[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-704-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":487},{"id":5,"name":6,"category":7,"favorite":8},704,"中级技能","建筑工程",0,27,50,2486,[13,38,48,54,60,66,72,78,84,90,96,102,108,114,120,126,132,146,158,170,176,182,194,206,218,230,245,256,271,285,300,306,312,318,324,330,336,342,348,360,368,380,392,404,416,428,437,449,460,474],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},974245,2,"多选题","符合下列条件之一的场所，不宜选择线型光束感烟火灾探测器（ ）。",[19,23,26,29,32],{"key":20,"text":21,"correct":22},"A","有大量粉尘、水雾滞留",true,{"key":24,"text":25,"correct":22},"B","可能产生蒸气和油雾",{"key":27,"text":28,"correct":22},"C","在正常情况下有烟滞留",{"key":30,"text":31,"correct":22},"D","固定探测器的建筑结构由于振动等原因会产生较大位移的场所",{"key":33,"text":34,"correct":35},"E","各种皮带输送装置",false,"ABCD","",{"id":39,"libraryId":5,"type":40,"typeLabel":41,"stem":42,"options":43,"answer":45,"analysis":37},974246,3,"判断题","当集中火灾报警控制器、消防联动控制器收到火灾报警信息时，不但会在屏幕上显示火灾发生的位置信息、点亮火警指示灯、发出火警报警音，还会按照预设的逻辑关系联动启动声光报警、消防广播及所控制的现场消防设备。",[44,46],{"key":20,"text":45,"correct":22},"正确",{"key":24,"text":47,"correct":35},"错误",{"id":49,"libraryId":5,"type":40,"typeLabel":41,"stem":50,"options":51,"answer":47,"analysis":37},974247,"在手动状态下，通过按下手动火灾报警按钮或触发烟感报警产生火警信号，将控制器切换为手动状态并指出对应的特征变化（显示屏、指示灯特征）。",[52,53],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":55,"libraryId":5,"type":40,"typeLabel":41,"stem":56,"options":57,"answer":45,"analysis":37},974248,"无论是在位图显示还是列表显示下，点击相应的节点设备会显示设备的详细信息",[58,59],{"key":20,"text":45,"correct":22},{"key":24,"text":47,"correct":35},{"id":61,"libraryId":5,"type":40,"typeLabel":41,"stem":62,"options":63,"answer":47,"analysis":37},974249,"进入“分类查看”页面，根据现场消防设备类型、回路号、地址号进行筛选。",[64,65],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":67,"libraryId":5,"type":40,"typeLabel":41,"stem":68,"options":69,"answer":45,"analysis":37},974250,"点击切换键，回路配接设备位图显示切换为列表显示，列表显示可以方便地查看每一个地址的详细信息。",[70,71],{"key":20,"text":45,"correct":22},{"key":24,"text":47,"correct":35},{"id":73,"libraryId":5,"type":40,"typeLabel":41,"stem":74,"options":75,"answer":47,"analysis":37},974251,"在每种记录列表中，点击功能按键两次可以打印当前显示的20条记录。",[76,77],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":79,"libraryId":5,"type":40,"typeLabel":41,"stem":80,"options":81,"answer":47,"analysis":37},974252,"如果“启动”指示灯处于常亮状态，表示多线控制盘手动控制单元已发出启动指令，等待反馈。",[82,83],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":85,"libraryId":5,"type":40,"typeLabel":41,"stem":86,"options":87,"answer":45,"analysis":37},974253,"线型火灾探测器主要分为线型感烟火灾探测器和线型感温火灾探测器等。",[88,89],{"key":20,"text":45,"correct":22},{"key":24,"text":47,"correct":35},{"id":91,"libraryId":5,"type":40,"typeLabel":41,"stem":92,"options":93,"answer":47,"analysis":37},974254,"线型感温火灾探测器是指对某一连续线路周围气温和\u002F或气温变化响应的线型火灾探测器。",[94,95],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":97,"libraryId":5,"type":40,"typeLabel":41,"stem":98,"options":99,"answer":47,"analysis":37},974255,"线型光束感烟火灾探测器是指应用光束被烟雾粒子吸收而加强的原理探测火灾的线型感烟探测器。",[100,101],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":103,"libraryId":5,"type":40,"typeLabel":41,"stem":104,"options":105,"answer":47,"analysis":37},974256,"线型感温火灾探测器按定位方式可分为探测型和探测报警型。",[106,107],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":109,"libraryId":5,"type":40,"typeLabel":41,"stem":110,"options":111,"answer":47,"analysis":37},974257,"线型感温火灾探测器按敏感部件形式可分为缆式、空气管式、分布式光纤、光纤光栅和不可恢复式。",[112,113],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":115,"libraryId":5,"type":40,"typeLabel":41,"stem":116,"options":117,"answer":47,"analysis":37},974258,"无遮挡的大空间或有特殊要求的房间，宜选择线型光纤感温火灾探测器。",[118,119],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":121,"libraryId":5,"type":40,"typeLabel":41,"stem":122,"options":123,"answer":47,"analysis":37},974259,"采用主电源为220V、50Hz交流电源供电的火灾显示盘主电源应能保证火灾显示盘在火灾报警状态下连续工作8h，且应有过流保护措施。",[124,125],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":127,"libraryId":5,"type":40,"typeLabel":41,"stem":128,"options":129,"answer":47,"analysis":37},974260,"火灾显示盘面板上一般只有消音键和复位键，可以现场对火灾显示盘进行消音和复位。",[130,131],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":133,"libraryId":5,"type":134,"typeLabel":135,"stem":136,"options":137,"answer":30,"analysis":37},974261,1,"单选题","在火灾报警控制器上，按下“复位”键，对操作信息显示描述不正确的是（ ）。",[138,140,142,144],{"key":20,"text":139,"correct":35},"清除当前的所有火警、故障和反馈等显示",{"key":24,"text":141,"correct":35},"复位所有总线制被控设备和手动消防启动盘、多线制消防联动控制盘上的状态指示灯",{"key":27,"text":143,"correct":35},"清除正处于请求和延时请求启动的命令；清除消音状态",{"key":30,"text":145,"correct":22},"清除屏蔽信息",{"id":147,"libraryId":5,"type":134,"typeLabel":135,"stem":148,"options":149,"answer":20,"analysis":37},974262,"在火灾报警控制器上，（ ）是手动消防启动盘对联动设备进行启动和停动的操作。",[150,152,154,156],{"key":20,"text":151,"correct":22},"手动允许",{"key":24,"text":153,"correct":35},"全部自动",{"key":27,"text":155,"correct":35},"部分自动",{"key":30,"text":157,"correct":35},"喷洒允许",{"id":159,"libraryId":5,"type":134,"typeLabel":135,"stem":160,"options":161,"answer":27,"analysis":37},974263,"在火灾报警控制器上，设置手\u002F自动模式，对操作信息显示描述不正确的一项是（ ）。",[162,164,166,168],{"key":20,"text":163,"correct":35},"手动允许时，面板上的“手动允许”灯点亮，只有控制器处于“手动允许”的状态下，才能发出手动启动命令",{"key":24,"text":165,"correct":35},"自动方式是指满足联动条件后，系统自动进行的联动操作",{"key":27,"text":167,"correct":22},"只有全部自动允许时，面板上的“自动允许”灯才亮",{"key":30,"text":169,"correct":35},"控制器只有处于“自动允许”的状态下，才能发出自动联动启动命令",{"id":171,"libraryId":5,"type":40,"typeLabel":41,"stem":172,"options":173,"answer":45,"analysis":37},974264,"历史记录包括火警记录、设备故障记录、请求记录、启动记录、反馈记录、操作记录、监管记录、气灭记录和其他故障记录，每种数量最多为10000条，存满后新事件产生时覆盖一个最远的事件。",[174,175],{"key":20,"text":45,"correct":22},{"key":24,"text":47,"correct":35},{"id":177,"libraryId":5,"type":40,"typeLabel":41,"stem":178,"options":179,"answer":47,"analysis":37},974265,"当模拟所辖区域内火灾报警或故障报警时，火灾显示盘应能接收信号，并发出火灾报警或故障报警声信号，按下火灾显示盘消音键，可消除当前报警声，消音指示灯应熄灭。",[180,181],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":183,"libraryId":5,"type":134,"typeLabel":135,"stem":184,"options":185,"answer":24,"analysis":37},974266,"在（ ）状态下，工作指示灯处于红灯运行状态，不能通过总线控制盘手动启动火灾声光警报器、消防广播、加压送风口、加压送风机排烟阀、排烟机，释放防火卷帘、关闭常开型防火门、切断非消防电源和迫降电梯等。",[186,188,190,192],{"key":20,"text":187,"correct":35},"“允许”状态",{"key":24,"text":189,"correct":22},"“禁止”状态",{"key":27,"text":191,"correct":35},"\"启动”状态",{"key":30,"text":193,"correct":35},"“反馈”状态",{"id":195,"libraryId":5,"type":134,"typeLabel":135,"stem":196,"options":197,"answer":24,"analysis":37},974267,"每个操作按钮（ ），分别用于提示按键状态、显示设备运行状态。",[198,200,202,204],{"key":20,"text":199,"correct":35},"分别对应一个启动指示灯和一个故障指示灯",{"key":24,"text":201,"correct":22},"分别对应一个启动指示灯和一个反馈指示灯",{"key":27,"text":203,"correct":35},"分别对应一个故障指示灯和一个反馈指示灯",{"key":30,"text":205,"correct":35},"分别对应一个启动指示灯和一个禁止指示灯",{"id":207,"libraryId":5,"type":134,"typeLabel":135,"stem":208,"options":209,"answer":20,"analysis":37},974268,"当火灾发生时，随着灭火设备开启用水，由于稳压泵流量较小，气压罐内的水量持续减少，罐内压力不断下降，当压力持续（ ）低于设定的消防泵组启动压力P2时，消防泵组自动启动向消防给水管网供水。",[210,212,214,216],{"key":20,"text":211,"correct":22},"10S",{"key":24,"text":213,"correct":35},"20S",{"key":27,"text":215,"correct":35},"30S",{"key":30,"text":217,"correct":35},"60S",{"id":219,"libraryId":5,"type":134,"typeLabel":135,"stem":220,"options":221,"answer":27,"analysis":37},974269,"消防泵组电气控制柜还应设置（ ）功能，并应保证在控制柜内的控制线路发生故障时由有管理权限的人员在紧急时启动消防水泵。",[222,224,226,228],{"key":20,"text":223,"correct":35},"自动启泵",{"key":24,"text":225,"correct":35},"手动启泵",{"key":27,"text":227,"correct":22},"机械应急启泵",{"key":30,"text":229,"correct":35},"连锁启泵",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":244,"analysis":37},974270,"下列不属于湿式自动喷水灭火系统主要组成的有（ ）。",[234,236,238,240,242],{"key":20,"text":235,"correct":35},"闭式喷头",{"key":24,"text":237,"correct":22},"开式喷头",{"key":27,"text":239,"correct":35},"水流指示器",{"key":30,"text":241,"correct":35},"末端试水装置",{"key":33,"text":243,"correct":22},"充气和气压维持装置","BE",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":255,"analysis":37},974271,"下列属于干式自动喷水灭火系统主要组成的有（ ）。",[249,250,251,253,254],{"key":20,"text":235,"correct":22},{"key":24,"text":237,"correct":35},{"key":27,"text":252,"correct":22},"干式报警阀组",{"key":30,"text":241,"correct":22},{"key":33,"text":243,"correct":22},"ACDE",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":270,"analysis":37},974272,"下列关于干式自动喷水灭火系统工作原理的描述正确的有（ ）。",[260,262,264,266,268],{"key":20,"text":261,"correct":22},"在准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持水源侧管道内充水的压力",{"key":24,"text":263,"correct":22},"发生火灾时，闭式喷头受热开启",{"key":27,"text":265,"correct":35},"管道中的有压水从喷头喷出，干式报警阀系统侧压力下降",{"key":30,"text":267,"correct":22},"消防水箱出水管上的流量开关、消防水泵出水干管上的压力开关或报警阀组的压力关动作并输出启动消防水泵信号，完成系统的启动",{"key":33,"text":269,"correct":22},"系统启动后，由消防水泵向开放的喷头供水，开放的喷头按不低于设计规定的喷水强度均匀喷洒，实施灭火","ABDE",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":284,"analysis":37},974273,"下列关于湿式自动喷水灭火系统工作原理的描述正确的有（ ）。",[275,277,279,281,283],{"key":20,"text":276,"correct":35},"在准工作状态时，由消防水泵维持管道内充水的压力",{"key":24,"text":278,"correct":22},"发生火灾时，火源周围环境温度上升，闭式喷头受热后开启喷水",{"key":27,"text":280,"correct":35},"湿式报警阀系统侧压力下降，造成湿式报警阀系统侧压力大于水源侧压力，湿式报警阀被自动打开",{"key":30,"text":282,"correct":22},"消防水箱出水管上的流量开关、消防水泵出水干管上的压力开关或报警阀组的压力开关动作并输出启动消防水泵信号，完成系统的启动",{"key":33,"text":269,"correct":22},"BDE",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":299,"analysis":37},974274,"下列属于消防泵组电气控制柜应具有的功能是（ ）。",[289,291,293,295,297],{"key":20,"text":290,"correct":22},"过载保护",{"key":24,"text":292,"correct":22},"短路保护",{"key":27,"text":294,"correct":22},"过压保护",{"key":30,"text":296,"correct":22},"缺相保护",{"key":33,"text":298,"correct":22},"过热保护","ABCDE",{"id":301,"libraryId":5,"type":40,"typeLabel":41,"stem":302,"options":303,"answer":47,"analysis":37},974275,"湿式系统在准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持水源侧管道内充水的压力，系统侧管道内充满有压气体（通常釆用压缩空气），报警阀处于关闭状态。",[304,305],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":307,"libraryId":5,"type":40,"typeLabel":41,"stem":308,"options":309,"answer":47,"analysis":37},974276,"发生火灾时，闭式喷头受热开启，管道中的有压气体从喷头喷出，湿式报警阀系统侧压力下降，造成湿式报警阀水源侧压力大于系统侧压力，湿式报警阀被自动打开，压力水进入供水管道，将剩余压缩空气从系统立管顶端或横干管最高处的排气阀或已打开的喷头处喷出，然后喷水灭火",[310,311],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":313,"libraryId":5,"type":40,"typeLabel":41,"stem":314,"options":315,"answer":47,"analysis":37},974277,"干式系统在准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持管道内充水的压力。",[316,317],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":319,"libraryId":5,"type":40,"typeLabel":41,"stem":320,"options":321,"answer":47,"analysis":37},974278,"干式系统发生火灾时，火源周围环境温度上升，闭式喷头受热后开启喷水，水流指示器动作并反馈信号至消防控制中心报警控制器，指示起火区域。",[322,323],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":325,"libraryId":5,"type":40,"typeLabel":41,"stem":326,"options":327,"answer":47,"analysis":37},974279,"自动喷水灭火系统电气控制柜主要具备启\u002F停泵、主\u002F备泵切换、手\u002F自动转换功能。",[328,329],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":331,"libraryId":5,"type":40,"typeLabel":41,"stem":332,"options":333,"answer":47,"analysis":37},974280,"消防泵组电气控制柜在自动状态下，可自动或远程手动启动和停止水泵。",[334,335],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":337,"libraryId":5,"type":40,"typeLabel":41,"stem":338,"options":339,"answer":47,"analysis":37},974281,"消防泵组电气控制柜应具有过载保护、短路保护、过压保护、欠压保护功能。",[340,341],{"key":20,"text":45,"correct":35},{"key":24,"text":47,"correct":22},{"id":343,"libraryId":5,"type":40,"typeLabel":41,"stem":344,"options":345,"answer":45,"analysis":37},974282,"控制柜应具有机械应急启动功能。在控制柜内的控制线路发生故障时可由具有管理权限的人员在紧急时启动消防水泵。",[346,347],{"key":20,"text":45,"correct":22},{"key":24,"text":47,"correct":35},{"id":349,"libraryId":5,"type":134,"typeLabel":135,"stem":350,"options":351,"answer":27,"analysis":37},974283,"下列不属于湿式系统在准工作状态时，维持管道内充水压力的稳压设置是（ ）。",[352,354,356,358],{"key":20,"text":353,"correct":35},"消防水箱",{"key":24,"text":355,"correct":35},"稳压泵",{"key":27,"text":357,"correct":22},"消防水泵",{"key":30,"text":359,"correct":35},"气压给水设备",{"id":361,"libraryId":5,"type":134,"typeLabel":135,"stem":362,"options":363,"answer":27,"analysis":37},974284,"下列不属于干式系统在准工作状态时，维持水源侧管道内充水压力的稳压设施是（ ）。",[364,365,366,367],{"key":20,"text":353,"correct":35},{"key":24,"text":355,"correct":35},{"key":27,"text":357,"correct":22},{"key":30,"text":359,"correct":35},{"id":369,"libraryId":5,"type":134,"typeLabel":135,"stem":370,"options":371,"answer":20,"analysis":37},974285,"由控制柜按照预先设定逻辑，定期自动控制消防水泵变频运行，并发出各类巡检信号。下列关于消防泵组电气控制柜巡检周期及消防水泵低速转动的时间说法正确的是（ ）。",[372,374,376,378],{"key":20,"text":373,"correct":22},"巡检周期不宜大于7d，每台消防水泵低速转动的时间不应少于2min",{"key":24,"text":375,"correct":35},"巡检周期不宜小于7d，每台消防水泵低速转动的时间不应少于2min",{"key":27,"text":377,"correct":35},"巡检周期不宜大于7d，每台消防水泵低速转动的时间不应大于2min",{"key":30,"text":379,"correct":35},"巡检周期不宜小于7d，每台消防水泵低速转动的时间不应大于2min",{"id":381,"libraryId":5,"type":134,"typeLabel":135,"stem":382,"options":383,"answer":24,"analysis":37},974286,"下列可以进行远程手动启\u002F停消防水泵的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":35},"高位消防水箱出水管流量开关",{"key":24,"text":387,"correct":22},"消防控制室多线控制盘",{"key":27,"text":389,"correct":35},"报阀组压力开关",{"key":30,"text":391,"correct":35},"消防水泵出水干管压力开关",{"id":393,"libraryId":5,"type":134,"typeLabel":135,"stem":394,"options":395,"answer":24,"analysis":37},974287,"消防水泵启动方式中下列属于手动启动控制的是（ ）",[396,398,400,402],{"key":20,"text":397,"correct":35},"消防控制室总线联动启动",{"key":24,"text":399,"correct":22},"消防控制室多线控制盘操作按钮启动",{"key":27,"text":401,"correct":35},"高位消防水箱出水管流量开关启动",{"key":30,"text":403,"correct":35},"报警阀组压力开关启动",{"id":405,"libraryId":5,"type":134,"typeLabel":135,"stem":406,"options":407,"answer":27,"analysis":37},974288,"机械应急启动时，应确保消防水泵在报警（ ）min内正常工作。",[408,410,412,414],{"key":20,"text":409,"correct":35},"1.0",{"key":24,"text":411,"correct":35},"3.0",{"key":27,"text":413,"correct":22},"5.0",{"key":30,"text":415,"correct":35},"10.0",{"id":417,"libraryId":5,"type":134,"typeLabel":135,"stem":418,"options":419,"answer":30,"analysis":37},974289,"当主泵发生故障时，备用泵自动延时投入。水泵启动时间不应大于（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":35},"1.0min",{"key":24,"text":423,"correct":35},"3.0min",{"key":27,"text":425,"correct":35},"5.0min",{"key":30,"text":427,"correct":22},"2.0min",{"id":429,"libraryId":5,"type":134,"typeLabel":135,"stem":430,"options":431,"answer":24,"analysis":37},974290,"下列不属于消防泵组电气控制柜功能的是（ ）。",[432,433,435,436],{"key":20,"text":290,"correct":35},{"key":24,"text":434,"correct":22},"断路保护",{"key":27,"text":294,"correct":35},{"key":30,"text":296,"correct":35},{"id":438,"libraryId":5,"type":134,"typeLabel":135,"stem":439,"options":440,"answer":20,"analysis":37},974291,"为确保消防水泵的可靠控制，适应消防水泵启动灭火、灾后控制以及维护保养的需求，消防水泵应能（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":22},"手动启停和自动启动",{"key":24,"text":444,"correct":35},"手动启停或自动启动",{"key":27,"text":446,"correct":35},"手动启动和自动启动",{"key":30,"text":448,"correct":35},"手动启停和自动启停",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":459,"analysis":37},974292,"消防泵组电气控制柜设置有手动、自动转换开关，当开关处于自动位，下列可自动启动消防水泵的有（ ）。",[453,454,455,456,457],{"key":20,"text":385,"correct":22},{"key":24,"text":387,"correct":35},{"key":27,"text":389,"correct":22},{"key":30,"text":391,"correct":22},{"key":33,"text":458,"correct":35},"消防水泵控制柜启动","ACD",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":459,"analysis":37},974293,"消防增（稳）压设施按稳压工作形式可分为（ ）稳压设施。",[464,466,468,470,472],{"key":20,"text":465,"correct":22},"胶囊式",{"key":24,"text":467,"correct":35},"上置式",{"key":27,"text":469,"correct":22},"补气式",{"key":30,"text":471,"correct":22},"无负压",{"key":33,"text":473,"correct":35},"下置式",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":486,"analysis":37},974294,"消防增（稳）压设施按气压罐设置方式可分为（ ）。",[478,480,482,483,484],{"key":20,"text":479,"correct":22},"立式",{"key":24,"text":481,"correct":22},"卧式",{"key":27,"text":467,"correct":35},{"key":30,"text":473,"correct":35},{"key":33,"text":485,"correct":35},"平置式","AB",[488,491,494,497,500,503],{"id":134,"name":489,"category":7,"favorite":490},"领导干部任职前廉政法规知识测试题",92,{"id":492,"name":493,"category":7,"favorite":134},595,"建筑结构与设备",{"id":495,"name":496,"category":7,"favorite":134},715,"招标采购专业知识与法律法规",{"id":498,"name":499,"category":7,"favorite":134},848,"市政方向-通用基础",{"id":501,"name":502,"category":7,"favorite":8},534,"BIM工程师",{"id":504,"name":502,"category":7,"favorite":8},535]