[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":629},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,28,50,2486,[13,38,48,54,60,66,81,92,104,116,128,140,152,164,176,188,200,212,224,236,247,259,271,283,295,307,319,327,339,351,363,375,387,402,417,432,443,458,470,482,496,510,520,534,545,559,571,585,600,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},974295,2,"多选题","下列属于消防增（稳）压设施组成部件的有（ ）",[19,23,26,29,32],{"key":20,"text":21,"correct":22},"A","泵组",true,{"key":24,"text":25,"correct":22},"B","管道阀门及附件",{"key":27,"text":28,"correct":22},"C","测控仪表",{"key":30,"text":31,"correct":22},"D","操控柜",{"key":33,"text":34,"correct":35},"E","压力开关",false,"ABCD","",{"id":39,"libraryId":5,"type":40,"typeLabel":41,"stem":42,"options":43,"answer":47,"analysis":37},974296,3,"判断题","干式系统喷头开启后管道排气充水后出水，效率高于湿式系统。",[44,46],{"key":20,"text":45,"correct":35},"正确",{"key":24,"text":47,"correct":22},"错误",{"id":49,"libraryId":5,"type":40,"typeLabel":41,"stem":50,"options":51,"answer":47,"analysis":37},974297,"通过消防控制室总线联动高位消防水箱出水管流量开关、报阀组压力开关和消防水泵出水干管压力开关，可自动启停消防水泵。",[52,53],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":55,"libraryId":5,"type":40,"typeLabel":41,"stem":56,"options":57,"answer":47,"analysis":37},974298,"消防水泵可自动启停。",[58,59],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":61,"libraryId":5,"type":40,"typeLabel":41,"stem":62,"options":63,"answer":47,"analysis":37},974299,"消防增（稳）压设施按稳压工作形式可分为上置式和下置式两种。",[64,65],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":80,"analysis":37},974300,"下列湿式系统和干式系统的区分说法正确的是（ ）。",[70,72,74,76,78],{"key":20,"text":71,"correct":35},"湿式系统适用环境温度低于4℃或高于70℃的场所",{"key":24,"text":73,"correct":35},"干式系统适用环境温度不低于4℃或不高于70℃的场所",{"key":27,"text":75,"correct":22},"湿式系统喷头开启后立即出水",{"key":30,"text":77,"correct":35},"干式系统采用边墙型喷头",{"key":33,"text":79,"correct":22},"干式系统准工作状态时配水管道内充满用于启动系统的有压气体","CE",{"id":82,"libraryId":5,"type":83,"typeLabel":84,"stem":85,"options":86,"answer":27,"analysis":37},974301,1,"单选题","下列关于湿式系统和干式系统的说法正确的是（ ）。",[87,88,89,90],{"key":20,"text":71,"correct":35},{"key":24,"text":73,"correct":35},{"key":27,"text":75,"correct":22},{"key":30,"text":91,"correct":35},"干式式系统喷头开启后立即出水",{"id":93,"libraryId":5,"type":83,"typeLabel":84,"stem":94,"options":95,"answer":20,"analysis":37},974302,"机械加压送风方式的防烟系统是通过送风机送风，使需要加压送风的部位（如防烟楼梯间、消防前室等）压力大于周围环境的压力，下列关于压力大小的表达正确的是（ ）。",[96,98,100,102],{"key":20,"text":97,"correct":22},"防烟楼梯间压力＞前室压力＞走道压力＞房间压力",{"key":24,"text":99,"correct":35},"防烟楼梯间压力＞走道压力＞前室压力＞房间压力",{"key":27,"text":101,"correct":35},"防烟楼梯间压力＞前室压力＞房间压力＞走道压力",{"key":30,"text":103,"correct":35},"房间压力＞走道压力＞前室压力＞防烟楼梯间压力",{"id":105,"libraryId":5,"type":83,"typeLabel":84,"stem":106,"options":107,"answer":30,"analysis":37},974303,"火灾时排烟系统启动后，排烟风机入口处的（ ）在280℃关闭后直接联动排烟风机停止。",[108,110,112,114],{"key":20,"text":109,"correct":35},"排烟阀",{"key":24,"text":111,"correct":35},"防火阀",{"key":27,"text":113,"correct":35},"排烟窗",{"key":30,"text":115,"correct":22},"排烟防火阀",{"id":117,"libraryId":5,"type":83,"typeLabel":84,"stem":118,"options":119,"answer":30,"analysis":37},974304,"下列方式不符合自然通风要求的是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":35},"在防烟楼梯间的前室设置全敞开的阳台",{"key":24,"text":123,"correct":35},"在合用前室设置全敞开的凹廊",{"key":27,"text":125,"correct":35},"两个及以上不同朝向的符合面积要求的可开启外窗",{"key":30,"text":127,"correct":22},"设置可开启外窗",{"id":129,"libraryId":5,"type":83,"typeLabel":84,"stem":130,"options":131,"answer":27,"analysis":37},974305,"机械加压送风方式的防烟系统动作时，压力最大的是（ ）",[132,134,136,138],{"key":20,"text":133,"correct":35},"房间压力",{"key":24,"text":135,"correct":35},"走道压力",{"key":27,"text":137,"correct":22},"防烟楼梯间压力",{"key":30,"text":139,"correct":35},"前室压力",{"id":141,"libraryId":5,"type":83,"typeLabel":84,"stem":142,"options":143,"answer":24,"analysis":37},974306,"当防火分区内火灾确认后，应能在（ ）s内联动开启常闭加压送风口和加压送风机。",[144,146,148,150],{"key":20,"text":145,"correct":35},"10",{"key":24,"text":147,"correct":22},"15",{"key":27,"text":149,"correct":35},"20",{"key":30,"text":151,"correct":35},"5",{"id":153,"libraryId":5,"type":83,"typeLabel":84,"stem":154,"options":155,"answer":24,"analysis":37},974307,"下列属于排烟系统的联动触发信号的是（ ）",[156,158,160,162],{"key":20,"text":157,"correct":35},"同一防火分区内的两只独立的火灾探测器报警信号",{"key":24,"text":159,"correct":22},"同一防烟分区内的两只独立的火灾探测器报警信号",{"key":27,"text":161,"correct":35},"同一防火分区内一只感温火灾探测器与一只感烟火灾探测器的报警信号",{"key":30,"text":163,"correct":35},"同一防烟分区内一只火灾探测器与一只手动火灾报警按钮的报警信号",{"id":165,"libraryId":5,"type":83,"typeLabel":84,"stem":166,"options":167,"answer":24,"analysis":37},974308,"当火灾确认后，下列关于排烟系统动作错误的是（ ）。",[168,170,172,174],{"key":20,"text":169,"correct":35},"在15s内联动开启相应防烟分区的全部排烟阀、排烟口、排烟风机和补风设施",{"key":24,"text":171,"correct":22},"担负两个及以上防烟分区的排烟系统，应打开着火防烟分区及相邻防烟分区的排烟阀或排烟口",{"key":27,"text":173,"correct":35},"60s内挡烟垂壁应开启到位",{"key":30,"text":175,"correct":35},"与火灾自动报警系统联动的自动排烟窗应在60s内开启完毕",{"id":177,"libraryId":5,"type":83,"typeLabel":84,"stem":178,"options":179,"answer":24,"analysis":37},974309,"当温控释放装置的感温元件周围的温度达到（ ）时，温控释放装置动作，牵引开启卷门机的制动机构，松开刹车盘，卷帘依靠自重下降关闭。",[180,182,184,186],{"key":20,"text":181,"correct":35},"75±0.5℃",{"key":24,"text":183,"correct":22},"73±0.5℃",{"key":27,"text":185,"correct":35},"75±0.3℃",{"key":30,"text":187,"correct":35},"73±0.3℃",{"id":189,"libraryId":5,"type":83,"typeLabel":84,"stem":190,"options":191,"answer":20,"analysis":37},974310,"疏散通道防火卷帘门的自动控制：应由设置在防火卷帘两侧中任意一组（ ）的报警信号，作为系统的联动触发信号，联动控制防火卷帘的下降。",[192,194,196,198],{"key":20,"text":193,"correct":22},"感烟和感温火灾探测器",{"key":24,"text":195,"correct":35},"手动报警按钮",{"key":27,"text":197,"correct":35},"消火栓按钮",{"key":30,"text":199,"correct":35},"输入输出模块",{"id":201,"libraryId":5,"type":83,"typeLabel":84,"stem":202,"options":203,"answer":20,"analysis":37},974311,"下列不属于防火卷帘的组成部分的是（ ）。",[204,206,208,210],{"key":20,"text":205,"correct":22},"电动机",{"key":24,"text":207,"correct":35},"手动按钮盒",{"key":27,"text":209,"correct":35},"控制器",{"key":30,"text":211,"correct":35},"温控释放装置",{"id":213,"libraryId":5,"type":83,"typeLabel":84,"stem":214,"options":215,"answer":20,"analysis":37},974312,"关于疏散通道上设置的防火卷帘自动控制的说法不正确的是（ ）。",[216,218,220,222],{"key":20,"text":217,"correct":22},"任一只专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降至距楼板面1.8m处",{"key":24,"text":219,"correct":35},"防火分区内任两只独立的感烟火灾探测器的报警信号联动控制防火卷帘下降至距楼板面1.8m处",{"key":27,"text":221,"correct":35},"任一只专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降到楼板面",{"key":30,"text":223,"correct":35},"任一只专门用于联动防火卷帘的感烟火灾探测器联动控制防火卷帘下降至距楼板面1.8m处",{"id":225,"libraryId":5,"type":83,"typeLabel":84,"stem":226,"options":227,"answer":27,"analysis":37},974313,"对于非疏散通道上设置的防火卷帘，由防火卷帘所在防火分区内（ ）的报警信号作为防火卷帘下降的联动触发信号，联动控制防火卷帘直接下降到楼板面。",[228,230,232,234],{"key":20,"text":229,"correct":35},"任一只专门用于联动防火卷帘的感温火灾探测器",{"key":24,"text":231,"correct":35},"任一只专门用于联动防火卷帘的感烟火灾探测器",{"key":27,"text":233,"correct":22},"任两只独立火灾探测器",{"key":30,"text":235,"correct":35},"任两只独立的感烟火灾探测器",{"id":237,"libraryId":5,"type":83,"typeLabel":84,"stem":238,"options":239,"answer":30,"analysis":37},974314,"监控器与电动闭门器、电磁释放器、门磁开关间连接线断路、短路时，防火门监控器应在（ ）s内发出与报警信号有明显区别的声、光故障信号。",[240,241,243,245],{"key":20,"text":145,"correct":35},{"key":24,"text":242,"correct":35},"30",{"key":27,"text":244,"correct":35},"50",{"key":30,"text":246,"correct":22},"100",{"id":248,"libraryId":5,"type":83,"typeLabel":84,"stem":249,"options":250,"answer":27,"analysis":37},974315,"防火门监控器应能记录与其连接的防火门的状态信息，记录容量不应少于（ ）条。",[251,253,255,257],{"key":20,"text":252,"correct":35},"5000",{"key":24,"text":254,"correct":35},"8000",{"key":27,"text":256,"correct":22},"10000",{"key":30,"text":258,"correct":35},"15000",{"id":260,"libraryId":5,"type":83,"typeLabel":84,"stem":261,"options":262,"answer":27,"analysis":37},974316,"下列不属于常开式防火门关闭方法的是（ ）。",[263,265,267,269],{"key":20,"text":264,"correct":35},"防火门监控器手动关闭",{"key":24,"text":266,"correct":35},"常开式防火门现场手动关闭",{"key":27,"text":268,"correct":22},"消防控制室远程自动关闭",{"key":30,"text":270,"correct":35},"联动自动关闭",{"id":272,"libraryId":5,"type":83,"typeLabel":84,"stem":273,"options":274,"answer":24,"analysis":37},974317,"下列关于防火门监控器的备用电源电池容量在监控器处于通电工作状态时应正常可靠工作（ ）。",[275,277,279,281],{"key":20,"text":276,"correct":35},"1.0h",{"key":24,"text":278,"correct":22},"3.0h",{"key":27,"text":280,"correct":35},"8.0h",{"key":30,"text":282,"correct":35},"24.0h",{"id":284,"libraryId":5,"type":83,"typeLabel":84,"stem":285,"options":286,"answer":20,"analysis":37},974318,"下列关于消防应急灯具的分类说法正确的是：（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":22},"按用途分为消防应急标志灯具、消防应急照明灯具、消防应急照明标志复合灯具",{"key":24,"text":290,"correct":35},"按工作方式分为自带电源型消防应急灯具、集中电源型消防应急灯具、子母型消防应急灯具",{"key":27,"text":292,"correct":35},"按应急供电方式分为集中控制型消防应急灯具、非集中控制型消防应急灯具",{"key":30,"text":294,"correct":35},"按应急控制方式分为持续型消防应急灯具、非持续型消防应急灯具",{"id":296,"libraryId":5,"type":83,"typeLabel":84,"stem":297,"options":298,"answer":20,"analysis":37},974319,"下列关于应急照明和疏散指示系统的分类说法不正确的是（ ）。",[299,301,303,305],{"key":20,"text":300,"correct":22},"消防应急照明和疏散指示系统按消防应急灯具控制方式的不同，可分为集中电源集中控制型系统、集中电源非集中控制型系统、自带电源集中控制型系统和自带电源非集中控制型系统",{"key":24,"text":302,"correct":35},"根据消防应急灯具蓄电池电源供电方式的不同，集中控制型系统分为灯具采用集中电源供电方式的集中控制型系统和灯具采用蓄电池供电方式的集中控制型系统",{"key":27,"text":304,"correct":35},"根据消防应急灯具蓄电池电源供电方式的不同，非集中控制型系统分为灯具采用集中电源供电方式的非集中控制型系统和灯具釆用蓄电池供电方式的非集中控制型系统",{"key":30,"text":306,"correct":35},"消防应急照明和疏散指示系统按系统形式可分为集中电源集中控制型系统、集中电源非集中控制型系统、自带电源集中控制型系统和自带电源非集中控制型系统",{"id":308,"libraryId":5,"type":83,"typeLabel":84,"stem":309,"options":310,"answer":27,"analysis":37},974320,"任一台应急照明控制器直接控制灯具的总数量不应大于（ ）只。",[311,313,315,317],{"key":20,"text":312,"correct":35},"1600",{"key":24,"text":314,"correct":35},"2000",{"key":27,"text":316,"correct":22},"3200",{"key":30,"text":318,"correct":35},"3600",{"id":320,"libraryId":5,"type":83,"typeLabel":84,"stem":321,"options":322,"answer":24,"analysis":37},974321,"应急照明控制器控制器的自带蓄电池电源应至少使控制器在主电源中断后工作（ ）。",[323,324,325,326],{"key":20,"text":276,"correct":35},{"key":24,"text":278,"correct":22},{"key":27,"text":280,"correct":35},{"key":30,"text":282,"correct":35},{"id":328,"libraryId":5,"type":83,"typeLabel":84,"stem":329,"options":330,"answer":24,"analysis":37},974322,"下列关于应急照明控制器设置在消防控制室地面上时，下列说法不符合规定的是（ ）。",[331,333,335,337],{"key":20,"text":332,"correct":35},"设备面板前的操作距离，单列布置时不应小于1.5m；双列布置时不应小于2m",{"key":24,"text":334,"correct":22},"在值班人员经常工作的一面，设备面板至墙的距离不应小于4m",{"key":27,"text":336,"correct":35},"设备面板后的维修距离不宜小于1m",{"key":30,"text":338,"correct":35},"设备面盘的排列长度大于4m时，其两端应设置宽度不小于1m的通道",{"id":340,"libraryId":5,"type":83,"typeLabel":84,"stem":341,"options":342,"answer":30,"analysis":37},974323,"发生火灾时，由消防联动控制器联动控制应急照明配电箱的工作状态，进而控制各路消防应急灯具的工作状态是指（ ）。",[343,345,347,349],{"key":20,"text":344,"correct":35},"集中电源集中控制型系统",{"key":24,"text":346,"correct":35},"集中电源非集中控制型系统",{"key":27,"text":348,"correct":35},"自带电源集中控制型系统",{"key":30,"text":350,"correct":22},"自带电源非集中控制型系统",{"id":352,"libraryId":5,"type":83,"typeLabel":84,"stem":353,"options":354,"answer":30,"analysis":37},974324,"下列不属于火灾时普通电梯迫降要求的是（ ）。",[355,357,359,361],{"key":20,"text":356,"correct":35},"使电梯返回到指定层（一般为首层）",{"key":24,"text":358,"correct":35},"退出正常服务",{"key":27,"text":360,"correct":35},"电梯处于“开门停用”的状态",{"key":30,"text":362,"correct":22},"电梯处于“开门待用”的状态",{"id":364,"libraryId":5,"type":83,"typeLabel":84,"stem":365,"options":366,"answer":27,"analysis":37},974325,"消防电梯紧急迫降按钮应设置在距消防电梯水平距离（ ）m以内的墙面上。",[367,369,371,373],{"key":20,"text":368,"correct":35},"1",{"key":24,"text":370,"correct":35},"1.5",{"key":27,"text":372,"correct":22},"2",{"key":30,"text":374,"correct":35},"2.5",{"id":376,"libraryId":5,"type":83,"typeLabel":84,"stem":377,"options":378,"answer":30,"analysis":37},974326,"消防电梯紧急迫降按钮应设置在距地面高度（ ）m的墙面上。",[379,381,383,385],{"key":20,"text":380,"correct":35},"1.0-1.3",{"key":24,"text":382,"correct":35},"1.3-1.5",{"key":27,"text":384,"correct":35},"1.5-1.8",{"key":30,"text":386,"correct":22},"1.8-2.1",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":401,"analysis":37},974327,"下列关于主机录制、播放疏散指令操作方法正确的有（ ）。",[391,393,395,397,399],{"key":20,"text":392,"correct":22},"准备一台消防应急广播主机和MP3播放器",{"key":24,"text":394,"correct":22},"开机，按住“录音”键直至数码管开始闪动，松开按键",{"key":27,"text":396,"correct":35},"准备好疏散音源文件放入U盘中，插入MP3播放器，将广播主机设置在暂停状态",{"key":30,"text":398,"correct":22},"数码管闪动后等5s左右，再次短按“录音”键，录音指示灯应点亮",{"key":33,"text":400,"correct":22},"录音指示灯点亮后，开始播放MP3播放器上的疏散音源文件，播放完一个周期后，按停止键，回到待机状态","ABDE",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":416,"analysis":37},974328,"下列符合排烟风机、补风机的控制方式要求的有（ ）。",[406,408,410,412,414],{"key":20,"text":407,"correct":22},"系统中任一排烟阀或排烟口开启时，排烟风机、补风机自动启动",{"key":24,"text":409,"correct":22},"火灾自动报警系统自动启动",{"key":27,"text":411,"correct":22},"消防控制室手动启动",{"key":30,"text":413,"correct":35},"排烟防火阀在280℃时应自行关闭，但不能连锁关闭排烟风机和补风机",{"key":33,"text":415,"correct":22},"现场手动启动","ABCE",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":431,"analysis":37},974329,"当防火分区内火灾确认后，建筑内的防烟系统应能在15s内联动开启常闭加压送风口和加压送风机，下列说法正确的是（ ）。",[421,423,425,427,429],{"key":20,"text":422,"correct":22},"应开启该防火分区楼梯间的全部加压送风机",{"key":24,"text":424,"correct":22},"应开启该防火分区内着火层及其相邻上下层前室及合用前室的常闭送风口",{"key":27,"text":426,"correct":35},"应开启该防火分区内着火层相邻上一层前室及合用前室的常闭送风口",{"key":30,"text":428,"correct":35},"应开启该防火分区内着火层相邻下一层前室及合用前室的常闭送风口",{"key":33,"text":430,"correct":22},"同时开启加压送风机","ABE",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":442,"analysis":37},974330,"下列方式符合自然通风要求的是（ ）。",[436,437,438,439,440],{"key":20,"text":121,"correct":22},{"key":24,"text":123,"correct":22},{"key":27,"text":125,"correct":22},{"key":30,"text":127,"correct":35},{"key":33,"text":441,"correct":35},"防烟楼梯间内设置全敞开的阳台","ABC",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":457,"analysis":37},974331,"当火灾确认后，下列关于排烟系统的动作正确的有（ ）。",[447,449,451,453,455],{"key":20,"text":448,"correct":35},"火灾自动报警系统应在30s内联动开启相应防烟分区的全部排烟阀、排烟口、排烟风机和补风设施",{"key":24,"text":450,"correct":22},"担负两个及以上防烟分区的排烟系统，应仅打开着火防烟分区的排烟阀或排烟口，其他防烟分区的排烟阀或排烟口应呈关闭状态",{"key":27,"text":452,"correct":22},"与火灾自动报警系统联动的自动排烟窗应在60s内或低于烟气充满储烟仓的时间内开启完毕",{"key":30,"text":454,"correct":35},"火灾自动报警系统应在30s内联动相应防烟分区的全部活动挡烟垂壁",{"key":33,"text":456,"correct":22},"火灾自动报警系统在30s内自动关闭与排烟无关的通风、空调系统","BCE",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":36,"analysis":37},974332,"下列方式可以控制加压送风机启动的有（ ）。",[462,463,465,466,468],{"key":20,"text":415,"correct":22},{"key":24,"text":464,"correct":22},"通过火灾自动报警系统自动启动",{"key":27,"text":411,"correct":22},{"key":30,"text":467,"correct":22},"系统中任一常闭加压送风口开启时，加压风机自动启动",{"key":33,"text":469,"correct":35},"系统中任一常闭防火阀开启时，加压风机自动启动",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":481,"analysis":37},974333,"下列方式可以控制排烟风机启动的有（ ）。",[474,475,476,477,479],{"key":20,"text":415,"correct":22},{"key":24,"text":464,"correct":22},{"key":27,"text":411,"correct":22},{"key":30,"text":478,"correct":22},"系统中任一排烟阀或排烟口开启时，排烟风机自动启动",{"key":33,"text":480,"correct":22},"排烟防火阀在280℃时自行关闭，连锁关闭排烟风机","ABCDE",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":442,"analysis":37},974334,"下列方式可以控制挡烟垂壁动作的有（ ）。",[486,488,490,492,494],{"key":20,"text":487,"correct":22},"现场手动操作",{"key":24,"text":489,"correct":22},"挡烟垂壁接收到消防控制中心的控制信号后下降至挡烟工作位置",{"key":27,"text":491,"correct":22},"当配接的烟感探测器报警后，挡烟垂壁自动下降至挡烟工作位置",{"key":30,"text":493,"correct":35},"系统断电时，挡烟垂壁保持在准工作状态位置",{"key":33,"text":495,"correct":35},"消防控制室手动操作",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":80,"analysis":37},974335,"下列不属于防火卷帘按材质分类的是（ ）。",[500,502,504,506,508],{"key":20,"text":501,"correct":35},"钢质防火卷帘",{"key":24,"text":503,"correct":35},"无机纤维复合防火卷帘",{"key":27,"text":505,"correct":22},"单帘面防火卷帘",{"key":30,"text":507,"correct":35},"特级防火卷帘",{"key":33,"text":509,"correct":22},"双帘面防火卷帘",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":519,"analysis":37},974336,"下列不属于防火卷帘按帘面数量分类的是（ ）。",[514,515,516,517,518],{"key":20,"text":501,"correct":22},{"key":24,"text":503,"correct":22},{"key":27,"text":505,"correct":35},{"key":30,"text":507,"correct":22},{"key":33,"text":509,"correct":35},"ABD",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":442,"analysis":37},974337,"下列属于防火卷帘按启闭方式分类的是（ ）。",[524,526,528,530,532],{"key":20,"text":525,"correct":22},"垂直卷",{"key":24,"text":527,"correct":22},"侧向卷",{"key":27,"text":529,"correct":22},"水平卷",{"key":30,"text":531,"correct":35},"推拉卷",{"key":33,"text":533,"correct":35},"卷筒卷",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":481,"analysis":37},974338,"下列属于防火卷帘主要组成部分的是（ ）。",[538,540,542,543,544],{"key":20,"text":539,"correct":22},"帘面",{"key":24,"text":541,"correct":22},"导轨",{"key":27,"text":209,"correct":22},{"key":30,"text":211,"correct":22},{"key":33,"text":207,"correct":22},{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":481,"analysis":37},974339,"下列属于防火卷帘主要控制方式的有（ ）。",[549,551,553,555,557],{"key":20,"text":550,"correct":22},"现场手动电控",{"key":24,"text":552,"correct":22},"自动控制",{"key":27,"text":554,"correct":22},"温控释放控制",{"key":30,"text":556,"correct":22},"现场机械控制",{"key":33,"text":558,"correct":22},"限位控制",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":570,"analysis":37},974340,"下列关于疏散通道上设置的防火卷帘自动控制的说法正确的是（ ）。",[563,564,566,567,568],{"key":20,"text":217,"correct":35},{"key":24,"text":565,"correct":35},"任一只专门用于联动防火卷帘的感烟火灾探测器联动控制防火卷帘下降到楼板面",{"key":27,"text":221,"correct":22},{"key":30,"text":223,"correct":22},{"key":33,"text":569,"correct":35},"两只专门用于联动防火卷帘的感烟火灾探测器联动控制防火卷帘下降到楼板面","CD",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":481,"analysis":37},974341,"当防火门监控器出现故障时，应在100s内发出与报警信号有明显区别的声、光故障信号，下列属于防火门监控器会出现的故障的有（ ）。",[575,577,579,581,583],{"key":20,"text":576,"correct":22},"监控器的主电源断电",{"key":24,"text":578,"correct":22},"监控器与电动闭门器、电磁释放器、门磁开关间连接线断路、短路",{"key":27,"text":580,"correct":22},"备用电源发生故障",{"key":30,"text":582,"correct":22},"门磁开关供电电源故障",{"key":33,"text":584,"correct":22},"备用电源与充电器之间的连接线断路、短路",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":599,"analysis":37},974342,"下列关于防火门监控器备用电源的设置要求说法正确的是（ ）。",[589,591,593,595,597],{"key":20,"text":590,"correct":22},"备用电源应采用密封、免维护充电电池。",{"key":24,"text":592,"correct":35},"监控器处于通电工作状态下，电池容量能可靠工作2h",{"key":27,"text":594,"correct":22},"提供防火门开启以及关闭3h所需的电源",{"key":30,"text":596,"correct":22},"有防止电池过充电、过放电的功能",{"key":33,"text":598,"correct":35},"在不超过生产厂规定的电池极限放电情况下，应能在12h内完成对电池的充电","ACD",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":442,"analysis":37},974343,"下列需要采用防火门监控器上红色指示灯用来指的是（ ）。",[604,606,608,610,612],{"key":20,"text":605,"correct":22},"启动信号",{"key":24,"text":607,"correct":22},"电动闭门器的动作信号",{"key":27,"text":609,"correct":22},"电磁释放器的动作信号",{"key":30,"text":611,"correct":35},"故障、自检状态",{"key":33,"text":613,"correct":35},"电磁释放器的反馈信号",{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":628,"analysis":37},974344,"下列属于电梯迫降方法的有（ ）。",[618,620,622,624,626],{"key":20,"text":619,"correct":35},"手动迫降",{"key":24,"text":621,"correct":22},"紧急迫降按钮迫降",{"key":27,"text":623,"correct":22},"消防控制室远程控制迫降",{"key":30,"text":625,"correct":22},"自动联动控制迫降",{"key":33,"text":627,"correct":35},"温控释放控制迫降","BCD",[630,633,636,639,642,645],{"id":83,"name":631,"category":7,"favorite":632},"领导干部任职前廉政法规知识测试题",92,{"id":634,"name":635,"category":7,"favorite":83},595,"建筑结构与设备",{"id":637,"name":638,"category":7,"favorite":83},715,"招标采购专业知识与法律法规",{"id":640,"name":641,"category":7,"favorite":83},848,"市政方向-通用基础",{"id":643,"name":644,"category":7,"favorite":8},534,"BIM工程师",{"id":646,"name":644,"category":7,"favorite":8},535]