",{"id":371,"libraryId":5,"type":260,"typeLabel":261,"stem":372,"options":373,"answer":20,"analysis":37},974387,"当消防应急广播主机输出功率大于额定功率120%并持续（ ）s后，过载指示灯点亮。",[374,376,377,379],{"key":20,"text":375,"correct":26},"2",{"key":24,"text":267,"correct":22},{"key":28,"text":378,"correct":22},"5",{"key":31,"text":271,"correct":22},{"id":381,"libraryId":5,"type":260,"typeLabel":261,"stem":382,"options":383,"answer":28,"analysis":37},974388,"下列不属于消防应急广播功能的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":22},"应急广播功能",{"key":24,"text":387,"correct":22},"故障报警功能",{"key":28,"text":389,"correct":26},"巡检功能",{"key":31,"text":391,"correct":22},"电源功能",{"id":393,"libraryId":5,"type":260,"typeLabel":261,"stem":394,"options":395,"answer":24,"analysis":37},974389,"消防应急广播能按预定程序向保护区域广播火灾事故有关信息，广播语音清晰，距扬声器正前方（ ）m处应急广播的播放声压级不小于65d B，且不大于115dB。",[396,397,398,399],{"key":20,"text":375,"correct":22},{"key":24,"text":267,"correct":26},{"key":28,"text":378,"correct":22},{"key":31,"text":271,"correct":22},{"id":401,"libraryId":5,"type":260,"typeLabel":261,"stem":402,"options":403,"answer":24,"analysis":37},974390,"当火灾确认后，火灾自动报警系统应在（ ）s内联动开启相应防烟分区的全部排烟阀、排烟口、排烟风机和补风设施，并在30s内自动关闭与排烟无关的通风、空调系统。",[404,405,407,408],{"key":20,"text":271,"correct":22},{"key":24,"text":406,"correct":26},"15",{"key":28,"text":365,"correct":22},{"key":31,"text":409,"correct":22},"60",{"id":411,"libraryId":5,"type":260,"typeLabel":261,"stem":412,"options":413,"answer":31,"analysis":37},974391,"下列方式不能控制排烟风机启动的是（ ）。",[414,416,418,420],{"key":20,"text":415,"correct":22},"现场手动启动。",{"key":24,"text":417,"correct":22},"通过火灾自动报警系统自动启动",{"key":28,"text":419,"correct":22},"消防控制室手动启动",{"key":31,"text":421,"correct":26},"系统指定的排烟阀或排烟口开启时，排烟风机自动启动",{"id":423,"libraryId":5,"type":260,"typeLabel":261,"stem":424,"options":425,"answer":31,"analysis":37},974392,"下列方式不能控制挡烟垂壁的是（ ）。",[426,428,430,432],{"key":20,"text":427,"correct":22},"现场手动操作",{"key":24,"text":429,"correct":22},"挡烟垂壁接收到消防控制中心的控制信号后下降至挡烟工作位置",{"key":28,"text":431,"correct":22},"当配接的烟感探测器报警后，挡烟垂壁自动下降至挡烟工作位置",{"key":31,"text":419,"correct":26},{"id":434,"libraryId":5,"type":260,"typeLabel":261,"stem":435,"options":436,"answer":31,"analysis":37},974393,"下列不属于风机电气控制柜的面板的组成部分的是（ ）。",[437,439,441,443],{"key":20,"text":438,"correct":22},"电源指示灯",{"key":24,"text":440,"correct":22},"启动按钮",{"key":28,"text":442,"correct":22},"手\u002F自动转换开关",{"key":31,"text":444,"correct":26},"主备电源转换开关",{"id":446,"libraryId":5,"type":260,"typeLabel":261,"stem":447,"options":448,"answer":20,"analysis":37},974394,"下列关于机械排烟系统与火灾自动报警系统联动作为排烟口、排烟窗或排烟阀开启的联动触发信号的是（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":26},"由同一防烟分区内的两只独立火灾探测器的报警信号",{"key":24,"text":452,"correct":22},"由同一防火分区内的两只独立火灾探测器的报警信号",{"key":28,"text":454,"correct":22},"由防火分区内一只感温火灾探测器与一只感烟火灾探测器的报警信号",{"key":31,"text":456,"correct":22},"由防烟分区内一只火灾探测器与一只手动火灾报警按钮的报警信号",{"id":458,"libraryId":5,"type":260,"typeLabel":261,"stem":459,"options":460,"answer":31,"analysis":37},974395,"下列不属于防火门监控系统组成部分的是（ ）。",[461,463,465,467],{"key":20,"text":462,"correct":22},"监控器",{"key":24,"text":464,"correct":22},"电动闭门器",{"key":28,"text":466,"correct":22},"电磁释放器",{"key":31,"text":468,"correct":26},"火灾报警控制器",{"id":470,"libraryId":5,"type":260,"typeLabel":261,"stem":471,"options":472,"answer":24,"analysis":37},974396,"下列不属于防火门监控器功能的是（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":22},"显示",{"key":24,"text":476,"correct":26},"呼叫",{"key":28,"text":478,"correct":22},"故障报警",{"key":31,"text":480,"correct":22},"信息记录、查询与上传",[482,485,488,491,494,497],{"id":260,"name":483,"category":7,"favorite":484},"领导干部任职前廉政法规知识测试题",92,{"id":486,"name":487,"category":7,"favorite":260},595,"建筑结构与设备",{"id":489,"name":490,"category":7,"favorite":260},715,"招标采购专业知识与法律法规",{"id":492,"name":493,"category":7,"favorite":260},848,"市政方向-通用基础",{"id":495,"name":496,"category":7,"favorite":8},534,"BIM工程师",{"id":498,"name":496,"category":7,"favorite":8},535]